HomeMy WebLinkAboutFile Documents.534 E Cooper Ave.0003.2017 (29).ACBKWINDOW, SEE ARCHITECTURAL SET WINDOW ON BEAD OF DOW 758 ALONG BACK OF SILL 1" TALL x 1-1/2" LONG ALUMINUM BACK DAM, FULL WIDTH OF AND FASTENED TO ROUGH OPENING EXTEND SELF-ADHERING FLASHING INTO ROUGH OPENING AND ONTO ALUMINUM BACK DAM. FLASHING TO OVERLAP WRB 3" MIN.3" MINRIGID INSULATION, SEE SPECIFICATIONS DRAINAGE MEDIA, SEE SPECIFICATIONS EXTERIOR CLADDING, SEE ARCHITECTURAL PERIMETER SEALANT JOINT, SEE ARCHITECTURAL. SEALANT SHALL NOT BLOCK WINDOW WEEP SYSTEM. WRB ( ) FLASHING, WHERE PRESENT, SEE ARCH INTERIOR FINISH, SEE ARCHITECTURAL SEALANT AND BACKER ROD BETWEEN WINDOW FRAME AND SELF-ADHERING FLASHING WITHIN ROUGH OPENING FILL ANNULAR SPACE BETWEEN WINDOW FRAME AND ROUGH OPENING WITH LOW-EXPANSION SPRAY POLYURETHANE FOAM SELF-ADHERING FLASHING TO WRAP OVER WRB 3" MIN AND INTO ROUGH OPENING WINDOW, SEE ARCHITECTURAL3" MIN RIGID INSULATION AND DRAINAGE MEDIA, SEE SPECIFICATIONS PERIMETER SEALANT, SEE ARCHITECTURAL EXTERIOR CLADDING, SEE ARCHITECTURAL SELF-ADHERING FLASHING TO WRAP INTO ROUGH OPENING RIGID INSULATION, SEE SPECIFICATIONS DRAINAGE MEDIA, SEE SPECIFICATIONS EXTERIOR CLADDING, SEE ARCHITECTURAL WRB TO OVERLAP SELF-ADHERING FLASHING AND SHEET METAL HEAD FLASHING FILL ANNULAR SPACE BETWEEN WINDOW FRAME AND ROUGH OPENING WITH LOW-EXPANSION SPRAY POLYURETHANE FOAM WINDOW, SEE ARCHITECTURAL2" MININSTALL CONTINUOUS BEAD OF SEALANT ALONG EXTERIOR EDGE BELOW DRIP FLASHING SELF-ADHERING THROUGH-WALL FLASHING TO ADHERE TO ROUGH OPENING MEMBRANE FLASHING AND OUT ONTO SHEET METAL DRIP EDGE2" MINSEALANT JOINT, SEE ARCHITECTURAL SEPARATOR BETWEEN SHEET METAL DRIP FLASHING AND STEEL ANGLE, SEE SPECIFICATIONS MASONRY WEEP, SEE SPECIFICATIONS SHEET METAL DRIP WITH HEMMED DRIP LEG INTERIOR SEALANT JOINT INSTALL FILLET OF COMPATIBLE LIQUID MEMBRANE AT INSIDE CORNER DECORATIVE STEEL ELEMENTS, SEE ARCHITECTURAL SEPARATOR BETWEEN SHEET METAL DRIP FLASHING AND STEEL PLATE, SEE SPECIFICATIONS MASONRY, SEE ARCHITECTURAL RIGID INSULATION, SEE SPECIFICATIONS DRAINAGE MEDIA, SEE SPECIFICATIONS WRB TO OVERLAP SELF-ADHERING FLASHING 4" MIN SHEET METAL DRIP WITH HEMMED DRIP LEG4" MINSELF-ADHERING FLASHING TO EXTEND UP WALL 4" MIN BEYOND STEEL PLATE, AND ONTO SHEET METAL DRIP 3" MIN. PRIME ALL SURFACES PRIOR TO INSTALLATION. MASONRY WEEP, SEE SPECIFICATIONS INSTALL CONTINUOUS BEAD OF SEALANT ALONG EXTERIOR EDGE BELOW DRIP FLASHING 3" MIN INSTALL FILLET OF COMPATIBLE LIQUID MEMBRANE AT INSIDE CORNER GUSSET PLATE BEYOND, SEE STRUCTURAL EXTEND SELF-ADHERING FLASHING ONTO BACK DAM AT SILL AND UP JAMBS 4" MINIMUM ALUMINUM BACK DAM DOW 758 SEALANT AT INTERSECTION OF BACK DAM AND WINDOW JAMB SELF-ADHERING FLASHING TO WRAP OVER WRB AND INTO ROUGH OPENING AT JAMBS SET WINDOW ON BED OF CONTINUOUS SEALANT ALONG BACK OF SILL SHEET METAL FLASHINGS AT SILL AND JAMBS PERIMETER SEALANT, SEE ARCHITECTURAL CLOSURE FLASHING ALONG JAMBS, IF NECESSARY. SEE JAMB DETAILS SEALANT JOINT, SEE ARCHITECTURAL SEPARATOR BETWEEN SHEET METAL DRIP FLASHING AND STEEL ANGLE, SEE SPECIFICATIONS FILL ANNULAR SPACE BETWEEN WINDOW FRAME AND ROUGH OPENING WITH LOW-EXPANSION SPRAY POLYURETHANE FOAM MASONRY, SEE