Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.219 E Durant Ave.0130.2016 (22).ARBK
Design No. D902 BXUV.D902 Fire Resistance Ratings ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. BXUV Fire Resistance Ratings ANSI/UL 263 BXUV7 Fire Resistance Ratings CAN/ULCS101 Certified for Canada See General Information for Fireresistance Ratings ANSI/UL 263 See General Information for Fire Resistance Ratings CAN/ULCS101 Certified for Canada Design No. D902 September 22, 2016 Restrained Assembly Ratings — 1, 11/2, 2 and 3 Hr. Unrestrained Assembly Ratings — 0, 1, 11/2, 2 or 3 Hr. (See Items 4 & 6) Unrestrained Beam Ratings — 1, 11/2, 2 and 3 Hr. This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 1. Beam — W12X14, W8X28, W8x24 or W6x12, min size, see Items 6A through 6E. 1A. Steel Joists — (Not Shown) — As an alternate to Item 1 — Composite or noncomposite min 8k1 or min depth and weight shall be 8 in. and 4.9 lb/ft respectively. May be uncoated or provided with a shop coat of paint. Designed per S.J.I. specifications for a max design stress of 30, 000 psi (30 ksi). Welded or bolted to end supports. The top chords shall consist of two angles measuring 11/4 by 11/4 by 0.127 in. thick. Bottom chords shall consist of two round bars measuring 0.566 in. in diam. or two angles measuring 1 by 1 by 0.125 in. thick. Bearing plates shall consist of two angles measuring 11/2 by 2 by 0.188 in. thick and 51/16 in. long. Web members shall consist of 0.565 in. diam bars. 1B. Steel Joists — (Not Shown) — As an alternate to Item 1 — Composite or noncomposite min 12k5 or min depth and weight shall be 12 in. and 7.1 lb/ft respectively. May be uncoated or provided with a shop coat of paint. Designed per S.J.I. specifications for a max design stress of 30, 000 psi (30 ksi). Welded or bolted to end supports. Top chords shall consist of two angles measuring 11/2 by 11/2 by 0.156 in. thick. Bottom chords shall consist of two round bars measuring 0.675 in. in diam. or two angles measuring 1 by 1 by 0.125 in. thick. Bearing plates shall consist of two angles measuring 2 by 2 by 0.192 in. thick and shall be min 415/16 in long. The second web member at each end shall consist of 0.654 in. diam round bar. All remaining web members, including the end web members, shall consist of 0.774 in. diam round bars. Bridging per S.J.I. specifications is required when noncomposite joists are used. 1C. Steel Joists — (Not Shown) — As an alternate to Item 1 — Composite or noncomposite min 12k5 or min depth and weight shall be 12 in. and 7.1 lb/ft respectively. May be uncoated or provided with a shop coat of paint. Designed per S.J.I. specifications for a max design stress of 30, 000 psi (30 ksi). Welded or bolted to end supports. Top chords shall consist of two angles measuring 11/2 by 11/2 by 0.156 in. thick. Bottom chord shall consist of two round bars measuring 0.675 in. in diam. or two nangles measuring 1 by 1 by 0.125 in. thick. The second web member at each end shall consist of 0.654 in. diam round bar. All remaining web members, including the end web members, shall consist of 0.774 in. diam round bars. Bridging per S.J.I. specifications is required when noncomposite joists are used. 1D. Steel Joists — (Not Shown) — As