Page: A-001
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide an existing site plan
520 N 8TH ST PERMIT SUBMISSION.pdf (14)
Page: A-001
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
If there is to be any snowmelt,
provide the following:
1. Snowmelt plan showing
square footage.
2. RREMP worksheet
3. Insulation detail
Page: A-101
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide access to the
crawlspace, including the new
crawlspaces created by closing
off the tops of the pool and spa
(2009 IRC R408.4).
Page: A-102
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide access to the underfloor
space created by the
overframing at the new media
room. (2009 IRC R408.4).
Page: A-102
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide the finish floor level of
the landings on each side of the
new exterior door 111 as well as
the threshold height. (2009 IRC
R311.3)
7890'
7909.85'7890'19'-10 3/1
7901.68'7891'
7909.85'7892'17'-10 3/1
7909.85'7891.5'18'-4 3/16
7908.68'18'-10 3/1
11'-1 3/4"
7890'
7890'
7890.68'
7892'
7891.5'
SAME
SAME
EXISTING
SAME
SAME
PROPOSED SITE PLAN
1/4" = 1'-0"
1
A-001
Provide an existing
site plan
(10.1')
TRASHENCLOSURE
IRR. DITCH
18" C.M
.
P
.
EXISTING CONCRETE DRIVEWAY FLAGSTONEPATH
E
WS
G
B
MB
CO
SHED
FOUND REBAR AND ORANGEPLASTIC CAP LS28643
S14°50'49"W 138.21'
N14°19'
4
6
"
W
1
3
8
.
2
7'N75°11'36"W 60.18'(N74°06'24"W 60.11')(N13°11'45
"
W
1
3
8
.
5
7
'
)
(BASIS OF BEARINGS)
10' REAR BUILDING SETBACK
15' SIDE BUILDING SETBACK15.0'
10' FRO
N
T
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
10.0'7
15
18
19
20
21
22 23
18" C.M.P.
APPROX. LOCATION OF C.M.P.OTHER END NOT LOCATED
ASPHALT(TYP.)ALLEY7890
7891
7892
7891
789278917890
AT GARAGE7889.85'7892.81'AT ENTRY
C
7891
7891.9'
7892.1'
7890.7'
7891.4'
SITE BENCHMARK
ELEV: 7892.08'
GHTH ST
R
E
E
T
7892
78907891
EXISTING
TO REMAIN
16'-1 12"8'-0"FENCETO REMAIN
CONCRETEPATIO
TO BE REPLACED
EXISTING WALLSTO REMAIN
EXISTING WALLTO REMAIN
FENCETO REMAIN
EXISTING
FLAGSTONE PATH
TOP OF THRESHOLDTOP OF CONCRETE
CITY OF ASPEN BLOCK: 8 LOT: A&B13,256 SQ.FT.±100'-0" = 7889.85'
EXISTING MECHANICAL ACCESSTO REMAIN
EXISTING PORTION OF HOUSE WITHIN THE REAR SETBACK WILL NOTBE INCREASED IN ANY NON-CONFORMITY RELATIVE TO THEELEMENTS WITHIN THE PROPERTY SETBACK
1
2 3
45
ROOF DECK
ELEVATION #GRADE ELEVATION ROOF HT. OVERTOPOGRAPHY ACTUAL ROOF HT.OVER RESTRICTIVE GRADE
7890'
2 7909.85'7890'19'-10 3/16"
3 7901.68'7891'
4 7909.85'7892'17'-10 3/16"
5 7909.85'7891.5'18'-4 3/16"
7908.68'18'-10 3/16"1
(PROPOSED)
ROOF HEIGHT OVER TOPOGRAPHY
11'-1 3/4"
GRADE ELEVATION
7890'
7890'
7890.68'
7892'
7891.5'
(EXISTING)MOSTRESTRICTIVE
SAME
SAME
EXISTING
SAME
SAME
SURVEYORVERIFICATION 520 N 8th StreetPR
PROPOS SITE PLA
1/8
If there is to be any snowmelt, provide thefollowing:1. Snowmelt plan showing square footage.2. RREMP worksheet3. Insulation detail
Provide access to the
crawlspace, includingthe new crawlspacescreated by closing offthe tops of the pooland spa (2009 IRCR408.4).
Provide access to theunderfloor spacecreated by theoverframing at thenew media room.(2009 IRC R408.4).
Provide the finish floor
level of the landings
on each side of the
new exterior door 111
as well as the
threshold height.
(2009 IRC R311.3)
Existing survey has has been provided that accurately
represents existing conditions. Existing site plan has also
been added to the sheet set (Sheet A-001-X). Sheet index
on sheet G-001 has been updated to show changes.
