Loading...
HomeMy WebLinkAboutFile Documents.546 McSkimming Rd.0190.2019 (23).ARBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 09/11/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 SEE NOTES #1 PLANS External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ X 0190.2019.arbk 10/2/2019 2164 sf 96 sf 0 TF 13.22 KW Snowmelt plan, roof plan 10/02/2019 tonyf 97% FIRE SPRINKLERS REQUIRED COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 PROPERTY INFORMATION ___________________________________ _________ ___________________________ ______________ ______________ ________________________________________ _________________________ _______________ __________________________________ ________________________ _______________ __________________________________ CommericalMulti-FamilySingle Family Use of Building Class of Work NewAdditionAlterationRepair ________ YesNo Will there be any roof/wall penetrations? NOTICE: This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced. _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ PROJECTVALUATION SQ FT OF BUILDING WORK AREA UNIT SQ FT SQ FT OF SOILDISTURBANCE BUILDING FOOTPRINT LOT SIZE(SQ FT) PROJECT DETAILS (READ DEFINITIONS BELOW) Mixed-Use IFFRTenant FinishDemolitionChange Order ________ ADDRESS UNIT #PARCEL ID # BLOCK TRACT OR SUBDIVISIONLOT DESCRIPTION OF WORK IN DETAIL Building Review Building Permit Fee Parks Impact Engineering Review Zoning Review (50%) School Lands Dedication Zoning Review (50%) CMP (50%)TDM Impact Energy Code Review REMP Payment Pedestrian Amenity CMP (50%)GIS Housing Cash in Lieu Parks Review City Use Tax Water Tap Utility Review County Use Tax Sanitation SUBMITTAL FEES ISSUANCE FEES APPROVALS ISSUANCE FEES BEST CONTACTNAME CELL EMAIL OWNER NAME CELL EMAIL ____Toilets, Bidets ____Bathtub____Lavatory (Wash Basin)____Shower____Kitchen Sink (+Disposal)____Dishwasher____Laundry Bar, Utility Sink____Clothes Washer ____Floor Sink____Floor Drain____Water Heater (Pan Req)____# Gas Outlets____Water Treatment____Other_________ Fixture Counts Important Review Triggers PC Zoning HPC Building Fire Engineering CMP Water Stormwater Sanitation Env. Health Parks Landscape Efficiency Approved To Issue Issuance Date ApprovedReviewingDepartmentReviewerSign-Off NEW SQ FT Project Valuation: Cost of project as defined in Valuation Affadavit.Sq Ft of Building Work Area: Total square footage of interior area undergoing change or reconfiguration.Unit Sq Ft: Gross square footage, not FAR, of permitted unit.Lot Size: Total surveyed square footage of property.Sq Ft of Soil Disturbance: Exterior area of the lot where the ground is disturbedNew Sq Ft: Total added square footage for additions to net livable or net leasable space.Building Footprint: Grade floor square footage of the permitted structure.Hardscape Area: Square footage of impervious lot surface.Zone District: Underlying zone district of permitted parcel. January 2019 DATE:___________ MASTER PERMIT:______________________ PERMIT NUMBER:__________________________ __________________________________________________________________________________ __________________________________________________________________________________ HARDSCAPEAREA NeedsReview DEFINITIONSZONEDISTRICT Major Engineering Review• Projects involving less than 50% hardscape area and work affecting 75% or greater of unit sq ft• Projects involving greater than 50% hardscape area and work affecting 50% or greater of unit sq ft• Projects involving 1,000+ sq ft of soil disturbance area Water Efficient Landscaping• Projects that trigger a major engineering review • Projects involving interior alterations affecting 50% or more of exisiting gross square footage THIS SECTION MUST BE COMPLETED IN ITS ENTIRETY 08.06.2019 0142.2018.ARBK 0190.2019.ARBK 546 McSkimming 273718102002 3 3 Aspen Grove Subdivision KArin G LLC 305.793.2753 JP@PAG.LAW Zone 4 Architects 970.429.8470 tim@zone4architects.com site wall, on-grade patios, plunge pool, ADA path from drive to lower yard and retaining walls along driveway. 