Loading...
HomeMy WebLinkAboutFile Documents.219 N Monarch St.0179.2017 (32).ARBK0179.2017.ARBK_Zoning_1 Page: 1 Checkmark: Unchecked Author: jimp File Name: 2171613 ISP-TOPO 24X36 04-18-17 (1).pdf 24.2 ft 2171613 ISP-TOPO 24X36 04-18-17 (1).pdf (2) Page: 1 Checkmark: Unchecked Author: jimp File Name: 2171613 ISP-TOPO 24X36 04-18-17 (1).pdf 16.3 ft Page: 1 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please provide an exterior lighting plan with cut sheets and pictures of the proposed lighting fixtures. 219 N Monarch Permit Set.pdf (29) Page: 1 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please provide an architectural site plan showing setbacks and details on all items within the yards. Page: 1 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Need a zoning compliance policy form signed by contractor Page: 3 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Should be 30.12 Page: 3 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Amend to be compliant 24.2 f t 16.3 ftPlease provide an exterior lighting plan with cut sheets and pictures of the proposedlighting fixtures. Please provide an architectural site plan showing setbacks and details on all items within the yards. Need a zoning compliance policy form signed by contractor (Principal)(Accessor 10 10 20 10 10 30 5 Yes Required N/A Not req'd for residential Should be 30.12 15 10.115 5 10.119 20 20.234 10 17.033 10 12.99 30 30.023 5 N/A Proposed Amend to be compliant EXTERIOR LIGHTING SHOWN ON ELECTRICAL PLANS; CUT SHEET PROVIDED SETBACKS AND SITE INFO SHOWN ON SHEET 2.1 PROVIDED TO REMAIN 30 BASED ON CONVERSATION WITH JIM P. SEE COMMENT ABOVE 11/27/17 Page: 3 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please provide your allowable FA - 3,661 Page: 4 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf In order to receive credit for any of this square footage, please provide full shaded FA diagrams and chart for the existing space. Page: 5 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please provide a scale for all drawings. Page: 5 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Since this wall is one side of the window well, a portion of it would be exposed. Revise. Page: 5 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Revise all of these sub-grade walls to meet the requirements for calculating sub-grade FA in 26.575.020.D.8. Sub-grade walls should only represent the interior dimensions of the walls on that level. Therefore, most of these walls are approximately 9'11" in height based on the sections. Once the walls have been revised, revise your area calculations, your percent, and the subsequent exposed FA for this level. Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf If this is an outdoor fireplace or grill, it must be compliant with 26.575.020.E.5.m), allowed projections into setbacks. Per the diagram in the section, this area would not be available to place one of these features in. Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf 2'-6 5/32" 902 etween 9,000 sq ft + ; 3,660 sq ft onal 100 sq ft in Net Lot Area, area or area persuant to TDR receivership Please provide your allowable FA - 3,661 DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED EXISTING BUILDINGFLOOR AREA 1.4 04/17/2017SCHEMATIC I SET05/09/2017SCHEMATIC II SET05/15/2017RDS06/28/2017PERMIT SET SCALE: 1:31219 N.Monarch - UPPER LEVEL SCALE: 1:31219 N.Monarch - MAIN LEVEL In order to receivecredit for any of thissquare footage,please provide fullshaded FA diagramsand chart for theexisting space. DESIGN COR ALIUS DESIGN COR ALIUS ASPEN, CO219 MONARCH STREETIS PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED LOWER LEVEL FLOO AREA 1.5 04/1 SCHEMATIC I SET 05/0 SCHEMATIC II SET 05/1 RDS 06/2 PERMIT SET 357 sq ft 63 sq ft 174 sq ft 27 sq ft 552 sq ft 174 sq ft 28 