an alternate to Item 1 — Composite or noncomposite min 8k1 or min depth and weight shall be 8 in. and 4.9 lb/ft respectively. May be uncoated or provided with a shop coat of paint. Designed per S.J.I. specifications for a max design stress of 30, 000 psi (30 ksi). Welded or bolted to end supports. The top chords shall consist of two angles measuring 11/4 by 11/4 by 0.127 in. thick. Bottom chords shall consist of two round bars measuring 0.566 in. in diam. or two angles measuring 1 by 1 by 0.125 in. thick. Bearing plates shall conform to S.J.I. specifications. Web members shall consist of 0.565 in. diam bars. 2. Normal Weight or Lightweight Concrete — Normal weight concrete, carbonate or siliceous aggregate, 3500 psi compressive strength, vibrated. Lightweight concrete, expanded shale or slate aggregate by rotarykiln method or expanded clay aggregate by rotarykiln or sinteredgrate method, or pelletized expanded blast furnace slag aggregate, 3000 psi compressive strength, vibrated, 4 to 7 per cent entrained air. Restrained Assembly Rating Hr Concrete (Type) Concrete Unit Weight pcf Concrete Thkns In. 1 Normal Weight 147153 31/2 11/2 Normal Weight 147153 4 2 Normal Weight 147153 41/2 3 Normal Weight 147153 51/4 1 Lightweight 107113 21/2 1 Lightweight 107120 25/8 11/2 Lightweight 107113 3 2 Lightweight 107113 31/4 2 Lightweight 107116 31/4* 2 Lightweight 114120 31/2 3 Lightweight 107113 43/16 3 Lightweight 114120 47/16 * With 2 and 3 in. deep steel floor units only. 3. Welded Wire Fabric — 6x6 10/10 SWG. 3A. Negative Reinforcement — (Not Shown) — Optional Used in lieu of Item 3 and with Items 3B or 3C. For floor spans with concrete cast continuous over the supporting beams. Deformed bars designed to resist the support moments of the concrete slab in accordance with the latest ACI Building Code Specifications. 3B. Fiber Reinforcement* — (Not Shown) — Required with Item 3A. Engineered synthetic fibers added to concrete mix to control shrinkage cracks in concrete. Fibers added to concrete mix at rate of 1 lb of fiber for each cubic yard of concrete. PROPEX OPERATING COMPANY L L C — Fibermesh 150 and Fibermesh 300. 3C. Fiber Reinforcement* — (Not Shown) — Required with Item 3A. Any fiber reinforcement bearing the UL Classification Marking for Fire Resistance, Classified for use in lieu of welded wire fabric. See Fiber Reinforcement (CBXQ) Category for names of manufacturers. 4. Steel Floor and Form Units* — Composite 11/2, 15/8 , 2 or 3 in. deep galv units or 41/2 in. deep non composite galv units. Fluted units may be phos/ptd. Min gauges are 22 MSG for fluted and 20/20 for cellular and partial cellular units. The following combinations of units may be used: (1) All 24, 26, 28 or 36 in. wide cellular or partial cellular. (2) All fluted. (3) One or two 3 in. deep, 12 in. wide, 18/18 MSG min cellular alternating with 3 in. deep fluted or other cellular. (4) Any blend of fluted and 24, 26, 28 or 36 in. wide cellular or partial cellular. (5) Corrugated, nom 15/16 or 2 in. deep, 30 in. wide, 24 MSG min galv units with shear wires factory welded to deck corrugations. Welded to supports 12 in. OC through welding washers. For shear wire spacing of 8 in. or less the steel deck stress shall not