HomeMy WebLinkAboutFile Documents.533 E Main St.0004.2017.ACBK 610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com ST. MARY CATHOLIC CHURCH PERMIT COMMENT RESPONSES - BUILDING 1. See attached letter requesting exemption 2. See attached Civil Drawings from SGM 3. See attached drawing of trash enclosure 4. See attached crawlspace access diagram from Structural Associates 5. Sheet A2.5 & A8.3  Complies with side approach ANSI figure 308.3.2 (b). Also see interior elevation 1/A8.3 6. Sheet A2.5  See sheet A2.4 – wall construction to comply with UL U309 assembly. 7. The window in question is no longer in the project scope 8. Countertop height complies with code  See Sheet A8.3 9. A custom ramp is planned for this space and will be stored in the vesting sacristy; see attached cutsheet of proposed portable ramp 10. Sheet A2.6  Sink has been relocated per attached drawing 11. Per discussions and additional mechanical drawings attached, no shafts penetrate the floor of the nave in the proposed design 12. Confessional design under review – not under the purview of the ADA; if possible in the historic structure, all possible allowances made of accessible access. See attached letter 13. Sheet A2.6  Wheelchair locations have been accommodated per revised sheet. 14. Handrails will be provided as part of the altar rail design with is on-going; handrails are not required for this project. 15. Sheet A 2.7  Door width revised to 3’-0” wide 16. Sheet A 4.1  Projector has been eliminated from scope of work City of Aspen Received 5/2/17 Building Department 610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com 17. Sheet A4.1 & A7.10  Insulation to be a combination of R-38 batt insulation over ~4” closed cell sprayed-on insulation (R-28). Refer to details 1, 2, 5, & 6/A7.10  An attic ventilation fan has been added as required. Re: sheet M2.6. 18. Sheet A4.1  Permanent raised platform is not to be used for storage and therefore not required to be rated construction. 19. Sheet A4.2  Dimensions have been provided on revised sheet A4.2 20. Sheet A4.2  Light fixtures and penetrations to be protected and ceiling to rated similar to UL U309 with 2 layers of gypsum board at ceiling. 21. Sheet A2.6  See revised drawing 22. Sheet A6.1  See revised drawing. 23. Sheet A6.1  See revised drawing. 24. Sheet A6.1  See revised drawing. 25. Sheet A6.1  See revised drawing. 26. Sheet A6.1  See revised drawing. Per electrical drawings, outlets are shown on side walls. 27. Sheet A6.1  See elevations 6 & 8 on sheet A6.1 28. Sheet A7.10  See revised drawing. 29. Sheet A6.1  GC option to provide sprinkler heads or non-combustible insulation in concealed spaces. 30. Sheet A2.6 & A8.4  See revised drawing. 31. General notes and structural design load specifications can be found on Sheet S0.1. Additional specifications can be found in the book specifications that have been assembled for this project. 32. Requirements for continuous –vs- periodic inspections are indicated in the text City of Aspen Received 5/2/17 Building Department 610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com descriptions of the Special Inspections table on sheet S0.0. 33. See comment 18 above 34. See attached signed inspection agreement 35. The church employs a full-time maintenance professional who is responsible to clear snow from the intake wells. Also, there is an existing intake well that has no issue with remaining clear of snow; the tremendous snowfalls land typically and approximately 7’ away from the face of the church. 36. Minimum headroom below ductwork in basement occupied spaces is 7 ft. 37. Revised drawings show additional exit from boiler room as required. 38. All spaces are provided with natural ventilation meeting IMC requirements, and do not require mechanical ventilation. Areas not naturally ventilated are restroom groups, which are provided with mechanical exhaust at code-required rates. Exhaust fan schedule has been updated to include notes indicating code-required rates. 39. Refer to General Note #20, sheet M0.0, for thermostat mounting height requirement. 40. AHU access hatch requirement has been noted on revised plans. Refer to revised architectural drawings for hatch design details. 41. Specification section 233113 Metal Ducts has been updated to reflect requirements. 42. AHU access hatch requirement has been noted on revised plans. Refer to revised architectural drawings for hatch design details. 43. Snowmelt insulation requirement has been noted in mechanical diagrams, and detailed in civil pavement diagrams. 44. Sacristy sink shall be re-connected to existing sacristy sink discharge line, which routes to the crawlspace. Expected daily fluid amount is approximately ¼ cup of fluid. The Scrarium drains into the earth itself beneath the church and is not seen on the civil drawings. 45. All lighting in the lower level is existing to remain. The main level lighting plan is in the drawing set 46. Occupancy sensors are being provided to turn off lighting when no occupants are present. City of Aspen Received 5/2/17 Building Department 610 East Hyman Avenue ▪ Aspen, Colorado 81611 ▪ 970.925.5590 ▪ Fax 970.920.4557 ▪ www.cunniffe.com 47. The exit signs at the ends of the corridor have integral frog eyes. We are also providing an additional egress fixture (X2) in the middle of the corridor. 48. All exterior lighting has been removed from scope of work. Interior lighting cutsheets related to the main level will be provided in addition to the main level lighting COMcheck. See attached letter requesting exemption for Sanctuary-level COMcheck 49. All controls and receptacles that must meet ADA requirements shall be mounted within 44” above finish floor. 