HomeMy WebLinkAboutFile Documents.534 E Cooper Ave.0003.2017 (3).ACBKH/PHEAT/PHOTOELECTRIC SMOKE DETECTORELECTRICAL LEGEND(NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT)RECESSED OR SURFACE DOWNLIGHTWALL MOUNTED LIGHT FIXTURERECESSED FLUOR. LIGHT FIXTURESURFACE FLUOR. LIGHT FIXTUREAaAaFIXTURE DESIGNATIONS: UPPER CASE - FIXTURE TYPE LOWER CASE - SWITCH DESIGNATIONSHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUPFLUORESCENT STRIP FIXTURETRACK LIGHT AS NOTED OR SCHEDULEDWALL WASHERPOLE-MOUNTED FIXTUREPOST (BOLLARD) FIXTURECEILING OR WALL MOUNTED EXIT LIGHTEMERGENCY BATTERY LIGHTSDUPLEX RECEPTACLE @ 18" UNLESS NOTEDDOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTEDSPECIAL OUTLET AS NOTEDFLUSH FLOOR DUPLEX RECEPTACLEDUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTEDTELE-POWER POLEJUNCTION BOX IN FLOOR, CEILING OR IN WALLMULTI-OUTLET PLUG STRIPJJJCOMPUTER/TELEPHONE OUTLET IN FLOOR OR WALLCONDUIT RUN CONCEALED IN WALL OR ABOVE CEILINGTELEPHONE BACKBOARDCIRCUIT HOMERUNCONDUIT RUN BELOW FLOOR OR GRADECONDUIT STUB-UP - CAP & MARKLIGHT SWITCH AT 46" UNLESS NOTEDSUBSCRIPTS:2 = 2-POLE SWITCH3 = 3-WAY SWITCH4 = 4-WAY SWITCHK = KEY-OPERATED SWITCHTO = THERMAL OVERLOAD SWITCHP = SWITCH WITH PILOT LIGHTDIMMER SWITCH W/ WATTAGEMAGNETIC MOTOR STARTERDISCONNECT SWITCHPANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTEDSWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION BOARDTRANSFORMERGROUNDPUSHBUTTON CONTROL STATIONPHOTOELECTRIC CELLTIME SWITCHTHERMOSTAT AT 60" UNLESS NOTEDDIVISION 15 EQUIPMENTCIRCUIT BREAKERMOTOR OUTLETAUTOMATIC TRANSFER SWITCHFOOD SERVICE EQUIPMENTDTPCTSTMATSABBREVIATIONS- ABOVE COUNTERACAFF- ABOVE FINISHED FLOOR- ABOVE FINISHED GRADEAFG- ALUMINUMAL- EMERGENCYEM- GROUNDGND- GROUND FAULT INTERRUPTERGFINIC- NOT IN CONTRACTNL- NIGHT LIGHTNTS- NOT TO SCALEUG- UNDERGROUNDWP- WEATHER PROOFXFMR- TRANSFORMER+18"- MOUNTING HEIGHT TO CENTERLINE OF DEVICE AFF OR AFGFIRE ALARM SYSTEMFIRE ALARM CONTROL PANELANNFIRE ALARM ANNUNCIATOR PANELFIRE ALARM PULL STATIONALARM HORN OR SPEAKERCOMBINATION HORN/STROBE OR SPEAKER/STROBETHERMAL HEAT DETECTORHSMOKE/IONIZATION DETECTORIPHOTOELECTRIC SMOKE DETECTORPDUCT DETECTORSRSPRINKLER SYSTEM FLOW SWITCHSPRINKLER SYSTEM TAMPER SWITCHSTROBESMOKE/FIRE DAMPER CONNECTIONREMOTE INDICATOR LIGHTFDCOMMUNICATION SYSTEMSPEAKER IN CEILING OR WALLVOLUME CONTROL AT 60" UNLESS NOTEDMICROPHONE OUTLET IN FLOOR BOX OR WALLMMCALL-IN SWITCHCPROGRAM BELLINTERCOMCLOCKVISSBAAMPLIFIERTELEVISION OUTLETCONTACT DOOR SWITCH IN JAMB OR HINGESECURITY SYSTEMDCINTRUSION MOTION DETECTOR AS SPECIFIED, CORRIDOR/ROOMPC OR RKEY-OPERATED ACCESS SWITCHKSURVEILLANCE CAMERADISTRIBUTION EQUIPMENT SYMBOLSDISCONNECT SWITCHFUSESCIRCUIT BREAKERCURRENT TRANSFORMERTRANSFORMERMETERMCU- COPPERSTEP LIGHTFACPM = MOTION-OPERATED SWITCHPOP-UP RECEPTACLE- ELECTRICAL CONTRACTOREC- AUTHORITY HAVING JURISDICTIONAHJ- MECHANICAL CONTRACTORMC- PLUMBING CONTRACTORPCUTP- UNSHIELDED TWISTED PAIR- GENERAL CONTRACTORGC- REFERENCEREF1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLYSHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUALU300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY ANDSHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATEDASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATESAND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEPCHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUAREOR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENERTYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIESDESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM).2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY ORECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT ORTUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM(OR SMALLER) STEEL ELECTRICAL METALLIC TUBING3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN.