HomeMy WebLinkAboutFile Documents.520 E Hyman Ave.0158.2018 (6).ARBK520 E Hyman_BuildingComments_1
Page: A0.0 COVER SHEET
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
A special inspection is required
for the structural steel welding
and high strength bolting.
Please submit a special
inspection agreement with all of
the required signatures.
Architectural plans.pdf (6)
Page: A0.4 FIRE AREA AND SNOWMELT/RE
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
REMP worksheet provided does
not match the summary on A0.4.
Revise the REMP worksheet
and/or snowmelt plan so that
they match.
Page: A2.3 LEVEL 3 FLOOR
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
Wall W-5 is for an interior/interior
condition. Provide correct wall
callout and detail.
Page: A3.3 LEVEL 3 REFLECTED CEILING PLAN
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
Revise reflected ceiling plan to
show smoke detector in Bed 2
and Bed 3. 907.2.11
Page: A7.2 WALL ASSEMBL
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
Include the listing for U465 in the
detail pages the way you have
for the other listed assemblies.
ELECTRICAL CODE:NEC 2014
FIRE / LIFE SAFETY:IFC 2015
FLUE GAS CODE:IFGC 2015
ACCESSIBILITY:ICC / ANSI
A117.1-2009
CITY OF ASPEN MANICIPAL CODE TITLE 8
A special inspection is required
for the structural steel welding
and high strength bolting. Please
submit a special inspection
agreement with all of the required
signatures.
EXISTING SNOWMELT583 SF
PROPOSED SNOWMELT
PROPOSED SPA WATER AREA45 SF
SNOWMELT/REMP AREA SUMMARY
LEVEL 3 DECK AREAROOF DECK AREATOTAL EXISTING (CREDIT)
EXISTING SNOWMELT:
580+5831,163
SFSFSF
LEVEL 3 SNOWMELT AREAROOF DECK SNOWMELT AREAROOF CONDENSER SNOWMELT AREATOTAL PROPOSED SNOWMELT AREA
PROPOSED SNOWMELT:
483584+961,163
SFSFSFSF
EXISTING SNOWMELTPROPOSED SNOWMELTNO CHANGE IN AREA
CHANGE IN SNOWMELT AREA:
1,163-1,1630
SFSFSF
CUSTOM SPA AREA
SPA AREA
45 SF
E: 1/8" = 1'-0"
OF LEVEL GROSS/FIRE AREA PLAN
E: 1/8" = 1'-0"
OF LEVEL EXISTING SNOWMELT PLAN
REMP worksheetprovided does notmatch the summary
on A0.4. Revise the
REMP worksheetand/or snowmelt planso that they match.
UP
306
CORRIDOR
305
KITCHEN
PLANTING
BED
318
R PATIO
LCE)
CL SINK/REF/AISLE
314
313
A8.12
5
A8.12
6
A8.12
6
NISH
MS ABOVE315
316
A4.2
1 ALIGNART WALL
W-1
A7.2
1"
W-5
A7.2
2 HR,
BELOW
Wall W-5 is for an
interior/interior
condition. Provide
correct wall callout
and detail.
D
A4.3
2DE F G 3
A5.1
2
A5.1D.4
M
BE
314
BED 2
315
BATH 2
FCL9' - 4"
FCL8' - 6"
SKYLIGHT
EF
FCL8'-6"
R1
R1R1
R1
R1
R1
R1
R1R2
R2
P2
P3
S2
S2
S5 S5
S3
S3
T1
T1R1
B.O. B 9' - 4"
B.O. BEAM9' - 4"
MOTORIZED SHADE
POCKET
SUPPLY AIR
GRILL
RETURN AIR GRILL
RETURN AIR GRILL
R
RETURN AIR
GRILL
SUPPLY AIR
GRILL
THERMOSTAT
ELECTRICAL SWITCH
(X = 2-WAY, 3-WAY,ETC.)
ELECTRICAL SWITCH -
DIMMABLE
SCONCE
RECESSED -
DIRECTIONAL
D
X
T
Revise reflected ceiling
plan to show smoke
detector in Bed 2 and
Bed 3. 907.2.11
RE: PLANS
INTERIOR
SELF-FURRING METAL LATH
7/8" MIN. THICK, THREE COAT SMOOTH STUCCO PLASTER
PLYWOOD OR NON-COMBUSTIBLE FIBERGLASS MAT
GYPSUM AS REQ, RE: STRUCT
VAPOR PERMEABLE WEATHER BARRIER
INTERIOR
RE: PLANS
NOTE: SEE UL LISTING U465 FOR ADDITIONAL INFORMATION AT
RATED WALLS
EXTERIOR
INTERIOR FRAMED WALLS W/ UNFACED BATT INSULATION,RE: RATED ASSEMBLIES FOR ADDITIONAL INFORMATION
RE: PLANS
INTERIORINTERIOR
5/8" GWB
SCALE:A7.2 3" = 1'-0"
W-2 EXTERIOR WALL W
SCALE:A7.2 3" = 1'-0"
W-1 EXTERIOR WALL WITH STUCCO
Include the listing for U465
in the detail pages the way
you have for the other listed
assemblies.
R+B: Please see attached
special inspections report
R+B: Please see attached
revised REMP worksheet
R+B: Please see attached revised
A2.3 LEVEL 3 FLOOR and A5.2
BUILDING SECTIONS sheets. W-5
below window sill, W-1 above
window sill
R+B: Please see attached
revised A3.3 LEVEL 3
REFLECTED CEILING
PLAN
R+B: Please see attached
sheet A7.5 ASSEMBLY
RATINGS
12/27/2018
Page: A8.10 WINDOW SCHEDULE AND ELEVATIONS
File Name: Architectural plans.pdf
Author: bonniem
Subject: PlanCheck
Color:
Confirm with a plan note and/or
cutsheet that skylights will be
laminated glass with a 30 mil
polyvinyl butyral interlayer.
2405.3
BED 3 / 316
MARK: 401, 402, 403 & 404
6'-8"3'-2"EXISTING GABLE ROOF
SKYLIGHTS
2' - 0"2' - 6"10 3/4"1'-6"Confirm with a plan
note and/or cutsheet
that skylights will be
laminated glass with a
30 mil polyvinyl butyral
interlayer. 2405.3
R+B: Please see attached revised sheet A8.10
WINDOW SCHEDULE AND ELEVATIONS, refer to
note '6' under the 'WINDOW SCHEDULE
GENERAL NOTES' at the bottom of the sheet
12/27/2018