Loading...
HomeMy WebLinkAboutFile Documents.534 E Cooper Ave.0003.2017 (17).ACBKDesign Judgment www.blazeframe.com 1. I-Beam – Structural I-Beam dimensions and thickness by others 2. Spray Applied Fire Proofing – Spray applied fire proofing encasing I-Beam and filling voids between Z-Clips above and below I-Beam, thickness by others 3. Z-Clips – Min. 20ga z-clips extending through spray applied fire proofing attached to I-beam with typical steel fasteners max 16” O/C 4. Shaft Wall Assembly – Shaft Wall Assembly installed per U, V, or W400 series design in UL Fire Resistance directory 5. BlazeFrame – BlazeFrame J-runner profile attached to Z-clips with typical steel fasteners 6. Control Joint – (optional) Zinc or Vinyl control joint profile applied over rated gap per manufacturer’s installation instructions Notes: -UL listed sealant applied to seal any small gaps between spray applied fire proofing and BlazeFrame profile --UL listed sealant applied to seal any small gaps between spray applied fire proofing and finish side gypsum at bottom of wall (top of I-Beam) Note: BlazeFrame joint products have been tested as follows: ASTM E-119 & UL 2079 - Refer to System No's: HW-D-0631 & BW-S-0021 This Judgment represents a fire and smoke rated assembly expected to pass UL 2079 standards if tested Notice: The information contained herein is based upon internal and third party testing which we believe to be accurate. This information is provided for design purposes only and unless otherwise noted, relates to joint fire-resistance properties only. User must determine suitability of product and design to intended application. Installation of BlazeFrame product is beyond our control, BlazeFrame Industries only responsibility shall to be to refund or replace materials found to be defective as per our standard warranty. Design Judgement: 05221701 05/22/17 Shaft Wall Stairwell Bypass I-Beam -1 hour assembly shown = 1 layer per UL U, V, or W400 -2 hour assembly = 2 layers per UL U, V, or W400 Design 1 2 3 4 5 6 1 4 ________________________________________________________________________________________________________________________________________________ Project Name Detail for Review ______________________________________________________________________________________________________________________________________________ Location _______________________________________________________________________________________________________________________________________________ Installer/Architect Jim Klein, Director Technical Services ______________________________________________________________________________________________________________________________________________ Prepared By 534 East Cooper Boogies Building Bill Poss Architecture