Loading...
HomeMy WebLinkAboutFile Documents.219 N Monarch St.0179.2017 (4).ARBKDEW POINT CALCULATION JOB NAME: 219 N Monarch JOB NUMBER: 17042 DATE: 7/21/17 CALCS BY: JCB DP @ DP @ DP @ DP @ DP @ 20% RH 25% RH 30% RH 35% RH 45% RH 30 33 37 41 48 -20 Indoor design temperature (IDT)70 90 R-value 0.17 0.00 0.00 0.94 50.00 0.00 0.56 0.61 52.28 1.17 68 41 YES Note: To minimize the potential for condensation problems, humidity levels within the home must be properly controlled and adjusted based on outdoor temperatures. Is TA warmer than the DPA? Inside air layer R-Total R-value at A A: point of condensation analysis Vapor barrier 5/8" gypboard TA = IDT - (R-value at A)/(R-Total) * (Delta T) TA = Temperature at point A DPA = Dew point at point A (35% RH) Roof Underlayment 3/4" plywood 8" spray foam insulation (R-6.25/in) Outdoor design temperature (ODT) Delta T = IDT - ODT Layer Thermal Resistance of Proposed Roof Assembly Outside air layer Roofing 7/21/17