(16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES,RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM)DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACTLOCATION ON BOTH SIDES OF WALL.THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATINGOF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE.THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THEPIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED,AS TABULATED TO THE LEFT.3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT,*BEARING THE UL CLASSIFICATION MARKINGPENETRATION THROUGH A FIRE-RATED WALLCABLE TV ONE LINE DIAGRAMUNO- UNLESS NOTED OTHERWISE2"C PVC WITH PULLWIREBURIED 20" BELOW GRADECATVPEDESTALCOAX RECEPTACLE IN SINGLEGANG BOX @ 18" A.F.F. UNOQUANTITIES PER FLOOR PLANS(RG6 QUAD SHIELDED CABLE) 1"CSTRUCTURED CABLEDISTRIBUTION PANEL#6 CU GMETALLIC COLDWATER PIPENOT TO SCALENO SCALE14. All cabling shall be bundled and properly secured and terminated.The warranty period shall begin at the point of system acceptancesystem during this warranty period at no additional cost to the owner.free of defects of workmanship or products and will inspect and repair the from the date of project completion. The contractor warrants the system to be 15. The warranty set forth for this system shall consist of a full three (3) years or beneficial use, whichever comes later.Coordinate numbering scheme with owner.13. No exposed wiring will be accepted unless approved in writing by the Engineer.Care must be taken to ensure cables are not kinked, bent beyond limit, including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. familiar and install in accordance with all applicable codes and standards, 12. All cable hangers shall be no more than 48" apart. Contractor shall be 11. Cable bends shall be no less than eight times the cable diameter or 1.00". termination. No more than .5 inches of exposed untwisted pairs shall be the extent in which each twisted pair is unraveled at the point of its physical 10. All connections of twisted wiring shall be made in such a way as to minimize length of the run. Splices and bridge taps with cabling are strictly prohibited. Cabling shall be free from tension at both ends, as well as through out the 9. All wiring shall be protected from moving mechanical or physical contacts. Bidder will identify any cable runs exceeding 90 meters8. Route cables so as not to exceed 90 meters in length.In the case of "hard" drywall ceilings, adequate support shall be accomplished independent hangers. Cable "draped" across ceiling tiles is unacceptable.7. All cable above the ceiling must be tied and properly supported with 6. Provide plenum rated cable when required by article NEC 300-22.overloaded, over-cinched, crushed, improperly untwisted, etc.present at these locations.Wiring is to be run in cable tray and conduit where specified. and provide solution to meet the 90 meter requirement.where reasonably possible.patch panel location, and each wall/floor faceplate that has wiring installed. 