50. The assisted listening system is shown on the functional diagram on sheet T3.0. Attachments:  Numbered building department comments  Letter requesting exemption  Portable ramp cut sheet  Special Inspections Agreement  IBC form  REMP worksheet  Separate files: o Crawlspace diagram o Architectural Drawings o Mechanical Drawings o Civil Drawings o Trash Enclosure drawings City of Aspen Received 5/2/17 Building Department 0004-2017-ACBK_BuildingComments_1 Page: 9 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 9 The two stairways from the sanctuary level are open to each other and come together on the main level, providing only a single exit from the sanctuary level. You exceed the common path travel distance (132' vs 75' allowed). Draft a letter to the building official requesting exemption from the required two exits, separation of exits, and common path travel distance per 2009 3409. 00.Plans.Combined.pdf (50) Page: 19 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 20 If insulation is perforated, you must increase the thickness to achieve an area weighted average of R-10 minimum. Typically this requires 3" of R5/inch rigid insulation. Page: 24 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 25 If wall surrounding transformer is modified, contact City of Aspen Electric. Page: 4 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 37 You are performing structural and mechanical improvements to the crawlspaces. Provide access to crawlspaces per 2009 IBC 1209.1. Page: 5 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 38 The new coffee counter/kitchenette must be accessible (2009 IBC 1109.4). Provide a detailed plan and elevations with clearances and dimensions shown. OCCUPANCY CALCULATIONS (IBC 2009) ROOM / AREA OCC. LOAD OCC LOAD EXISTS REQ'D PROVIDED MAIN LEVELMEETING ROOM 1,654 SF / 15 SF EA: 110 2 2OFFICE AREA 962 SF / 100 SF EA: 10 1 1KITCHEN451 SF / 200 SF EA: 3 1 2123 SANCTUARY LEVELNARTHEX 187 SF / 7 SF EA: 13 2 2NAVE 18" PER OCC 354 2 2SACRISTIES 222 SF / 100 SF EA: 0 1 1CHOIR LOFT 129 SF/ 7 SF EA 18 1 1SANCTUARY495 SF / 100 SF EA: 4 1 1TOTAL 389 TRAVEL DISTANCES REQUIRED MAX. DISTANCEEXIT ACCESS TRAVEL DISTANCEL (1028.7) MAX. 250' W/ SPRINKLERS 132' FROM SACRISTY AT 2ND LEVEL TO EXIT AT MAIN ENTRANCECOMMON PATH OF TRAVEL MAX 75' SEPARATION OF EXITS (IBC SECTION 1015.2.2)PER IBC 3409 HISTORIC BUILDINGS ARE EXEMPT FROM THIS REQUIREMENT. IN ADDITION, PROJECT ALTERATIONS TOEXISTING STRUCTURE DECREASES THE OCCUPANT LOAD OF THE NAVE BY HAVING THE NEW CHOIR LOFT OCCUPANTSEXIT DIRECTLY INTO THE EXISTING STAIR AND THEREFORE ARE NOT INCLUDED IN THE NAVE OCCUPANT LOAD. FIRE PROTECTION (IBC 903.2.1 AND 903.2.1.3)BUILDING IS CURRENTLY PROTECTED WITH FIRE SPRINKLER SYSTEM. EXISTING SYSTEM TO BE EXTENDED FOR NEWPARTITIONS AND CEILING CONFIGURATION ON BOTH FLOOR LEVELS. PLUMBING FIXTURE COUNTSAREA WATER CLOSETS REQ'D.PROVIDEDSANCTUARY LEVEL (PRIMARY OCCUPANCY)390 TOTAL OCCUPANTS = 195M + 195W 2 M 3 W 3 M 3 W A-3: M=1 per 150: W= 1 per 75 ** CHURCH FUNCTIONS WOULD NOT ALLOW SIMULTANEOUS USE OF SANCTUARY AND MEETINGS ROOMS. THEREFORE,SANCTUARY LEVEL HAS BEEN USED FOR CALCULATIONS. EXIT REQUIREMENT CALCULATIONS (PER IBC 1005.1 & 10286.1.4) EXIT OCC. LOAD CALC OCCUPANTS WIDTH REQUIRED @.2"/OCC WIDTH PROVIDEDPROVIDEDEXIT A 50% OF NAVE 215 43" 72"50% OF MEETING RM 1015% OF MTG RM 102-107 EXIT B 50% OF NAVE 214 42.8" 72"50% OF MEETING RM 1015% OF MTG RM 102-107 EXIT C 90% OF MTG RM 102-108 96 19.2" 36" BUILDING CODE SUMMA APPLICABLE CODES:AS ADOPTED, MOD 2009 INTERNATIONAL BU 2009 INTERNATIONAL PL 2009 INTERNATIONAL ME 2014 NATIONAL ELECTR 2009 INTERNATIONAL FU 2009 INTERNATIONAL FIR 2009 INTERNATIONAL EN ICC/ANSI A117.1.2003 CONSTRUCTION TYPE:TYPE III-B (IBC 200 ALL MASONRY EXT INTERIOR CONSTR USE AND OCCUPANCY C MAIN OCCUPANCY SECONDARY: BUILDING HEIGHT AND A ALLOWABLE AREA: ALLOWABLE HEIG ACTUAL AREA: ACTUAL HEIGHT: FIRE PROTECTION SYST BUILDING IS FULLY BUILDING HEIGHT AND A FRONTAGE AREA IN SPRINKLER AREA A MIXED USE AND OCCUP CONSIDERED AS N MOST RESTRICTIVE BUILDING FALLS W NO FIRE-RESISTIVE The two stairwaysfrom the sanctuary level are open to each other and cometogether on the main level, providing only asingle exit from the sanctuary level. You exceed the common path travel distance (132' vs 75' allowed).Draft a letter to the building officialrequesting exemption from the required two exits, separation ofexits, and common path travel distanceper 2009 3409. If insulation is perforated, you must increase the thickness to achieve an area weighted average of R-10 minimum. Typically this requires 3" of R5/inch rigid insulation. If wall surrounding transformer is modified, contact City of Aspen Electric. STORAGE STORAGE BOILERROOM CRAWLSPACE CRAWLSPACE CRAWLSPACE R D A T EL.= 89'-7 1/2" COORDINATE WALL PENETRATIONSWITH DUCTWORK, RE: MECH 1 PROPOSED BASEMENT LEVELCONSTRUCTION PLAN You are performing structural andmechanicalimprovements to thecrawlspaces. Provide access to crawlspacesper 2009 IBC 1209.1. 9 4 2 A4.2 VEST.120 120B 120A A B STOR121 A3.5 1 EL.= 100'-0" 202 233 2'-6 1/2"8'-3 1/16"6" ALIGN, TYP. 231 234232 REFER TO A1.0 AND A3.5- A3.10FOR PROPOSED FRONT PORCHAND STEPS DESIGN.6"4'-1 1/4"6"4'-1 1/4"6"6'-7 3/4"5'-7 1/2"T" +/-DISPLAYDISPLAYREFDISPLAYALIGN, TYP. 4'-7 1/4"2'-1 9/16"4'-1 1/2"4'-1 1/2" ALIGN, TYP. 246 1'-4" 2'-3" 2'-2"EQ3'-7 3/8"EQ1'-4"121 42"H WALL A A TEL: 97 FAX: 9 Y CATHOLIC CHURCHThe new coffee counter/kitchenette must be accessible (2009 IBC 1109.4). Provide a detailed plan and elevations with clearances and dimensions shown. 1 2 3 4 1 SEE ATTACHED LETTER SEE UPDATED CIVIL DRAWINGS SEE UPDATED TRASH ENCLOSURE DRAWINGS SEE ATTACHED CRAWLSPACE DIAGRAM SHEET A2.5 & A8.3 5 City of Aspen Received 5/2/17 Building Department Page: 5 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 38 Enclosed usable areas beneath stairs must be protected with 1 hour fire rated walls and soffits per 2009 IBC 1009.6.3. Indicate this requirement on the plans and put listed assemblies on the plans. Page: 5 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 38 Provide the U factor of the new windows complying with 2009 IECC 502.3 or include the windows in your letter to the building official requesting historic exemption per 2009 IECC 101.4.2. Page: 5 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 38 If the reception counter is used for any sales or for the distribution of goods or services it must be accessible (2009 IBC 1109.11.3). Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 Provide an accessible route to the platform (2009 IBC 1108.2.8). Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 The centerline of the alter server vesting sink must be at least 24" off the finished face of the sidewall to allow for a 48" long accessible clearspace to be centered for a parallel approach. (ICC/ANSI A117.1-2003 606. CA8.3 4 1 3 2 1A4.1 ENTRY100 MEETINGRM102 HALL117 RECEPT118 OFFICE119 120B 120A 117 119 111A A8.3 8 6 5 7 100 E A B D MEETINGRM101 STOR122 122 101A102A 101B101C102C102B A6.1 1 STOR121 A3.5 1 EL.= 100'-0" 202 203 217 219 233 2'-6 1/2"8'-3 1/16"2'-1 7/16"12'-5" 10'-3 1/4"5'-2" 3'-7"3'-8"4'-4" ALIGN ALIGN, TYP. 231 231 234 234 232 A A A A A 1'-8"8A9.1 REFER TO A1.0 AND A3.5- A3.10FOR PROPOSED FRONT PORCHAND STEPS DESIGN.6"4'-1 1/4"6"4'-1 1/4"6"6'-7 3/4"5'-7 1/2"EXIST3'-6 1/8" +/-EXIST3'-6 1/8" +/-DISPLAYDISPLAYREFDISPLAYALIGN, TYP. 4'-7 1/4"2'-1 9/16"4'-1 1/2"4'-1 1/2" ALIGN, TYP.4'-10"246 246 246 1'-4" 2'-3" 2'-2"EQ3'-7 3/8"EQ1'-4"121 42"H WALL A A 1'-8" SHEET NO. JOB NO. PROPOSEDCONSTRUCTIONPLANSST. MARY CATHOLIC CHUR 533 E. MAIN STREETASPEN, COLORADOISSUE: DATE:50% DD SET 09/02/16100% DD SET 10/11/16DD ADDENDUM #1 11/14/1650% CD SET 12/20/16PERMIT DRAWINGS 1/12/17 Enclosed usable areasbeneath stairs must beprotected with 1 hour fire rated walls andsoffits per 2009 IBC1009.6.3. Indicate thisrequirement on theplans and put listedassemblies on theplans. 6 7 8 9 2A4.2 ANY ORTITIONOUSTIC FOR OFSHALL TABLE.OWS, RECEIVE MS TO BE TION IN O XISTING EFER CONSTRUCTION KEYNOTES 202 3CM GRANITE TRANSACTION TOP W. WOOD TRIM SURROUND AT OPENING. RE: ELEVS.203 3CM GRANITE COUNTER WITH 4" BACKSPLASH. STAINED WD BASE CABINETS W. RAISED PANEL DOORS.213 3CM GRANITE COUNTER TOP W. CUSTOM WOOD BASE CABIENTS AND UPPER CABINETS.217 DUAL-HEIGHT ADA DRINKING FOUNTAIN218 EXTEND (E) LANDING WITH 2X WD FRAMING AND PLYWOOD SUBSTRATE TO ALIGN WITH EDGE OF DOOR TRIM.MATCH EXISTING HEIGHT.219 P.LAM UPPER CABINETS, RE: ELEV.220 NEW OPERABLE PARTITION AND TOP TRACK, TYP OF (6). BASIS OF DESIGN: HUFCOR-642. UTILIZE (E) STRUCT.SUPPORTS ABOVE CEILING.221 (E) ROLL DOWN GRILLE AT KITCHEN TO REMAIN. 222 INFILL STUD WALL. MATCH ADJACENT CONSTRUCTION AND WALL TEXTURE.231 NEW STAINED GLASS WINDOW IN (E) OPENING. PROVIDE LINEAR LED BACK LIGHT FIXTURE. PROVIDE NEWACCESS PANEL ON INSIDE.232 NEW DRYWALL PILASTER 14" DEPTH.233 NEW GRANITE COFFEE COUNTER.234 REFINISH (E) WD STAIRS AND HANDRAILS. RE: FINISH PLANS.237 SAND & REFINISH (E) WDW FRAMES AND WDW SASHES, INSIDE AND OUT AND DOOR CASING/TRIM. REPLACENON-HISTORIC HDWARE W. ACCURATE HDWARE.238 NEW STORM WDWS ON EXTERIOR OF ALL WINDOWS, BOTH LEVELS.241 NEW CONCRETE STEPS AND SIDEWALK. RE: SITEPLAN244 LAVATORY COUNTER (ST-2)246 MULTIPLE 18" DEEP WOOD SHELVES (PAINT GRADE)AT 16" O.C. VERTICALLY. Provide the U factor ofthe new windows complying with 2009 IECC 502.3 or include the windows in your letter to the building official requesting historic exemption per 2009 IECC 101.4.2. CA8.3 4 1 3 2 1A4.1 ENTRY100 MEETINGRM102 MEETINGRM103 MEETINGRM104 MEETINGRM105 WOMEN110 HALLWAY111 MEN116 OFFICE113 OFFICE114 HALL115 HALL117 RECEPT118 OFFICE119 120A 117 119114 113A 110 111A 116 A8.3 8 6 5 7 100 E A B D MEETINGRM101 STOR122 122 101A102A103A104A105A 101B101C102C103C104C102B103B104B105B CONF RM112 A6.11 112 105C 113B STOR121 A3.5 1 EL.= 100'-0" 202 203 217 219 238 220 233 2'-6 1/2"8'-3 1/16"2'-1 7/16"12'-5"12'-5"12'-5"11'-11"9'-3 3/4"5'-0"GN 6'-0 1/4"ALIGN10'-3 1/4"5'-2" 3'-7"3'-8"4'-4" ALIGN ALIGN, TYP. 231 231 234 234 232 244 244B A A A A A A A A A A B AA 238 237 237 1'-8"8A9.1 REFER TO A1.0 AND A3.5- A3.10FOR PROPOSED FRONT PORCHAND STEPS DESIGN.6"4'-1 1/4"6"4'-1 1/4"6"6'-7 3/4"5'-7 1/2"EXIST3'-6 1/8" +/-EXIST3'-6 1/8" +/-DISPLAYDISPLAYREFDISPLAYALIGN, TYP. 4'-7 1/4"2'-1 9/16"4'-1 1/2"4'-1 1/2" ALIGN, TYP.4'-10"246 246 246 1'-4" 2'-3" 2'-2"EQ3'-7 3/8"EQ1'-4"121 42"H WALL A A 1'-8" COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. A2.5 PROPOSEDCONSTRUCTIONPLANSST. MARY CATHOLIC CHU 533 E. MAIN STREETASPEN, COLORADO 3/16" = 1'-0"1 PROPOSED MAIN LEVEL CONSTRUCTION PLAN ISSUE: DATE:50% DD SET 09/02/16100% DD SET 10/11/16DD ADDENDUM #1 11/14/1650% CD SET 12/20/16PERMIT DRAWINGS 1/12/17 If the receptioncounter is used for anysales or for thedistribution of goods orservices it must beaccessible (2009 IBC1109.11.3). 1 2 3 4 1 A4. VESTING /SACRISTY208 A8.313 14 15 16 A3.6 EL.= 114'-0 1/2" EL.= 114'-0 1/2" 213 214 213 215 212 208 209212 208 208 239 238 237 3'-9 1/4"8'-4 1/8"11'-2 5/8"3'-9 1/4"2'-4"1'-8"204 REF A A Provide an accessibleroute to the platform (2009 IBC 1108.2.8). ALTARSERVERVESTING209 A8.39 11 10 12 EL.= 114'-0 1/2" 213 214 213 215 209 237 238 11'-2 5/8"4' 212 212 A 3/16" = 1'-0"1 SANCTUARY The centerline of the alter server vesting sink must be at least 24" off the finished face of the sidewall to allow for a 48" long accessible clearspace to be centered for a parallel approach. (ICC/ANSI A117.1-2003 606. 6 7 8 9 2 SHEET A2.5 this window no longer in scope SHEET A8.3 SEE ATTACHED CUTSHEET 10 SHEET A2.6 City of Aspen Received 5/2/17 Building Department Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 The shafts for the ductwork are not shown on the main level plan. How do they connect to the lower level mechanical area and maintain fire rated shaft continuity? Ductwork penetrating non-fire-resistance-rated floor assemblies must be protected with either a shaft or fire dampers at each floor line if connecting 3 levels. If only connecting 2 levels, protect the annular space. (2009 IB 716.6.3). Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 Provide an accessible route into and out of both rooms of the confessional. One is a public access area, the other is an employee work area. (2009 IBC 1103.2.3, 1104.2) Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 You have seating for 354 people, requiring 6 wheelchair spaces. Spaces must be dispersed throughout the nave and each space requires a companion seat. If an audio amplification system is used, an assistive listening system is required. (2009 IBC 1108.2) Page: 6 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 39 Provide handrails to the platform (2009 IBC 1012). Page: 7 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 40 Door 302 is shown as 2'8" in the door schedule. It must allow 32" clear between jamb and leaf when open to 90 degrees (2009 IBC 1008.1.1). UP 1 2 3 4 5 9 A8.2 2 4 3 1 1A4.2 2A4.2 STAIR201 STOR202 STAIR203 NARTHEX204 VEST205 NAVE206SANCTUARY207 VESTING /SACRISTY208 ALTARSERVERVESTING209 (E) ROOF BELOW 205 CONFESSIONAL A8.313 A8.39 14 15 16 11 10 12 B C C A A 204B 204A A9.13 A3.61 A3.7 1 EL.= 114'-0 1/2" EL.= 115'-2 1/2" EL.= 114'-0 1/2" CONFESSIONALEL.= 114'-0 1/2" 202A 213 214 213 215 213 214 213 215 212 250 212 208 209 209 209 204 205 206 211 211 212 208 210 210 3'-8" 1'-9" 2'-7"4'-6"7 1/4" ALIGN 208 209 239 239 236 236 238 237 237 238 234 234 24 EL.= 112'-10 1/2" 3'-9 1/4"8'-4 1/8"11'-2 5/8"3'-9 1/4"10'-6"10'-6"3'-9 1/4"11'-2 5/8"4'-5"8'-4"8'-4"4'-5"EL.= 113'-4 1/2" EL.= 113'-4 1/2"204 2'-4"1'-8"2'-4"4'-4"204 204 EL.= 112'-10 1/2" 202B 212 ALIGN ALIGN 5A8.4 212 EQ.EXIST3'-0 3/4" 5'-10"1'-10"2'-7" 1'-2" 2'-5 1/2"3'-4"4'-8"1'-8"1'-2"REF V.I.F.50'-11 3/4"A9.21 212 249 212 212 11A7.10 245 2452'-6"2'-6"248 248 4'-0" A A AA 237 237 237 237 237 237 252 252 A A A A2.73 254 254 254 3/16" = 1'-0"1 SANCTUARY LEVEL CONSTRUCTION PLAN 250 NEW ALTAR, RE: DETAILS.251 EXISTING ENTRY CANOPY TO REMAIN.252 STAINED WOOD CASED OPENING254 PROVIDE LEVELING COMPOUND UNDER PEW AREA TO ACHIEVE LEVEL TRANSITION WITH NEW FINISHES IN AISLES.COORDINATE WITH FINISH PLANS. The shafts for the ductwork arenot shown on the main levelplan. How do they connect tothe lower level mechanical areaand maintain fire rated shaftcontinuity? Ductwork penetratingnon-fire-resistance-rated floorassemblies must be protectedwith either a shaft or firedampers at each floor line ifconnecting 3 levels. If onlyconnecting 2 levels, protect theannular space. (2009 IB716.6.3). STAIR203 E D CONFESSIONAL C A9.1 3 CONFESSIONAL 202A 205 211 210 ALIGN 2344'-5"EL.= 113'-4 1/2"204 ALIGN 5A8.4EQ.245 248 237 237 251 252 254 CTION PLAN Provide an accessible route into and out ofboth rooms of the confessional. One is a public access area, the other is an employee work area. (2009 IBC 1103.2.3, 1104.2) 2 You have seating for 354 people, requiring 6 wheelchair spaces. Spaces must be dispersed throughout the nave and each space requires a companion seat. If an audio amplification system is used, an assistive listening system is required. (2009 IBC 1108.2) 1 2 3 4 5 A8.2 2 41 1 A4.2 NAVE206SANCTUARY VESTING /SACRISTY208 A8.313 14 15 16 A3.6 1 A3.7 1 EL.= 114'-0 1/2" EL.= 115'-2 1/2" EL.= 114'-0 1/2" 213 214 213 215 212 250 208 209212 208 208 239 236 238 237 EL.= 112'-10 1/2" 3'-9 1/4"8'-4 1/8"11'-2 5/8"3'-9 1/4"10'-6"2'-4"1'-8"204 5'-10"1'-10"2'-7" 1'-2" 2'-5 1/2"3'-4"4'-8" REF V.I.F.0'-11 3/4"A9.2 1 212 11 2'-6"6"248 4'-0" A A 254 249 MODIFY EXISTING REREDOS AND HIGH ALTAR. RE: DETAILS.250 NEW ALTAR, RE: DETAILS.251 EXISTING ENTRY CANOPY TO REMAIN.252 STAINED WOOD CASED OPENING254 PROVIDE LEVELING COMPOUND UNDER PEW AREA TO ACHIEVE LEVEL TRANSITION WITH NEW FINISHES IN AISLES.COORDINATE WITH FINISH PLANS. Provide handrails to the platform (2009 IBC 1012). DN D OPEN TOBELOW BALCONY303 301 224 223 3 A7.111'-3 302 OPE BEL A A7.10 9 255 Door 302 is shown as 2'8" in the door schedule. It must allow 32" clear between jamb and leaf when open to 90 degrees (2009 IBC 1008.1.1). 11 12 13 14 3 no shafts penetrate floor; all ductwork goes UP see attached letter handrails to be provided as part of altar rail design 15 SHEET A2.6 SHEET A2.7 City of Aspen Received 5/2/17 Building Department Page: 19 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 52 Detail how you will air seal between the projector screen opening and the attic. Page: 19 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 52 Indicate the type of insulation used in the attic and demonstrate how the attic is vented. If not vented, provide dew point calculations. Page: 19 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 52 Verify that the space under the platform will not be used for storage or anything other than equipment, plumbing, and electrical. Otherwise you must frame the platform with 1 hour fire rated construction. (2009 IBC 410.4) Page: 20 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 53 Provide new stair tread and riser dimensions. Page: 20 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 53 Protect penetrations of 1 hour enclosed space under stair. CHOIR LOFT LEVEL 122'-4 1/2" EXIST. BELFRY LEVEL 136'-3 1/2" NEW CEILING RECONSTRUCT SANCTUARY ARCH, RE: 1/A4.2 FOR D NEW MOTORIZED PROJECTOR SCREEN. TYP OF 2 DEMO AND RECONSTRUCT CURVED CEILING, 3 SIDE HIGH ALTAR TO BE DISASSEMBLED, PROTECTED, AN OFFSITE STORAGE BY OWNER. NEW PLATFORM FRAMING, MECH DUCTWORK, RE: MECH Detail how you will air seal between the projector screen opening and the attic. 1 EXISTING TRUSS PACKS IN ATTIC NEW WD TRIM AT COFFERED CEILING, RE: DETAILS RECESSED SLOT FOR CONCEALED LIGHT FIXTURE PROVIDE NEW R-60 INSULATION THROUGHOUT ENTIREATTIC SPACE ABOVE CEILING AIR BARRIER. 