700,000 NA NA 19,100 sq ft 6395 sq ft NA NA 7605 sq ft R-15B X ll 8/8/2019 X BN 9/11/19 X X 25.00 738.69 X JD 10/10/2019 650.00 (hourly)185.68 X AR 9/25/19 82.68 0 X 6851.98 X 3137.24 08/08/2019 TF 10/2/2019 TF 10/2/2019 rm 10/8/19 rm 10/8/19 COMMUNITY DEVELOPMENT DEPARTMENT HOMEOWNER ASSOCIATION COMPLIANCE FORM CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 All applicaions for a building permit within the City of Aspen are required to include a ceriicaion of compliance with applicable covenants and homeowner associaion policies. The ceriicaion must be signed by the property owner or atorney represening the property owner. The following ceriicaion shall accompany the applicaion for a permit. ___________________________________ _________ ___________________________ I, the property owner, cerify as follows: (pick one) This property is not subject to a homeowners associaion or other form of private covenant. This property is subject to a homeowners associaion or private covenant and the improvements proposed in this building permit do not require approval by the homeowners associaion or covenant beneiciary. This property is subject to a homeowners associaion or private covenant and the improvements proposed in this building permit have been approved by the homeowners associaion or covenant beneiciary. I understand the City of Aspen does not interpret, enforce, or manage the applicability, meaning, or efect of private covenants or homeowner associaion rules or bylaws. I understand that this document is a public document. Owner Signature ____________________________ Date _________________ Owner Printed Name ________________________ OR Owner’s Atorney Signature ___________________________ Date _________________ Owner’s Atorney Printed Name _______________________ ADDRESS UNIT #PARCEL ID # ADDRESS: ____________________________ PERMIT NUMBER: _______________________________ January 2018 546 MCSKIMMING RD. ASPEN, CO 81611 273718102002 X 546 MCSKIMMING RD. ASPEN, CO 81611 08/08/2019 0190.2019.ARBK KARIN G LLC 546 MCSKIMMING 273718102002 106462# City of Aspen Version 11.3 Updated December 13, 2017 PROJECT ADDRESS:546 MCSKIMMING ROAD ASPEN CO 81611 Parcel ID #: 273718102002 Permit Number: Collector Aspect, Degress from True South Collector Tilt, Degrees From Horizontal Solar Orientation Adjustment Factor DC side capacity (kW) Inverter capacity (kW) kW for credit kW Mitigation Credit Collector Group 1 48 12 91.00%13.53 13.12 13.12 11.94 kW Collector Group 2 128 12 79.95%1.65 1.6 1.6 1.28 kW Collector Group 3 87.00%0 0.00 kW Collector Group 4 87.00%0 0.00 kW Collector Group 5 87.00%0 0.00 kW Collector Group 6 87.00%0 0.00 kW Collector Group 7 87.00%0 0.00 kW Collector Group 8 87.00%0 0.00 kW Collector Group 9 87.00%0 0.00 kW Collector Group 10 87.00%0 0.00 kW Collector Group 11 87.00%0 0.00 kW Collector Group 12 87.00%0 0.00 kW Collector Group 13 87.00%0 0.00 kW Collector Group 14 87.00%0 0.00 kW Collector Group 15 87.00%0 0.00 kW Collector Group 16 87.00%0 0.00 kW Collector Group 17 87.00%0 0.00 kW Collector Group 18 87.00%0 0.00 kW Collector Group 19 87.00%0 0.00 kW Collector Group 20 87.00%0 0.00 kW Total:13.22 kW $ Mitigation Credit:($90,748.85) Instructions: 1)Determine how many collector groups you have. Groups are used to differentiate between collectors (panels) with different tilts, aspects, sizing, or inverters. If all your collectors are installed similarily, you might have just one group. 2)Enter the aspect and tilt for each group. The solar orientation adjustment factor is automatically calculated. 3)DC side capacity is the total labled panel output kW in a group. 4)Inverter capacity is the recommended input power in kW of your inverter(s). 5)You will be given credit for the lesser of the labeled panel output or the inverter. 6)The kW for credit is multiplied by the solar orientation adjustment factor to get kW mitigation credit. 7)The kW mitigation credit is totalled and multiplied by $6865.32/kW to get the $ Mitigation Credit 8)The mitigation credit will be automatically entered into your RREMP or CREMP form. If your project has both RREMP and CREMP, it will automatically divide the credits up, with priority given to mitigating the CREMP payment. PREPARED BY:Date:25-Sep-19 Print Name:Green Electrical Solutions / JAY BURE Signature: Phone & EMail:970.927.8658 JAY@GREENELECTRICAL.SOLUTIONS REVIEWED:Date: 25-Sep-19 10/01/2019 0190.2019.ARBK 10/02/2019 tonyf DAM 10/14/19 3