5. All cables will be labeled with self-laminating labels at each cable end, at each match faceplates to power, color coded for voice and data, match to cable modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent jacks, 3. The terminations at the station locations must be Category 6, T568B (AT&T) 2. Data cable will be colored blue. Voice cable will be colored white.manufacturers include: Berk-Tek, Belden, Lucent or equivalent. 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable 1. The cabling for voice and data must be continuous, home run, non-spliced, 4. Wall mounted patch panels will be provided.Outlets will be securely held in place.B. Cat 6 Wiring Requirementsenclosed within cable trays, raceways or conduit, as specified.Cabling shall be in the wall, above the ceiling or where exposed, equipment, etc. furnish by mechanical - refer to both electrical andelectrical apparatus as shown on single line diagram and drawings. and mechanical drawing for scope and work and additional information.Complete connection of HVAC/Plumbing motor(s), water heater(s),Fire alarm system will be by electrical contractor.Complete provision, installation and connection of lighting fixtures,exit signs and lamps as specified and as shown on drawings.Complete branch circuit wiring required for the connection ofemergency lighting and exit signs to existing emergency standComplete feeder(s) installation as required for new and/ornew control devices, etc. for a complete lighting and power system.including new panelboards, new conduits, new wires, new wiring devices,Complete wiring system for new lighting and power as shown,Electrical work shall include, but not limited to, these major items:indicated on drawing and as specified, as necessary to complete the contract.SCOPE:g.c.d.f.e.Provide grounding and bonding Facilities.Complete all electrical demolition as required.B.ELECTRICAL SPECIFICATIONS1.by power system.b.a.A.Contractor shall submit shop drawings for engineer review and approval. MC cable permitted per local codes. Run hard pipe from panel to local Lighting fixtures.Shop drawing submittal shall include:Panelboard(s).CONDUIT AND WIRE:B.5.A.B.b.a.and contractor shall have written approvals from building owner priorCore drilling and patching of existing building structure required for Operating, Maintenance and identification instructions manuals,electrical work. Core drilling shall follow Building Standard proceduresApplicable codes: National Electric Code (2014)PERMITS AND FEES: requirements of Federal, State or other City agencies having jurisdiction.Local Electrical Code, pertinent NFPA publications and to theConform to the prevailing edition and amendments thereto of theSHOP DRAWINGS AND SUBMITTAL:if any to start of any work.Test of entire system and work.REGULATIONS AND CODES:4.A.2.h.3.A. General Requirements6.Finish per owner or architect.Convenience receptacles will be 15 A, decora style. Light switches will be 20 amp, commercial grade, decora style.B.ELECTRICAL DEVICES:A.Finish per owner or architect.Finish per owner or architect.Dimming switches will be a minimum of 600w or as noted, provide decora style.C.7.All mounting heights will conform to ADA guidelines. D.Typical receptacle heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise.Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc.as required by code.E.junction box, and run MC cable from junction box to device.CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, usecoppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only copper wire with 600V insulation, types TW, THHN, or THW - stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14,stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only.Support all electrical equipment independent of accessible ceilings as required by NEC.SUPPORT:A.A. Obtain and pay for all necessary permits, inspections, examinations and feesor charges necessary for execution and completion of electrical work.A. Furnish all materials and labor required to execute this work asand contractor shall have written approvals from building owner priorCore drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard proceduresi.j.Provide tamper proof receptacles at all residential areasas required by code.F.Test of entire system and work.i.DTJTV18" (1'-6")
46" (3'-10")
48" (4'-0")
80" (6'-8")TYPICAL DEVICEMOUNTING HEIGHTSMAIN CIRCUIT BREAKER &BRANCH CIRCUIT BREAKERSMAXIMUM MOUNTING HEIGHTIS 79", MINIMUM IS 18".NOT TO SCALENOTES:1.HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOXUNLESS NOTED OTHERWISE.2.DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE.3.MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONSAND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERNOVER THOSE SHOWN ABOVE.4.FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARMNOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF OTHERWISE INSTALL AT 6" BELOW CEILING.5.MOUNTING HEIGHTS PER IBC 2009 AND ADA CODESFINISHED FLOORTYPICAL 8'-0" CEILING+80"AFFP+80"AFFTELEPHONE ONE-LINE DIAGRAMTELEPHONE/COMPUTER ROUGHIN#6 CU GSTRUCTURED CABLEDISTRIBUTION PANEL(2 #CAT 6) 1"CPLENUM RATED WIREWHEN REQUIRED(1) RJ-11 & (1) RJ-45IN SINGLE GANG BOXAT 18" AFF UNOCOLD WATER PIPEMAIN TELE/DATA ROOM(PULLWIRE) 4"CNO SCALEROUTE CONDUIT AT CEILING PARALLELOR PERPENDICULAR TO STRUCTURE.SECURE TO STRUCTURE AT4' INTERVALS OR LESS.GENERAL NOTES ALL SHEETSTHE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITHTHE OWNER/ARCHITECT PRIOR TO FINAL ROUGH-IN AS FOLLOWS:·CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF FOUND NECESSARY.·REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED.·REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW.MOVE AS REQUIREDIN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS.THE ELECTRICIAN SHOULD BE PREPARED TO REWORK SOMEDEVICE LOCATIONS. SIGNIFICANT REWORK SHOULD BE FLAGGED ANDUNIT PRICING PROVIDED AND WRITTEN AUTHORIZATION FORADDITIONAL COSTS APPROVED PRIOR TO PROCEEDING.77ZBGSOHELECTRICALSPECS,LEGEND &ONE-LINESE1.017ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7
MTRETAIL APANEL200/3UTILITYTRANSFORMERPAD MOUNTEDMETERBANK1200A, 120/208V, 3P, 4W65K AIC2[(8 #400 MCM CU) 4"C]ELECTRICAL ONE-LINE DIAGRAMNO SCALENOTE:PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED AT ONE-LINE,NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION ACCEPTABLE,SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW.M2[(4 #350 MCM CU, 1 #3 CUG) 4"C]OR 2[(4 #500 MCM AL, 1 #1/0 ALG) 4"C]600/3RETAIL BPANEL200/3RETAIL CPANEL200/3RETAIL DPANEL250/3150/3-STELEVATOR A150/3-ST125/3-STMELEVATOR BMELEVATOR CTO FUTURE METERBANK SECTIONSPARE 1 1/2"C WITH PULLWIRE FOR FUTURECONDENSING UNITS, TYPICAL OF 10(3) #1 CU, (1) #6 CU GND - 1 1/2"CFUTURE RETAIL PANELSPROVIDE CONDUIT ONLY200/3 30 HP30 HP25 HPPROVIDE METER SOCKET AND SPACEONLY FOR THE CIRCUIT BREAKER14. All cabling shall be bundled and properly secured and terminated.The warranty period shall begin at the point of system acceptancesystem during this warranty period at no additional cost to the owner.free of defects of workmanship or products and will inspect and repair the from the date of project completion. The contractor warrants the system to be 15. The warranty set forth for this system