HomeMy WebLinkAboutFile Documents.546 McSkimming Rd.0190.2019 (21).ARBKSTRUCTURAL GENERAL NOTES GENERAL 1.All construction shall conform to the 2015 editions of the International Residential Code (IRC) & International Building Code (IBC), and the City of Aspen amendments. 2.Details not specifically shown on these drawings shall be similar to details for like construction as shown on these drawings. 3.The Contractor shall verify all dimensions and conditions at the job site, and shall report any discrepancies to the Architect and Structural Engineer of Record (S.E.O.R.) before proceeding with work. 4.Refer to Architectural drawings for dimensions and other information not specifically shown on Structural Drawings. Dimensions shown are approximate and are provided as an aid in interpreting the drawings and must be verified with the Architectural drawings. In the event of conflict, dimensions shown on the Architectural drawings shall govern. Notify the S.E.O.R. of any discrepancies prior to constructing the impacted portions of the work. Scaled dimensions shall not be used. 5.No structural members shall be cut, notched or otherwise penetrated unless specifically approved by the S.E.O.R. in advance or as shown on these drawings. 6.Provide openings, curbs, framing, supports and attachments for items as indicated on Architectural, Mechanical, Electrical or other drawings included in the Construction Documents. 7.Where these General Notes and typical details are in conflict with the Specifications, these Notes and Details shall govern. MANUFACTURED WOOD PRODUCTS 1.Manufactured wood I-joists shall be installed in accordance with the manufacturer's recommended details for blocking, bracing, bearing and connections. See plan for size, depth and product designations. Any alternate products shall be submitted to the engineer for written approval prior to construction. 2.Laminated Veneer Lumber (LVL) beam & column plies shall be 13 4" in width with number of plies and depths as noted on plan. LVL shall have the following minimum working stresses: Fc pll=2,510 psi, Fb=2,600 psi, Fv=285 psi, E=2,000,000 psi. 3.Laminated Strand Lumber (LSL), beams (13 4" min) and rimboard (114" min) shall be as noted on plan, with the following minimum working stresses: Fc pll=1,400 psi, Fb=1,700 psi, Fv=400 psi, E=1,300,000 psi. 4.Versa-Stud (112" min) shall be noted on plan, with the following minimum working stresses: Fc pll=3,000 psi, Fb=2,400 psi, E=1,700,000 psi. 5.Parallel Strand Lumber (PSL) beams shall be as noted on plan with the following minimum working stresses: Fb=2,900 psi, Fv=290 psi, E=2,000,000 psi. 6.Parallel Strand Lumber (PSL) columns shall be as noted on plan with the following minimum working stresses: Fc pll=2,500 psi, Fb=2,400 psi, Fv=190 psi, E=1,800,000 psi. 7.Glulam (GL) beams shall be as noted on plan with the following minimum working stresses: 24F-V4, Fb(tension zone)=2,400 psi, Fv=240 psi, E=1,800,000 psi. All mult-span beams, including cantilever conditions, shall be 24F-V8 unless noted otherwise in the drawings. 8.Manufactured wood products as noted above shall be installed per manufacturer's specifications. 9.Manufactured wood products in contact with concrete or masonry foundation or exposed to exterior conditions shall be treated per manufacturer's specifications. 10.Wood manufactured products other than those noted, which have I.C.B.O. approval, may be used with approval by the engineer of record. Substitutions made by the Owner or Contractor shall include all connection hardware as required for sizes used, and shall have equivalent load ratings as those called for on the Drawings. STRUCTURAL ERECTION AND BRACING REQUIREMENTS 1.The Structural Drawings illustrate the completed structure with all elements in their final positions, properly supported and braced. 2.The Contractor, in the proper sequence, shall provide shoring and bracing as required during construction to achieve the final completed structure. Design, sequencing, location, placement, etc. of bracing and shoring is the responsibility of the Contractor. 