Loading...
HomeMy WebLinkAboutFile Documents.520 N 8th St.0032.2017.ARBK0032-2017-ARBK_BuildingComments_2 Page: A-103 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Provide a fireplace registration form. 08.23.2017_520 N 8th Street_Architectural Sheets.pdf (8) Page: A-104 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Update the structurals to match the new overhang design (the overhang has increased) and any other changes. Page: A-104 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Indicate the flooring materials and colors of the hatch stairs, stair landing, threshold, and deck surface. All must contrast per the email discussion. Page: A-104 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Reference your 1 hour assembly on A501. Page: A-501 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Provide documentation (the ESR or UL report) to prove that you have a minimum Class B roof assembly. 3 2A-30118'-8 3/4"22'-9 1/4"ASPEN COLORADOPARCEL ID #273512114003520 N 8th StreetTHUNDERBOWLARCHITECTS(E) CONST. TO BE REMOVED OR NEW CONSTRUCTION EXISTING CONSTRUCTION Provide a fireplace registration form. C E FBD 1A-301 '-1"13'-6 3/4"10'-1 5/8"3'-3 1/2"22'-0 3/8" DN 1/8":1'1/8":1'1/8":1' 1/8":1' 1/8":1'1/8":1'1/8":1' 1/8":1' 1/8":1' 1/8":1'3'-0"EXISTING ARCHITECTURAL CHIMNEYFEATURES TO REMAIN - TYPICAL ALL CHIMNEYS HANDRAIL ATTACHED TO GUARDRAILAT JUNCTION OF HATCH AND ROOF DECK - LIMIT DISCONTINUITY TOEXTENT POSSIBLE - PROVIDE FULLLANDING AT TOP OF STAIRS EVENWITH ROOF DECK SURFACE NEW SLIDING CURB MOUNTED ROOF ACCESS HATCH - ROLLAMATIC OREQUIVALENT PROPERTY LINE 5'-0"3'-6"5'-0"2'-0"2'-0"2'-0" 3A-301 FROM 12A-502 12A-502 MAKE UP AIR AND AIR INTAKE TS Update the structuralsto match the newoverhang design (theoverhang hasincreased) and any other changes. DN 1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'1/8":1' 1/8":1 '1/8":1'1/8":1' :1' 1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1' 1/8":1'3'-0"EXISTING ARCHITECTURAL CHIMNEYFEATURES TO REMAIN - TYPICAL ALLCHIMNEYS LOW ROOF NON - CON ENCROACH ROOF DECK 301 TOP OF FFEL. = 120'-0" CONTINOUS AROUND EN AND ROOF HANDRAIL ATTACHED TO GUARDRAILAT JUNCTION OF HATCH AND ROOFDECK - LIMIT DISCONTINUITY TOEXTENT POSSIBLE - PROVIDE FULLLANDING AT TOP OF STAIRS EVENWITH ROOF DECK SURFACE NEW SLIDING CURB MOUNTED ROOFACCESS HATCH - ROLLAMATIC OREQUIVALENT PROVIDE DOWNLIGHT POLE MOUNTEDFIXTURE AT HATCH ENTRY TO ROOFDECK FULLY ROO TREX 31 32 18'-10 3/4"PROPERTY LINE 5'-0"3'-6"5'-0"2'-0"2'-0"2'-0" 3A-301 MECHANICAL ROOMBOILERHRVPOWDER EXHAUST UP CHASE BOILERSUPPLY DOWN CHASE MAKE UP AIR AND AIR INTAKE BATHROOM VENTS BATHROOM VENTS BATHROOM VENTS BATHROOM VENTS Indicate the flooringmaterials and colors ofthe hatch stairs, stairlanding, threshold, anddeck surface. All mustcontrast per the emaildiscussion. 3 1 A C EBD 2 A- 24'-1"13'-6 3/4"10'-1 5/8"3'-3 1/2" DN ":1'1/8":1'1/8":1'1/8":1'8":1'/8":1'1/8":1'1/8":1' 1/8":1' 1/8":1' 1/8 ": 1'1/8" :1 ' 1/8" : 1' 1/8":1' 1/8":1' 1/8":1' 1/8":1'3'-0"EXISTING ARCHITECTURAL CHIMNE FEATURES TO REMAIN - TYPICAL A CHIMNEYS ROOF DECK301 TOP OF FFEL. = 120'-0" EXISTING ROOF DRAIN LOCATIONS TOBE REUSED TO EXTENT POSSIBLE HANDRAIL ATTACHED TO GUARDRAILAT JUNCTION OF HATCH AND ROOFDECK - LIMIT DISCONTINUITY TOEXTENT POSSIBLE - PROVIDE FULLLANDING AT TOP OF STAIRS EVENWITH ROOF DECK SURFACE NEW SLIDING CURB MOUNTED ROOFACCESS HATCH - ROLLAMATIC OREQUIVALENT PROVIDE