sq ft 298 sq ft 34 sq ft 518 sq ft 413 sq ft 538 sq ft 26 sq ft 389 sq ft 538 sq ft 26 sq ft 48 sq ft 327 sq ft 63 sq ft 22'-6 1/2"3'-11 1/2"34'-10 1/2"10'-11 1/2"18'-10"32'-8 1/2"26'-1"34'-0"24'-7"23'-6"3'-0 1/2"20'-8"3'-11 1/2"22'-6 1/2"15'-10"15'-10"3'-11 1/2" 10'-11 1/2"15'-10"10'-11 1/2"15'-10"34'-10 1/2"15'-10"10'-11 1/2"15'-10"18'-10" 3'-10"7'-0"4'-0"7'-0"7'-0"4'-10"15'-10"32'-8 1/2"15'-10"26'-1"15'-10"34'-0" 3'-8"7'-0"15'-10"24'-7"15'-10"34'-0" 3'-8"7'-0"15'-10"3'-0 1/2"15'-10"20'-8"15'-10"3'-11 1/2" WALL #001 WALL #002 WALL #003 WALL #004 WALL #005 WALL #006 WALL #007 WALL #008 WALL #009 WALL #010 WALL #011 WALL #012 WALL #013 WALL #014 WALL #001 WALL #002 WALL #003 WALL #004 WALL #005 WALL #006 WALL #007 WALL #008 WALL #009 WALL #010 WALL #011 WALL #012 WALL #013 WALL #014 3,371 sq ft Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft)1 357.00 0.00263.00 0.003174.00 27.004552.00 0.005174.00 28.006298.00 34.007518.00 0.008413.00 0.009538.00 26.0010389.00 0.0011538.00 26.001248.00 0.0013327.00 0.001463.00 0.00q Ft)4,452.00 141.00d / Total)3.17% ea (Sq Ft)3371.00or Area (Sq Ft)106.86 (3371*.0317)e Floor Area (Sq Ft)106.86 Ft)106.86Ft)2469.00Ft)0.00 Ft)1239.00(Sq Ft)3,814.86 sEET l Calculations or Area Calculations Calculations Please provide ascale for all drawings.24'-7"'-6 1/2"15'-1 15'-10"3'-11 1/2" WALL #009 WALL #010 WALL #001 Since this wall is one side of the window well, a portion of it would be exposed. Revise. 357 sq ft Revise all of these sub-grade walls to meet the requirements for calculating sub-grade FA in 26.575.020.D.8. Sub-grade walls should only represent the interior dimensions of the walls on that level. Therefore, most of these walls are approximately 9'11" in height based on the sections. Once the walls have been revised, revise your area calculations, your percent, and the subsequent exposed FA for this level. LINE OF SETBACK 2,246 sq ft If this is an outdoor fireplace or grill, it must be compliant with 26.575.020.E.5.m), allowed projections into setbacks. Per the diagram in the section, this area would not be available to place one of these features in. 2'-6 5/32" PROVIDED IN UPDATED ZONING SUMMARY SHEET 1.3 SHADED FLOOR AREA DIAGRAMS AND CHART SHOWN ON SHEET 1.4 SCALE SHOWN ALL DRAWINGS AND CALCS REVISED ACCORDINGLY REVISED ACCORDINGLY BASED ON CONVERSATION AND CLARIFICATION WITH JIM P. INCLUDED BASED ON COVERSATION WITH JIM P. ALL CALCS AND DRAWINGS REVISED ACCORDINGLY. NO COMMENT/STAIRS ALLIGNED; COORDINATED WITH JIM P. 11/27/17 Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf 1'-11 17/32" Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please add grid lines and a scale to the FA drawings Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf The length of the staircase on these two drawings does not match. Please make sure that they do match, and that the deck square footage is the entire staircase. Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Maximum FA is 3,661 sq ft. Revise. Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Note that per 26.575.020.D.4, Decks, deck area includes railings. Please make sure all railings on the stairs and deck are included in your deck calculations. Page: 6 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Looking at the structural drawings, this space is accessible. Please add it to your FA total. Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Height over topography is supposed to be an absolute point in space that is not dependent on grade. Therefore on a symmetrical gable, such as the one on this house, that absolute hight point should be identical on both sides. Revise. 