3.The Contractor shall be responsible for the safety of the building and workers during construction. The Contractor shall comply with all applicable safety regulations. BACKFILLING 1.Contractor shall not backfill against basement and/or retaining walls until all supporting elements (ex: concrete slabs and/or floor framing) are in place and securely anchored, or until adequate temporary shoring is installed. 2.Contractor shall verify type of backfill material with Geotechnical Engineer prior to backfilling. FASTENER AT NEAR FACE FASTENER AT FAR FACE (3-PLY & 4-PLY ONLY) PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 10d NAILS @ 12"o.c.ONE FACE EA FACE PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 12d NAILS @ 12"o.c.ONE FACE EA FACE 2"12"/24"o.c.2"PLY TO PLY CONNECTION 3-PLY2-PLY 3 ROWS 16d NAILS @ 12"o.c.ONE FACE EA FACE 4-PLY EA FACE2 ROWS 1/4"x6" SDS SCREWS @ 24"o.c. 4-PLY 3 ROWS 1/4"x6" SDS SCREWS @ 24"o.c.EA FACE FOR COLUMNS OVER 3-PLY, ATTACH EACH ADDITIONAL PLY w/ (2) ROWS OF 10d NAILS @ 12"o.c. SAWN LUMBER (2" NOM. THICKNESS) CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH < 14" CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH > = 14" CONNECTION SCHEDULE 2-PLY MEMBER 3-PLY MEMBER 4-PLY MEMBER ELEVATION 1. FLOOR SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS FLOOR SHEATHING, RATED STURD-I FLOOR, 24" o.c, 23 32" THICK, T & G. FLOOR SHEATHING SHALL BE GLUED AND FASTENED TO FLOOR JOISTS & BEAMS USING ADHESIVES CONFORMING TO APA SPECIFICATION AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REMOVE WATER, DUST AND DEBRIS FROM JOISTS. APPLY GLUE TO JOISTS & BEAMS AND COMPLETE ALL FASTENING BEFORE GLUE SETS. FLOOR SHEATHING USED AT EXTERIOR DECKS SHALL BE LABELED "EXTERIOR" OR "EXPOSURE 1". 2. ROOF SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS ROOF SHEATHING, LABELED "EXTERIOR" OR "EXPOSURE 1", RATED SHEATHING, 40/20, 5/8" THICK 3. FLOOR AND ROOF SHEATHING LAYOUT: 3-SPAN CONTINUOUS - MIN, PERP TO FRAMING MEMBERS TYP FLOOR & ROOF SHEATHING SCALE: NTS 1 BRACED WALL PANELS 1.All bearing walls, including unlabeled, hatched BWP's, shall be continuously sheathed as Typical Exterior or Interior Panels, accordingly. 2.Typical Exterior Panels shall be 7 16" APA rated OSB or plywood attached to studs w/ 8d common or galvanized box nails (13 8" stud penetration) @ 6"o.c. at panel edges & 12"o.c. at intermediate supports. Block all panel edges. 3.Typical Interior Panels shall be 5 8" gypsum board, both sides of wall, attached to studs w/ 6d cooler nails, 0.120 x 13 4", min 3 8" head (or No. 6 114" Type S or W screws), spaced at 4"o.c. at all supports, studs & plates. Studs shall be spaced @ 24"o.c. max @ panels. 4.All hatched BWP's are critical to the current lateral force resisting system design. They shall not be modified. 5.Special BWP's, holdown straps & anchors, as required, are denoted per plans and shall be constructed per schedules shown on these drawings. 2'-0" MIN LAP - U.N.O. WOOD AND TIMBER FRAMING 1.All wood and heavy timber construction shall conform to the American Institute of Timber Construction (AITC) and National Design Specification (NDS) Standards, latest edition. 2.Structural framing lumber shall be at a minimum, as noted below, unless noted otherwise, and shall have a maximum moisture content of 19% at time of delivery. 3.Provide solid blocking at supports between joists and rafters. Within floor joist spaces beneath solid or built-up posts, provide solid blocking with area same as post above. 4.All plywood shown on these drawings shall be minimum C-D grade with exterior glue in accordance with DOC PS 1 and comply with IBC section 2304. 5.Sill plates shall be of naturally durable wood, or Zinc Borate treated LSL or Douglas Fir-Larch per IBC Section 2304.12 with Fc perp = 625 psi, minimum and shall be protected for dry use. 6.All wood framing shall be preservative pressure treated when in contact with concrete or masonry foundation or exposed to exterior conditions. All fasteners used to connect pressure-treated wood shall be hot-dipped galvanized (HDG) or stainless steel. 