DOWNLIGHT POLE MOUNTEDFIXTURE AT HATCH ENTRY TO ROOFDECK 32 VENT FOR GAS APPLIANCE PROPERTY LINE 5'-0"5'-0" 2'-0 " 2'-0 " 3A-301 NOTE:ALL EVES TO BE 1HR RATED WHEN <5' FROMPROPERTY LINE.PER IRC 2009 R302.1 12A-502 12A-502 MECHANICAL ROOMBOILERHRVPOWDEREXHAUST UP CHASE BOILERSUPPLY DOWN CHASE MAKE UP AIR AND AIR INTAKE BATHROOM VENTS BATHROOM VENTS BATHROOM VENTS BATHROOM VENTS Reference your 1 hourassembly on A501. Provide documentation (theESR or UL report) toprove that you have aminimum Class B roofassembly. form is included again with this submission complete all existing overhangs to remain are not increasing - sheet A104X (existing) and A104 (proposed) - we have attached an updated structural sheet that matches our roof plan updated on A-104 ESR 1463 has been provided to demonstrate that we will will have a minimum of Class B - we have circled several ways this can be achieved with subcontractor input 12/22/2017 Page: A-501 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: Revise W-6/A-501 to reference the RC 2601 1 hour assembly on A501. Page: G-001 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: I will wait to sign off until you have abated the asbestos and submitted a report. Page: G-001 File Name: 08.23.2017_520 N 8th Street_Architectural Sheets.pdf Subject: PlanCheck Author: nickt Color: I have not received a special inspection agreement signed by the owner. Please provide it. Revise W-6/A-501 toreference the RC 26011 hour assembly onA501. CTORY Tel: (970) 618-1645Email: matthew@thunderbowlarchitects.com Tel: (310) 746-8887 Tel: (970) 945-8676 Email: rneal@hceng.com Tel: (970) 748-4520 Email: taylor@aec-vail.com Tel: (970) 925-8360 Email: scott@schlumbergerconstruction.com NOT INCLUDED IN THIS SET INCLUDED IN THIS SET DELETED FROM SET Tel: (970) 945-1006 Email: bob@oddogws.com Email: JamieAlexanderTisch@icloud.com PROJECT SCALE GENERAL INFORMATION SHEET 16030.00 G-001 DATE 03/13/2017 PERMIT SET I will wait to sign off until youhave abated the asbestos and submitted a report. Tread TerrazzoThick Tempered TEL. T.C. T.B. T. THK. T.M.E. T.&G. TER. TEMP. To Match Existing Towel BarTop of CurbTelephone Tongue & Groove REQ. RESIL. REINF. REG. REV. REMOV. R.O. RM. RET. Rough Opening Required RemovableRoom Resilient Retaining ReinforcedRegisterMountedMullion Nominal North Number New Miscellaneous Not in Contract MUL. MISC. MTD. NOM. N.I.C. N. (N) ONS NO. or # Revision/Revised/Reversed LORADO h Street SET 3, 2017 G001 COVER Z002 WALL DEMO CALCS Z003 ROOF DEMO CALCS Z004 LOWER LEVEL FLOOR AR A101-X EXISTING LOWER LEVEL A102-X EXISTING MAIN LEVEL A103-X EXISTING UPPER LEVEL A104-X EXISTING ROOF PLAN Z006 UPPER LEVEL FLOOR ARE Z001 ZONING SUMMARY A101-D DEMO LOWER LEVEL A102-D DEMO MAIN LEVEL Z005 MAIN LEVEL FLOOR ARE A103-D DEMO UPPER LEVEL A101 A102 A103 A104 A201-X A202-X A202 A201 A301-X A301 A501 A502 A601 LOWER LEVEL MAIN LEVEL UPPER LEVEL ROOF PLAN EXISTING ELEVATIONS EXISTING ELEVATIONS PROPOSED ELEVATIONS PROPOSED ELEVATIONS EXISTING BUILDING SEC PROPOSED BUILDING SEC ASSEMBLIES AND DETAIL DETAILS WINDOW AND DOOR TY G002 AREA PLANS A001 PROPOSED SITE PLAN A602 INSULATION SCHEDULE A702 A701 A703 PROP LOWER LEVEL RCP PROP MAIN LEVEL RCP PROP UPPER LEVEL RCP Z007 ROOF LEVEL FLOOR ARE A001-X EXISTING SITE PLAN I have not received a special inspection agreement signed by the owner. Please provide it. attached attached complete 12/22/2017