6 A T F Indicate the type of insulation used in the attic and demonstrate how the attic is vented. If not vented, provide dew point calculations. MAIN LEVEL 100'-0" SANCTUARY LEVEL 112'-10 1/2" SANCTUARY207 CHOIR LOFT LEVEL 122'-4 1/2" CRAWLSPACE HIGH ALTAR TO BE DISASSEMBLED, PROTECTED OFFSITE STORAGE BY OWNER. NEW PLATFORM FRAMING,RE: STRUC INFILL WALL WHERE DOOR WAS REMOVED. EXTEND LANDING, RE: PLAN MECH GRILLE,RE: MECH MECH DUCTWORK,RE: MECH Verify that the space under the platform will not be used for storage or anything other than equipment, plumbing, and electrical. Otherwise you must frame the platform with 1 hour fire rated construction. (2009 IBC 410.4) SANCTUARY LEVEL 112'-10 1/2" CHOIR LOFT LEVEL 122'-4 1/2" NEW STAIR AND HANDRAIL NEW FLOOR STRUC, RE: STRUC (E) WD WAINSCOT TO REMAIN NEWWALL MNT'D STAINED WD HANDRAIL Provide new stair tread and riser dimensions. MAIN LEVEL 100'-0" SANCTUARY LEVEL 112'-10 1/2" CHOIR LOFT LEVEL 122'-4 1/2" ENTRY100 STAIR203 STAIR201 CRAWLSPACE STOR202 BALCONY303 STOR121 OOD GUARDRAILBALUSTERSOIR LOFT RAILING INSTALL (2) HISTORIC FXITURESFROM CHURCH NEW STAIR AND HANDRAIL NEW FLOOR STRUC, RE: STRUC NEW FIN. ON EXISTING STAIR FINISH AND PROTECT UNDERSIDEOF STAIR AS STORAGE SPACE,(2) LA OF GYP. BD. A7.108 A7.112A7.11 3 (E) WD WAINSCOT TO REMAIN NEWWALL MNT'D STAINEDWD HANDRAIL 1 3/16" = 1'-0"2 BUILDING SECTION - FACING SOUTH Protect penetrations of1 hour enclosed space under stair. 16 17 18 19 4 PROJECTOR ELIMINATED FROM SCOPE 20 SHEET A4.1 & A7.10 AND MECHANICAL DRAWINGS SHEET A4.2 SHEET A4.2 SHEET A2.6 City of Aspen Received 5/2/17 Building Department Page: 20 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 53 Provide handrail extensions and returns per 2009 IBC 1012.6. Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Dimension all grab bars, mirrors, and accessories. Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Show and dimension clear spaces at one urinal and lavatory in each toilet room as well as turnaround space. Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Dimension the accessible clearances. Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Dimension height of accessible urinal rim and toilet seat CHOIR LOFT LEVEL 122'-4 1/2" FROM CHURCH NEW STAIR AND HANDRAIL NEW FLOOR STRUC, RE: STRUC NEWWALL MNT'D STAINED WD HANDRAIL Provide handrail extensions and returns per 2009 IBC 1012.6.4'-6"A6.110 TILE TO 48 PARTITION ASSCHEDULED TILE BASE O 48"2'-10"4'-6"10A6.1 TILE UP TO 48" AFF PARTITION AS SCHEDULED TILE BASE REMOVEABLEAPRON WD PANEL2'-10"4'-0"TILE UP TO 48" AFF TILE UP TO 48" AFF WEST ELEVATIONNORTH ELEVATIONEAST ELEVATION 1/4" = 1'-0"7 WEST ELEVATIONMEN 116 1/4" = 1'-0"8 WEST ELEVATIONMEN 116 1/4" = 1'-0"6 SOUTH ELEVATIONMEN 116 Dimension all grabbars, mirrors, andaccessories. TA-10 18" GRAB BAR BOBRICK B-5806 X 18TA-11 WOOD GRAIN LAMINATE PARTITION MEN116 WOMEN110 A6.1 8 9 7 6 A6.1 5 2 3 4 1'-6" EQ EQ5'-0" CLR.6'-10 3/8" 5'-0" CLR 3'-1" 3'-1"7'-1 3/4" 5'-0" CLR. 11'-3" 2'-1 1/2" 3'-6" 3'-6" 2'-1 1/2"1'-4" 2'-4" 1'-4" TA-7 TA-6TA-2 TA-5TA-4 TA-10 TA-1 TA-3 TA-9 TA-8 TA-8 TA-10TA-1TA-2 TA-6 TA-8TA-7 TA-9 TA-11 TA-11 TA-9 4'-6"TILE TO 48" AFF TILE UP TO 48" AFF SHEET N JOB NO EN FLO ST. MARY CATHO 1/4" = 1'-0" SOUTH ELEVATION MEN 116 ISS 50% DD S 100% DD DD ADDEN 50% CD S PERMIT D Show and dimension clear spaces at one urinal and lavatory ineach toilet room aswell as turnaround space. REMOVEABLE WD APRON PER ADA CLEARANCES PROVIDE PLYWD BACKING IN WALL FOR ANCHORAGE OF WALL MOUNTED ITEMS. NOTE BACKERBOARD AND TILE WALLFINISH, PER ELEVATIONS2'-10" TO RIM OF SINK4"2"1 3/4"610 EAST HY ASPEN, CO TEL: 970.925 FAX: 970.92 cunniffe. RCHAT LAVATORY Dimension the accessible clearances.4'-0"4'-0"7 1/4" = 1'-0"8 WEST ELEVATION MEN 116 Dimension height of accessible urinal rim and toilet seat 21 22 23 24 5 25 SHEET A6.1 SHEET A6.1 SHEET A6.1 SHEET A6.1 SHEET A6.1 City of Aspen Received 5/2/17 Building Department Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Outlets must be within accessible reach range. Max height to center 44" if sink is greater than 20" deep. If less, then 48" max. Page: 21 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 54 Provide interior elevations of women's accessible water closet with dimensions. Page: 24 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 57 Dimension the guard height (42" min). Page: 24 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 57 Concealed combustible space will require sprinkler protection if space between bottom of joist and top of dropped ceiling framing is 6" or greater (NFPA 13 section 8.15.1.2.3) Page: 29 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 62 Provide handrails on both sides of all new or altered stairs (2009 IBC 1009.12). PARTITION PER PLAN, RE: ELEVATIONSFOR MIRRORS MOUNT OUTLETS 4" ABOVE COUNTERTOPTO BOT OF COVER PLATE. RE: ELEC. BACKSPLASH TRIM AT SIDES AND BACK.PROVIDE SEALANT WHERE MEETS TILE. SINK, RE: SPECS.COUNTERTOP, RE: FINISH SCHED 4""CH CU AR 610 cun Outlets must be within accessible reach range. Max height to center 44" if sink is greater than 20" deep. If less, then 48" max. TA-1 SEMI RECESSED TOILET TISSUE DISPENSOR BOBRICK B-3888TA-2 42" GRAB BAR BOBRICK B-5806 X 42TA-3 RECESSED SANITARY NAPKIN DISPOSAL BOBRICK B-353TA-4 PARTITION MNTD DUAL SANITARY NAPKIN DISPOSAL BOBRICK B-354TA-5 PARTITION MNTD DUAL TOILET TISSUE DISPENSOR BOBRICK B-386TA-6 36" GRAB BAR BOBRICK B-5806 X 36TA-7 MIRROR, POLISHED EDGES, FRAMELESS BOBRICK B-290TA-8 SEMI RECESSED PAPER TOWEL DISPENSOR BOBRICK B-359TA-9 RECESSED BABY CHANGING STATION BOBRICK KB110TA-10 18" GRAB BAR BOBRICK B-5806 X 18TA-11 WOOD GRAIN LAMINATE PARTITION TOILET ACCESSORIES SCHEDULE MEN116 WOMEN A6.1 8 9 7 6 3 1'-6" EQ EQ5'-0" CLR.6'-10 3/8" 5'-0" CLR 3'-1" 3'-1"5'-0" CLR.1'-4" 2'-4" 1'-4" TA-6TA-2 TA-5TA-4 TA-10 TA-1 TA-3 TA-10TA-1TA-2 TA-6 TA-8 TA-7 TA-9 TA-11 TA-11 TA-9TILE UP TO 48" AFF ENLARGE FLOOR PLA ST. MARY CATHOLIC CHURC 533 E. MAIN STREET 1" = 1'-0"10 SECTION AT LAVATORY 1/4" = 1'-0"6 SOUTH ELEVATION MEN 116 ISSUE: D 50% DD SET 0 Provide interiorelevations of women'saccessible watercloset with dimensions. 