7.Except as noted otherwise, provide minimum nailing as specified in IBC Table 2304.10.1. Structural nailing shall be with common nails, unless otherwise noted on the Drawings. Nails exposed to weather shall be galvanized. Nails used to connect preservative treated wood shall be hot dipped galvanized (HDG) or stainless steel. 8.Metal timber connectors shall be Simpson Strong-Tie or equivalent. Hardware specified is for specific member size & manufacturer as show on the structural drawings. Hanger slope, skew & top flange shall be designated by the contractor as required. Simpson connectors for preservative treated wood or connectors in contact with concrete shall be ZMAX or HDG, or as otherwise recommended by specific connector supplier. Install all connectors in accordance with manufacturer's instructions for maximum rated loads. 9.Bolts used as timber-to-steel or timber-to-timber connectors shall be ASTM A307 unless noted otherwise on the Drawings. Bolts shall be installed in accordance with the requirements of the latest edition of the National Design Specification for Wood Construction (NDS) by the National Forest Products Assoc. Bolts used to connect pressure-treated wood shall be HDG or stainless steel. 10.Lag screws shall be ASTM A307. Holes for lag screws shall be bored the same depth and diameter as the bolt shank. The remaining depth of penetration shall be bored per NDS requirements. Lag screws used to connect pressure-treated wood shall be HDG or stainless steel. 11.Provide malleable iron washers or equivalent cut plate washers under all nuts, bolts or lag screw heads which bear on wood. 12.Wood screws shall be steel per NDS requirements. Pre-drill holes to prevent splitting as recommended in the NDS. 13.Wood members shall be cut or notched only as shown on the Structural Drawings. 14.Provide cross bridging, solid bridging or other lateral support for all framing members in accordance with the requirements of IBC Section 2308. 15.Except where more stringent construction is shown on the Drawings, wood construction shall comply with the requirements of the IBC, latest edition, as a minimum. SHEATHING NAILING SHEATHING APPLICATION FASTENERS NAIL SPACING COMMENTS @ INTERMEDIATE SUPPORTS @ PANEL EDGES WOOD FLOOR 8d COMMON (0.131 Ø)12"6"GLUED (SEE NOTE 1) WOOD ROOF 8d COMMON (0.131 Ø)12"6"- DBL 2x TOP PL TYP U.N.O. (2) 10d @ CORNER & INTERSECTION LAPS 10d COMMON @ 24"o.c. (2) 10d ADD'L (8) 10d COMMON MIN BTWN SPLICES TYPE SPECIES GRADE Fb (MIN) Existing 2x structural Joists, Rafters & Headers Hem Fir No. 2 850 psi 2x Structural Joists, Rafters & Headers Douglas Fir-Larch No. 2 900 psi 2x Studs, Posts & Plates Douglas Fir-Larch No. 2 900 psi Versa-Stud 1.7E 2,400 psi Plates Douglas Fir-Larch No. 2 900 psi LSL 1.3E 1,700 psi Stringers, Beams & Posts (4x)Douglas Fir-Larch No. 1 1,000 psi Stringers, beams (6x & greater)Douglas Fir-Larch No. 1 1,350 psi Posts (6x & greater)Douglas Fir-Larch No. 1 1,200 psi SPECIAL INSPECTION 1.The owner shall employ a special inspector per IBC Chapter 17. The special inspector shall submit a copy of all his reports to the Owner, Architect, Structural Engineer and the Building Department. When the work is completed, the special inspector shall submit a final signed report stating whether the work was, to the best of his knowledge, in conformance with the approved set of plans and specifications and the applicable workmanship provisions of the building code. The structural engineer of record will make visits to the site to observe general compliance with the approved structural plans, specifications and change orders. The contractor shall coordinate with the special inspector in order to ensure that the special inspection as indicated below can be performed with minimal impact to the project schedule. 2.Special inspection is required for the following types of work. Refer to Chapter 17 of the 2015 IBC for additional testing and specific requirements. 2.1.All cast-in-place concrete work & reinforcing placement, except nonstructural concrete (periodic). 