HomeMy WebLinkAboutFile Documents.533 E Main St.0100.2018 (4).ACBK
610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com
27 November 2018
ST. MARY CATHOLIC CHURCH
CHANGE ORDER PERMIT RESPONSES - ZONING
1. There are no additional exterior lights proposed
2. See attached plan and elevation of proposed condenser screening with
accompanying details.
03/16/2019
0100.2018.ACBK
Page: [4] 2018-06-19 St Mary CD Sheet Set-MATERIALS
PLAN
Checkmark: Unchecked
Author: jeffreyb
File Name: 2018-09-10 St Mary CD Sheet Set CO mark up
(1).pdf
Is there any exterior lights being proposed that
were not shown in the original plans?
For the mechanical screen please provide
elevation showing height as well as materials.
2018-09-10 St Mary CD Sheet Set CO mark up (1).pdf (1)
Is there any exterior lights being proposed that were not
shown in the original plans?
For the mechanical screen please provide elevation
showing height as well as materials.
03/16/2019
EXISTING PADPOSTS AND SCREENFROM GREENSCREENHEIGHT OFCONDENSERSST. MARY CONDENSER SCREENINGPLANELEVATION(4) EXISTINGCONDENSERSMAINTENANCEGAP03/16/201903/28/2019
Freestanding, Horizontal FENCE / SCREENFALL 20151743 S. La Cienega Blvd. Los Angeles CA 90035 T - 800.450.3494 www.greenscreen.com
CLCL
FREESTANDING HORIZONTAL — FENCE / SCREEN
PLAN
ELEVATION
CLCL
3” THICK greenscreen®
PANEL, TYP.
3” ROUND OR SQUARE
STEEL POST W/POST CAP,
TYP.
#5104 CHANNEL TRIM OR
#5105 STEEL EDGE TRIM,
RECOMMENDED AT TOP
EDGE OF PANEL, TYP.
#5133X SNAP CLIPS W/
STAINLESS STEEL SCREW,
TYP.
PANEL TRIM OPTIONAL
WITH #5133X
OPTIONAL: 5141 “C” CLIP
W/ #5105 EDGE TRIM
REQUIRED @ VERTICAL EDGES
USE #5142 + #5136.25
SPACER
FLEX “C” RINGS @ PANEL
TO PANEL SEAM @ 12” O.C.
OPTIONAL
3” THICK greenscreen®
PANEL, TYP.
#5105 STEEL EDGE TRIM
RECOMMENDED @
BOTTOM EDGE OF PANEL
FINISH GRADE
POST TO POST CENTERS = PANEL LENGTH + 4”, TYP.
HORIZONTAL PANEL MAXIMUM 96” IN 2’ INCREMENTS
POST TO POST CLEAR = PANEL LENGTH + 1”, TYP.VERIFY HEIGHT - PANELS SIZED IN 2” INCREMENTS48” MAXIMUM48” MAXIMUMPANEL HEIGHTPANEL HEIGHTVERIFY+ 6”-VERIFYPOST IMBED LENGTH &
FOOTING SIZE SHOULD BE
VERIFIED BASED ON OVER-
ALL HEIGHT, WINDLOADS &
SOIL CONDITIONS.
NOTE: VERIFY PANEL SPAN
AND CLIP SPACING FOR ALL
ROOFTOP INSTALLATIONS
AND ALL INSTALLATIONS
20’ ABOVE GRADE.
NOTE: SPECIFIC
ENGINEERING MAY BE
REQUIRED BASED ON SITE
SPECIFIC SOIL CONDITIONS,
LOCAL WIND LOADS, AND
VERTICAL HEIGHT OF
FENCE/SCREEN.
greenscreen®03/16/2019
greenscreen®1743 S. La Cienega Blvd. Los Angeles CA 90035 T - 800.450.3494 www.greenscreen.com5133X Snap Clip, Post Mounted MOUNTING CLIPFALL 2015*Only requires access to one face of panel
*Consult Mounting Options/ Freestanding Horizontal for maximum spans.
NOTE: Mounting hole in clip is sized for 1/4” diameter fastener.
#5133X SNAP CLIP - POST MOUNTED
3” ROUND OR SQUARE STEEL POST
3” ROUND OR SQUARE STEEL POST
#5133X SNAP CLIP -
HOOK CLIP ON PANEL WIRE +
ROTATE UNTIL IT “SNAPS” INTO POSITION
3” THICK greenscreen®
PANEL, TYP.
+1/2”-1-3/4”5”
STAINLESS STEEL SELF-TAPPING
TEK SCREWS (2) PER CLIP
CLIP SIZED FOR 1/4” DIA. FASTENER,
TYP.
#5133X SNAP CLIP
#5137 ROUND / #5139 SQUARE POST
CAP/ WELDED FLAT CAP
STAINLESS STEEL SELF-TAPPING
TEK SCREWS (2)
CLIP SIZED FOR 1/4” DIA. FASTENER,
TYP.
ADDITIONAL PANEL WHERE OCCURS,
TYP.
ELEVATION
PLAN / SECTION
#5104 CHANNEL TRIM
OR #5105 EDGE TRIM
OPTIONAL @ TOP EDGE
AND SIDES OF PANEL
5104 OR 5105 EDGE TRIM OPTIONAL
5104 OR 5105 EDGE TRIM
OPTIONAL
CL
03/16/2019