We have incorporated a small amount of snow melt on the roof
deck at the exterior of the hatch as well as some limited snow
melt on the front walk. We have included a RREMP worksheet
as well as the insulation information on the insulation schedule.
See sheet A-001 for snow melt areas
Crawl space access locations have been provided and
called out on plans. The access for this area will be
provided from the existing mechanical crawlspace that is
accessed from a door on the outside of the home.
See sheets A-101 & A-102
A crawl space access hatch has been added in the closet
in Hall 114.
See sheet A-102 for note.
Elevations have been called out, as well as threshold
height on door 111.
See sheet A-102.
09/22/2017
Page: A-102
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Show all handrails in plans.
Ends must return. (2009 IRC
R311.7.7.2)
Page: A-102
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide a fireplace registration
form listing all fireplaces. If any
are gas log inserts, provide full
details complying with 2009 IRC
ch 10. If factory built appliances,
demonstrate compliance with
manufacturer's installation
instructions and provide the
instructions.
Page: A-104
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide details on the curb
mounted roof access hatch
clearly demonstrating
compliance with what we
discussed over email.
Page: A-202
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
The east elevation is less than 3'
from the property line. 2009 IRC
R302.1 does not allow any
windows at that distance. No
new windows may be added.
Existing windows pose a hazard.
Walls and eaves must be 1 hour
fire rated (provide assemblies).
We should meet to discuss.
Page: A-202
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Window 25 must be safety
glazed due to proximity to the
tub and shower. (2009 IRC
R308.4)
Show all handrails in
plans. Ends must
return. (2009 IRC
R311.7.7.2)
Provide a fireplace registrationform listing all fireplaces. If anyare gas log inserts, provide fulldetails complying with 2009 IRCch 10. If factory built appliances,demonstrate compliance withmanufacturer's installationinstructions and provide theinstructions.
C E FBD
3
1
2
2A-301
1A-301
13'-6 3/4"10'-1 5/8"3'-3 1/2"22'-0 3/8"6'-8"18'-8 3/4"22'-9 1/4"DN
1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'1/8":1'
1/8":1'
1/8":1'
1/8":1'
/8":1'
8":1'
1/8":1'1/8":1'
1/8
":
1/8":1'1/8":1'1/8":1'
1/8"
:1
'
1/8":1'
1/8":1'
1/8":1'
1/8":1'
1/8":1'
1/8":1'3'-0"3'-0"
EXISTING CHIMNEY FEATURES TOREMAIN - TYPICAL ALL CHIMNEYS
LOW ROOF TO NOT EXCEED EXISTINGNON - CONFORMITY RELATIVE TOENCROACHMENT WITHIN SETBACK
ROOF DECK
301
TOP OF FFEL. = 120'-0"
CONTINOUS GUARDRAIL AT 36" A.F.F.AROUND ENTIRETY OF ROOF DECKAND ROOF DECK ACCESS HATCH
HANDRAIL ATTACHED TO GUARDRAILAT JUNCTION OF HATCH AND ROOFDECK - LIMIT DISCONTINUITY TOEXTENT POSSIBLE - PROVIDE FULLLANDING AT TOP OF STAIRS EVENWITH ROOF DECK SURFACE
NEW HINGED CURB MOUNTED ROOFACCESS HATCH - BABCOCK DAVIS OREQUIVALENT
PROVIDE DOWNLIGHT POLE MOUNTEDFIXTURE AT HATCH ENTRY TO ROOFDECK
FULLY ADHERED MEMBRANEROOF W/ DECORATIVE BALLAST
TREX DECKING OR SIMILAR
30
32
14'-3 7/8"TOP OF FFEL. = 120'-0"
ROOF PLAN
GENERAL NOTES
1.
2.
ROOF MATERIALS ARE SHOWN - PATTERNS ARE ILLUSTRATI
ALL DIMENSIONS ON THIS PLAN ARE TO FACE OF FINISH,
Provide details on thecurb mounted roofaccess hatch clearlydemonstratingcompliance with whatwe discussed overemail.
T.O. EXISTING ROOFEL. = +118' 10"
T.O. F.F. @ MAIN LEVELEL. = +100' 0"
T.O. F.F. @ ENTRYEL. = +103' 0"
T.O. F.F. @ UPPER LEVELEL. = +108' 11"
1A-301 C B AEFD
11
17 18 19 20 21
12 13 14 15 16
PROPOSED GRADE
EXISTING GRADE18'-9 3/4"22'-4 1/8"18'-10"EXISTING CHIMNEY FEATURES TOREMAIN - TYPICAL ALL CHIMNEYS
22'-4 1/8"22'-4 1/8"20'-0"2A-301 51234
T.O. EXISTING ROOFEL. = +118' 10"
16 22 23 24 25
0"23'-1 1/2"EAST ELEVATION1/4" = 1'-0"1A-202
The east elevation is less than 3' from theproperty line. 2009 IRC R302.1 does notallow any windows at that distance. No newwindows may be added. Existing windowspose a hazard. Walls and eaves must be 1hour fire rated (provide assemblies). Weshould meet to discuss.