2.2.All masonry construction (periodic per IBC 1705.4). 2.3.All bolts and embeds in concrete (continuous if wet stabbed, periodic if tied). 2.4.All shop and field welding (periodic). 2.5.All high-strength bolted connections (periodic). SHOP AND ERECTION DRAWINGS 1.The Contractor shall furnish a PDF set of shop and erection drawings for review to the Architect and Structural Engineer of Record prior to fabrication for the following items: 1.1.Structural steel 2.The manufacture, fabrication or erection of above noted items prior to written review by the Architect and Structural Engineer of Record is at the sole risk of the Contractor. A35 OR LS50 CLIP @ KING STUD TO TOP & BOT PL's @ WALL OPNG WIDTH > 4'-0" & (2) A35 OR LS50's @ WIDTH > 7'-0" - TYP U.N.O. 2x SILL PL - USE (2) 2x PL's w/ A35 EA END @ EXT WALL OPNG 8'-0" & GREATER - TYP (1) 2x6 TRIM STUD MIN, TYP U.N.O. PER PLAN (2) 2x6 HDR MIN, TYP U.N.O. PER PLAN (2) 16d COMMON, END NAIL OR (4) 8d COMMON TOENAIL, EA STUD - TYP BOT/SILL PL - SEE PLAN NOTES OR SPECIFIC DETAILS FOR ANCHOR BOLT SIZE & SPACING 2x6 STUDS @ 16"o.c. PER PLAN & DETAILS - U.N.O 2x SOLID BLKG REQ'D AT CEILING LINES & AT ALL EDGES OF EXT WALL SHTG (1) 2x6 KING STUD MIN, TYP U.N.O. PER PLAN (4) 16d COMMON (2) 16d COMMON, END NAIL, TOP PL TO EACH STUD - TYP A.F.F.______A.F.F.______ ABV_______ABOVE ADD'L______ADDITIONAL ADJ________ADJUSTABLE ALT________ALTERNATE A.C.I._______AMERICAN CONCRETE INSTITUTE A.P.A.______AMERICAN PLYWOOD ASSOC. AB_________ANCHOR BOLT ARCH______ARCHITECT(URAL) BM_________BEAM BLW_______BELOW BRG_______BEARING BTWN______BETWEEN BLKG______BLOCKING B or BOT____BOTTOM B.O.________BOTTOM OF B.O.W._____BOTTOM OF WALL BWP_______BRACED WALL PANEL BLDG______BUILDING CANT'D_____CANTILEVERED C.I.P._______CAST-IN-PLACE CLR________CLEAR CNTRD_____CENTERED CL_________CENTERLINE CW________CLOCKWISE COL_______COLUMN C.J.P.______COMPLETE JOINT PENETRATION CONC______CONCRETE C.M.U.______CONCRETE MASONRY UNIT CONN______CONNECTION CONST_____CONSTRUCTION CONT______CONTINUOUS CONTR_____CONTRACTOR C.J. _______CONTROL JOINT CCW_______COUNTER-CLOCKWISE DIAG_______DIAGONAL DL_________DEAD LOAD DEFL_______DEFLECTION D.B.A.______DEFORMED BAR ANCHOR D.W.F.______DEFORMED WIRE FABRIC E.F.________EACH FACE E.N.________EDGE NAILING EL_________ELEVATION ELEV_______ELEVATOR EMBED_____EMBEDMENT EQ_________EQUAL EQUIV______EQUIVALENT EXISTG/(E)__EXISTING EXP________EXPANSION EXT________EXTERIOR F.D.________FLOOR DRAIN FLG________FLANGE FTG________FOOTING FDN________FOUNDATION GA_________GAUGE/GAGE GALV______GALVANIZED, HOT DIP G.C._______GENERAL CONTRACTOR GL_________GLUE-LAMINATED MEMBER G.B.________GRADE BEAM HGR_______HANGER H.A.S.______HEADED ANCHOR STUD HDR_______HEADER HT_________HEIGHT HSS________HOLLOW STRUCTURAL STEEL HK_________HOOK HORIZ______HORIZONTAL I.F._________INSIDE FACE INT________INTERIOR IBC________INTN'L BUILDING CODE IRC________INTN'L RESIDENTIAL CODE ISO________ISOLATION JT_________JOINT JST________JOIST K__________KING KSI________KIPS PER SQUARE INCH LVL________LAMINATED VENEER LUMBER LT_________LIGHT LL_________LIVE LOAD LOC________LOCATION LLH________LONG LEG HORIZONTAL LLV________LONG LEG VERTICAL MFR_______MANUFACTURER M.O._______MASONRY OPENING MAT'L______MATERIAL MAX_______MAXIMUM MECH______MECHANICAL MTL________METAL MISC_______MISCELLANEOUS MIN________MINIMUM M.F.MOMENT FRAME N.S.________NOT SHOWN NTS________NOT TO SCALE o.c.________ON-CENTER OPNG______OPENING O.H._______OPPOSITE HAND OSB_______ORIENTED STRAND BOARD O.F.________OUTSIDE FACE PLL________PARALLEL PSL________PARALLEL STRAND LUMBER PEN________PENETRATION PERP______PERPENDICULAR PLCS_______PLACES PL_________PLATE PLWD______PLYWOOD PLF________POUNDS PER LINEAR FOOT PSF________POUNDS PER SQUARE FOOT P.A.F.______POWER-ACTUATED FASTENER P.C.________PER CAST P.E.________PRE-ENGINEERED P.T.________PRESSURE TREATED R__________RADIUS RE:________REFER TO REINF______REINFORCING/MENT REQ'D______REQUIRED R.D.________ROOF DRAIN R.S.________ROUGH SAWN SCHED_____SCHEDULE SHTG______SHEATHING SHT________SHEET SIM________SIMILAR S.O.G.