Loading...
HomeMy WebLinkAboutFile Documents.RACE ST.0197.2019.ARBK0197-2019-ARBK_BuildingComment1 Subject: PlanCheck Page Label: [1] 17.001C Race Alley PLANS-S1.01 Author: stephenk Color: File Name: 541 Race - Gas Line Routing Rudd.pdf Gas line shall not penetrate foundation wall below grade. 2015 IFGC 404.6 Revisions to structural plans shall be made by engineer of record. Protect gas meter from ice and snow. 541 Race - Gas Line Routing Rudd.pdf (1) Subject: PlanCheck Page Label: [1] S1.02 Author: stephenk Color: File Name: Floor Framing revisions Race Alley - S1 02 REV 2.pdf revise detail 9/S5.02 to show new framing Floor Framing revisions Race Alley - S1 02 REV 2.pdf (1) T.O. SLAB = 89'-714" 8" CONC BASEMENTWALL - TYP U.N.O.8" CONC FOUNDATIONWALL w/ #5 @ 12"o.c.EA WAY CTRD - TYPU.N.O. 5 S5.01 T.O. WALL103'-0" T.O. FOOTING100'-0" T.O. WALL 99'-5"T.O. LEDGE99'-5" T.O. WALL 99'-1114"T.O. WALL 99'-438" T.O. WALL 99'-9" T.O. FTG 93'-0" T.O. FTG 97'-0" T.O. FTG 97'-0" T.O. WALL 101'-10" W10 CONT STAIRSTRINGER T.O. WALL 100'-0" T.O. LEDGE 98'-712" T.O. WALL 103'-0"3'-414"CONC CURB PER 4/S5.01TYP - LOCATE PER ARCH FC16 - TYP @ GARAGE T.O. CURB 89'-714" 26'-8"10'-1"22'-0" 3'-8"11'-812" 11'-8" 6'-8"8" RE: 7/S 2. 0 TYP @ 9STL CO L A B O V E 10 S5.01 FC24 - TYP @ BASEMENT WALL T.O. FTG 88'-1114" T.O. FTG 88'-1114" 3'-8" T.O. WALL 100'-914" T.O. FTG 88'-1114" T.O. WALL100'-0" T.O. WALL 99'-4" TYPICAL SLAB ON GRADE4" CONCRETE SLAB ON INSUL PER ARCH ONAPPROVED NATIVE OR PREPARED SUBGRADE PERGEOTECH REPORT. REINFORCE SLAB WITH6x6-W2.1xW2.1 WWF OR #3 @ 12"o.c EA WAY - CENTERED. PROVIDE 114" DEEP SAW-CUTCONTROL JOINTS @ 12'-0" o.c. MAX EACH WAY - TYP T.O. LEDGE 99'-1012"TYP U.N.O. 8" WINDOW WELL WALLw/ #5 @ 12"o.c. EA WAYCTRD w/ TAPERED TOPPER ARCH - TYP 8" W x 2'-0" DP CONC HDR MIN w/(2) #5 T&B AND #5 @ 12"o.c. HORIZE.F. w/ #3 TIES @ 12"o.c. - TYP @ 2 B.O. CONC HDR PERARCH - TYP @ 2 4'-9" T.O. WALL 100'-0"T.O. LEDGE FORGRATING PER ARCH T.O. LEDGE FORGRATING PER ARCH 12S5.01 T.O. SLAB = 102'-6"SLOPE TO DRAIN T.O. LEDGE101'-10" T.O. LEDGE 99'-812" 12" DP x 6'-6" WIDE CONC FTG w/#5 @ 16"o.c. T&B EA WAY TYP (2)SIDESCONC BUTTRESSWALL w/ #5 @12"o.c.EA WAY E.F. Gas line shall not penetrate foundation wallbelow grade. 2015 IFGC 404.6 Revisions to structural plans shall be madeby engineer of record. Protect gas meter from ice and snow. LAUNDRY HALL W10x39 - 2x NA T.O. STL = 99 W10x68 CO STAIR STR W10x39 W10x22 ROOFING ASSEMBLY w/ WATERPROOFING & FLASHING PER ARCH 9 S5.02 11 S5.02T.O. PLY = 99'-658" P.T. 2x8 @ 16"o.c. 11'-8" D STRUCTURE FY S.E.O.R. OF SIGN PRIOR TO S. (2) 714" LVL HU48 2 revise detail 9/S5.02 to show new framing