shall consist of a full three (3) years or beneficial use, whichever comes later.Coordinate numbering scheme with owner.13. No exposed wiring will be accepted unless approved in writing by the Engineer.Care must be taken to ensure cables are not kinked, bent beyond limit, including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. familiar and install in accordance with all applicable codes and standards, 12. All cable hangers shall be no more than 48" apart. Contractor shall be 11. Cable bends shall be no less than eight times the cable diameter or 1.00". termination. No more than .5 inches of exposed untwisted pairs shall be the extent in which each twisted pair is unraveled at the point of its physical 10. All connections of twisted wiring shall be made in such a way as to minimize length of the run. Splices and bridge taps with cabling are strictly prohibited. Cabling shall be free from tension at both ends, as well as through out the 9. All wiring shall be protected from moving mechanical or physical contacts. Bidder will identify any cable runs exceeding 90 meters8. Route cables so as not to exceed 90 meters in length.In the case of "hard" drywall ceilings, adequate support shall be accomplished independent hangers. Cable "draped" across ceiling tiles is unacceptable.7. All cable above the ceiling must be tied and properly supported with 6. Provide plenum rated cable when required by article NEC 300-22.overloaded, over-cinched, crushed, improperly untwisted, etc.present at these locations.Wiring is to be run in cable tray and conduit where specified. and provide solution to meet the 90 meter requirement.where reasonably possible.patch panel location, and each wall/floor faceplate that has wiring installed. 5. All cables will be labeled with self-laminating labels at each cable end, at each match faceplates to power, color coded for voice and data, match to cable modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent jacks, 3. The terminations at the station locations must be Category 6, T568B (AT&T) 2. Data cable will be colored blue. Voice cable will be colored white.manufacturers include: Berk-Tek, Belden, Lucent or equivalent. 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable 1. The cabling for voice and data must be continuous, home run, non-spliced, 4. Wall mounted patch panels will be provided.Outlets will be securely held in place.B. Cat 6 Wiring Requirementsenclosed within cable trays, raceways or conduit, as specified.Cabling shall be in the wall, above the ceiling or where exposed, equipment, etc. furnish by mechanical - refer to both electrical andelectrical apparatus as shown on single line diagram and drawings. and mechanical drawing for scope and work and additional information.Complete connection of HVAC/Plumbing motor(s), water heater(s),Fire alarm system will be by electrical contractor.Complete provision, installation and connection of lighting fixtures,exit signs and lamps as specified and as shown on drawings.Complete branch circuit wiring required for the connection ofemergency lighting and exit signs to existing emergency standComplete feeder(s) installation as required for new and/ornew control devices, etc. for a complete lighting and power system.including new panelboards, new conduits, new wires, new wiring devices,Complete wiring system for new lighting and power as shown,Electrical work shall include, but not limited to, these major items:indicated on drawing and as specified, as necessary to complete the