______SLAB ON GRADE SP_________SPACE (ING) SPECS_____SPECIFICATIONS STAG______STAGGERED S.S.________STAINLESS STEEL STD________STANDARD STL________STEEL STRUCT____STRUCTURAL S.E.O.R.____STRUCTURAL ENGINEER OF RECORD SYM_______SYMMETRICAL T&B________TOP AND BOTTOM T.O.________TOP OF T.O.M.______TOP OF MASONRY T.O.S.______TOP OF STEEL T.O.W._____TOP OF WALL T.P.________TOP PLATE T&G_______TONGUE AND GOOVE T__________TRIMMER TS_________TUBE STEEL COLUMN TYP________TYPICAL U.B.C.______UNIFORM BUILDING CODE U.N.O.______UNLESS NOTED OTHERWISE V.I.F._______VERIFY IN FIELD VERT______VERTICAL WT________WEIGHT WWF_______WELDED WIRE FABRIC w/_________WITH WD________WOOD W.P._______WORK POINT ABBREVIATIONS TYPICAL FRAMING CONNECTION SCHEDULE (MINIMUM U.N.O.)1, 2 NAILING TYPE Joists or Rafters to T.O. Double Top Plate, Sill Plate or Beam (3) 10d Toenail Rim Joist or Structural Fascia to Joists, Rafters (2) 16d, (1) T&B End Nail Sole Plate to Sill Plate (3) 10d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg - Typ (2) 16d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg at BWP (3) 16d @ 16"o.c.Face Nail Double Studs, Built-up Corner Studs, Trim Studs to King Studs1 Per Typ Detail Rim Joist to Top Plate 8d @ 6"o.c.Toenail Blkg Btwn Rafters & Joists to Top Plate, Sill Plate or Beam 8d @ 6"o.c. (3) min per block Toenail 2x Decking to Joists (2) 10d each joist Face Nail 1. Refer to Typical Multiple Ply Beams & Columns Detail for additional information. 2. Refer to Typical Framed Wall Detail for additional information. TYP DBL TOP PL CONN's TYP MULTI-PLY BEAMS & COLUMNS SCALE: N.T.S. 32 SCALE: 3 4" = 1'-0" TYP WALL FRAMING DETAIL 57 BAR Ø (24" MIN)57 BAR Ø(24" MIN)57 BAR Ø (24" MIN) CORNER INTERSECTION & END OF WALL ALTERNATE CORNER 57 BAR Ø (24" MIN) CORNER BAR AT EA HORIZ BAR - TYP LAP HORIZ BARS EA SIDE OF CORNER - TYP (1) #5 VERT AT END OF WALL OR CORNER - TYP57 BAR Ø(24" MIN)4 NOT TO SCALE TYP REINF AT CONC WALLS S0.001 S0.001 S0.001 S0.001 ATTACH ALL KING, TRIM STUD & HEADER, BEAM PLIES PER TYP MULTIPLE PLY BM & COL DETAIL FRAMING MEMBERS12 DR R R = 4D FOR #3 THRU #8 BARS R = 5D FOR #9 THRU #11 BARS R = 6D FOR # 14 AND #18 BARS 90° HOOK 180° HOOK R R 4D OFFSET 57 BAR Ø FOR CONC 64 BAR Ø FOR MASONRY TIED BARS MIN 1.5D OR 1" MAX 1/5 LAP LENGTH OR 6" LAP SPLICE 212" MIN TYP REINF DETAILS5 NOT TO SCALE REINFORCED CONCRETE 1.All concrete design is based on the "Building Code Requirements for Reinforced Concrete", ACI 318, latest edition, associated Commentary (ACI 318R), and IRC/IBC Requirements. 2.All structural concrete shall be in accordance with ASTM C39. Minimum compressive strengths noted are required at 28 days, typical unless noted otherwise. 2.1.For structural concrete in buildings of occupancy categories R-2 & R-3: Minimum compressive strength = 3000 psi. Exterior & garage slab minimum compressive strength = 3,500 psi & air entrained 5-7%. 2.2.Structural concrete for all other structures: Minimum compressive strength = 3,500 psi & maximum w/cm ratio of 0.50. Exposed to freeze-thaw cycles minimum compressive strength = 4500 psi & maximum w/cm ratio of 0.45. Exposed to deicing chemicals = 5000 psi & maximum w/cm ratio of 0.40. 2.3.Stained or polished floor slabs: Minimum compressive strength = 4000 psi with low pozzolanic material ratios. 3.All concrete shall be consolidated using mechanical vibrators. 4.All concrete work shall conform to the requirements of the IBC and ACI Standard 318, latest edition, of the American Concrete Institute (ACI), unless shown or noted otherwise on these drawings. 5.Aggregate shall conform to ASTM C33. 6.Cement shall be ASTM C150, Type I or Type II modified. 7.Concrete shall be placed in accordance with ASTM C94 and ACI Standard 304. 8.All embedded items shall be placed accurately and secured prior to beginning concrete placement. 9.Construction joints shall be located so as not to impair the strength of the structure. Construction joints shall comply with ACI 318, unless noted otherwise. 10.Concrete mix designs shall be submitted to the Architect & S.E.O.R. for approval prior to placement of any concrete. 