HomeMy WebLinkAboutFile Documents.534 E Cooper Ave.0003.2017 (29).ACBKWINDOW, SEE ARCHITECTURAL
SET WINDOW ON BEAD OF DOW 758 ALONG
BACK OF SILL
1" TALL x 1-1/2" LONG ALUMINUM BACK DAM,
FULL WIDTH OF AND FASTENED TO ROUGH
OPENING
EXTEND SELF-ADHERING FLASHING INTO
ROUGH OPENING AND ONTO ALUMINUM
BACK DAM. FLASHING TO OVERLAP WRB 3"
MIN.3" MINRIGID INSULATION, SEE SPECIFICATIONS
DRAINAGE MEDIA, SEE SPECIFICATIONS
EXTERIOR CLADDING, SEE ARCHITECTURAL
PERIMETER SEALANT JOINT, SEE
ARCHITECTURAL. SEALANT SHALL NOT
BLOCK WINDOW WEEP SYSTEM.
WRB ( )
FLASHING, WHERE PRESENT, SEE ARCH
INTERIOR FINISH, SEE ARCHITECTURAL
SEALANT AND BACKER ROD BETWEEN
WINDOW FRAME AND SELF-ADHERING
FLASHING WITHIN ROUGH OPENING
FILL ANNULAR SPACE BETWEEN WINDOW
FRAME AND ROUGH OPENING WITH
LOW-EXPANSION SPRAY POLYURETHANE
FOAM
SELF-ADHERING FLASHING TO WRAP OVER
WRB 3" MIN AND INTO ROUGH OPENING
WINDOW, SEE ARCHITECTURAL3" MIN
RIGID INSULATION AND DRAINAGE MEDIA,
SEE SPECIFICATIONS
PERIMETER SEALANT, SEE ARCHITECTURAL
EXTERIOR CLADDING, SEE ARCHITECTURAL
SELF-ADHERING FLASHING TO WRAP INTO
ROUGH OPENING
RIGID INSULATION, SEE SPECIFICATIONS
DRAINAGE MEDIA, SEE SPECIFICATIONS
EXTERIOR CLADDING, SEE ARCHITECTURAL
WRB TO OVERLAP SELF-ADHERING
FLASHING AND SHEET METAL HEAD
FLASHING
FILL ANNULAR SPACE BETWEEN WINDOW FRAME
AND ROUGH OPENING WITH LOW-EXPANSION
SPRAY POLYURETHANE FOAM
WINDOW, SEE ARCHITECTURAL2" MININSTALL CONTINUOUS BEAD OF SEALANT
ALONG EXTERIOR EDGE BELOW DRIP
FLASHING
SELF-ADHERING THROUGH-WALL FLASHING
TO ADHERE TO ROUGH OPENING MEMBRANE
FLASHING AND OUT ONTO SHEET METAL
DRIP EDGE2" MINSEALANT JOINT, SEE ARCHITECTURAL
SEPARATOR BETWEEN SHEET METAL DRIP
FLASHING AND STEEL ANGLE, SEE SPECIFICATIONS
MASONRY WEEP, SEE SPECIFICATIONS
SHEET METAL DRIP WITH HEMMED
DRIP LEG
INTERIOR SEALANT JOINT
INSTALL FILLET OF COMPATIBLE LIQUID
MEMBRANE AT INSIDE CORNER
DECORATIVE STEEL ELEMENTS, SEE
ARCHITECTURAL
SEPARATOR BETWEEN SHEET METAL DRIP
FLASHING AND STEEL PLATE, SEE
SPECIFICATIONS
MASONRY, SEE ARCHITECTURAL
RIGID INSULATION, SEE
SPECIFICATIONS
DRAINAGE MEDIA, SEE
SPECIFICATIONS
WRB TO OVERLAP SELF-ADHERING
FLASHING 4" MIN
SHEET METAL DRIP WITH HEMMED
DRIP LEG4" MINSELF-ADHERING FLASHING TO
EXTEND UP WALL 4" MIN BEYOND
STEEL PLATE, AND ONTO SHEET
METAL DRIP 3" MIN. PRIME ALL
SURFACES PRIOR TO INSTALLATION.
MASONRY WEEP, SEE SPECIFICATIONS
INSTALL CONTINUOUS BEAD
OF SEALANT ALONG
EXTERIOR EDGE BELOW DRIP
FLASHING
3" MIN
INSTALL FILLET OF COMPATIBLE
LIQUID MEMBRANE AT INSIDE
CORNER
GUSSET PLATE BEYOND, SEE
STRUCTURAL
EXTEND SELF-ADHERING FLASHING ONTO
BACK DAM AT SILL AND UP JAMBS 4" MINIMUM
ALUMINUM BACK DAM
DOW 758 SEALANT AT INTERSECTION
OF BACK DAM AND WINDOW JAMB
SELF-ADHERING FLASHING TO
WRAP OVER WRB AND INTO
ROUGH OPENING AT JAMBS
SET WINDOW ON BED OF CONTINUOUS
SEALANT ALONG BACK OF SILL
SHEET METAL FLASHINGS AT SILL AND JAMBS
PERIMETER SEALANT, SEE ARCHITECTURAL
CLOSURE FLASHING ALONG
JAMBS, IF NECESSARY. SEE
JAMB DETAILS
SEALANT JOINT, SEE ARCHITECTURAL
SEPARATOR BETWEEN SHEET METAL DRIP
FLASHING AND STEEL ANGLE, SEE SPECIFICATIONS
FILL ANNULAR SPACE BETWEEN WINDOW FRAME
AND ROUGH OPENING WITH LOW-EXPANSION
SPRAY POLYURETHANE FOAM
MASONRY, SEE ARCHITECTURAL
DRAINAGE MEDIA, SEE SPECIFICATIONS
RIGID INSULATION, SEE
SPECIFICATIONS
CUT WRB AND INSTALL OVER
MEMBRANE FLASHING
SELF-ADHERING FLASHING TO
EXTEND UP WALL 6" MIN AND ONTO
SHEET METAL DRIP 3" MIN. PRIME
ALL SURFACES PRIOR TO
INSTALLATION.
