Loading...
HomeMy WebLinkAboutFile Documents.219 N Monarch St.0179.2017 (2).ARBK0179-2017-ARBK_BuildingComments_1 Page: 1 File Name: 1700-24 219 N. Monarch - Permit 7-25-17.pdf Subject: PlanCheck Author: nickt Color: The special inspection agreement form must be signed by the contractor. 1700-24 219 N. Monarch - Permit 7-25-17.pdf (3) Page: 1 File Name: 1700-24 219 N. Monarch - Permit 7-25-17.pdf Subject: PlanCheck Author: nickt Color: Revise the special program schedule on S1.0 to include the epoxy anchors (2015 IBC 1705.1.1) Page: 5 File Name: 1700-24 219 N. Monarch - Permit 7-25-17.pdf Subject: PlanCheck Author: nickt Color: Provide a design for the wood trellis. Page: [4] 17042-M1.0, M1.1-M1.0 File Name: 17042-Permit-072117.pdf Subject: PlanCheck Author: nickt Color: Provide cutsheets and installation instructions for the dryer booster fan demonstrating that it is listed to UL 705 and that the proposed installation is in compliance with the instructions. 2015 IMC 504.5 17042-Permit-072117.pdf (3) Page: [4] 17042-M1.0, M1.1-M1.0 File Name: 17042-Permit-072117.pdf Subject: PlanCheck Author: nickt Color: Show your calculations used to arrive at the CFM and %continuous rate for the ERV. Use this equation from Ordinance 40, 2016: Min vent rate = ((0.01 x floor area) + [7.5 x (#bedrooms + 1)]) x 0.75 Revise control sequence note to specify the number of hours it will run for in each 4 hour period. The special inspection agreement formmust be signed by the contractor. Revise the specialprogram schedule onS1.0 to include theepoxy anchors (2015IBC 1705.1.1) Provide a design forthe wood trellis. 7/21/17 Provide cutsheets andinstallation instructionsfor the dryer boosterfan demonstrating thatit is listed to UL 705and that the proposedinstallation is incompliance with theinstructions. 2015 IMC504.5 7/21/17 Show your calculations used to arrive at the CFM and %continuous rate for the ERV. Use thisequation from Ordinance 40, 2016:Min vent rate = ((0.01 x floor area) + [7.5 x (#bedrooms + 1)]) x 0.75Revise control sequence note to specify the number of hours it will run for in each 4 hour period. Fan is UL 705 listed and meets code. Cutsheet and Installaion instructions are attached. The calculation has been added to sheet M1.0 and the sequence on sheet M4.1 has been updated to call for continuous operation of ERV-1. 11/27/17 Page: [5] 17042-M1.0, M1.1-M1.1 File Name: 17042-Permit-072117.pdf Subject: PlanCheck Author: nickt Color: Provide a plumbing plan with isometric (or flatometric) showing which fixtures will drain into the lift station sump. Only those fixtures that cannot drain to the sewer by gravity may drain to the lift station. 2015 IPC 712.1 Page: 9 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Revise site plan to dimension the building from the property line and locate the building per the line grade form. 219 N Monarch Permit Set.pdf (31) Page: 10 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Provide a state demo license Page: 20 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Line grade form has a typo; 100' should equal 7897' as shown on civils. Page: 31 File Name: 219 N Monarch Permit Set.pdf Subject: Crawlspace access Author: nickt Color: Provide access to the crawlspace(s) per 2015 IRC R408.4. If mechanical equipment is located inside, access must be sized and located per 2015 IMC 306. Pay attention to the maximum distance from access to equipment. 7/21/17 Provide a plumbingplan with isometric (orflatometric) showingwhich fixtures will draininto the lift stationsump. Only thosefixtures that cannotdrain to the sewer bygravity may drain tothe lift station. 2015IPC 712.1 ON GRADE GROUT SET PATIO; IMPERVIOUS PERVIOUS SODDED AREAS EXIST. TREE; TYP.78967896789 PR PROPERTY LINE3,076 s Revise site plan to dimension thebuilding from the property line and locate the building per the line grade form. DEMO EXIST. STRUCTURE Provide a state demolicense Line grade form has atypo; 100' shouldequal 7897' as shownon civils. 004 004 011 010 5 4 2 G G F F 1 3 22'-10" 8'-4"1'-0"3'-8"1'-0"1'-31/2"3'-0"1'-0"8'-4"4'-8"1'-0"1'-0"3'-0"1'-31/2"001 002 W1 TYP. U.N.O. W4 W4 8.7 3 1 24 8.7 7 5 68 BEDROOM #4005 BEDROOM #5001 CLOSET #5002 CLOSET #4006 A5.1 C5.3 14.3 Provide access to thecrawlspace(s) per2015 IRC R408.4. Ifmechanical equipmentis located inside, access must be sizedand located per 2015IMC 306. Pay attentionto the maximumdistance from access to equipment. This is not listed under the City of Aspen's permit requirements and plumbing design was not in our scope of work. If needed, the plumbing contractor can provide these. 