11.Reinforcement and embedded items shall be free of excessive scale, rust, dirt, grease, & all or any other substance that will impair bond with concrete. REINFORCING STEEL 1.All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice. 2.Except where otherwise noted on the Drawings, reinforcing bars shall conform to ASTM Specification A615 and shall be Grade 60. Ties and field-bent bars as noted on plan shall be Grade 40. All reinforcing bars to be welded shall conform to ASTM A706. 3.Welded wire fabric reinforcement shall conform to ASTM A185 and shall be sheet-type; roll-type is not acceptable. 4.Coverage for reinforcing bars shall be in accordance with the requirements of the IBC, the ACI Standard 318 and in the Table below, unless shown otherwise on the Drawings. 5.Lap splices for reinforcing bars shall be 57 bar diameters (24" minimum) for concrete reinforcement and 72 bar diameters (36" minimum) for masonry reinforcement unless shown otherwise on the Drawings. Wire bars together at laps or splices. Stagger laps in adjacent horizontal bars a minimum of the required splice length. Hooks shall be ACI standard hooks unless shown otherwise. Welded wire fabric shall be spliced by lapping a minimum of 12 inches, or (2) cross wires, whichever is greater. STRUCTURAL STEEL 1.All detailing, fabrication, and erection of structural and miscellaneous steel shall be in accordance with the requirements of the American Institute of Steel Construction (AISC) Code of Standard Practice, latest edition, and the American Welding Society (AWS) Specifications. 2.All structural steel rolled shapes, except angles and plates, shall conform to ASTM A992, 50 ksi. 3.Angles, channels & plates shall conform to ASTM A36, 36 ksi, unless otherwise noted on the Drawings. 4.Pipes shall conform to ASTM A53, Grade B, 35 ksi. 5.Tube shapes (HSS) shall conform to ASTM A500, Grade B, rectangular shapes = 46 ksi & round shapes = 42 ksi. 6.All bolts for steel-to-steel connections shall conform to ASTM A325, unless otherwise noted on the Drawings. 7.All anchor bolts shall conform to ASTM F1554 Gr. 36, unless otherwise noted on the Drawings. 8.All shear studs shall conform to ASTM A108 & shall be welded to steel beams for full shear capacity. 9.All welding shall be in accordance with the requirements of the IBC and the Structural Welding Code, AWS D1, latest edition, by the American Welding Society. Shop welding shall be performed in shops approved by the Building Official, per IBC Section 1704.2.5. Welding shall be done using E70XX electrodes, unless noted otherwise on the Drawings. 10.Expansion bolts and epoxy anchors called for on the Drawings shall be Hilti or approved equivalent, with embedment as shown on the Drawings. Expansion bolts shall be Hilti Kwik Bolt 3 & Epoxy shall be Hilti HIT-HY 200 or approved equivalent, unless otherwise noted on the Drawings. 11.Powder actuated fasteners shall be Hilti DNI or approved equivalent, with full penetration into steel members, unless otherwise noted on the Drawings. 12.Steel, including bolts & anchors, in contact with earth, or as otherwise noted on the Drawings, shall be hot dip galvanized or prime painted. Do not paint within 3" of field welds until welds are completed. GROUT & ADHESIVE 1.All grout beneath column base plates, or steel beams at bearing shall be non-metallic, non-shrink high strength grout by "Five Star, "Embeco", or approved equal installed to manufacturer's specifications. 