5 1/2" Dimension the guard height (42" min). PLYWD OVER WOOD FRAMINGRE: STRUC FIELD TILE, RE: FINISH PLAN 1" = 1'-0"8 DETAIL AT EXIST FLOOR Concealed combustible space will require sprinkler protection if spacebetween bottom ofjoist and top ofdropped ceilingframing is 6" or greater (NFPA 13 section 8.15.1.2.3) NEW STEP, RE: PLAN MODIFY EXISTING WALL HEIGHTAND WOOD WALL CAP TO MATCHNEW FLOOR STEP CONFIGURATION EDGE OF EXISTING WALL TO REMAIN MATCH (E) WD BASE REMOVE PORTION OF EXISTINGWALL TO ACCOMODATE NEWWALL HEIGHT Provide handrails on both sides of all new or altered stairs (2009 IBC 1009.12). 26 27 28 30 6 29 SHEET A6.1 SHEET A6.1 SHEET A7.10 SHEET A6.1 SHEET A2.6 & A8.4 City of Aspen Received 5/2/17 Building Department Page: Sheet: S0.0 - GENERAL NOTES File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 70 Provide a general notes sheet with structural design load specifications. Page: Sheet: S0.0 - GENERAL NOTES File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 70 Revise special inspection schedule to note which inspections require continuous vs. periodic inspection. Page: Sheet: S2.6 - PROPOSED - SANCTUARY FRAMING PLAN File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 80 Concealed combustible space under the platform must be provided sprinkler protection (NFPA 13 section 8.15.1.2.3). Page: Sheet: S7.1 - STEEL DETAILS File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 85 Provide a signed special inspection agreement form for the structural steel welds, high strength bolting, and epoxy anchors. Page: 35 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 92 How will the outside air intake and combustion air intake wells be kept clear of snow? Submitted photos show snow up against this side of the building. Move intakes to be above snow level. S8.2 WOOD DETAILS Provide a general notes sheet with structural design load specifications. ABBREVIATIONSINSUL INSULATION AB ANCHOR BOLTINT INTERIOR ABV ABOVEJNT JOINT ADH ADHESIVEJST JOIST ALT ALTERNATELOCN LOCATION ARCH ARCHITECTURAL LSL LAMINATED STRAND LUMBER AWS AMERICAN WELDING SOCIETYLVL LAMINATED VENEER LUMBER @ AT_ON CENTERLWC LIGHT WEIGHT CONCRETE BLW BELOWMATL MATERIAL BLDG BUILDINGMAX MAXIMUM BLK BLOCK MECH MECHANICAL BLKG BLOCKINGMFS MANUFACTURER BM BEAMMIN MINIMUM B.O. BOTTOM OF(N) NEW BRG BEARINGNA NOT APPLICABLE BOTT BOTTOMN.I.C. NOT IN CONTRACT BTWN BETWEENNO, # NUMBER C.I.P. CAST IN PLACE NS NEAR SIDE CL, ¡ CENTERLINEN.T.S. NOT TO SCALE CLG CEILINGNWC NORMAL WEIGHT CONCRETE CLR CLEARO/ OVER COL COLUMNOC ON CENTER CONC CONCRETE OH OPPOSITE HAND CONN CONNECTIONOPP OPPOSITE CONSTR CONSTRUCTIONOPNG OPENING CONT CONTINUOUSOSB ORIENTED STRAND BOARD CP COMPLETE PENETRATIONOWSJ OPEN WEB STEEL JOISTS CTR CENTERPDF POWER DRIVEN FASTENER DBL DOUBLEPERP PERPENDICULAR DET DETAIL PERIM PERIMETER DF DOUGLAS FIRPL, ¢ PLATE DF-L DOUGLAS FIR-LARCHPLWD PLYWOOD DIA DIAMETERPSL PARALLEL STRAND LUMBER DIAG DIAGONALPT POST TENSIONED OR DIM DIMENSION PRESSURE TREATED DWG DRAWINGREF REFERENCE (E) EXISTINGREINF REINFORCING EA EACHREQ'D REQUIRED EF EACH FACERET RETAINING EL ELEVATIONRO ROUGH OPENING EMBED EMBEDMENTRDWD REDWOOD EN EDGE NAIL S.A.D. SEE ARCHITECTURAL DRAWINGS EQUIP EQUIPMENTSCHED SCHEDULE EW EACH WAYSEL STRUCT SELECT STRUCTURAL EXP EXPANSION SFRS SEISMIC FORCE RESISTINGSYSTEM EXT EXTERIOR SHTG SHEATHING FNDN FOUNDATIONSIM SIMILAR FIN FLR, F.F. FINISHED FLOOR S.O.G. SLAB ON GRADE FLR FLOORSPEC SPECIFICATIONS F.O. FACE OFSQ SQUARE FRMG FRAMINGSS STAINLESS STEEL FS FAR SIDESTD STANDARD FT FOOTT & B TOP AND BOTTOM FTG FOOTINGT & G TONGUE AND GROOVE GA, ga GAGE TN TOE NAIL GALV GALVINIZEDT.O. TOP OF GR GRADETYP TYPICAL GL GLULAMU.O.N. UNLESS OTHERWISE NOTED GYP BD GYPSUM BOARDVERT VERTICAL HDG HOT DIPPED GALVANIZED WP WATER PROOFING OR HDR HEADERWORK POINT HGR HANGERWT WEIGHT HK HOOKWWF WELDED WIRE FABRIC HORIZ HORIZONTALW/ WITH HSB HIGH STRENGTH BOLTXS EXTRA STRONG HSS HOLLOW STRUCTURAL STEELXXS DOUBLE-EXTRA STRONG INFO INFORMATION CHARLESCUNNIFFEARCHITECTS 610 EAST HYMAN AVE.ASPEN, CO 81611TEL: 970.925.5590FAX: 970.920.4557 cunniffe.com GENERAL NOTESST. MARY CATHOLIC CHURCH533 E. MAIN STREETASPEN, COLORADOSPECIAL INSPECTIONSSPECIAL INSPECTION AND TESTINGA QUALIFIED SPECIAL INSPECTOR SHALL BE RETAINED TOPROVIDE SPECIAL INSPECTION. GFDS ENGINEERS SHALLNOT PROVIDE SPECIAL INSPECTION. SPECIALINSPECTION SHALL BE CARRIED OUT IN ACCORDANCEWITH IBC '09 CHAPTER 17. INSPECTIONBY: STEEL CONSTRUCTION (REF TABLE 1704.3) SP. INSP.HIGH-STRENGTH BOLTS, NUTS, AND WASHERS (PERIODIC)WELDS REQUIRING CONTINUOUS INSPECTION:CJP & PJP GROOVEMULTIPASS FILLETSINGLE-PASS FILLET > Ä"PLUG AND SLOTREINFORCEMENT BARS IN CONCRETEWELD REQUIRING PERIODIC INSPECTION:SINGLE PASS FILLET = Ä"FLOOR AND ROOF DECKWELDED STUDS IN STRUCTURAL DIAPHRAGMSCONCRETE CONSTRUCTION (REF TABLE 1704.4)CONCRETE SAMPLING - SLUMP, AIR CONTENT, ANDTEMPERATURE OF CONCRETE (CONTINUOUS)BOLTS INSTALLED IN CONCRETE (CONTINUOUS)CONCRETE AND SHOTCRETE PLACEMENT(CONTINUOUS)REINFORCING STEEL INCLUDING PLACEMENT(PERIODIC)POST INSTALLED ANCHORS (PERIODIC)VERIFYING USE OF REQUIRED DESIGN MIX (PERIODIC)LEVEL 1 MASONRY CONSTRUCTION (REF. TABLE 1704.5.1)MASONRY COMPRESSIVE STRENGTH PRIOR TOCONSTRUCTION (PERIODIC)SITE-PREPARED MORTAR AND MORTAR JOINTS(PERIODIC)PLACEMENT OF REINFORCEMENT, CONNECTORS,ANCHOR BOLTS (PERIODIC)GROUT SPACE IS CLEAN (PERIODIC)SOILS (REF TABLE 1704.7)GEOTECH.PROPER FOUNDATION DEPTH, VERIFICATION OFSUPPORTING STRATA (PERIODIC)X COMPACTED FILL MATERIALS, SUBGRADE, AND SITEPREPARATION (PERIODIC)X FOUNDATION UNDERPINNING AND/ OR SHORINGCAST-IN-PLACE DEEP FOUNDATION ELEMENTS (REFTABLE 1704.9)DRILLING OPERATIONS AND PIER CROSS SECTION ANDDEPTH (CONTINUOUS)STRUCTURAL WOOD (REF TABLE 1707.3) SP. INSP.WOOD SHEAR WALLSWOOD