HomeMy WebLinkAboutFile Documents.533 E Main St.0100.2018 (4).ACBK 610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com 27 November 2018 ST. MARY CATHOLIC CHURCH CHANGE ORDER PERMIT RESPONSES - ZONING 1. There are no additional exterior lights proposed 2. See attached plan and elevation of proposed condenser screening with accompanying details. 03/16/2019 0100.2018.ACBK Page: [4] 2018-06-19 St Mary CD Sheet Set-MATERIALS PLAN Checkmark: Unchecked Author: jeffreyb File Name: 2018-09-10 St Mary CD Sheet Set CO mark up (1).pdf Is there any exterior lights being proposed that were not shown in the original plans? For the mechanical screen please provide elevation showing height as well as materials. 2018-09-10 St Mary CD Sheet Set CO mark up (1).pdf (1) Is there any exterior lights being proposed that were not shown in the original plans? For the mechanical screen please provide elevation showing height as well as materials. 03/16/2019 EXISTING PADPOSTS AND SCREENFROM GREENSCREENHEIGHT OFCONDENSERSST. MARY CONDENSER SCREENINGPLANELEVATION(4) EXISTINGCONDENSERSMAINTENANCEGAP03/16/201903/28/2019 Freestanding, Horizontal FENCE / SCREENFALL 20151743 S. La Cienega Blvd. Los Angeles CA 90035 T - 800.450.3494 www.greenscreen.com CLCL FREESTANDING HORIZONTAL — FENCE / SCREEN PLAN ELEVATION CLCL 3” THICK greenscreen® PANEL, TYP. 3” ROUND OR SQUARE STEEL POST W/POST CAP, TYP. #5104 CHANNEL TRIM OR #5105 STEEL EDGE TRIM, RECOMMENDED AT TOP EDGE OF PANEL, TYP. #5133X SNAP CLIPS W/ STAINLESS STEEL SCREW, TYP. PANEL TRIM OPTIONAL WITH #5133X OPTIONAL: 5141 “C” CLIP W/ #5105 EDGE TRIM REQUIRED @ VERTICAL EDGES USE #5142 + #5136.25 SPACER FLEX “C” RINGS @ PANEL TO PANEL SEAM @ 12” O.C. OPTIONAL 3” THICK greenscreen® PANEL, TYP. #5105 STEEL EDGE TRIM RECOMMENDED @ BOTTOM EDGE OF PANEL FINISH GRADE POST TO POST CENTERS = PANEL LENGTH + 4”, TYP. HORIZONTAL PANEL MAXIMUM 96” IN 2’ INCREMENTS POST TO POST CLEAR = PANEL LENGTH + 1”, TYP.VERIFY HEIGHT - PANELS SIZED IN 2” INCREMENTS48” MAXIMUM48” MAXIMUMPANEL HEIGHTPANEL HEIGHTVERIFY+ 6”-VERIFYPOST IMBED LENGTH & FOOTING SIZE SHOULD BE VERIFIED BASED ON OVER- ALL HEIGHT, WINDLOADS & SOIL CONDITIONS. NOTE: VERIFY PANEL SPAN AND CLIP SPACING FOR ALL ROOFTOP INSTALLATIONS AND ALL INSTALLATIONS 20’ ABOVE GRADE. NOTE: SPECIFIC ENGINEERING MAY BE REQUIRED BASED ON SITE SPECIFIC SOIL CONDITIONS, LOCAL WIND LOADS, AND VERTICAL HEIGHT OF FENCE/SCREEN. greenscreen®03/16/2019 greenscreen®1743 S. La Cienega Blvd. Los Angeles CA 90035 T - 800.450.3494 www.greenscreen.com5133X Snap Clip, Post Mounted MOUNTING CLIPFALL 2015*Only requires access to one face of panel *Consult Mounting Options/ Freestanding Horizontal for maximum spans. NOTE: Mounting hole in clip is sized for 1/4” diameter fastener. #5133X SNAP CLIP - POST MOUNTED 3” ROUND OR SQUARE STEEL POST 3” ROUND OR SQUARE STEEL POST #5133X SNAP CLIP - HOOK CLIP ON PANEL WIRE + ROTATE UNTIL IT “SNAPS” INTO POSITION 3” THICK greenscreen® PANEL, TYP. +1/2”-1-3/4”5” STAINLESS STEEL SELF-TAPPING TEK SCREWS (2) PER CLIP CLIP SIZED FOR 1/4” DIA. FASTENER, TYP. #5133X SNAP CLIP #5137 ROUND / #5139 SQUARE POST CAP/ WELDED FLAT CAP STAINLESS STEEL SELF-TAPPING TEK SCREWS (2) CLIP SIZED FOR 1/4” DIA. FASTENER, TYP. ADDITIONAL PANEL WHERE OCCURS, TYP. ELEVATION PLAN / SECTION #5104 CHANNEL TRIM OR #5105 EDGE TRIM OPTIONAL @ TOP EDGE AND SIDES OF PANEL 5104 OR 5105 EDGE TRIM OPTIONAL 5104 OR 5105 EDGE TRIM OPTIONAL CL 03/16/2019