11/27/17 Page: 32 File Name: 219 N Monarch Permit Set.pdf Subject: Door landings Author: nickt Color: At all exterior doors, including upper level decks, provide the elevation of the landing on each side of the door and the height of the threshold above the landings (this can be spot elevations and/or details). Doors may not swing over a greater than 1 1/2" threshold. Distance from exterior landing to top of threshold may be a max of 7 3/4" if door does not swing over the step. (2015 IRC R311.3) Page: 32 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Show the location of the electric panel. Page: 32 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Revise floor plans to show window callouts as shown on the elevations. Page: 32 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Provide spot elevations at all changes in level. Page: 33 File Name: 219 N Monarch Permit Set.pdf Subject: Snowstops Author: nickt Color: Provide snow stops at all locations where roofs could shed snow onto walkways, stairs, alleys, decks, exits, utilities, emergency escape and rescue opening window wells, or adjacent properties per Ordinance 40, 2016. 101101b 5 6 7 4 DE G F 10'-2"13'-01/8"3'-0"51/2"B5.2 X6.1 14.3 24.3 UP W2 W5 W3 BREAKFASTAREA104 At all exterior doors, including upper level decks,provide the elevation of the landing on each sideof the door and the height of the threshold above the landings (this can be spot elevations and/ordetails). Doors may not swing over a greaterthan 1 1/2" threshold. Distance from exteriorlanding to top of threshold may be a max of 73/4" if door does not swing over the step. (2015 IRC R311.3) 101 F 3'-0"51/2"24.3 UP W2 BREAKFASTAREA 104 Show the location of the electric panel.ASPEN, CO219 MO 1703 ISSUE PROJECT No: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED MAIN LEVEL PLAN 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS 06/28/2017PERMIT SET 5 6 7 4 4'-6"7'-3"18'-10"B5.2 TERRACE110 Revise floor plans to show window callouts as shown on the elevations. 1 1 F X6.1 UP Provide spot elevations at all changes in level. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED UPPER LEVEL PLAN 3.3 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET N 201 208 207 204 202 203 205 206 209 210 A A 55 66 77 44 B B C C D D E E 22 G G F F 11 33 A5.1A5.1 B5.2 B5.2 X6.1 C5.3C5.3 D5.4 D5.4 15.5 15.5 #DrgID#LayID 14.1 14.3 14.4 24.3 45'-0" 51/2"6'-3"51/2"12'-0"51/2"8'-101/2"51/2" 12'-2"51/2"2'-1"51/2"4'-10"51/2"8'-7"51/2"14'-7"51/2" 51/2"5'-5"2'-10"8'-53/4"51/2" 51/2"3'-0"6'-0"3'-2"FLATROOF BELOW DECK201 PLATE HEIGHT @ 113'-6"DN PLATE HEIGHT @ 108'-0" W6 W5 ELEV. W1TYP. U.N.O. W2 W2 W2 PLATE HEIGH T @ 110'-5" GUEST SUITE206 MASTER BEDROOM201 MASTER CLOSET203 MASTER BATHROOM202 DN OWNERS CLOSET204 OPEN TOBELOW GUESTBATHROOM207GUEST CLOSET #1205 6:12 8:124:128:12 02'4'8'SCALE: 1/4" = 1'-0"1 UPPER LEVEL PLAN Provide snow stops atall locations whereroofs could shed snowonto walkways, stairs,alleys, decks, exits,utilities, emergencyescape and rescueopening window wells,or adjacent propertiesper Ordinance 40,2016. 11/27/17 Page: 34 File Name: 219 N Monarch Permit Set.pdf Subject: Fire Area Author: nickt Color: Provide a fire area floor plan measuring the fire area of the building. Fire area, as defined by 2015 IBC section 202, is measured to the inside of exterior walls but also includes exterior usable areas that are covered. Include the area under the trellis. Page: 35 File Name: 219 N Monarch Permit Set.pdf Subject: 75% high efficacy lamps Author: nickt Color: A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units. Note this requirement on the plans. (2015 IECC R404.1 & C405.1) Page: 41 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Provide a window and door schedule listing U factors, size, and which are safety glazed. The following windows must be safety glazed per 2015 IRC R308.4: 104, 105-109, 116, 148, 149, 201-205, 206-210, 224, and 225. Page: 43 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Window 224 will be unable to open due to the guard. Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: This callout references 8/7.4 which is a detail at the garage door. Create a detail for this condition showing the wall. E 2 G F 1 3 C5.3 TRELLIS BELOW LINE OF DECK BELOW LINE OF ROOF BELOW 4" HALF ROUNDCOPPER GUTTER TYP. PL SNOW CLIPS Provide a fire area floor plan measuring the fire area of the building. Fire area, as defined by 2015 IBC section 202, is measured to the inside of exterior walls but also includes exterior usable areas that are covered. Include the area under the trellis. RR R R R R R R G F WINE ROOM010 BATHROOM #1 013 X6.1 A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units. Note this requirement on theplans. (2015 IECC R404.1 & C405.1) DESIGN CO ALIU DESIGN CO ALIU CH STREET122'-0"ROOF VERTICAL T&G WOODSIDING WOOD FASCIA ROOF 217 215216 5 1432 Provide a window and door schedule listing U factors, size,and which are safety glazed. The following windows must besafety glazed per 2015 IRC R308.4:104, 105-109, 116, 148, 149, 201-205, 206-210, 224, and 225. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED SOUTH ELEVATION 4.3 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET 54 6 160 159 158 157 88'-10"LOWER LEVEL 88'-10"LOWER LEVEL 100'-0"MAIN LEVEL 100'-0"MAIN LEVEL 111'-0"UPPER LEVEL 111'-0"UPPER LEVEL 122'-0"ROOF 122'-0"ROOF VERTICAL T&G WOODSIDING WOOD FASCIA DRYSTACK STONEVENEER LINE OFFINISHED GRADE 229 228 226 150151 227 225 149 152 230231 224 153 154155156 222223 54 6 7213 0 2'4'8'SCALE: 1/4" = 1'-0"2 PARTIAL SOUTH ELEVATION 0 2'4'8'SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION Window 224 will beunable to open due tothe guard. 107.4 57.4 37.4 87.4 83'-4" 88'-10" 100'-0" ARCH = 7897 111'-0" GARAGE BEDROOM #4 UPPER FLOOR T.O. PLY MAIN FLOOR T.O. PLY LOWER LEVEL T.O. PLY CRAWL SPACE T.O. CONC. F4 F5 A SECTION 'A' This callout references8/7.4 which is a detailat the garage door.Create a detail for thiscondition showing thewall. 11/27/17 Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: You have two crawlspaces. The section drawings show the main crawl to appear to be within the thermal envelope but the vertical crawl that connects two stories appears to not be within the thermal envelope. REScheck shows the crawl as being not part of the thermal envelope. Pick an option below for each crawlspace and coordinate all drawings: a.If it will not be part of the thermal envelope, insulate the floor and walls between the crawl and living areas per 2015 IECC R401. Provide ventilation per 2015 IRC R408.2. Currently your mechanical plans show that you provide ventilation to the main crawlspace only. b.If the crawl is to be part of the thermal envelope, insulate the walls separating the crawl from the exterior per 2015 IECC R401. Provide conditioned air to the crawl per 2015 IRC R408.3 2.2 or ventilate per 2015 IRC R408.3 2.1 or 2015 IMC 406.1. Note: you must provide an air barrier at the thermal envelope per 2015 IECC table R402.4.1.1. Also, provide crawlspace access. Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Provide an air barrier at the separation between the garage and the rest of the house. 2015 IECC table R402.4.1.1 Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: This callout references 3/7.4 which is a detail at the foundation wall against grade. Create a detail for this condition showing the wall separating the two crawlspaces. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN , CO 219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SETCOPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED SECTIONS 5.1 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET 107.4 57.4 47.4 37.4 97.4 107.3 87.4 83'-4" 88'-10" 100'-0" ARCH = 7897 111'-0" LINE OF EXISTING GRADELINE OF PROPOSED GRADE GARAGE MUDROOM KITCHEN DINING ROOM POWDERROOM GUEST SUITEMASTER CLOSETMASTER BEDROOM GAME ROOMBEDROOM #4 HALL BEDROOM #3 UPPER FLOOR T.O. PLY MAIN FLOOR T.O. PLY LOWER LEVEL T.O. PLY CRAWL SPACE T.O. CONC. GUEST SUITECLOSET CRAWLSPACE AEDCBGF F5 F2F4 F2 F6 F3F5 02'4'8'SCALE: 1/4" = 1'-0"A SECTION 'A' You have two crawlspaces. The section drawings show the main crawl to appearto be within the thermal envelope but the vertical crawl that connects two storiesappears to not be within the thermal envelope. REScheck shows the crawl asbeing not part of the thermal envelope. Pick an option below for eachcrawlspace and coordinate all drawings: a.If it will not be part of the thermal envelope, insulate the floor and wallsbetween the crawl and living areas per 2015 IECC R401. Provide ventilation per2015 IRC R408.2. Currently your mechanical plans show that you provideventilation to the main crawlspace only.b.If the crawl is to be part of the thermal envelope, insulate the walls separatingthe crawl from the exterior per 2015 IECC R401. Provide conditioned air to thecrawl per 2015 IRC R408.3 2.2 or ventilate per 2015 IRC R408.3 2.1 or 2015IMC 406.1.Note: you must provide an air barrier at the thermal envelope per 2015 IECCtable R402.4.1.1.Also, provide crawlspace access. 