HomeMy WebLinkAboutFile Documents.520 E Hyman Ave.0158.2018 (16).ARBK aec Architectural Engineering Consultants, Inc. ` An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24,Suite 214,Eagle-Vail, CO 81620 Post Office Box 8489,Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com:www.aec-vail.com May 4th, 2018 Bryan May & Adam Link Rowland+Broughton Architecture 234 E Hopkins Ave Aspen, CO 81611 Re: Kagan Residence Dear Bryan & Adam, This document is intended to show compliance of the remodel of the Kagan Residence at Units 3A & 3B of 520 E Hyman Ave, Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to use a prescriptive approach per sections R402.1-R402.3 and R403.2.1 of the 2015 IECC. Project The project at 520 E Hyman Ave is a remodel of the existing penthouse apartment with a floor area of 2,915 sf. For heat load calculations, please refer to the Appendix. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project climate zone (7). All new assemblies will meet the following requirements. Fenestration U-factor Skylight U-factor Ceiling R-value Wood frame wall R-value Floor R-value Basement wall R-value Slab R-value Code Minimums 0.28 (1) 0.55 49 20+5 or 13+10 (2) 38 (3) 15/19 (4) 10 (5) Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) First value is cavity insulation, second value is continuous insulation 3) Or insulation sufficient to fill the framing cavity, R-19 minimum 4) R-15 continuous insulation on the interior or exterior, or R-19 cavity insulation on the interior of the basement wall. Can be satisfied with R-13 cavity plus R-5 continuous 5) 4 ft deep and R-15 edge insulation for heated slabs Sincerely, Alex Timberlake Mechanical Engineer 06/11/2018 Zone Sizing Summary for Whole House Load Project Name: 18008 - Kagan HLHG (1)05/03/2018 Prepared by: AEC 11:25AM Air System Information Air System Name Whole House Load Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 2655.0 ft² Location Aspen, Colorado Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft² Zone 1 51.5 4052 4052 Aug 1400 40.5 2655.0 1.53 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name /Sensible of Flow Load Area Space Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft² Zone 1 302 LIVING RM 1 12.1 Sep 1400 887 7.5 380.0 2.33 303 DINING ROOM 1 5.6 Jul 1500 412 4.5 410.0 1.01 304 KITCHEN 1 13.4 Jul 1500 980 9.8 555.0 1.77 307 DEN/BEDROOM 1 5.6 Oct 1300 410 3.2 155.0 2.65 308 BATH 1 0.4 Jul 1500 28 0.3 45.0 0.63 309 MASTER BEDROOM 1 6.6 Sep 1300 484 5.2 315.0 1.54 316 MASTER CLOSET 1 0.2 Jul 1500 17 0.2 35.0 0.49 315 MASTER BATH 1 1.4 Jul 1500 101 0.6 95.0 1.07 314 CORRIDOR 1 2.1 Jul 1400 151 1.3 135.0 1.12 310 BEDROOM 1 3.1 Jul 1400 228 2.2 155.0 1.47 311 BATH 1 0.5 Jul 1500 39 0.7 50.0 0.77 312 BED/BUNK ROOM 1 3.4 Jul 1500 252 4.0 255.0 0.99 313 BATH 1 0.8 Jul 1500 61 0.9 70.0 0.87 Hourly Analysis Program v4.50 Page 1 of 1 MANUAL J DESIGN CONDITIONS WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS OUTDOOR TEMPERATURE -15 °F OUTDOOR TEMPERATURE 82 °F INDOOR TEMPERATURE 70 °F INDOOR TEMPERATURE 75 °F TOTAL HEAT LOSS 40,535 BTU/HR SENSIBLE HEAT GAIN 55,250 BTU/HR LATENT HEAT GAIN 2,940 BTU/HR TOTAL HEAT GAIN 58,190 BTU/HR 06/11/2018