Loading...
HomeMy WebLinkAboutFile Documents.546 McSkimming Rd.0190.2019 (17).ARBK02 DATE Date: Scale: Drawn by: REVISIONS Z4A WWW.ZONE4ARCHITECTS.COM CD SETZ4A 6.29.18 CD SETZ4A 10.18.18 Y:\Shared\Data\_Z4 Projects\1806 546 McSkimming\Model\Archive\2019-08-01_McSkimming_LANDSCAPE CHANGE ORDER.plnBY A101b 8/5/2019 AS NOTED PROPOSED SITE PLAN 1" ACTUAL ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVED546 MCSKIMMING ROADASPEN, COM C S K I M M I N G R E S I D E N C EK-8336CERICBATHLITHOCAST VITREOUS CHINALAVATORYLADENAK-2215 VITREOUS CHINALAVATORYLADENAK-2215 N3'-1"MIN. EL. 100'-1 1/4" EL. 99'-11 1/4" EXISTING DRIVEWAY TO REMAIN EXISTING TREES TO REMAIN, TYP. EXISTING BOULDER WALL, TYP.(7.5' UTILITY EASEMENT)PLAT BK 2A, PG 291NEW ROOF EDGE TO PROPERTY SETBACK APPROXIMATE UTILITY METER LOCATIONS WALLS DASHED BELOW WALLS DASHED BELOW EXISTING GAS METER, RE: SURVEY EXISTING CABLE UTILITY BOX, RE: SURVEY CONNECT FOUNDATION DRAIN TO EXISTING FOUNDATION DRAIN EXTERIOR PATH LIGHTS, RE: LIGHTING CONDENSING UNITS. RDS STANDARDS DO NOT APPLY. NEW SITE WALLS, RE: LANDSCAPE OUTLINE OF NEW RETAINING WALL EXIST. LOW RAILROAD TIE WALL BEYOND PROPERTY LINE TO BE REMOVED LINEAR TRENCH DRAIN LINEAR TRENCH DRAIN PROPER T Y BOUNDA R Y PR O P E R T Y BO U N D A R Y PR O P E R T Y BO U N D A R Y PROPERTY BOUNDARY(10' RE A R YA R D SET B A C K ) (30' FR O N T YA R D SET B A C K ) (30 ' FRONT YARD SETBACK ) (N 10 53' 00" W 40.5 0 ') 41. 0 4 ' FIE L D (N 76 40' 00" E) 21.80' FIELDPROPERTY BOUNDARY(5' SIDE YARD SETBACK)LOT 2OWNER: SHANNON, JOEL I. & MARGARET B.(7.5' UTILITY EASEMENT)(7.5' UT I L I T Y EA S E M E N T )LOT 4OWNER: SHANNON, JOEL I. & MARGARET B.2 2 6 6 A A B B C C 4 4 5 5 F 1 1 D D D.1 3 3 E E 14 13 1' - 6 "GC LOT 3, BLOCK 3 ASPEN GROVE SUBDIVISION CONTAINING: 16,727 SQ. FT. +/-NCHANGE ORDER 03Z4A 08.05.19 SCALE: 1/8" = 1'-0"01 PROPOSED SITE PLAN EXISTING CONTOUR PROPOSED CONTOUR PROPOSED ADDITIONS 1. ARCHITECTURAL T.O. SLAB 100'-0" EQUALS SURVEY ELEVATION 8178.0'. 2. ARCHITECTURAL SITE PLAN USED TO LOCATE RESIDENCE ONLY. (SURVEYOR TO CONFIRM EXACT LOCATION IN FIELD PRIOR TO EXCAVATION). ALL OTHER INFORMATION SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. 3. EXISTING CONTOURS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. 4. REFER TO SURVEY FOR ACCURATE EXISTING CONDITIONS INCLUDING TOPOGRAPHY AND LOCATION OF EXISTING UTILITIES. 5. REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR PROPOSED GRADING AND DETAILED LANDSCAPE INFORMATION, INCLUDING TREE REMOVAL + MITIGATION. 6. G.C. AND ARCHITECT TO FIELD VERIFY FINAL GAS AND ELECTRICAL METER LOCATIONS PRIOR TO INSTALLATION. REFER TO CIVIL + ELECTRICAL DOCUMENTS FOR GAS AND ELECTRIC METER LOCATION. 7. G.C. AND ARCHITECT TO FIELD VERIFY FIRE ALARM AND STROBE LOCATIONS WITH FD PRIOR TO INSTALLATION (IF REQUIRED). 8. REFER TO LIGHTING DOCUMENTS FOR EXTERIOR LIGHTING PLAN. SITE PLAN KEYNOTES: CONTOUR LEGEND 08/08/2019 09/10/2019 09/18/2019 tonyf Plunge pool