A-301
25
8'-10"Window 25 must be
safety glazed due to
proximity to the tub
and shower. (2009
IRC R308.4)
Handrails with returns have been shown.
See sheets A-102 & A-103.
These are gas appliances. Manufacturers information
has been provided.
More information on the roof access hatch has been
provided. See sheet A-301 for new stair section. All
points discussed over email have been shown. Roof
hatch will be custom size that is manufactured by
Rollamatic or similar (rollamatic.com).
The wall from Grid line D to Grid line A is 5' from the property line.
These are existing openings and new windows will be installed. The
wall from Grid line D to Grid line F is 3'6" from the property line and will
be fire rated (see sheets A-501 & A-502). All eves on the East side of
the house will be fire rated (see Sheets A-501 & A-502). Window 11
has been removed (proposed window numbering has been updated on
all drawings).
Window 25 on sheet A-202 is now shown as tempered.
09/22/2017
Page: A-301
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Show the thermal envelope in
the sections throuhout. Are the
crawlspaces part of the thermal
envelope? If not, they must be
vented. Detail your approach
complying with 2009 IRC R408.
Page: A-501
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide documentation that your
proposed roof assembly is a
minimum Class B rated
assembly (Ordinance 30, 2011).
Depending on the roofing
product, an underlayment may
be required. This is typically an
ESR or UL report. Revise roof
details to match the report.
Revise drawings as necessary to
match report requirements.
Page: G-001
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide an asbestos abatement
clearance report.
Page: G-002
File Name: 520 N 8TH ST PERMIT SUBMISSION.pdf
Subject: PlanCheck
Author: nickt
Color:
Include the area covered by the
pergola as fire area. If total is
greater than 5000 sqft, provide
a sprinkler system. (Ordinance
31, 2011)
Page: 3
File Name: Mechanical Design Narrative - 3-13-2017.pdf
Subject: PlanCheck
Author: nickt
Color:
Locate all equipment and
provide access on the plans.
Mechanical Design Narrative - 3-13-2017.pdf (5)
LOWER LEVEL
C E GBDF
MECHANICAL PROJECT
SCALE
PROPOSED
BUILDINGSECTIONS
1/4" = 1'-0"
16030.00
A-301ASPEN COLORADOPARCEL ID #273512114003520 N 8th StreetDATE
PROPOSED BUILDING SECTION E/W
1/4" = 1'-0"
1A-301
PROPOSED BUILDING SECTION N/S
1/4" = 1'-0"
2A-301
Show the thermalenvelope in thesections throuhout.Are the crawlspacespart of the thermalenvelope? If not, theymust be vented. Detailyour approachcomplying with 2009IRC R408.
INTERIOR
INTERIOR
Provide documentation that your
proposed roof assembly is aminimum Class B rated assembly(Ordinance 30, 2011). Depending onthe roofing product, anunderlayment may be required. Thisis typically an ESR or UL report.Revise roof details to match the
report. Revise drawings asnecessary to match reportrequirements.
Provide an asbestos abatement
clearance report.
Include the area
covered by the
pergola as fire area. If
total is greater than
5000 sqft, provide a
sprinkler system.
(Ordinance 31, 2011)
520 N. 8th St Design Assist Narrative Page 3 of 11 March 13, 2017 -Electric Heating Mats Provide electric heating mats for each of the main level bathrooms, and laundry room as the sole source of heating. Exact shape and coverage to be determined in the field to achieve the following minimum heat outputs/areas based on standard 12 W/sf electric mats. • Laundry 101 – 720 W (60 sf) • Bathroom 104 – 84 W (7 sf) • Bathroom 106 – 408 W (34 sf) • Bathroom 107 – 552 W (46 sf) -Fan Coils Provide fan coils based upon performance requirements shown below. Precise location of fan coils TBD, but general locations are as follows: Main level units in mechanical room or full height crawl space. Upper level unit in possible attic spaces above Bedroom 108 / Media room, or in mechanical room or crawl space using chases through the main level. Supply grilles shall be linear bars placed around perimeter or positioned to provide conditioned air to wash the windows. Return grilles shall be high in rooms to prevent stratification. All grilles shall be sized to limit noise to 25 N.C. Consider noise mitigation when placing units and extensively coordinate access with Architects and Interior Designers. -Condensing Units Provide a condensing unit (at least 2-stage) for each fan coil sized to properly match the cooling load. All condensing units shall be placed on the roof with clearances and line set lengths coordinated with the manufacturer. Precise location and screening TBD to limit visibility. Final placement to adhere to local sound ordinances. Fan Coil Number Area Served Heating Load (MBH) Cooling Load (MBH) Airflow (cfm)* 1 Living, Entry 44 50 3100 2 Kitchen, Dining (MUA) 113 36 2200 3 Upper Level 33 36 2200 *Sized for 55°F discharge air for cooling. Ensure heating/cooling capacities are met and coordinate airflow with manufacturer at altitude.