MASONRY WEEP, SEE SPECIFICATIONS
SHEET METAL DRIP WITH HEMMED
DRIP LEG
INSTALL CONTINUOUS BEAD OF
SEALANT ALONG EXTERIOR EDGE
BELOW DRIP FLASHING6" MININTERIOR SEALANT JOINT
WINDOW, SEE ARCHITECTURAL
NOTE:
IF SELF-ADHERING WRB CANNOT BE
REMOVED FROM SHEATHING
WITHOUT DAMAGE, CONTACT WJE
FOR REVISED DETAIL.
PROVIDE THREE (E) TRANSVERSE
ROWS OF SEALANT AT LAP
FLAS
H
I
N
G
SECT
I
O
N
4"
CUT AWAY 4" OF HEMMED EDGE
AT END OF DRIP EDGE SECTION
FLAS
H
I
N
G
SECT
I
O
N
OPEN HEMMED EDGE SLIGHTLY
TO RECEIVE OPEN EDGE OF DRIP
SECURE BACK LEG OF
THROUGH-WALL FLASHING TO
BACKUP PER SPECIFICATIONS
INSTALL SELF-ADHESIVE
FLASHING AND ALLOW
WATER-RESISTIVE BARRIER TO
LAP OVER (NOT SHOWN FOR
CLARITY)
INSTALL SELF-ADHESIVE FLASHING
MANUFACTURER'S LIQUID MEMBRANE AT
LAPS AND AT LEADING EDGE OF SPLICES
IN METAL FLASHING
4"
1" TALL x 1-1/2" LONG ALUMINUM BACK DAM,
FULL WIDTH OF AND FASTENED TO ROUGH
OPENING
EXTERIOR METAL CLADDING, SEE
ARCHITECTURAL3" MINWINDOW, SEE ARCHITECTURAL
SET WINDOW ON BEAD OF DOW 758 ALONG
BACK OF SILL
EXTEND SELF-ADHERING FLASHING INTO
ROUGH OPENING AND ONTO ALUMINUM
BACK DAM. FLASHING TO OVERLAP WRB 3"
MIN.
RIGID INSULATION, SEE SPECIFICATIONS
PERIMETER SEALANT JOINT, SEE
ARCHITECTURAL
WRB ( )
SEALANT BEAD BETWEEN STEEL FACADE
ELEMENT AND DRIP EDGE
SEPARATOR SHEET, SEE SPECIFICATIONS
CANT OF COMPATIBLE LIQUID MEMBRANE
STEEL FACADE ELEMENTS, SEE ARCHITECTURAL
FILLET BEAD OF COMPATIBLE LIQUID
MEMBRANE AT PERIMETER OF GUSSET
PLATE
GUSSET PLATE, SEE STRUCTURAL
NOTE:
CAVITY INSULATION, DRAINAGE
MEDIA, AND CLADDING NOT SHOWN
FOR CLARITY
FIRST SHEET OF SELF-ADHERING
FLASHING TO BE CONTINUOUS
OVER FACE OF GUSSET PLATE
FILLET BEAD OF COMPATIBLE LIQUID
MEMBRANE AT PERIMETER OF
SELF-ADHERED FLASHING
AIR BARRIER TO OVERLAP
THROUGH-WALL FLASHING
SECOND SHEET OF SELF-ADHERING
FLASHING TO BE DISCONTINUOUS
AT GUSSET PLATE. FLASHING TO
EXTEND UP WALL 4" MIN BEYOND
STEEL PLATE AND ONTO SHEET
METAL DRIP FLASHING
NOTE:
CAVITY INSULATION, DRAINAGE
MEDIA, AND CLADDING NOT SHOWN
FOR CLARITY
534 EAST COOPER
ASPEN, CO
21512.00
WJE No. 2016.3375
Headquarters & Laboratories: Northbrook, Illinois
Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit
Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
3609 South Wadsworth Boulevard, Suite 400
Lakewood, Colorado 80235
303.914.4300 tel | 303.914.3000 fax
www.wje.com
ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS
2019.05.21 Issued for
Construction
2 Scale: 6" = 1'-0"
WINDOW SILL FLASHING DETAIL
@ ROSESTONE CLADDING
WP200
WATER-RESISTIVE
BARRIER DETAILS
As Shown
3 Scale: 6" = 1'-0"
WINDOW JAMB FLASHING DETAIL
@ ROSESTONE CLADDING
4 Scale: 6" = 1'-0"
WINDOW HEAD FLASHING DETAIL
@ ROSESTONE CLADDING
9 Not to Scale
WINDOW SILL FLASHING ISOMETRIC
6 Not to Scale
MASONRY FLASHING ISOMETRIC - STEP 1
10 Not to Scale
MASONRY FLASHING SPLICE DETAIL
WINDOW SILL FLASHING DETAIL
7 Not to Scale
MASONRY FLASHING ISOMETRIC - STEP 2