Loading...
HomeMy WebLinkAboutFile Documents.534 E Cooper Ave.0003.2017 (16).ACBKA A L L 11 1111MAILBOX20' - 6"20' - 4"20' - 4 1/8"18' - 8 1/4" 7926 7927 7928792879287927PROPERTY LINEPROPERTY CORNER PROPERTY CORNER PROPERTY LINE HUNTER STREET COOPER STREETALLEY1 5/8" COLOR TO START AT EAST EDGE OF COLUMNS AT SCORE LINE THAT IS ALIGNED TO THE EAST FACE OF COLUMN. COLOR ENDS AT THE EDGE OF THE WALKING SURFACE ALIGNED WITH THE NORTH EDGE OF THE COLUMN. SCORE LINE CENTERED ON DOOR SCORE LINE CENTERED ON DOOR SCORE LINE CENTERED INSIDE DOOR JAMB SCORE LINE CENTERED INSIDE DOOR JAMB CONTINUE TO CURB CONTINUE SCORE LINE FROM EDGE OF SOD AREA CENTERED ON EDGE. STOP HERE THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE ALIGNED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP COLOR TO START AT EAST EDGE OF COLUMNS AT SCORE LINE THAT IS ALIGNED TO THE EAST FACE OF COLUMN. THIS SCORE LINE MUST BE ALIGNED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP EQ EQEQEQ EQ EQ THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP SCORE LINE CENTERED ON DOOR THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP EQ EQ EQ THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE EDGE OF THE CURB. ONCE THIS CURB LINE IS ESTABLISHED, IT IS IMPARATIVE THAT THE ARCHITECT BE CONTACTED TO REVIEW ITS LOCATION IN RELATION TO AS-BUILT CONDITIONS! THE DIMENSIONAL RELATION OF THIS SCORE LINE TO THE BUILDING MUST MATCH THE SAME RELATION THAT THE PERPENDICULAR SCORE LINE HAS TO THE BUILDING. THIS WAY THRER CAN BE A POINT ON THE CORNER OF THE PINK AREA AS SHOWN. CONTACT THE ARCHITECT WHEN YOU START TO LAYOUT THESE SCORE LINES. THIS NEEDS TO BE A POINT. CONTACT ARCHITECT TO ESTABLISH RELATION TO BUILDING AND CURB. ONCE ADJACENT POINTS OF REFERENCE HAVE BEEN ESTABLISHED. CENTER SCORE LINE ON ENTRY DOOR. CENTER STREET LIGHT EQUAL DISTANCE FROM EACH EDGE OF WALKING SURFACE CONTINUE SCORE LINE OFF OF CURB AND EDGE OF SOD AREA. THIS SCORE LINE MUST BE CENTERED ON THE EAST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE WEST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE WEST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE EAST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE WEST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE EAST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE WEST SIDE OF THE STEEL COLUMN WRAP COLOR TO START AT SOUTH EDGE OF COLUMNS AT SCORE LINE THAT IS ALIGNED TO THE EAST FACE OF COLUMN. CENTER SCORE LINE ON CENTER OF DOOR. THIS SCORE LINE MUST BE CENTERED ON THE EAST SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE WEST SIDE OF THE STEEL COLUMN WRAP AS CURB SWINGS OUT INTO THE STREET. CONTINUE THE SIDEWALK STRAIGHT FROM THE BACK SIDE OF THE CURB. CONTINUE THIS SCORE LINE INTO THE PINK CONC AREA AS SHOWN. THIS WILL BE VERY CLOSE TO CENTER OF THE PINK AREA, BUT NOT EXACT. EQ EQ THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE NORTH SIDE OF THE STEEL COLUMN WRAP THIS SCORE LINE MUST BE CENTERED ON THE SOUTH SIDE OF THE STEEL COLUMN WRAP CONTINUE THIS SCORE LINE FROM EDGE OF THE SOD AREA TO THE NEXT CORNER OF THE SOD AREA. THIS LINE SHOULD BE STRAIGHT AND PARALLEL TO THE BUILDING. CONTINUE THIS SCORE LINE FROM EDGE OF THE SOD AREA TO THE LINE PROJECTED FROM THE EDGE OF THE RAMP PAD CONTINUE THIS SCORE LINE FROM EDGE OF THE SOD AREA TO THE LINE PROJECTED FROM THE EDGE OF THE RAMP PAD RAMP PAD RAMP PAD EQEQCENTER SCORE LINE BETWEEN THE PARALLEL ADJACENT SCORE LINES. THIS SCORE LINE MUST SPRING FROM THE CENTER OF THE DOOR AND CONTINUE EAST TO THE SOD AREA PARALLEL TO THE SOUTH FACADE THIS SCORE LINE MUST SPRING FROM THE CENTER OF THE DOOR AND CONTINUE SOUTH TO THE SOD AREA PARALLEL TO THE EAST FACADE EQEQCENTER SCORE LINE ON WINDOW. SCORE LINE CENTERED ON RAMP PAD SCORE LINE RUND CONTINUOUS PARALLEL TO THE FACADE OF THE BUILDING FROM THE SIDE OF THE RAMP PAD.EQEQEQEQSCORE LINE 45 DEGREES OFF CORNER 30"30" LIGHT BASE EDGE ALIGNED WITH RAMP PADS3' - 0"3' - 0" THIS 3'-0" X 5'-0" SECTION WILL BE 6" THICK. 5' - 0"1' - 4" PARKING METER CLEARANCE FROM BACK OF METER TO THE CURB 10"10" 48 DENIS MURRAY CLEARED THE LARGER BENCH WITH ZONING. THIS IS TO COMPLY WITH ICC A117.1-2009 SECTION 903.37' - 4"1' - 8"48 48 48 NORTH Consultant ARCHITECTURE PLANNING+ ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 SHEET TITLE BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. c 2016 PROJECT NO: Issue: SCALE:11/13/2019 9:45:57 PM 1/4" = 1'-0" 534 EAST COOPER ASPEN, CO A001a SITE WORK 21512.00 SCALE 1/4" = 1'-0"1 SIDEWALK SCORE LINES 43 09.16.2019 RFI 042 48 09.24.2019 ASI 052 02/03/2020 bonniem