1'-11 17/32" DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED MAIN & UPPER LEVELFLOOR AREA 1.6 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 30 sq ft UP LINE OF SETBACK 2,246 sq ft 250 sq ft exempt 348 sq ft: count half of 250 plus remainder (125+98) FRONT PORCH EXEMPTFROM DECK CALCULATION 539 sq ft DN LINE OF SETBACK 1,239 sq ft PLANTER 30' ABOVEDECK HEIGHT NOT INCLUDEDIN CALCULATION evel Gross Floor Area (Sq Ft)2246ge Gross Floor Area (Sq Ft)598arage Floor Area (Sq Ft)223 Calculated per table26.575.020-2e Floor Area (Sq Ft)2469.00 oor Area (Sq Ft)30.00 Exempt per 26.575.020.D5a (Sq Ft)0.00r Area (Sq Ft)0.00rea (Sq Ft)549.00 (3,660 allowable x 15%)le Floor Area (Sq Ft)0.00 (0<549 EXEMPT) r Area Calcuationsea (Sq Ft)106.86a (Sq Ft)2469.00ea (Sq Ft)0.00ea (Sq Ft)1239.00Area (Sq Ft)3,814.86 ations STREETl Floor Area Calculations h Floor Area Calculations evel Gross Floor Area (Sq Ft)1239ble Floor Area (Sq Ft)1239.00 oor Area (Sq Ft)30.00 Exempt per 26.575.020.D5a (Sq Ft)539.00r Area (Sq Ft)0.00rea (Sq Ft)549.00 (3,660 allowable x 15%)le Floor Area (Sq Ft)0.00 (539<549 EXEMPT) r Area Calcuationsea (Sq Ft)106.86a (Sq Ft)2469.00ea (Sq Ft)0.00ea (Sq Ft)1239.00Area (Sq Ft)3,814.86 ations STREETel Floor Area Calculations h Floor Area Calculations LEVEL FLOOR AREA R FLOOR AREA CALC Please add grid linesand a scale to the FAdrawings 539 sq ft The length of the staircase on these two drawings does not match. Please make sure that they do match, and that the deck square footage is the entire staircase. 2469.00 0.00 1239.00 3,814.86 Maximum FA is 3,661 sq ft. Revise. 539 sq ft LINE OF SETBACK PLANTER 30' ABOVEDECK HEIGHT NOT INCLUDED IN CALCULATION Note that per26.575.020.D.4, Decks, deck areaincludes railings. Please make sure allrailings on the stairs and deck are includedin your deckcalculations. LINE OF SETBACK exempt (125+98) Looking at the structural drawings, this space is accessible. Please add it to your FA total. Existing 7920.75 24'-9 3/8" Existing 7920.5 24'-6 3/8"Existing 7911 14'-7 1/2" Existing 7912.95 16'-5 1/16"Existing 7914 17'-6" Proposed 7918.8 22'-4" Proposed 7910.65 13'-10" Existing 7906.5 10'-6" Most Restrictive Roof Height Over Topography Actual Roof Height Over Most Restrictive ELEVATION POINT #008 EXEMPT DORMER PER26.575.20 F 2.(g) 7896 Height overtopography issupposed to be an absolute point inspace that is notdependent on grade. Therefore on asymmetrical gable,such as the one on this house, thatabsolute hight pointshould be identical on both sides. Revise. NO COMMENT/STAIRS ALLIGNED; COORDINATED WITH JIM P. SCALE AND GRIDS PROVIDED ALLIGNED FAR REVISED BASED ON ALL FAR COMMENTS REVISED AND INCLUDED ON ALL FAR SHEETS AND CALCS REVISED ITS NOT COUNTED TOWARD FAR; HAS LID NO GREATER THAN 5'-6" 11/27/17 Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf 16'-4 7/32" Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please add pitches to these roof planes. Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Please move this point to the most restrictive point across the top of the trellis based on grade. Per the survey, the most restrictive is the SW corner of the trellis. Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Height over topography is supposed to be an absolute point in space that is not dependent on grade. Therefore on a symmetrical gable such as the one on this house, that absolute hight point should be identical on both sides. Revise. Page: 8 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf 24'-1 29/32" Page: 41 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf Add to all elevations the following items: 1) A maximum height line that matches the most restrictive grade across the elevation. 2) Height points that correspond to the height points shown on the Height Over Topography sheet. 