DIAPHRAGMSHOLDDOWNSSTRUCTURAL OBSERVATIONS GFDSENGINEERSSTRUCTURAL FOUNDATION XSTEEL FRAMING XCONCRETE CONSTRUCTION XMASONRY CONSTRUCTIONWOOD FRAMING X SHEET LISTS0.0 GENERAL NOTESS0.2 TYPICAL CONCRETE DETAILSS0.3 TYPICAL WOOD DETAILSS0.4 TYPICAL SHEAR WALL DETAILSS2.1 DEMOLITION - BASEMENT LEVEL PLANS2.2 DEMOLITION - MAIN LEVEL PLANS2.3 DEMOLITION - SANCTUARY LEVEL PLANS2.3.1 DEMOLITION - CHOIR LOFT & BELFRY FRAMING PLANSS2.4 PROPOSED - FOUNDATION PLANS2.5 PROPOSED - MAIN LEVEL FRAMING PLANS2.6 PROPOSED - SANCTUARY FRAMING PLANS2.7 PROPOSED - CHOIR LOFT & BELFRY FRAMING PLANSS2.8 PROPOSED - ROOF FRAMING PLANS4.0 PROPOSED - BUILDING SECTIONSS5.1 CONCRETE DETAILSS7.1 STEEL DETAILSS7.2 STEEL DETAILSS8.1 WOOD DETAILSS8.2 WOOD DETAILS ISSUE: DATE: Revise specialinspection schedule tonote which inspectionsrequire continuous vs.periodic inspection. A B D E @2x61'-4"(N) ¾" PLYWD OR AS REQ'DTO MATCH (E) FLOORSHEATHING DEPTH (E) MC10X22(E) MC10X22(E) MC10X22(E) 6.75x12(E) 6.75x12(E) 6.75x12(E) 6.75x12(E) W14X34 (2)1¾x11Í (2)1¾x11ÍCROSS HATCHED AREA INDICATESNEW RAISED PLATFORM WITH 2X6MIN OVERFRAMING W/ 6'-0" MAXSPAN. COORDINATE FRAMINGWITH INTEGRATED DUCTING LAYOUT. (2)1¾x11Í(2)1¾x11Í HEADERHEADERHEADER8 S0.3TYP (E) 3X11½" @16" W/(1) 1¾X11Í" REINF. JOISTS(E) 3X11½" @16" W/(1) 1¾X18" REINF. JOISTS(E) 3X11½" @16" (E) 3X11½" @16" W/(2) 1¾X11Í" REINF. JOISTS (E) 3X11½" @16" W/(1) 1¾X11Í" REINF. JOISTS (E) 3X11½" @16" W/(1) 1¾X18" REINF. JOISTS(E) 3X11½" @16" (E) 3X11½" @16" W/(2) 1¾X11Í" REINF. JOISTS (E) 3X11½" @16" (E) 3X11½" @16" Concealedcombustible spaceunder the platformmust be providedsprinkler protection(NFPA 13 section8.15.1.2.3). C F C 1 C S7 Provide a signed special inspection agreement form for the structural steel welds, high strength bolting, and epoxy anchors. (N) COMBINED BOILER VENTTHROUGH (E) CHIMNEY, FASNSEALFLEX TYPE OR EQUIVALENT,ESTIMATED 14"ø MAX, TO BEFINALIZED WITH VENDORENGINEERED BREECHING DESIGN. (E) BOILER COMBUSTIONAIR INTAKE AREA WELL.TO REMAIN. WELL. 61 A TE FA c How will the outside air intake and combustion air intake wells be kept clear of snow? Submitted photos show snow up against this side of the building. Move intakes to be above snow level. 31 32 33 34 35 7 City of Aspen Received 5/2/17 Building Department Page: 39 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 96 Indicate the provided headroom beneath the ductwork. Minimum 7' (2009 IBC 1208.2). Page: 39 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 96 Each boiler is greater than 400 kBtu, requiring two exit access doorways from the boiler room (2009 IBC 1015.3). Page: 39 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 96 Provide calculations determining minimum outdoor ventilation rates per 2009 IMC 403.3 for all occupied spaces. Page: 40 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 97 Thermostats must be within accessible reach range (2009 IBC 1109.12). Page: 41 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 98 Provide access to AHUs per 2009 IMC 306. ELEV EQUIP002 CEILING-HUNG FANCOIL UNIT. ELEV LOBBY001 12x3 OSAUP. STORAGE STORAGE BOILERROOM CRAWLSPACE CRAWLSPACE CRAWLSPACE B -1B -1 WH-1 8"ø TYP. SPACE FORHWS/RPUMPS. GF,ET, HX, ETC. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 12x12 24x12 14x12 14x12 18x12 24x1224x1234x1624x12 18x12 OSA 8ø8ø12x38ø8ø8ø24x1224x1218x12 18x12 14x12 14x12 14x12 14x12 18x12 14x12 FC -2 FC -3 FC -1 FC -4 FC -5FC -6 12x1212x1212x1212x1218x12 8ø 18x12SPACE FORCHW PUMPS.GF, ET, ETC. 1 1 1 1 1 FIELD COORDINATE DUCT ANDPIPE ROUTING WITH ELECTRICALTO AVOID ROUTING ABOVEELECTRICAL PANELS.8ø8ø8øBT -1ø10 ø10 ø10 ø10 (E) CRAWLSPACE VENILATIONTO REMAIN, TYP. Indicate the providedheadroom beneath theductwork. Minimum 7'(2009 IBC 1208.2). STORAGE STORAGE BOILERROOM CRAWLSPACE AWLACE CRAWLSPACE B -1B -1 WH-1 8"ø TYP. SPACE FORHWS/RPUMPS. GF,ET, HX, ETC. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 8"ø TYP. 14x12 14x12 18x12 24x1224x1234x1624x12 18x12 OSA 8ø8ø12x38ø8ø8ø24x1224x1218x12 18x12 14x12 14x12 14x12 14x12 18x12 14x12 FC -2 FC -3 FC -1 FC -4 FC -5FC -6 12x1218x12 8ø SPACE FORCHW PUMPS.GF, ET, ETC. 1 1 1 1 1 8ø8ø8øBT -1ø10 Each boiler is greater than 400 kBtu, requiring two exitaccess doorways fromthe boiler room (2009IBC 1015.3). Provide calculations determining minimum outdoor ventilation rates per 2009 IMC 403.3 for all occupied spaces. A C B TEL: 970.925.5 FAX: 970.920. THOLIC CHURCHAND LOCATION. ALL DUCTWORK SHALL BE ROUTED AS HIGHAS POSSIBLE IN THE CEILING SPACE.UTILIZE JOIST SPACE WHEN POSSIBLE,ESPECIALLY WHERE CROSSING OTHERDUCTS, PIPES, AND ELECTRICAL. ALL RA & SA RECTANGULAR DUCT TOINCLUDE 1" INTERNAL LINER, UNO. OSA ANDEXH DUCT SHALL BE UNLINED. CONNECT ALL SA AND RA DEVICES WITHINACOUSTIC FLEX DUCT, 5' MIN. & 8' MAXLENGTH. UTILIZE REMOTE BALANCE DAMPERS ILOOBD OR BALANCE DAMPERS AT GRILLE.FLEX DUCT TO BE LOCATED BETWEENDEVICE AND BALACE DAMPER, AS SHOWN. 11. 12. 13. 14. FLAG NOTES: WALL-MOUNTED THERMOSTATADJACENT TO LIGHT SWITCH,COORDINATE EXACT LOCATION ANDAPPEARANCE WITH ARCHITECT. CUSTOM DECORATIVE GRILLE, EITHER(1) CONTINUOUS WITH MULTIPLE DUCTCONNECTIONS, OR MULTIPLE MATCHING CONNECTION QTY. BELOW.TBD IN ARCH. COORD. CONNECT (N) EF-1 TO (E) EXHAUSTDUCT, WITH BDD. DUCT ROUTED IN JOIST SPACE TODIFFUSER. 1 2 3 4 Thermostats must be within accessible reach range (2009 IBC 1109.12). Provide access to AHUs per 2009 IMC 306. 