Locate all equipmentand provide access on
the plans.
The converted crawlspace will be part of the thermal
envelope. Drawings have been updated to show rigid
insulation on the interior of the foundation wall.
See sheets A-101, A-301, A-501 (Detail W-4), & A-602
The roof assembly has been updated to show "Class A"
rating. Underlayment has been noted.
See assembly R-1 on sheet A-501.
Asbestos abatement has been completed. We are awaiting
the final clearance report and will resubmit it prior to building
permit.
There was an error in our math when we originally
calculated the total area. We have included the pergola
within the fire area and still remain under 5000 sqft.
See sheet G-002
This information has been added to
the Architectural drawings.
09/22/2017
Page: 4
File Name: Mechanical Design Narrative - 3-13-2017.pdf
Subject: PlanCheck
Author: nickt
Color:
Indicate dryer duct routing and
termination on plans.
Page: 4
File Name: Mechanical Design Narrative - 3-13-2017.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide a whole house
ventilation system. Provide one
line drawing showing ductwork
and exterior intake.
Page: 10
File Name: Mechanical Design Narrative - 3-13-2017.pdf
Subject: PlanCheck
Author: nickt
Color:
Note 22 requires contractor to
use a complete set of MEP
drawings prior to starting work.
Provide those drawings. One
line drawings are acceptable for
building department review.
Page: 10
File Name: Mechanical Design Narrative - 3-13-2017.pdf
Subject: PlanCheck
Author: nickt
Color:
Locate all wall and roof
penetrations and dimension
them from openings.
Page: 2
File Name: Special Inspections.pdf
Subject: PlanCheck
Author: nickt
Color:
Special inspection agreement
must be signed by the owner.
Special Inspections.pdf (1)
until call for cooling is met. MUA (Fan Coil FC-1) – Upon a call for make-up air from kitchen hood (no heating call), enable heating coil in FC-2, P-5 shall start and the 3-way mixing valve shall modulate to provide 70F (adj) supply air temperature based upon the supply air sensor in the supply duct until call for make-up air is met. Upon a call for heat, the valve shall modulate to provide 90F supply air. Exhaust Fans – Bath exhaust fans to be controlled by wall switches. The garage exhaust fan shall be interlocked with a carbon monoxide sensor & wall switch. Whenever carbon monoxide is detected, the fan shall run until the levels drop. The wall switch shall enable fan operation, but not disable it if carbon monoxide is detected. Interlock mechanical room fan with cooling only thermostat and damper on outside air duct. Energy Recovery Ventilator- Shall include percentage timer and point of use controller. Notes: Dryer vents shall be routed directly to exterior and not exceed 30 equivalent feet (unless allowed by manufacturer). For 2 or more dryers, provide transfer grille.
Indicate dryer duct
routing and
termination on plans.
520 N. 8th St Design Assist Narrative Page 4 of 11 March 13, 2017 -Energy Recovery Ventilators (ERV’s) The total ventilation rate shall be at least 200 cfm (according to ASHRAE 62.2) and connected into the return duct for FC-1. The ventilation rate can be achieved using (1) RenewAire EV200. Some exhaust fans can be eliminated and replaced with return air vents to the ERV’s to provide more pressure balance. -Make-Up Air / Economizer Provide 1200 cfm (size to match hood exhaust) of make-up air to kitchen area, interlock controls with kitchen hood. An insulated outdoor air duct shall route from an exterior louver (location TBD) and connect to a return mixing box on FC-2. Verify size of kitchen hood with owner prior to install, contractor to balance MUA with exhaust and revise heat requirements as needed. -Humidification Provide Nortec RH2 humidifier (or equivalent) on FC-1 & FC-3. Ensure proper space is available for straight, unlined supply duct on either side of humidifier nozzle (precise length coordinated with manufacturer), with sloped pan and drain. Sequence of Operations
Provide a whole house ventilation
system. Provide one line drawing
showing ductwork and exterior
intake.