107.4 57.4 47.4 37.4 107.3 87.4 83'-4" 88'-10" 100'-0" ARCH = 7897 111'-0" GARAGE MUDROOM KITCHEN DINING ROOM POWDERROOM GUEST SUITEMASTER CLOSETMASTER BEDROOM GAME ROOMBEDROOM #4 HALL BEDROOM #3 UPPER FLOOR T.O. PLY MAIN FLOOR T.O. PLY LOWER LEVEL T.O. PLY CRAWL SPACE T.O. CONC. GUEST SUITECLOSET CRAWLSPACE AEDCBGF F5 F2F4 F2 F6 F3F5 SCALE: 1/4" = 1'-0"A SECTION 'A' Provide an air barrierat the separationbetween the garageand the rest of thehouse. 2015 IECCtable R402.4.1.1 107.4 57.4 37.4 87.4 83'-4" 88'-10" 100'-0" ARCH = 7897 111'-0" GARAGE BEDROOM #4 UPPER FLOOR T.O. PLY MAIN FLOOR T.O. PLY LOWER LEVEL T.O. PLY CRAWL SPACE T.O. CONC. F4 F5 SCALE: 1/4" = 1'-0"A SECTION 'A' This callout references3/7.4 which is a detailat the foundation wallagainst grade. Createa detail for thiscondition showing thewall separating thetwo crawlspaces. 11/27/17 Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: Air sealing general note Author: nickt Color: Indicate in your sections and details how you will accomplish the air sealing requirements of 2015 IECC table R402.4.1.1. Indicate the continuity of the air barrier and where it is located throughout the building. Note locations that require caulking, sealing, taping, etc. Note which components are included in the air barrier such as spray foam, gypsum, housewrap, and/or exterior insulation. You may have all of the above but you need to pick one continuous barrier and stick to it. It needs to follow the thermal barrier. The better detail you provide, the easier it will be for the contractor and inspector to be successful. This is a new 2015 code requirement in lieu of a blower door test. Contact me to discuss. Page: 45 File Name: 219 N Monarch Permit Set.pdf Subject: Attic access Author: nickt Color: Provide access to all attics. Show hatches on RCPs. 2015 IRC R807 Page: 48 File Name: 219 N Monarch Permit Set.pdf Subject: Attic access Author: nickt Color: Provide access to all attics. Show hatches on RCPs. 2015 IRC R807 Page: 48 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Detail 9/7.4 does not appear on sheet 7.4. 107.4 57.4 87.4 100'-0" ARCH = 7897 111'-0" GARAGE UPPER FLOOR T.O. PLY MAIN FLOOR T.O. PLY G F F4 F5 Indicate in your sections and details how you willaccomplish the air sealing requirements of 2015 IECCtable R402.4.1.1. Indicate the continuity of the air barrier and where it is located throughout the building. Notelocations that require caulking, sealing, taping, etc. Notewhich components are included in the air barrier such asspray foam, gypsum, housewrap, and/or exteriorinsulation. You may have all of the above but you need topick one continuous barrier and stick to it. It needs tofollow the thermal barrier. The better detail you provide,the easier it will be for the contractor and inspector to besuccessful. This is a new 2015 code requirement in lieuof a blower door test. Contact me to discuss. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETISSUEDRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 57.4 47.4 97.4 107.3 LINE OF EXISTING GRADE LINE OF PROPOSED GRADE GARAGE MUDROOM KITCHEN DINING ROOM POWDERROOM GUEST SUITEMASTER CLOSETMASTER BEDROOM GAME ROOMBEDROOM #4 HALL BEDROOM #3 GUEST SUITECLOSET AEDCBF F5 F2F4 F2 F3F5 Provide access to allattics. Show hatcheson RCPs. 2015 IRCR807 567 4 2 13 97.4 137.3 97.3 77.3 117.3 88'-10" 100'-0"MAIN LEVEL 111'-0"UPPER LEVEL 122'-0"ROOF MASTER CLOSET LIVING ROOM DINING LIVINIG ROOMFITNESS STAIR MASTERFOYER F2 F7 F2 Provide access to allattics. Show hatcheson RCPs. 2015 IRCR807 97.4 7.3 LIVING ROOM FITNESS Detail 9/7.4 does notappear on sheet 7.4. 11/27/17 Page: 51 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Tyvek Thermawrap R5 is compressible- this means that when the wood siding is installed over it, it will be flattened and lose its R value. If you use furring strips, it will only be compressed at the strips- making it cavity insulation (not continuous). Revise details and/or REScheck to work together. (Also, won't you see the white tyvek through the 1/4" gaps in the siding?) Page: 51 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Your above grade exterior walls must have R-5 continuous insulation in addition to the cavity insulation to match your REScheck. Revise all details as necessary. Page: 51 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: REScheck shows basement walls with R-15 continuous insulation. Revise all drawings to match this or revise the REScheck. Page: 52 File Name: 219 N Monarch Permit Set.pdf Subject: Class A Roof Author: nickt Color: Provide documentation that the roof assemblies are Class A. This is typically either an ESR or UL report. Revise you roof details to match the reports. (Ordinance 40, 2016) Page: 53 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Include the wall separating the crawl from the living space in the REScheck. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 1 1/2"SEE PLAN 3 1/2"5/8" 1/2"5 1/2"5/8" 5/8"SEE PLAN5/8" 1/2" EXT. GRADE SHEATHING WALL FRAMING W/ BLOCKING AS REQUIRED R-28 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) TYVEK THERMAWRAP R-5 CONTINUOUSINSULATION VERTICAL WOOD SIDING @ 5" O.C. - LEAVE 1/4" GAP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE GROUT & JOINTS PER APPROVED MOCK-UP BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION FIBERGLASS FILTER CLOTH CONC. WALL RE: STRUCT. 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE FOUNDATION WATERPROOFING - CONTINUE TO BOTTOMOF FOOTING (SHOWN DASHED) 6" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7 R-13 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE GROUT & JOINTS PER APPROVED MOCK-UP WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7 MIN. 1" AIR OR MORTAR SPACE GROUT & JOINTS PER APPROVED MOCK-UP 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7 TYVEK THERMAWRAP R-5 CONTINUOUSINSULATION WALL DETAIL & ASSEMBLY TEMPLATE 1 ½" = 1'-0"INTERIOR WALL (TYPICAL)W1 1 ½" = 1'-0"W2 ½" = 1'-0"NSULATED FOUNDATION WALL W/ FURRING EXTERIOR STUD WALL W/ VERTICAL SIDING GL GL GL ½" = 1'-0" GL GL ½" = 1'-0"EXTERIOR STUD WALL W/ STONE VENEER @ STAIR GL WALL FRAMING W/ BLOCKING AS REQUIRED Tyvek Thermawrap R5 iscompressible- this means thatwhen the wood siding isinstalled over it, it will beflattened and lose its R value. Ifyou use furring strips, it will onlybe compressed at the strips-making it cavity insulation (notcontinuous). Revise detailsand/or REScheck to worktogether. (Also, won't you seethe white tyvek through the 1/4"gaps in the siding?) DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SETCOPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES 7.2 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET 1/2"5 1/2"5/8" 1 1/2"SEE PLAN3 1/2"5/8"3"1/2"5 1/2"3"5/8" 1/2"5 1/2"5/8" 5/8"SEE PLAN5/8" 2"SEE PLAN 1/2" EXT. GRADE SHEATHING WALL FRAMING W/ BLOCKING AS REQUIRED R-28 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) TYVEK THERMAWRAP R-5 CONTINUOUSINSULATIONVERTICAL WOOD SIDING @ 5" O.C. - LEAVE 1/4" GAP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE GROUT & JOINTS PER APPROVED MOCK-UP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER R-28 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION FIBERGLASS FILTER CLOTH CONC. WALL RE: STRUCT.5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE FOUNDATION WATERPROOFING - CONTINUE TO BOTTOMOF FOOTING (SHOWN DASHED) 6" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7MIN. 1" AIR OR MORTAR SPACE GROUT & JOINTS PER APPROVED MOCK-UP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER R-24 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7MIN. 1" AIR OR MORTAR SPACE 3" FURRING R-13 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE GROUT & JOINTS PER APPROVED MOCK-UP WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7MIN. 1" AIR OR MORTAR SPACE GROUT & JOINTS PER APPROVED MOCK-UP WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7MIN. 1" AIR OR MORTAR SPACE VERTICAL WOOD SIDING @ 5" O.C. - LEAVE 1/4" GAP FOUNDATION WATERPROOFINGCONTINUE TO BOTTOM OFFOOTING (SHOWN DASHED)4" DIAMETER A.B.S PERFORATEDFOUNDATION DRAIN FIBERGLASS FILTER CLOTHBACKFILL W/ SCREENED GRAVELR-11 RIGID INSULATION CONC. WALL RE: STRUCT.SLAB @ CRAWL SPACE RE: STRUCT. TYVEK THERMAWRAP R-5 CONTINUOUSINSULATION 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE 1 ½" = 1'-0"INTERIOR WALL (TYPICAL)W1 1 ½" = 1'-0"W3EXTERIOR STUD WALL W/ STONE VENEER 1 ½" = 1'-0"W2 1 ½" = 1'-0"INSULATED FOUNDATION WALL W/ FURRINGW4 EXTERIOR STUD WALL W/ VERTICAL SIDING GL GL GL 1 ½" = 1'-0"1 ½" = 1'-0"W7EXTERIOR STUD WALL W/ STONE VENEER @ STAIRS GL GL GL 1 ½" = 1'-0"W5EXTERIOR STUD WALL W/ STONE VENEER @ STAIR GL 1 ½" = 1'-0"W6EXTERIOR STUD WALL W/ STONE VENEER @ DECK 1TYPICAL FOOTER CONDITION1 ½" = 1'-0" GL WALL FRAMING W/ BLOCKING AS REQUIRED Your above gradeexterior walls musthave R-5 continuousinsulation in addition tothe cavity insulation tomatch your REScheck.Revise all details asnecessary. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETISSUEDRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 1 1/2"SEE PLAN 3 1/2"5/8"3"1/2"5 1/2"3"5/8" 1/2"5 1/2"5/8" 5/8"SEE PLAN5/8" 2"SEE PLAN 1/2" EXT. GRADE SHEATHING WALL FRAMING W/ BLOCKING AS REQUIRED R-28 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) TYVEK THERMAWRAP R-5 CONTINUOUSINSULATION VERTICAL WOOD SIDING @ 5" O.C. - LEAVE 1/4" GAP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION FIBERGLASS FILTER CLOTH CONC. WALL RE: STRUCT. 