2.All structural construction adhesive specified shall be Loctite PL Premium Fast Grab or approved equal & shall be installed to manufacturer's specifications. MINIMUM CONCRETE COVER FOR REINFORCEMENT1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER No. 6 thru No. 18 bars 2" No. 5 bar, W31 or D31 wire, and smaller 112" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND Slabs, Walls, Joists:No. 14 and No. 18 bars 112" No. 11 bar and smaller 3 4" Beams, Columns:Primary reinforcement, ties, stirrups, spirals 112 1.Minimum concrete cover specified or for cast-in-place, nonprestressed concrete DESIGN LOADS 1.ROOF LOADS Dead Load .......................................20 psf Live Load (Snow).............................75 psf* 2.FLOOR LOADS Dead Load .......................................15 psf Live Load .........................................40 psf 3.LATERAL LOADS Seismic Design Category.................C Basic Wind Speed ...........................115 mph Exposure Category .........................B Importance Factor ...........................1 * No duration of load increase was used in design FOUNDATIONS 1.Concrete foundations are designed based on the following assumed soil values (full dead load plus full live load, placed on natural soils and/or engineered structural fill per soils engineer). Soil Density = 120 pcf (Assumed) Allowable Bearing Pressure = 2,000 psf Lateral At-Rest Earth Pressure = 50 pcf Lateral Active Earth Pressure = 40 pcf Lateral Passive Earth Pressure = 400 pcf (Ultimate) Coefficient of Friction for Footing = 0.50 (Ultimate) Frost Depth = 36" min 2.Soils conditions and types, at the proposed foundation bearing elevations, shall be verified as adequate for the noted soil values, by a representative of a qualified Geotechnical Engineer (employed by Owner) during excavation. 3.Proper surface and below grade perimeter drainage shall be installed per Civil & Geotechnical Engineers to relieve foundations from hydrostatic pressures. 4.It is the responsibility of the Contractor to review the Geotechnical Engineer's recommendations and notify the Architect and/or S.E.O.R. if any changes to the design are required prior to start of construction. S0.001 EXISTING FLOOR JOIST OR ROOF RAFTER, U.N.O. EXISTING FLUSH BEAM SUPPORTING FRAMING EXISTING DROPPED BEAM SUPPORTING FRAMING EXISTING HEADER SUPPORTING FRAMING STRUCTURAL SYMBOLS LEGEND EXISTING MASONRY CONSTRUCTION NEW CONCRETE FOUNDATION WALL & FOOTING EXISTING CONCRETE FOUNDATION WALL & FOOTING EXISTING LEDGER SUPPORTING FRAMING EXISTING BEARING WALL TO BE REMOVED EXISTING BEARING WALL ROOF OR FLOOR MEMBER SPAN AND LENGTH ARROWS DESIGNATE BEARING LOCATIONS ROOF OVERFRAMING PER TYPICAL DETAIL / S0.0 X STEEL OR WOOD COLUMN WHICH SUPPORTS FRAMING OR LOADS FROM ABOVE SEE WALL FRAMING NOTES FOR MIN SIZE, NUMBER, AND TYPE FLOOR JOIST OR ROOF RAFTER, U.N.O. JOIST HANGER OR BEAM TO BEAM CONNECTION RE: HANGER SCHEDULE FOR CONN, U.N.O. FLUSH BEAM SUPPORTING FRAMING VERTICAL STEP IN FLOOR WOOD STUD BEARING WALL ABOVE NON-BEARING WOOD STUD WALL BELOW FRAMING REVISION CLOUD INDICATING A REVISED ITEM REVISION NUMBER CORRESPONDS WITH REVISIONS IN TITLE BLOCK STEEL OR WOOD COLUMN FROM ABOVE OR B/W BEAMS WHICH IS SUPPORTED ON FRAMING, MIN WIDTH TO MATCH SUPPORTED FRAMING, U.N.O. EXISTING ROOF OR FLOOR MEMBER SPAN AND LENGTH ARROWS DESIGNATE BEARING LOCATIONS DROPPED BEAM SUPPORTING FRAMING HEADER SUPPORTING FRAMING WALL STEP, POINTS IN DIRECTION OF DOWN MASONRY CONSTRUCTION LEDGER SUPPORTING FRAMING 2x WOOD STUD BEARING WALL BELOW FRAMING MOMENT CONNECTION INDICATES LOCATION OF EXTERIOR AND INTERIOR BRACED WALL PANELS (BWP's). WHERE BWP's ARE NOT DIMENSIONED, EXTEND BETWEEN WALL OPENINGS OR CORNERS AS SHOWN ON PLAN. SEE BRACED WALL PANEL NOTES / S0.0 HOLDOWN FRAMING STRAP OR FOUNDATION ANCHOR PER PLAN & SCHEDULE STEEL OR WOOD COLUMN FROM ABOVE WHICH IS CONTINUOUS TO LEVEL BELOW OR TO FOUNDATION HxJOIST JOIST JOIST JOIST REVISIONS: DATE: 05/14/18 PROJECT # : 18.018C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 MCSKIMMING RESIDENCE546 MCSKIMMING ROADASPEN, COLORADO05/14/18 PERMIT 05/25/18 PRICING 06/29/18 CD 07/02/18 ASI #1 1 01/25/19 CO #13 2 08/05/19 SITE WALLS GENERAL STRUCTURAL NOTES & TYPICAL DETAILS S0.001 08/05/2019 08/08/2019 09/18 / 2 0 1 9 tonyf DECK 6 5 4 3 2 1 A B C D D.1 E F A B C D D.1 E F 3'-0" WIDE x 12" DEEP FTG w/ #5 @ 16" EA WAY, BOT - TYP U.N.O. 8" CONC WALL CNTRD ON FTG w/ #5 @ 16"o.c. EA WAY CTRD - TYP U.N.O. 2 S6.004 T.O. FF = 100'-1 14" T.O. WALL VARIES 8" CONC WALL w/ #5 @ 12"o.c., EA WAY CTRD 12" DEEP FTG w/ #5 @ 12" EA WAY, BOT 3 S6.004 T.O. WALL VARIES 10" CONC WALL w/ #5 @ 10"o.c. EA WAY O.F. 14" DEEP FTG w/ #5 @ 