ARCHITECTURAL DRAINAGE MEDIA, SEE SPECIFICATIONS RIGID INSULATION, SEE SPECIFICATIONS CUT WRB AND INSTALL OVER MEMBRANE FLASHING SELF-ADHERING FLASHING TO EXTEND UP WALL 6" MIN AND ONTO SHEET METAL DRIP 3" MIN. PRIME ALL SURFACES PRIOR TO INSTALLATION. MASONRY WEEP, SEE SPECIFICATIONS SHEET METAL DRIP WITH HEMMED DRIP LEG INSTALL CONTINUOUS BEAD OF SEALANT ALONG EXTERIOR EDGE BELOW DRIP FLASHING6" MININTERIOR SEALANT JOINT WINDOW, SEE ARCHITECTURAL NOTE: IF SELF-ADHERING WRB CANNOT BE REMOVED FROM SHEATHING WITHOUT DAMAGE, CONTACT WJE FOR REVISED DETAIL. PROVIDE THREE (E) TRANSVERSE ROWS OF SEALANT AT LAP FLAS H I N G SECT I O N 4" CUT AWAY 4" OF HEMMED EDGE AT END OF DRIP EDGE SECTION FLAS H I N G SECT I O N OPEN HEMMED EDGE SLIGHTLY TO RECEIVE OPEN EDGE OF DRIP SECURE BACK LEG OF THROUGH-WALL FLASHING TO BACKUP PER SPECIFICATIONS INSTALL SELF-ADHESIVE FLASHING AND ALLOW WATER-RESISTIVE BARRIER TO LAP OVER (NOT SHOWN FOR CLARITY) INSTALL SELF-ADHESIVE FLASHING MANUFACTURER'S LIQUID MEMBRANE AT LAPS AND AT LEADING EDGE OF SPLICES IN METAL FLASHING 4" 1" TALL x 1-1/2" LONG ALUMINUM BACK DAM, FULL WIDTH OF AND FASTENED TO ROUGH OPENING EXTERIOR METAL CLADDING, SEE ARCHITECTURAL3" MINWINDOW, SEE ARCHITECTURAL SET WINDOW ON BEAD OF DOW 758 ALONG BACK OF SILL EXTEND SELF-ADHERING FLASHING INTO ROUGH OPENING AND ONTO ALUMINUM BACK DAM. FLASHING TO OVERLAP WRB 3" MIN. RIGID INSULATION, SEE SPECIFICATIONS PERIMETER SEALANT JOINT, SEE ARCHITECTURAL WRB ( ) SEALANT BEAD BETWEEN STEEL FACADE ELEMENT AND DRIP EDGE SEPARATOR SHEET, SEE SPECIFICATIONS CANT OF COMPATIBLE LIQUID MEMBRANE STEEL FACADE ELEMENTS, SEE ARCHITECTURAL FILLET BEAD OF COMPATIBLE LIQUID MEMBRANE AT PERIMETER OF GUSSET PLATE GUSSET PLATE, SEE STRUCTURAL NOTE: CAVITY INSULATION, DRAINAGE MEDIA, AND CLADDING NOT SHOWN FOR CLARITY FIRST SHEET OF SELF-ADHERING FLASHING TO BE CONTINUOUS OVER FACE OF GUSSET PLATE FILLET BEAD OF COMPATIBLE LIQUID MEMBRANE AT PERIMETER OF SELF-ADHERED FLASHING AIR BARRIER TO OVERLAP THROUGH-WALL FLASHING SECOND SHEET OF SELF-ADHERING FLASHING TO BE DISCONTINUOUS AT GUSSET PLATE. FLASHING TO EXTEND UP WALL 4" MIN BEYOND STEEL PLATE AND ONTO SHEET METAL DRIP FLASHING NOTE: CAVITY INSULATION, DRAINAGE MEDIA, AND CLADDING NOT SHOWN FOR CLARITY 534 EAST COOPER ASPEN, CO 21512.00 WJE No. 2016.3375 Headquarters & Laboratories: Northbrook, Illinois Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York Princeton | San Francisco | Seattle | Washington, D.C. Wiss, Janney, Elstner Associates, Inc. 3609 South Wadsworth Boulevard, Suite 400 Lakewood, Colorado 80235 303.914.4300 tel | 303.914.3000 fax www.wje.com ENGINEERS ARCHITECTS MATERIALS SCIENTISTS 2019.05.21 Issued for Construction 2 Scale: 6" = 1'-0" WINDOW SILL FLASHING DETAIL @ ROSESTONE CLADDING WP200 WATER-RESISTIVE BARRIER DETAILS As Shown 3 Scale: 6" = 1'-0" WINDOW JAMB FLASHING DETAIL @ ROSESTONE CLADDING 4 Scale: 6" = 1'-0" WINDOW HEAD FLASHING DETAIL @ ROSESTONE CLADDING 9 Not to Scale WINDOW SILL FLASHING ISOMETRIC 6 Not to Scale MASONRY FLASHING ISOMETRIC - STEP 1 10 Not to Scale MASONRY FLASHING SPLICE DETAIL WINDOW SILL FLASHING DETAIL 7 Not to Scale MASONRY FLASHING ISOMETRIC - STEP 2