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE FOUNDATION WATERPROOFING - CONTINUE TO BOTTOMOF FOOTING (SHOWN DASHED)GROUT & JOINTS PER APPROVED MOCK-UP 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHING BUILDING WRAP/ PAPER R-24 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7 MIN. 1" AIR OR MORTAR SPACE 3" FURRING R-13 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS ASVAPOR BARRIER) 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH -SEE SCHEDULE GROUT & JOINTS PER APPROVED MOCK-UP WALL FRAMING W/BLOCKING AS REQUIRED 1/2" EXT. GRADE SHEATHINGBUILDING WRAP/ PAPER 3" (NOMINAL) STONE VENEER MTL. WALL TIES PER I.R.C. CHAPTER 7 MIN. 1" AIR OR MORTAR SPACE FOUNDATION WATERPROOFINGCONTINUE TO BOTTOM OFFOOTING (SHOWN DASHED)4" DIAMETER A.B.S PERFORATEDFOUNDATION DRAIN FIBERGLASS FILTER CLOTH BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION CONC. WALL RE: STRUCT. SLAB @ CRAWL SPACE RE: STRUCT. 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE 1 ½" = 1'-0"INTERIOR WALL (TYPICAL)W1 1 ½" = 1'-0"W2 1 ½" = 1'-0"INSULATED FOUNDATION WALL W/ FURRINGW4 EXTERIOR STUD WALL W/ VERTICAL SIDING GL GL GL 1 ½" = 1'-0"1 ½" = 1'-0"W7 EXTERIOR STUD WALL W/ STONE VENEER @ STAIRS GL GL GL 1 ½" = 1'-0"W5EXTERIOR STUD WALL W/ STONE VENEER @ STAIR GL 1 TYPICAL FOOTER CONDITION1 ½" = 1'-0" GL WALL FRAMING W/ BLOCKING AS REQUIRED REScheck showsbasement walls withR-15 continuousinsulation. Revise alldrawings to match thisor revise theREScheck. DES A DR COP COR RO SC SC RD PE SEE INTERIOR SPECIFICATIONS FORFINISH MATERIAL 5/8" C/DX PLYWOOD SHEATHING SYNTHETIC SHINGLES 5/8" GYP. BD. CEILING - TYP OVERHEATED SPACES VAPOR BARRIER ATATTICE SPACE ONLY 8" R7/INCH BLOWN-IN POLY-ISO INSULATION(R-56 TOTAL) RAFTER RE:STRUCTURAL BITUMINOUS WATERPROOFMEMBRANE (FULL COVERAGE)- HIGH TEMPERATURE TYPICAL FLAT MEMBRANE ROOFR11 ½" = 1'-0" 1 ½" = 1'-0"R2 TYPICAL ROOF W/ SHINGLES Provide documentation that the roofassemblies are Class A. This is typically either an ESR or UL report. Revise you roof details to match the reports.(Ordinance 40, 2016) DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES &DETAILS 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 2 63/64"SEE PLAN 2 63/64" 2"SEE PLAN3 1/2"5/8" 5 1/2"5/8" 5/8" GYPSUM WALL BOARD OR OTHERINTERIOR FINISH - SEE SCHEDULE WALL FRAMING W/ BLOCKING ASREQUIRED R-28 SPRAY-IN RIGID CLOSED-CELLINSULATION (ACTS AS VAPOR BARRIER) CONC. WALL RE: STRUCT. MTL. WALL TIES @ (1)PER 2 SQ. FT. MAX. -NON-CORRUGATED GROUT & JOINTS PER APPROVED MOCK-UP 3" (NOMINAL) STONE VENEER FOUNDATIONWATERPROOFINGCONTINUE TO BOTTOMOF FOOTING (SHOWNDASHED)4" DIAMETER A.B.SPERFORATEDFOUNDATION DRAIN FIBERGLASS FILTER CLOTH BACKFILL W/ SCREENEDGRAVEL R-11 RIGID INSULATION WALL FRAMING W/BLOCKING AS REQUIRED CONC. WALL RE:STRUCT. 5/8" GYPSUM WALL BOARDOROTHER INTERIOR FINISH -SEE SCHEDULE SEE PLAN FOR FLOORING TYPE GRADE PER LANDSCAPE PLAN .3 1 ½" = 1'-0"INTERIOR WALL @ CRAWLSPACEW13 1 ½" = 1'-0"W14RETAINING WALL W/ STONE VENEER 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE GL GL 7 TYPICAL FOOTER CONDITION1 ½" = 1'-0" GL LIVING SPACECRAWLSPACE Include the wallseparating the crawlfrom the living spacein the REScheck. 11/27/17 Page: 53 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Details 1/7.2 and 7/7.4 show the same footer condition differently. One shows what appears to be an insulated crawl, another a non-insulated crawl. Coordinate your drawings. Page: 54 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Revise stone veneer details to provide weeps per 2015 IRC R703.8.5. Page: 54 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: The roof plan suggests the roof deck is sloped to a central drain. How is the slope provided? Revise 4/A7.4 to provide greater detail on waterproofing and drainage. Page: 55 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: Window details on 7.5 reference stucco that is not shown anywhere else. If there is to be stucco on this project, revise elevations, wall sections, and details. Label if it is EIFS or cementitious. If using EIFS, provide a drainage plane or it will require special inspection (2015 IBC 1704). If no stucco, update your window details. Page: 72 File Name: 219 N Monarch Permit Set.pdf Subject: PlanCheck Author: nickt Color: The following windows must be safety glazed per 2015 IRC R308.4. Revise the window schedule on 10.1. 