36 37 38 39 40 8 City of Aspen Received 5/2/17 Building Department Page: 41 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 98 Ductwork in attic must be insulated to R5 per 2009 IECC 503.2.7. Page: 42 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 99 Provide access to AHUs per 2009 IMC 306. Page: 43 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 100 R-10 insulation is required under snowmelt. Page: 50 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 107 Detail where this drains to in your civil drawings. Page: 63 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 120 Provide a lower level lighting plan. LE CHARLESCUNNIFFEARCHITECTS 610 EAST HYMA ASPEN, CO 81 TEL: 970.925.55 FAX: 970.920.4 cunniffe.co CHURCHVERIFY ALL EQUIPMENT ACCESS PANELSWITH MANUFACTURER AND ARCHITECT. ALL SOURCES OF IGNITION ON MECHANICALEQUIPMENT SHALL BE MOUNTED 18" AFF. PROTECT PIPING ROUTED ALONGCOLUMNS, WALLS, ETC. FROM DAMAGE ASNECESSARY WITH CAGES. COORDINATEWITH ARCHITECT. ALL RETURN AIR GRILLES SHALL BEPROVIDED WITH SOUND BOOT WITH 1"LINER. T-STATS SHALL BE LOCATED NEAR THELIGHT SWITCH WITHIN THE ROOM SHOWN.COORDINATE WITH ARCHITECT &ELECTRICAL ENGINEER TO MATCH HEIGHTAND LOCATION. ALL DUCTWORK SHALL BE ROUTED AS HIGHAS POSSIBLE IN THE CEILING SPACE.UTILIZE JOIST SPACE WHEN POSSIBLE,ESPECIALLY WHERE CROSSING OTHERDUCTS, PIPES, AND ELECTRICAL. ALL RA & SA RECTANGULAR DUCT TOINCLUDE 1" INTERNAL LINER, UNO. OSA ANDEXH DUCT SHALL BE UNLINED. CONNECT ALL SA AND RA DEVICES WITHINACOUSTIC FLEX DUCT, 5' MIN. & 8' MAXLENGTH. UTILIZE REMOTE BALANCE DAMPERS ILOOBD OR BALANCE DAMPERS AT GRILLE.FLEX DUCT TO BE LOCATED BETWEENDEVICE AND BALACE DAMPER, AS SHOWN. 6. 7. 8. 9. 10. 11. 12. 13. 14. FLAG NOTES: 1 ACOUSTIC IMPACTS OF CUSTOMGRILLE TO BE EVALUATED, EXACT SIZE,AND CONFIGURATION TBD. Ductwork in attic must be insulated to R5 per 2009 IECC 503.2.7. S -2 AHU -1 Provide access to AHUs per 2009 IMC 306. SNOWMELT CONN NO SCALE R-10 insulation is required under snowmelt. SACRARIUM BASIN W ROUTED TO STORM/DAYLIGHT. REGULARBASIN W ROUTED TO SANITARYWASTE. Detail where this drains to in your civil drawings. Provide a lower level lighting plan. 41 42 43 44 45 9 City of Aspen Received 5/2/17 Building Department Page: 63 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 120 Provide light reduction controls per 2009 IECC 505.2.2.1. Page: 63 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 120 Provide emergency power to lights in the corridor. (2009 IBC 1006.3) Page: 63 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 120 Provide interior and exterior lighting COMchecks; lighting cutsheets with the maximum fixture wattage highlighted (should match COMcheck) and the NRTL listing highlighted. COMcheck must match lighting plans and lighting schedule. Page: 66 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 123 Controls and receptacles must be withing accessible reach ranges (2009 IBC 1109.12). Provide dimensions above floor. Page: 72 File Name: 00.Plans.Combined.pdf Subject: PlanCheck Author: nickt Color: Page Index: 129 Provide assistive listening system (2009 IBC 1108.2.7) oc SS oc DDDD D JJJ ococococ oc S S oc ococococococ SoSSSSSSSS S S oc oc oc SSS SoS SSC E B D 1 2 3 4 5 6 7 8 9 DP3 DP3 S3 R3 R3 R3 R1 R1 DP4 R2 R2 R1 R1 DW1DW1 R2ER2 R2 DP4 DP4 DP4DP4 DW1 DW1 DW1 DW1 R2 R2E R2 R2 (E)(E)(E)(E)DP3DP3DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 S2 S2 R5 X1X3X3 1 R5 R5 DP3 K K E3 E2 3 3 1 1 R2 R2 R2E R2ER2 R5 R5 R2E DP3 3 3 3 3 3 3 3 444 4 5 6 6 7 7 R2E R2E HALLWAY111 WOMEN110 MEN116 KITCHEN109 ENTRY100 MEETING RM101MEETING RM102MEETING RM103MEETING RM104MEETING RM105MEETING RM106MEETING RM107 STOR122 S3 S3 S3 S3 8 3 3 9 11 12 RECEPT118 S2 13131313 TOLIGHTSIN STAIRABOVE TO LIGHTSIN STAIRABOVE 15 15 E3 P1A-2P1A-4P1A-6P1A-8P1A-10P1A-12P1A-14 12P1A-20 M0-42 M0-42 M0-42 SCALE: 3/16" = 1'-0" MAIN LEVEL LIGHITNG PLANProvide light reductioncontrols per 2009IECC 505.2.2.1. oc SS oc DDDD D JJJ ococ ococ oc S S oc ococococococSSSSSS SS S S oc oc SSS SoSSoc A C E B D 1 2 3 4 5 6 7 8 DP3 R3 R3 R3 R1 R1 DP4 R2 R2 R1 R1 DW1DW1 R2ER2 R2 DP4 DP4 DP4DP4 DW1 DW1 DW1 DW1 R2 R2E R2 R2 (E)(E)(E)(E)DP3DP3DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 DP3 E1 R5 R5 X1 X3 X3X3 1 2 DP3 K K (E) E2 3 3 1 1 R2 (E)(E) R5 R5 R2E DP3 3 3 3 3 3 3 3 444 4 5 6 6 7 7 R2E R2E HALLWAY111 WOMEN110 MEN116 OFFICE113 CONF RM112 KITCHEN109 OFFICE114 OFFICE119 ENTRY100 MEETING RM101MEETING RM102MEETING RM103MEETING RM104MEETING RM105MEETING RM106MEETING RM107 S VEST.120 3 3 9 10 11 RECEPT118 13131313 1313 3 13 14 X4 15 15 15 P1A-22 P1A-2P1A-4P1A-6P1A-8P1A-10P1A-12P1A-14 P1A-5 P1A-20 M0-42 M0-42 M0-42 Provide emergencypower to lights in thecorridor. (2009 IBC1006.3) Provide interior and exterior lighting COMchecks; lighting cutsheets with the maximum fixture wattage highlighted (should match COMcheck) and the NRTL listing highlighted. COMcheck must match lighting plans and lighting schedule. WINDOW BACK SPLASH COUNTERTOP CL EQ EQ CL --6" MIN 20"MAX ALIGN POWER-BASED DEVICES(RECEPTACLES, SWITCHES,ETC.) VERTICALLY. DO NOTVERTICALLY ALIGN POWER ANDCOMMUNICATION DEVICESSIMULTANEOUSLY. Controls and receptacles must be withing accessible reach ranges (2009 IBC 1109.12). Provide dimensions above floor. MOUNT. HOMERUN CABLING TO REFER TO LOUDSPEAKER SCHE SHEET T0.1. REFER TO DIAGRAM SHEET T4.0 FOR MOUNTING. Provide assistive listening system (2009 IBC 1108.2.7) 46 47 48 49 50 10 City of Aspen Received 5/2/17 Building Department Page: 1 File Name: IBC building form.pdf Subject: PlanCheck Author: nickt Color: Page Index: 1 Submit an IBC building description form. IBC building form.pdf (1) Page: 1 File Name: REMP owrksheet_2017-01-18.pdf Subject: PlanCheck Author: nickt Color: Page Index: 1 SM1.1 shows 711sqft snowmelt new. The 243 sqft egress portion is exempted. REMP owrksheet_2017-01-18.pdf (2) Page: 1 File Name: REMP owrksheet_2017-01-18.pdf Subject: PlanCheck Author: nickt Color: Page Index: 1 Your snowmelt plan SM1.1 shows 487 sqft of existing snowmelt to be reused, this means you are only removing 620 sqft. Submit an IBC building description form. SM1.1 shows 711sqft snowmelt new. The 243 sqft egress portion is exempted. Your snowmelt plan SM1.1 shows 487 sqft of existing snowmelt to be reused, this means you are only removing 620 sqft. 51 52 53 11 City of Aspen Received 5/2/17 Building Department