12" EA WAY, BOT TYP U.N.O. 1 S6.004 1 S2.005SIM 1 S6.004SIM3'-0" WIDE x 12" DEEP FTG w/ #5 @ 16" EA WAY, BOT - TYP U.N.O. T.O.W PER CIVIL - MAX RETAINED HT = 7'-0" T.O.W PER CIVIL - MAX RETAINED HT = 3'-0" T.O.W PER LANDSCAPE & CIVIL - MAX RETAINED HT = 1'-6" T.O.W SLOPES UNIFORMLY - TYP T.O. WALL 97'-0" T.O. WALL 98'-4" T.O.W SLOPES MAX 4" BELOW GRADE L4x4x14 CONT EMBED AT I.F. w/ 12"Ø x 6" WHS @ 16"o.c. PLANTER PL 12 INSTALLED IN FIELD - LOCATIONS PER LANDSCAPE ARCH 12" DEEP FTG w/ #5 @ 12" EA WAY, BOT TYP U.N.O. 4 S6.004 8" MIN CONC WALL w/ #5 @ 12"o.c. EA WAY CTRD - TYP @ POOL RET WALLS T.O. FTG 87'-8" V.I.F. T.O. WALL 93'-0" T.O. FTG 91'-0" V.I.F.8" MIN CONC WALL w/ #5 @ 12"o.c. EA WAY CTRD 4 S6.004 L4x4x14 CONT EMBED w/ 12"Ø x 6" WHS @ 16"o.c. - AT PLANTER TYP WHERE STL PLATE OCCURS RETAINING WALL LOCATION & EXTENTS TO BE COORD w/ LANDSCAPE DRAWINGS - TYP U.N.O. RADIUSED WALL TANGENT POINT T.O.W PER LANDSCAPE & CIVIL - MAX RETAINED HT = 5'-7"T.O.W PER CIVIL - MAX RETAINED HT = 3'-0" T.O. FTG 87'-8" V.I.F. 10'-0" 1'-0" 1'-0" 4'-0"3'-6"39'-912"1'-112"4'-714"R156'-014"R153'-714"R86'-214"41'-13 4"V.I.F.30'-31 4 " 64'-101 2 "14'-2"11"15'-1"7'-33 4"27'-81 4"3'-5"6'-8"6'-4"5'-8"21'-814"3'-33 4"14'-2"18'-6"4'-33 4" 3'-113 4"14'-812"6'-31 4"4'-0"15'-2"16'-33 4"6'-214" 5'-914"5'-512"8'-4"6'-8"T.O. WALL 91'-6" DOWEL ALL HORIZ REINF TO (E) WALL & FTG -TYP, EMBED 4" IN EPOXY 10'-4"6'-8"3'-1134"11'-714"15'-63 4" T.O. WALL 93'-0" T.O. WALL 93'-0"1'-112"3'-212"6"1'-0"B.O. WING WALL = 90'-0" V.I.F. - TYP @ 2 B.O.W WALL STEP 6'-4" TEMP SHORING AS REQ'D BY OTHERS 20'-0 3 4 " REVISIONS: DATE: 05/14/18 PROJECT # : 18.018C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 MCSKIMMING RESIDENCE546 MCSKIMMING ROADASPEN, COLORADO05/14/18 PERMIT 05/25/18 PRICING 06/29/18 CD 07/02/18 ASI #1 1 01/25/19 CO #13 2 08/05/19 SITE WALLS SITE WALL PLAN S2.005 SITE WALL PLAN SCALE: 316" = 1'-0"A 08/05/2019 08/08/2019 09/18 / 2 0 1 9 tonyf PERPLANPER PLAN 3" CLRPER PLAN T.O. FTG PER PLAN PER PLAN T.O. CONC PER PLAN T.O. GRADE CONC FTG w/ REINF PER PLAN FLATWORK PER ARCH SCALE: 3/4" = 1'-0"1 SITE WALL DETAIL PER PLAN PER PLAN T.O. FTG PER PLAN T.O. CONC PER PLAN T.O. GRADE CONC FTG w/ REINF PER PLAN DRIVEWAY ASPHALT PER ARCH SCALE: 3/4" = 1'-0"2 SITE WALL DETAILFROST DEPTHFROST DEPTHPERPLAN3" CLR1'-6" (2) #5 T&B PER ARCH2'-0" - MAXCONC RETAINING WALL w/ REINF PER PLAN 2'-6" - MAXCONC RETAINING WALL w/ REINF PER PLAN PER PLAN PER PLAN PER PLAN T.O. CONC CONC FTG w/ REINF PER PLAN DRIVEWAY PER CIVIL SCALE: 3/4" = 1'-0"3 SITE WALL DETAIL RE: S2.005 FROST DEPTHPERPLAN3" CLR 7'-6" - MAX(2) #5 T&B CONC RETAINING WALL w/ REINF PER PLAN 2" CLR 2'-0" #5 HOOKED DOWEL AT EA VERT TYP 3'-6"3'-0"4 SECTION AT PLUNGE POOL POOL LINER PER POOL DESIGNER CONC WALL PER PLAN (E) ADJACENT FTG - V.I.F. POOL EXCAVATION DOES NOT UNDERMINE FOOTING TYP FINISHED PATIO PER LANDSCAPE (E) ADJACENT BLDG FOUNDATION CONC FOOTING / POOL SLAB PER PLAN 5'-4" MAX3'-6"L6x6x12 TYP (3) SIDES OF LANDING SCALE: 3/4" = 1'-0"4 SECTION AT PLUNGE POOL SCALE: 3/4" = 1'-0" STD HOOK TYP STD HOOK TYP 312" CONC OVER 2" DP 20 GAGE GALV METAL DECK BTWN ANGLES w/ 6x6 - W2.1xW2.1 WWF 14" DP x 8" WIDE MIN THICKENED EDGE w/ (2) #4 BOT INTERIOR STAIR LANDING BEYOND W6x20 STL COL TYP BASE PLATE SIM TO 3/S6.001 - TYP CAP PL 3 8 TYP EDGE PL 12 x 6 MIN - WELDED TO ANGLE FRAME LEDGER PL 12 x 3 w/ 3 4"Ø BOLTS @ 6"o.c. - BOLT TO WOOD BM 412" MAX WATERPROOFING & FLASHING PER ARCH TYP RETAINING WALL PER PLAN 1'-0" 1'-4" RETAINING WALL PER PLAN PER PLAN T.O. FTG PER PLAN T.O. FTG PER PLAN T.O. FTG #4 x 1'-6" HOOKED DOWELS @ 12"o.c. RE: S2.005RE: S2.005 RE: S2.005RE: S2.005 PER PLAN T.O. WALL PER PLAN T.O. WALL 112" DP VERT CONTROL JOINTS @ 8'-0"o.c. RECOMMENDED AT EXPOSED CONC RETAINING WALLS - TYP REVISIONS: DATE: 05/14/18 PROJECT # : 18.018C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 MCSKIMMING RESIDENCE546 MCSKIMMING ROADASPEN, COLORADO05/14/18 PERMIT 05/25/18 PRICING 06/29/18 CD 07/02/18 ASI #1 1 01/25/19 CO #13 2 08/05/19 SITE WALLS FRAMING DETAILS S6.004 08/05/2019 08/08/2019 09/18 / 2 0 1 9 tonyf