exceed 20 KSI. For shear wire spacing greater than 8 in. OC but less than or equal to 12 in. OC steel deck stress shall not exceed 12 KSI. ASC STEEL DECK, DIV OF ASC PROFILES L L C — 32 in. wide Types NH32, NHN32, NHF32; 36 in. wide, Types BH 36, BHN36, BHN351/4, BHF36, BHF36A, 2WH36, 2WHS36, 2WHF36, 2WHF36A, 3WxH36, 3WxHF36, 3WxHF36A, 3WH36, 3WHF36, 3WHF36A, 3W36, 3WF36, DG3W36, DG3WF36. All units may be galvanized or Prime Shield. Noncellular decks may be vented designated with a "V" suffix to the product name. Cellular deck top and bottom sections may be riveted together (designated with "Fr") vs. arc spot welded, "F" CANAM STEEL CORP — 24 in. wide Type P2432 composite or 36 in. wide Type P3623, P3606, P3615 and 24 in wide Type P2432 composite, Type P3606 and P3615 noncomposite CANAM STEEL CORP — 12 or 24 in. wide, Types 11/2, 2, or 3 in. LOKFloor and LOKFloor Cell; 36 in. wide, Types 2 or 3 in. LOKFloor and LOKFloor Cell; 24, 30 or 36 in. wide, Type 11/2 in. BLOK and BLOK Cell; 24 in. wide, Types NLOK and NLOK Cell CENTRIA — QL Types, 24 in. wide, 3 or 3 inverted, UKX, 21 or 21 inverted, 2 in. 99, 121, AKX, NKX, TKX; 24 or 30 in. wide GKX, GKXH, GKXA; 36 in. wide 2 in. 99, AKX, WKX; 12 in. wide NKC, TKC; 12 in. wide noncomposite Sec 12. Side joints of 99, 121, TKC, TKX, WKX may be welded together 60 in. OC. Side joints of 99, AKX, WKX, GKX, GKXA, TKX may be fastened together with min 1 in. long No. 12x14 selfdrilling, selftapping steel screws 36 in. OC CHIA TEH CONSTRUCTION MATERIAL CO LTD — 24 or 36 in. wide MacLok 3; 24 in. wide CFD3 DECK WEST INC — 36 in. wide Type BDW, Inverted BDW, BADW, Inverted BADW, 2DW or 3DW. Side joints of Type 2DW and 3DW may be fastened together with min 1 in. long No. 12 x 14 selfdrilling, selftapping steel screws 36 in. OC DESIGN ASSISTANCE CONSTRUCTION SYSTEMS INC — 36 in. wide Type DACS1.5CD, or 24 in. wide Type DACS2.0CD, or DACS3.0CD EPIC METALS CORP — 24 in. wide Types EC150, EC150 inverted, EC300, EC366, ECP150, ECP300, ECP366, ECA; 30 in. wide Types ECB150, ECBR150; 36 in. wide Types EC156, EC266, ECP266 KAM INDUSTRIES LTD, DBA CORDECK — 24 in. wide, Types 2 or 3 in. WDR MARLYN STEEL DECKS INC — Type 1.5 CF, 2.0 CF or 3.0 CF MORIN CORP — 24, 30 or 36 in. wide Types LXRB, LXRB inverted; 24 or 36 in. wide Type LXR3W; 36 in. wide Type LXR2W NEW MILLENNIUM BUILDING SYSTEMS L L C — 24 in. wide Types CFD2, CFD3; 24, 30 or 36 in. wide Type CFD 1.5; 24 or 36 in. wide Types MacLok 2, MacLok 3; 24 in. wide Types B2C, B2FC, NC, NFC; 30 in. wide, Type B3C; 12 in. wide MacWay Cellular 45 MDW, 2633 MTWA, 3633 MTWA+. 30 in. wide, MacCor Types 1 and 2 NEW MILLENNIUM BUILDING SYSTEMS L L C — Type 1.5CD, 1.5CDI, 1.5CDR, 2.0CD, or 3.0CD. Units may be phos/painted or galvanized ROOF DECK INC — 36 in. wide Types LOK11/2, LOK11/2R; 24 in. wide Types LOK2, LOK3 VALLEY JOIST — 24 or 36 in. wide Types WVC 11/2 or WVC 2 VERCO DECKING INC A NUCOR CO — 24, 30 or 36 in. wide Types PLB, PLBCD, B, BCD, BR; 24 or 36 in. wide Types PLW2, PLW2CD, W2, W2CD, PLW3, PLW3CD, W3, W3CD; 24 in. wide Types PLN, PLNCD, N, NCD . 