c. (HCE) recei
tions documen
comments is a
neering are un
mpany
ived commen
nts and drain
attached with
nderlined and
nts from the C
nage study for
responses.
in red.
Lan
City of Aspen
r the site locat
nd Surveyin
ted at
ng
10/10/2017
0032
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
Provide trench drain slope and
detail.
Civil Set .pdf (8)
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
The max curb cut is 18ft with 3ft
wings.
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
How will irrigation ditch be
protected during construction?
Will the CMP under driveway
remain during construction?
If any portion of the ditch is
being replaced provide details.
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
Is the existing water line being
modified or retained? If there is
any water line work proposed
call out abandonment plans and
proposed water line plans.
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
The architectural plans show a
foundation 9ft deep in places.
How will this foundation be
installed? Provide excavation
stabilization plans.
Provide trench drain
slope and detail.
The max curb cut is
18ft with 3ft wings.
How will irrigation
ditch be protected
during construction?Will the CMP under
driveway remain
during construction?If any portion of the
ditch is being
replaced provide
details.
Is the existing water
line being modified or
retained? If there is
any water line work
proposed call out
abandonment plans
and proposed water
line plans.
Trench drain slope has been added to grading plan and
trench drain detail has been added to details sheet.
Driveway curb cut has been revised to meet standards.
Erosion control logs and additional silt fencing has been
added to plans to protect ditch during construction. CMP
will remain, and no portion of the ditch is to be replaced.
Existing water line will be retained.
No new foundations are being poured outside the existing
building footprint-everything is existing to remain.
10/10/2017
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
Provide profile view of pipes.
Call out pipe size, type and
slope on plan view.
Page Index: 5
Author: jackd
File Name: Civil Set .pdf
Show asphalt patch according to
city of aspen Construction and
Excavation standards.
Page Index: 7
Author: jackd
File Name: Civil Set .pdf
There are multiple dimensions
here that are inconsistent with
the plan, specifically diameter.
Make sure that all dimensions
are correct.
Page Index: 12
Author: jackd
File Name: Drainage Report 520 N 8th-Stamped.pdf
Verify tree canopy credit with
areal photography and more
detailed calculations.
Drainage Report 520 N 8th-Stamped.pdf (1)
Provide profile viewof pipes.Call out pipe size,type and slope onplan view.
Show asphalt patch
according to city ofaspen Constructionand Excavation
standards.
There are multiple
dimensions here that
are inconsistent with
the plan, specifically
diameter. Make sure
that all dimensions
are correct.
BASIN AREA (S.F.) IMPERVIOUS AREA (SF) PERCENT IMPERVIOUS PR-1 5,187 5,016 96.7%PR-2 5,707 45 0.8%
PR-3 1,342 78 5.8%PR-4 996 121 12.1%
TOTAL 13,232 5,260 39.7%
Table 3. Tree Canopy Credit and Proposed WQCV
TREE CANOPY CREDIT
TREE TYPE
CANOPY AREA (SF)
CONIFEROUS 2,503.0
DECIDUOUS 3,640.0
IMPERVIOUSNESS
SITE TOTAL AREA 5,260
EFFECTIVE AREA 3,963 EFFECTIVE (%) 29.9%
WQCV (watershed-inches) 0.065 Volume (CF) 67.3
D. Operation and Maintenance
The drywell will need to be inspected and cleared of rubbish and debris quarterly to make sure that the filter/riser pipe has not become clogged and is functioning properly. The top three inches of the lower chamber infiltration media shall be scarified yearly or more frequently to obtain optimum infiltration of surface runoff. If water is pooling, then the filter material may need to be scarified more frequently. If the filter material continues to fail, then the top six
Verify tree canopy
credit with areal
photography and
more detailed
calculations.
Pipe size, type and slope has been added to plan view of
the grading plan. With the approval of the city engineer,
profile views have not been provided.
Drywell dimensions have been revised and updated.
An additional exhibit has been provided in the drainage
study to verify tree canopy credit.
Asphalt patch is now shown on site and grading plans.
10/10/2017