104, 105-109, 116, 148, 149, 201-210, 224, 225. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES &DETAILS 7.4 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET 2 63/64"SEE PLAN 2 63/64" 2"SEE PLAN3 1/2"5/8" 5 1/2"5/8" 5/8" GYPSUM WALL BOARD OR OTHERINTERIOR FINISH - SEE SCHEDULE WALL FRAMING W/ BLOCKING ASREQUIRED R-28 SPRAY-IN RIGID CLOSED-CELLINSULATION (ACTS AS VAPOR BARRIER) CONC. WALL RE: STRUCT. MTL. WALL TIES @ (1)PER 2 SQ. FT. MAX. -NON-CORRUGATED GROUT & JOINTS PER APPROVED MOCK-UP 3" (NOMINAL) STONE VENEER FOUNDATIONWATERPROOFINGCONTINUE TO BOTTOMOF FOOTING (SHOWNDASHED)4" DIAMETER A.B.SPERFORATEDFOUNDATION DRAIN FIBERGLASS FILTER CLOTH BACKFILL W/ SCREENEDGRAVEL R-11 RIGID INSULATION WALL FRAMING W/BLOCKING AS REQUIRED CONC. WALL RE:STRUCT. 5/8" GYPSUM WALL BOARDOROTHER INTERIOR FINISH -SEE SCHEDULE SEE PLAN FOR FLOORING TYPE GRADE PER LANDSCAPE PLAN 7.3 1 ½" = 1'-0"INTERIOR WALL @ CRAWLSPACEW13 1 ½" = 1'-0"W14RETAINING WALL W/ STONE VENEER 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE GL GL 7TYPICAL FOOTER CONDITION1 ½" = 1'-0" GL LIVING SPACECRAWLSPACE Details 1/7.2 and 7/7.4 show thesame footer condition differently.One shows what appears to be aninsulated crawl, another anon-insulated crawl. Coordinateyour drawings. 2"SEE P FOUNDATION WATERPROOFINGCONTINUE TO BOTTOM OFFOOTING (SHOWN DASHED) 4" DIAMETER A.B.S PERFORATEDFOUNDATION DRAIN FINISH GRADE SLOPE AWAY WATERPROOFING WRAPPEDUNDER CAP STONE(SHOWN DASHED) MTL. WALL TIES @ (1) PER 2SQ. FT. MAX. - NON-CORRUGATED 3" (NOMINAL) STONEVENEER METAL DRIP GROUT & JOINTS PERAPPROVED MOCK-UP WATERPROOFINGSHEATHING METAL DRIP 7.4 7 TYPICAL FOOTER CON 1 ½" = 1'-0" GL GL PLANTER DETAIL101 ½" = 1'-0" 3/4" PLYWOOD Revise stone veneer details to provide weeps per 2015 IRCR703.8.5. 2"SEE PLAN 3 1/2"5/8" FOUNDATION WATERPROOFINGCONTINUE TO BOTTOM OFFOOTING (SHOWN DASHED) 4" DIAMETER A.B.S PERFORATEDFOUNDATION DRAIN FIBERGLASS FILTER CLOTH BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION WALL FRAMING W/BLOCKING AS REQUIRED CONC. WALL RE: STRUCT. 5/8" GYPSUM WALL BOARD OROTHER INTERIOR FINISH -SEE SCHEDULE SEE PLAN FOR FLOORING TYPE SHEATHINGWATERPROOFING METAL DRIP MTL. WALL TIES @ (1) PER 2SQ. FT. MAX. - NON-CORRUGATED GROUT & JOINTS PERAPPROVED MOCK-UP 3" (NOMINAL) STONEVENEER HSS UNDER STONE; SEE STRUCTURAL FOR SIZE STEEL BEAM, PACK OUT AS REQD; SEESTRUCTURAL 3/4" PLYWOOD STEEL BEAM, PACK OUT AS REQD; SEESTRUCTURAL 3/4" PLYWOOD CONC SLAB; SEE STRUCTURAL 14" WOOD JOIST; SEESTRUCTURAL 5/8" GYPSUM WALL BOARD;SEE SCHEDULE FOUNDATION WATERPROOFINGCONTINUE TO BOTTOM OFFOOTING BACKFILL W/ SCREENED GRAVEL R-11 RIGID INSULATION WALL FRAMING W/BLOCKING AS REQUIRED CONC. WALL RE: STRUCT. 5/8" GYPSUM WALL BOARD,SEE SCHEDULE METAL DRIP DECKING WATERPROOFING HSS UNDER STONE; SEESTRUCTURAL FOR SIZE WRAP WATERPROOFING AT STEELHSS WATERPROOFINGSHEATHING MTL. WALL TIES @ (1) PER 2 SQ.FT. MAX. - NON-CORRUGATED 3" (NOMINAL) STONE VENEER METAL DRIP SIMPSON MTL HANGE STEEL BEAM, PACK O STRUCTURAL 6" SOUND- FINISH GRADE SLOPE AWAY CONCRETE TOPPING CONCRETE DECKING CONCRETE STONE AT P 3/4" PLYWO WATERPRO .4 1 1/2" WALL DETAIL & ASSEMBLY TE 7 TYPICAL FOOTER CONDITION1 ½" = 1'-0" GL T. O. PLYWOOD100'-0"T. O. SLAB99'-7" T. O. STRUCTURE99'-2" DECK TRANSITION DETAIL41 ½" = 1'-0" GARAGE ENTRY DECK MASTER PATIO TRANSITION DETAIL11 ½" = 1'-0" GL T. O. PLYWOOD111'-0" T. O. PLYWOOD110'-10" EXTERIOR LIVING ROOM T. O. 99'-4 14" WOOD JOIST; SEESTRUCTURAL 14" WOOD JOIST; SEE The roof plansuggests the roof deckis sloped to a centraldrain. How is the slopeprovided? Revise4/A7.4 to providegreater detail onwaterproofing anddrainage. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SETCOPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED WINDOW DETAILS 7.5 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET 1 1/4" 1 1/4"3 49/64"3 3/4" 3 3/4" WINDOW TRIM WOOD TRIM PER INTERIORSPECIFICATIONS WINDOW TRIM JAMB EXTENSION WOOD CASING PERINTERIOR SPECIFICATIONS WOOD CASING PERINTERIOR SPECIFICATIONS WOOD TRIM PER INTERIORSPECIFICATIONS JAMB EXTENSION WOOD CASING PERINTERIOR SPECIFICATIONS WOOD CASING PERINTERIOR SPECIFICATIONS WINDOW HEAD FLASHING- INSTALL PER STUCCOMANUFACTURER'SSPECIFICATIONS EXPANDED FLANGECASING BEADBACKER ROD & SEALANT LAHABRA BRAND STUCCOINSTALLED PER SPECS-SANTA BARBARA FINISHCOAT -COLOR TBD SILL PAN LAHABRA BRAND STUCCOINSTALLED PER SPECS-SANTA BARBARA FINISHCOAT -COLOR TBD EXPANDED FLANGECASING BEADBACKER ROD & SEALANT STONE SILL WOOD TRIM PER INTERIORSPECIFICATIONS JAMB EXTENSION WOOD CASING PERINTERIOR SPECIFICATIONS WOOD CASING PERINTERIOR SPECIFICATIONS STEEL C-CHANNEL HEADER