3) A clearly labeled Finished Grade line. 4) A clearly labeled Natural Grade line. Page: 45 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf 8'-4 5/32" 16'-4 7/32" 7920.75 24'-9 3/8"7920.5 24'-6 3/8"7911 14'-7 1/2"7912.95 16'-5 1/16"7914 17'-6"7918.8 22'-4" 7910.65 13'-10"7906.5 10'-6" ELEVATION POINT #001 LINE OFMEASUREMENT; TYP. ELEVATION POINT #002 ELEVATION POINT #003 ELEVATION POINT #006 POINT #007 ELEVATION POINT #008 EXEMPT DORMER PER26.575.20 F 2.(g) 7896 7896 7896 ON GRADEPATIO ON GRADEPATIO DECK Please add pitches tothese roof planes. ELEVATION POINT #006ELEVATION POINT #007 7896 7897 Please move this point to the most restrictive point across the top of the trellis based on grade. Per the survey, the most restrictive is the SW corner of the trellis. PROPERTY LINELINE OF NEW GRADE ELEVATION POINT #001 LINE OFMEASUREMENT; TYP. ELEVATION POINT #002 ELEVATION POINT #003 ELEVATION POINT #004ELEVATION POINT #005 POINT #006 ELEVATION POINT #008 EXEMPT DORMER PER26.575.20 F 2.(g) 7896 7896 7897 7898 7896 ON GRADEPATIO ON GRADEPATIO DECK 7898 97 Height overtopography issupposed to be anabsolute point inspace that is notdependent on grade. Therefore on asymmetrical gablesuch as the one onthis house, thatabsolute hight pointshould be identical onboth sides. Revise. ELEV 7896 ON PAT 24'-1 29/32"DESIGN CORPSALIUS DESIGN CORPSALIUS ASPEN, CO219 MONARCH STREETMTE1703 ISSUE PROJECT No:DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGNCORPS LLC. ALL RIGHTS RESERVED NORTH ELEVATION 4.1 04/17/2017SCHEMATIC I SET 05/09/2017SCHEMATIC II SET 05/15/2017RDS06/28/2017PERMIT SET 88'-10"LOWER LEVEL 88'-10"LOWER LEVEL 100'-0"MAIN LEVEL 100'-0"MAIN LEVEL 111'-0"UPPER LEVEL 111'-0"UPPER LEVEL 122'-0"ROOF 122'-0"ROOF VERTICAL T&G WOODSIDING WOOD FASCIA DRYSTACK STONEVENEER FLAT ROOFSYNTHETIC SLATE SHINGLE LINE OFFINISHED GRADE124 125 119 120 116 115 113114 112 218 217 123 117 211214213212 122121127 126 118 215216 128 576 1432 EGRESS WINDOW BEYOND LINE OF FOUNDATIONWALL/FOOTER 0 2'4'8'SCALE: 1/4" = 1'-0"1 NORTH ELEVATION Add to all elevations the followingitems:1) A maximum height line thatmatches the most restrictive gradeacross the elevation.2) Height points that correspond tothe height points shown on theHeight Over Topography sheet.3) A clearly labeled Finished Gradeline.4) A clearly labeled Natural Gradeline.8'-4 5/32"NO REMARK PER JIM P. ROOF PITCH REFERENCE ON ROOF PLAN MOVED REDUNDANT POINT; REVISED NO COMMENT NO COMMENT 11/27/17 Page: 45 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf In order to be considered exempt FA, the space must meet all of the criteria in 26.575.020.D.3, Attic Space and Crawlspace. Show how this space meets that criteria. Page: 45 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf This area as drawn does not meet the standards for crawl space and therefore would be considered FA. In order to be considered exempt FA, the space must meet all of the criteria in 26.575.020.D.3, Attic Space and Crawlspace Page: 89 Checkmark: Unchecked Author: jimp File Name: 219 N Monarch Permit Set.pdf It appears that these units are in the setback. Please add them to your site plan and show how they meet the standards in 26.575.020.E.5, Allowed Projections into Setbacks. GUEST SUITE MASTER CLOSET DROOM GUEST SUITECLOSET ADCB In order to beconsidered exempt FA, the space must meet all of the criteria in 26.575.020.D.3, Attic Space and Crawlspace. Showhow this space meetsthat criteria. 37.4 87.4 83'-4" 88'-10" 100'-0" ARCH = 7897MAIN FLOOR T.O. PLY LOWER LEVEL T.O. PLY CRAWL SPACE T.O. CONC. A SECTION 'A' This area as drawn does not meet the standards for crawl space and therefore would be considered FA. In order to be considered exempt FA, the space must meet all of thecriteria in 26.575.020.D.3, AtticSpace and Crawlspace It appears that these units are in thesetback. Please addthem to your site planand show how theymeet the standards in26.575.020.E.5,Allowed Projections into Setbacks. ATTIC ADDED BACKFILLED SHOWN W/ SPECS AND FENCE 11/27/17