contract.SCOPE:g.c.d.f.e.Provide grounding and bonding Facilities.Complete all electrical demolition as required.B.1.by power system.b.a.A.Contractor shall submit shop drawings for engineer review and approval. MC cable permitted per local codes. Run hard pipe from panel to local Lighting fixtures.Shop drawing submittal shall include:Panelboard(s).CONDUIT AND WIRE:B.5.A.B.b.a.and contractor shall have written approvals from building owner priorCore drilling and patching of existing building structure required for Operating, Maintenance and identification instructions manuals,electrical work. Core drilling shall follow Building Standard proceduresApplicable codes: National Electric Code (2014)PERMITS AND FEES: requirements of Federal, State or other City agencies having jurisdiction.Local Electrical Code, pertinent NFPA publications and to theConform to the prevailing edition and amendments thereto of theSHOP DRAWINGS AND SUBMITTAL:if any to start of any work.Test of entire system and work.REGULATIONS AND CODES:4.A.2.h.3.A. General Requirements6.Finish per owner or architect.Convenience receptacles will be 15 A, decora style. Light switches will be 20 amp, commercial grade, decora style.B.ELECTRICAL DEVICES:A.Finish per owner or architect.Finish per owner or architect.Dimming switches will be a minimum of 600w or as noted, provide decora style.C.7.All mounting heights will conform to ADA guidelines. D.Typical receptacle heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise.Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc.as required by code.E.junction box, and run MC cable from junction box to device.CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, usecoppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only copper wire with 600V insulation, types TW, THHN, or THW - stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14,stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only.Support all electrical equipment independent of accessible ceilings as required by NEC.SUPPORT:A.A. Obtain and pay for all necessary permits, inspections, examinations and feesor charges necessary for execution and completion of electrical work.A. Furnish all materials and labor required to execute this work asand contractor shall have written approvals from building owner priorCore drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard proceduresi.j.Provide tamper proof receptacles at all residential areasas required by code.F.Test of entire system and work.i.(3) #1/0 CU, (1) #6 CU GND - 1 1/2"C(4) #3/0 CU, (1) #6 CU GND - 2"CPANEL HPANEL HAGENERAL NOTES ALL SHEETSTHE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITHTHE OWNER/ARCHITECT PRIOR TO FINAL ROUGH-IN AS FOLLOWS:·CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF FOUND NECESSARY.·REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED.·REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW.MOVE AS REQUIREDIN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS.THE ELECTRICIAN SHOULD BE PREPARED TO REWORK SOMEDEVICE LOCATIONS. SIGNIFICANT REWORK SHOULD BE FLAGGED ANDUNIT PRICING PROVIDED AND WRITTEN AUTHORIZATION FORADDITIONAL COSTS APPROVED PRIOR TO PROCEEDING.x99,500 AICx55,038 AICx14,038 AICx28,000 AIC1200/3KRP-C(3)1200Ax14,038 AICx14,038 AICx14,038 AICx21,504 AICx18,876 AICMREUSE (2) 4" PVC-40 CONDUITS.REPAIR EXISTING CONDUITS. PULLNEW 400 MCM COPPER WIRE. 8SETS OF 400 MCM COPPER WOULDBE DERATED TO 80% OF THECONDUCTOR RATING PER NECTABLE 310.15(B)(3)(a). THIS SERVICEWOULD HAVE A RATING OF 4*380*.8 =1216 AMPS