BACKER ROD & SEALANT HEAD FLASHING BACKER ROD & SEALANT BACKER ROD & SEALANT BACKER ROD & SEALANT WINDOW HEAD FLASHINGSEALANT SEALANT SEALANT 7.5 13" = 1'-0" 3" = 1'-0"2 3" = 1'-0"3 WINDOW HEAD @ HORIZONTAL WOOD SIDING WINDOW JAMB @ HORIZONTAL WOOD SIDING WINDOW SILL @ HORIZONTAL WOOD SIDING GL GL GL 3" WINDOW TEMPLATE 43" = 1'-0" 3" = 1'-0"5 3" = 1'-0"6 WINDOW HEAD @ STUCCO WINDOW JAMB @ STUCCO WINDOW SILL @ STUCCO GL GL GL 73" = 1'-0" 3" = 1'-0"8 3" = 1'-0"9 WINDOW HEAD @ STONE WINDOW JAMB @ STONE WINDOW SILL @ STONE GL GL GL Window details on 7.5reference stucco thatis not shownanywhere else. If thereis to be stucco on thisproject, reviseelevations, wallsections, and details.Label if it is EIFS orcementitious. If usingEIFS, provide adrainage plane or itwill require specialinspection (2015 IBC1704). If no stucco,update your windowdetails. DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SETCOPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED DOOR & WINDOWSCHEDULES 10.1 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET WIDTHHEIGHTSILL HEIGHT001CASEMENT3'-0"4'-0"36"12 EGRESS002CASEMENT3'-0"4'-0"36"12 EGRESS003CASEMENT3'-0"4'-0"36"12 EGRESS004CASEMENT3'-0"4'-0"36"12 EGRESS005CASEMENT3'-0"4'-0"36"12 EGRESS101CASEMENT3'-0"6'-0"102CASEMENT 3'-0"6'-0"103CASEMENT 3'-0"6'-0"104CASEMENT 3'-0"4'-0"105FIXED 3'-0"6'-0"TEMPERED GLASS106FIXED3'-0"6'-0"TEMPERED GLASS107FIXED3'-0"6'-0"TEMPERED GLASS108FIXED3'-0"6'-0"TEMPERED GLASS109FIXED3'-0"6'-0"TEMPERED GLASS110CASEMENT3'-0"6'-0"111CASEMENT 3'-0"6'-0"112CASEMENT 3'-0"6'-0"113CASEMENT 3'-0"6'-0"114CASEMENT 3'-0"6'-0"115CASEMENT 3'-0"2'-6"5'-5 1/4"116FIXED 2'-0"8'-2 1/4"4"117AWNING 3'-0"2'-0"118AWNING 3'-0"2'-0"119CASEMENT 3'-0"6'-0"120CASEMENT 3'-0"6'-0"121FIXED 3'-0"2'-0"122FIXED 3'-0"2'-0"123AWNING 3'-0"2'-0"124AWNING 3'-0"6'-0"125CASEMENT 3'-0"6'-0"126CASEMENT 3'-0"2'-0"127FIXED 3'-0"2'-0"128FIXED 3'-0"2'-0"129CASEMENT 3'-0"6'-0"130AWNING 3'-0"2'-0"131AWNING 3'-0"2'-0"132CASEMENT 3'-0"6'-0"133CASEMENT 3'-0"6'-0"134FIXED 3'-0"2'-0"135FIXED 3'-0"2'-0"136AWNING 3'-0"2'-0"137AWNING 3'-0"2'-0"138CASEMENT 3'-0"6'-0"139CASEMENT 3'-0"6'-0"140FIXED 3'-0"2'-0"141FIXED 3'-0"2'-0"142FIXED 3'-0"6'-0"143FIXED 3'-0"6'-0"144FIXED 3'-0"6'-0"145FIXED 3'-0"6'-0"146FIXED 3'-0"6'-0"147FIXED 3'-0"6'-0"148CASEMENT 3'-0"6'-0"149FIXED 3'-0"6'-0"150FIXED 3'-0"4'-0"151FIXED 3'-0"4'-0"152FIXED 3'-0"4'-0"153FIXED 3'-0"2'-8"154FIXED 3'-0"2'-8"155FIXED 3'-0"4'-0"156FIXED 3'-0"4'-0"157FIXED 3'-0"4'-0"158FIXED 3'-0"4'-0" WINDOW SCHEDULEIDAREASIZE COMMENTSSTYLE 201FIXED 3'-0"6'-0"202FIXED 3'-0"6'-0"203FIXED 3'-0"6'-0"204FIXED 3'-0"6'-0"205FIXED 3'-0"6'-0"206FIXED 3'-0"6'-0"207FIXED 3'-0"6'-0"208FIXED 3'-0"6'-0"209FIXED 3'-0"6'-0"210FIXED 3'-0"6'-0"211CASEMENT 3'-0"6'-0"212CASEMENT 3'-0"6'-0"213CASEMENT 3'-0"6'-0"214CASEMENT 3'-0"2'-0"215FIXED 3'-0"2'-0"216FIXED 3'-0"2'-0"217FIXED 3'-0"2'-0"218CASEMENT 3'-0"6'-0"219CASEMENT 3'-0"6'-0"220CASEMENT 3'-0"6'-0"221FIXED 3'-0"6'-0"222FIXED 3'-0"6'-0"223CASEMENT 3'-0"6'-0"224CASEMENT 3'-0"6'-0"225CASEMENT 3'-0"6'-0"226FIXED 3'-0"2'-0"227FIXED 3'-0"2'-0"228FIXED 3'-0"2'-0"229FIXED 3'-0"2'-0"230CASEMENT 3'-0"6'-0"231CASEMENT 3'-0"6'-0" WIDTHHEIGHTLOWER LEVEL0012'-8"8'-0"WOODLOWER LEVEL0023'-0"8'-0"WOODLOWER LEVEL002a2'-10"8'-0"GLASS SAPHIRE GLASS SHOWER DOORLOWER LEVEL0035'-0"8'-0"WOOD DOUBLE POCKET DOORLOWER LEVEL0042'-8"8'-0"LOWER LEVEL0052'-8"8'-0"LOWER LEVEL005a2'-10"8'-0"GLASS SAPHIRE GLASS SHOWER DOORLOWER LEVEL0072'-8"8'-0"LOWER LEVEL007a5'-8"8'-0"DOUBLE SWING DOORLOWER LEVEL0082'-8"8'-0"LOWER LEVEL008a2'-10"8'-0"GLASS SAPHIRE GLASS SHOWER DOORLOWER LEVEL0092'-8"8'-0"MAIN LEVEL1012'-6"6'-8"MAIN LEVEL101a8'-0"8'-0"MAIN LEVEL101b8'-0"8'-0"MAIN LEVEL1025'-0"8'-0"DOUBLE SWING DOORMAIN LEVEL1065'-9 1/2"7'-8 3/4"MAIN LEVEL106a5'-9 1/2"7'-8 3/4"MAIN LEVEL1073'-0"8'-0"MAIN LEVEL107a2'-10"8'-0"DOUBLE SWING DOORMAIN LEVEL107b5'-0"8'-0"DOUBLE SWING DOORMAIN LEVEL1082'-6"8'-0"WOOD POCKETMAIN LEVEL108a4'-10"8'-0"WOOD POCKETMAIN LEVEL108b3'-0"8'-0"GLASS SAPHIRE GLASS SHOWER DOORMAIN LEVEL1093'-0"8'-0"METAL/GLASS EXTERIOR DOORUPPER LEVEL2013'-0"8'-0"METAL/GLASS EXTERIOR DOORUPPER LEVEL201a2'-8"8'-0"UPPER LEVEL2022'-10"8'-0"UPPER LEVEL202a2'-10"8'-0"GLASS SAPHIRE GLASS SHOWER DOORUPPER LEVEL2033'-0"8'-0"UPPER LEVEL2043'-0"8'-0"UPPER LEVEL2053'-0"8'-0"UPPER LEVEL205a5'-0"8'-0"UPPER LEVEL2062'-10"8'-0"UPPER LEVEL206a2'-8"8'-0"UPPER LEVEL206b2'-6"8'-0"GLASS SAPHIRE GLASS SHOWER DOOR ID MATERIALSIZE COMMENTSDOOR SCHEDULEFLOOR The following windowsmust be safety glazedper 2015 IRC R308.4.Revise the windowschedule on 10.1.104, 105-109, 116,148, 149, 201-210,224, 225. 11/27/17