520 N. 8th St Design Assist Narrative Page 10 of 11 March 13, 2017 CONTRACTOR TO TEST CONDITIONS PRIOR TO SYSTEM FILL. WATER SOFTENERS OR OTHER DEVICES MAY BE REQUIRED TO IMPROVE WATER QUALITY. b. INCLUDE CORROSION INHIBITORS ON ALL PROPYLENE GLYCOL MIXTURES. c. PRIOR TO SYSTEM FILL, ALL TUBING SYSTEMS AND MANIFOLDS SHALL BE CLEANED AS PRESCRIBED BY THE TUBING MANUFACTURER. SUPPLY ALL TOOLS, CONNECTIONS, LABOR, AND ACCESSORIES NECESSARY TO PROPERLY REMOVE ALL FOREIGN MATERIAL, CHEMICAL, AND RESIDUE WITHIN THE TUBING SYSTEM BEFORE PERMANENTLY CHARGING THE SYSTEM AND PLACING INTO OPERATION. 22. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL EXAMINE A COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED, AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE BUILDING STRUCTURE AND THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR. 23. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT TRADES, AND PROVIDE WATERTIGHT FLASHINGS WHEREVER PENETRATIONS OCCUR. EXACT LOCATIONS AND SIZES MAY BE DEPENDENT UPON EQUIPMENT SELECTIONS; COORDINATE SIZES AND LOCATIONS OF ALL OPENINGS WITH APPROPRIATE EQUIPMENT REQUIREMENTS. 24. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30" CLEAR
Note 22 requires contractor to
use a complete set of MEP
drawings prior to starting work.
Provide those drawings. One
line drawings are acceptable
for building department
review.
520 N. 8th St Design Assist Narrative Page 10 of 11 March 13, 2017 CONTRACTOR TO TEST CONDITIONS PRIOR TO SYSTEM FILL. WATER SOFTENERS OR OTHER DEVICES MAY BE REQUIRED TO IMPROVE WATER QUALITY. b. INCLUDE CORROSION INHIBITORS ON ALL PROPYLENE GLYCOL MIXTURES. c. PRIOR TO SYSTEM FILL, ALL TUBING SYSTEMS AND MANIFOLDS SHALL BE CLEANED AS PRESCRIBED BY THE TUBING MANUFACTURER. SUPPLY ALL TOOLS, CONNECTIONS, LABOR, AND ACCESSORIES NECESSARY TO PROPERLY REMOVE ALL FOREIGN MATERIAL, CHEMICAL, AND RESIDUE WITHIN THE TUBING SYSTEM BEFORE PERMANENTLY CHARGING THE SYSTEM AND PLACING INTO OPERATION. 22. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL EXAMINE A COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED, AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE BUILDING STRUCTURE AND THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR. 23. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT TRADES, AND PROVIDE WATERTIGHT FLASHINGS WHEREVER PENETRATIONS OCCUR. EXACT LOCATIONS AND SIZES MAY BE DEPENDENT UPON EQUIPMENT SELECTIONS; COORDINATE SIZES AND LOCATIONS OF ALL OPENINGS WITH APPROPRIATE EQUIPMENT REQUIREMENTS. 24. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30" CLEAR WORKING SPACE IN FRONT OF ACCESS PANELS TO THE COMPRESSOR, BLOWER ASSEMBLY AND AIR FILTER SECTION OF THE EQUIPMENT SHALL BE PROVIDED BY GENERAL CONTRACTOR. 25. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURE WITH CODE APPROVED VIBRATION ISOLATORS.
Locate all wall and
roof penetrations and
dimension them from
openings.
Special inspection
agreement must be
signed by the owner.
This information has been added to
the drawing.
This information has been clarified
with the updated Mechanical
Narrative.
Per discussion with Taylor Critchlow
at AEC - we have rewritten the
narrative to indicate that these are not
required.
This information has been added to
the drawing.
This signature has been provided by owner.
09/22/2017
Page: S2.3
File Name: Structural Set .pdf
Subject: PlanCheck
Author: nickt
Color:
If a hot tub is ever expected to
be placed on the roof deck,
indicate on the structurals that
the load is accounted for.
Structural Set .pdf (1)
If a hot tub is ever
expected to be placedon the roof deck,
indicate on the
structurals that theload is accounted for.
The submitted structural drawings are accounting for this
hot tub load as noted. TJI spacing will go from 18" o.c. to
12" o.c. underneath the hot tub area - if provided in the
future.
09/22/2017