AT 120/208V 3P.BUSINESSPANEL200/3x14,038 AICELEVATOR RECALL DIAGRAMHTHE ELEVATOR SYSTEM INTO RECALL MODESHALL COMPLY WITH NFPA.SMOKE DETECTOR ATELEVATOR ROOM, ELEVATORLOBBY & SHAFTW/auxCONTACTS.HEAT DETECTOR LOCATEDAT ELEVATOR ROOM &ELEVATOR SHAFT W/auxCONTACTS.BUSSMANNPOWER MODULE2#14 FROM CONTACTS INMODULE TO FIRE ALARMCONTROL PANEL TOMONITOR SHUNT-TRIP (SEENFPA 72)ELEV. C.B.IN MDC2#14 FROM FIRE ALARMCONTROL PANEL HEATDETECTOR INTIATINGCIRCUIT FOR DEVICES IN THEELEVATOR MACHINE ROOMAND SHAFT.ELEVATORCONTROLLERTO ELEVATORMOTORNO SCALESERVICE GROUNDING DETAILNO SCALENGINCOMING WATER SERVICEPIPE(3) 3/4"x10' DRIVENGROUND RODS IFREQUIRED BYLOCAL AHJBONDING JUMPER#6 TO TELEPHONE/TVCONCRETE- ENCASED ELECTRODEREQUIRED IN FOOTING/FOUNDATION PERNEC 250-50. MINIMUM 20' #4 REBAR ORMINIMUM 20' #4 BARE COPPER. MUST BEINSTALLED AT FOOTING INSPECTION.WATER METERBUILDING STEELINCOMING GAS SERVICE PIPE(#3/0 CU G)3/4"C#6 CU2-1/2"C SPARE CONDUITWITH PULLWIRE FORFUTUREPANEL H17ZBGSOHELECTRICALONE-LINEDIAGRAM &SCHEDULESE1.127ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7
777777777ZBGSOHELECTRICALLOAD CALCSANDSCHEDULESE1.237ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7
SHEET DETAIL NOTES:ELEVATOR, VERIFY LOCATION, SEEELECTRICAL ONE-LINE DIAGRAM.ELEVATOR CONTROL, VERIFY LOCATION.ELEVATOR FAN, VERIFY LOCATION.ELEVATOR LIGHTS, VERIFY LOCATION.LIGHT, SWITCH, AND RECEPTACLE LOCATEDIN THE ELEVATOR ROOM, VERIFY LOCATION.LIGHT, SWITCH, AND RECEPTACLE LOCATEDIN THE ELEVATOR PIT, VERIFY LOCATION.PUMPS ARE TO BE LOCATED IN THEMECHANICAL ROOM, VERIFY LOCATIONS.12MGGGGGGG3456H1-14PANEL "HA"UPB1B2PANEL "H"TOTOH1-23MTOJTOP1TOP2TOP3TOP4aTOP4bTOP5P6TOH1-3377H1-31H1-29TO TV ANDTELEPHONEPEDESTALSEF3UH3KSF1H-5,7MTOH-22PANEL "H1"H1-21PP2EF2EF1MTOMTOJUH3KH-1,3MDDAAMDAADDHOME-RUN TOUPPER LEVELTENANT PANELMHA-2REFERENCE MECHANICAL PLANS FORLOCATIONS OF EQUIPMENT.GMTOH1-2PARTIALUH5HA-1HA-3TOTOPP3SF1MTOH-24H1-16PARTIALH1-16PARTIALH1-16PARTIALH1-16PARTIALH1-16PARTIALH1-16XCONNECT EGRESS LIGHTINGTO LOCAL LIGHTING CIRCUIT.TYPICAL.MGGGPARTIALSF1MTOH-22PARTIALGGGFSFSFSPROVIDE 120V POWER TOFIRE SMOKE DAMPERS.HOME RUN TO CIRCUIT HA-9HOME-RUN TOUPPER LEVELTENANT PANELFUTURE PANELBUSINESSFFFFD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRCONNECT DOWNLIGHTSTO CIRCUIT H1-17.NO SWITCHING, ON 24/7UH1UH2UH4UH7UH3UH6UH12JH1-2JH1-37JH1-35JH1-27JHA-31JH1-8JH1-6777777ELECTRIC DUCT HEATERSCHANGED TO HYDRONICHEATING COILS.ZBGSOHBASEMENTELECTRICAL PLANSCALE 1/4" = 1'-0"E2.047NORTHBASEMENT ELECTRICAL PLANSCALE: 1/4" = 1'0"ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7
1C1DECO COLUMN1M2HORIZ MULLION1M1HORIZ MULLION1C5DECO COLUMN1C4DECO COLUMN1C3DECO COLUMN1C2DECO COLUMN1M5HORIZ MULLION1M4HORIZ MULLION1M3HORIZ MULLIONBE3AE3AE31'-25'-36'-33'-634/25'-1058/14'-812/4'-312/4'-938/10'-010'-010'-03'-9914/1'-28'-612/1'-28'-612/18'-1134/81'-25'-101'-22'-034/3'-278/3'-838/212/458/634/714/914/434/DETAILA1234567891011A3ADET.DET.BDET.A MWP/GFIGH-26,28,30H1-19165H1-17MTO3H1-13STJ4H1-15STGGDD(EM)GUPDD(EM)DDDDDDDD(EM)DDCCCCCCCJ2H1-11SHEET DETAIL NOTES:ELEVATOR, VERIFY LOCATION.ELEVATOR CONTROL, VERIFY LOCATION.ELEVATOR FAN, VERIFY LOCATION.ELEVATOR LIGHTS, VERIFY LOCATION.LIGHT, SWITCH, AND RECEPTACLE LOCATEDIN THE ELEVATOR ROOM, VERIFY LOCATION.LIGHT, SWITCH, AND RECEPTACLE LOCATED INTHE ELEVATOR PIT, VERIFY LOCATION.AIR CURTAIN IS PART OF TENANT SPACE AND TOBE CIRCUITED TO FUTURE TENANT SPACE PANEL.TEMPORARY CIRCUIT TO HOUSE PANEL H.LOCATED IN SOFFIT ABOVE.EXISTING ELECTRICAL OUTLET AT TREE TO BEREUSED. REFERENCE LANDSCAPE PLANS FORTREE LOCATIONS.123456H1-18VIA PHOTOCELLFFDDH-25XXXXDA1A1FUTURE PANELRETAIL BDD(EM)DD(EM)DD(EM)HA-17,19H-8,10JJARC2ARC1JJXJFACPUH3KXDN7HA-8,1088DD(EM)DD(EM)HA-13,15JUH3KFFFFFFGJUH3KJUH2KJUH1.5KUH2KTO LIGHTSAT SECONDFLOORCELINGXX H-21,23HA-25,27HA-27MWP/GFIGH-32,34,36H1-916MTO3H1-3STJ4H1-5STJ2H1-1MWP/GFIG16MTO3J4J2XXHA-4,6XXXDDDDPANEL DPANEL DPANEL DPANEL DPANEL DPROVIDE RACEWAY ONLY FORELEVATOR C EQUIPMENT. WIREAND CIRCUITS WILL BE BY TENANT.WP/GFIH1-22PARTIALH1-22PARTIALH1-22PARTIALCONNECT EGRESS LIGHTINGTO LOCAL LIGHTING CIRCUIT.TYPICAL.DD(EM)DD(EM)JSF2H-2099999FSPROVIDE 120V POWER TOFIRE SMOKE DAMPERS.HOME RUN TO CIRCUIT HA-9NEW SERVICE UNDERGROUNDTO EXISTING UTILITY TRANSFORMERREUSE EXISTING (4) LUG SETS ATTHAT TRANSFORMER.HOUSECTS HOUSETAPMAIN LUGSTENANT METERSTENANT DMETERHOUSEDISCONNECTFUTUREMETER07/23/19 REVISED GEAR LAYOUTTO MATCH UP WHERE MAINSERVICE CONDUITS COME UP.EC TO CONFIRM COORDINATIONWITH MECHANICAL AND PLUMBING.FUTURE PANELRETAIL AX
X XXGG20A1PH-41G33FFUP TO NEXTLEVEL3D-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRD-FRCONNECT DOWNLIGHTSTO CIRCUIT H1-17.NO SWITCHING, ON 24/7UH8UH9UH11UH10JH1-10JHA-11JHA-29JHA-12,1477777ELECTRIC DUCT HEATERSCHANGED TO HYDRONICHEATING COILS.ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7ZBGSOH1st FLOORELECTRICALPLANSCALE 1/4" = 1'-0"E2.157NORTH1st FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'0"
FXDNX3PANELFUTURE RETAIL CDDDH1-36DDFUTURE PANELRETAIL DELGEF5EF4MTOMTODDDXX XXXGCONNECT EGRESS LIGHTINGTO LOCAL LIGHTING CIRCUIT.TYPICAL.HA-16,18JUH4KHA-20,22JUH4KHA-24,26JUH4KHA-28,30JUH4KHA-32,34JUH4KHA-36,38JUH4KX XFSFSPROVIDE 120V POWER TOFIRE SMOKE DAMPERS.HOME RUN TO CIRCUIT HA-9FFFFFFFDOWN TONEXT LEVELX
X
XGGGFFF33FF33JSF4H1-6PARTIALD-FRD-FRD-FRD-FRD-FRCONNECT DOWNLIGHTSTO CIRCUIT H1-17.NO SWITCHING, ON 24/7UH13UH15UH16JHA-33JHA-35JHA-37JHA-40,42777UH117ELECTRIC DUCT HEATERSCHANGED TO HYDRONICHEATING COILS.ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7ZBGSOH2nd FLOORELECTRICALPLANSCALE 1/4" = 1'-0"E2.267NORTH2nd FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'0"
WPGFIWPGFIWPGFIH1-41SHEET DETAIL NOTES:PROVIDE HEAT TAPE ROUGH-INS ATTHE ROOF DRAINS, VERIFY LOCATIONS.VERIFY LOCATION WITH THEMECHANICAL EQUIPMENT.12222WPJHEATTAPEWPJHEATTAPEWPJHEATTAPEWPJH1-40,42HEATTAPEWPJHEATTAPEWPJHEATTAPE111111AT EACH EQUIPMENT PAD STUB AND CAP FUTURE1-1/2"C FOR FUTURE CONDENSING UNIT. REFERENCECONDENSING UNIT CUT SHEETS TO CONFIRM CONDUITLOCATION, ADJUST AS NEEDED. ROUTE CONDUIT TORESPECTIVE PANELS AS SHOWN ON THE ELECTRICALONE-LINE DIAGRAM, SHEET E1.1.TYPICAL OF 8.LOCATE (2) 1-1/2"C & (3) 3/4"C SLEEVESFOR FUTURE. CAP AT EACH END. LABEL"SPARE". FIELD LOCATE TO BESTDETERMINED LOCATIONLOCATE (2) 1-1/2"C & (3) 3/4"C SLEEVESFOR FUTURE. CAP AT EACH END. LABEL"SPARE". FIELD LOCATE TO BESTDETERMINED LOCATIONAT EACH EQUIPMENT PAD STUB AND CAP FUTURE1-1/2"C FOR FUTURE CONDENSING UNIT. REFERENCECONDENSING UNIT CUT SHEETS TO CONFIRM CONDUITLOCATION, ADJUST AS NEEDED. ROUTE CONDUIT TORESPECTIVE PANELS AS SHOWN ON THE ELECTRICALONE-LINE DIAGRAM, SHEET E1.1.TYPICAL OF 8.ofwww.aec-vail.com
a
PO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone: 970-748-8520
ceDrawn By:Checked By:DATE:ISSUE:AEC PROJECT #:BOOGIE'S BUILDING
534 EAST COOPER
ASPEN, CO 8161115075.02An Office with LEED™ Accredited Professionals08-14-19RFI # 032809-04-19CO#2 COMMENTS09-15-19ROOF EQUIPMENT09-26-19ROOF PEN. PRELIM.11-25-19CO #2 CLARIFICATION7ZBGSOHROOFELECTRICALPLANSCALE 1/4" = 1'-0"E2.377NORTHROOF ELECTRICAL PLANSCALE: 1/4" = 1'0"