12 in. wide PLW2, W2, PLW3 or W3 units may be blended with 24 or 36 in. wide PLW2, W2, PLW3 or W3 units, respectively; or Types PLN3CD, N3CD, PLN3, N3. Fluted units may be phos/ptd VULCRAFT, DIV OF NUCOR CORP — 24, 30 or 36 in. wide Types 1.5VL, 1.5VLI, 1.5PLVLI, 1.5VLP, 1.5 VLR, 1.5PLVLP; 24 or 36 in. wide Types 1.5VLPA, 1.5PLVLPA, 2VLI, 2.0PLVLI, 2VLJ, 3VLI, 3.0PLVLI, 3VLJ, 2VLP, 2.0PLVLP, 3VLP, 3.0PLVLP, 2VLPA, 2.0PLVLPA, 3VLPA, 3.0PLVLPA. Types 1.5VL, 1.5VLI, 1.5PLVLI, 1.5 VLR, 1.5VLPA, 1.5PLVLPA, 2VLI, 2.0PLVLI, 2VLJ, 3VLI, 3.0PLVLI, 3VLJ units may be phos/ptd. 24 or 36 in. wide Types 2VLJ, 3VLJ units ++ may be used for max 2 hr Restrained Assembly Rating. 36 in. wide Types 1.5 SB, 1.5 SBR; 24 or 36 in wide Types 2.0 SB, 3.0 SB, 36 in. wide Type High Strength 1.5 SBI, 36 in. wide Type High Strength 1.5 SBN; Units may be phos/ptd Spacing of welds attaching units to supports shall be 12 in. OC for 12, 24, 36 in. wide units, four welds per sheet for 30 in. wide units. 6 in. OC for 18 in. wide and Sec. 12 units. Unless specified otherwise for specific units types, adjacent units buttonpunched or welded together 36 in. OC along side joints. For 3 Hr Rating, units with overlapping type side joints welded together 24 in. OC max. When a superimposed load of 250 PSF is desired the spacing of welds or buttonpunches shall not exceed 24 in. OC along side joints. + 12 in. wide, 11/2 in. deep MacWay units may be blended with 24 in. wide B2C or 30 in wide B3C units in a blend of one cell to one or more fluted units. 12 in. wide, 2 in. deep MacWay units may be blended with 24 or 36 in. wide Mac Lock units in a blend of one cell to one or more fluted units. 12 in. wide, 3 in. deep MacWay units may be blended with 24 or 36 in. wide MacLock 3 units in a blend of one cell to one or more fluted units. The side edge of the fluted units is placed on the top of the side edge of the MacWay unit and the two are welded together with welding washers spaced a max. of 32 in. OC for MacLock 2 or 3 units and a max of 24 in. OC for the B2C or B3C units. ++ Side joints of Types 2VLJ or 3VL J units may be fastened together with No. 83/4 in. long selfdrilling Tek screws driven diagonally from the top side through the joint of the units at 36 in. O. C. max. Alternate Construction — Noncomposite units of the same type listed above may be used provided allowable loading is calculated on the basis of noncomposite design. The Unrestrained Assembly Rating is equal to the Unrestrained Beam Rating (See Item 6) for a max 3 Hr and is limited to the following units and limitations: (a) 11/2, 2 and 3 in. deep, 24 in. wide, 22 MSG or thicker fluted with clear spans not more than 7 ft, 8 in. (b) 11/2, 2 and 3 in. deep, 24 in. wide, 20 MSG or thicker fluted with clear spans not more than 8 ft, 8 in. (c) 11/2 and 2 in. deep, 24 in. wide, 16 MSG or thicker fluted and 18/18 MSG or thicker cellular with clear spans not more than 9 ft, 11 in. (d) 3 in. deep, 36 in. wide, 18 MSG or thicker fluted and 24 in. wide, 20/18 MSG or thicker cellular with clear spans not more than 13 ft, 2 in. For assemblies utilizing 31/4 in. lightweight concrete topping with a max Restrained Assembly Rating of 2 Hr, the Unrestrained Assembly Rating is equal to the Unrestrained Beam Rating (See Item 6) and is limited to the following floor units and spans: (a) 11/2, 2 and 3 in. deep, 24 or 36 in. wide, 22 MSG fluted and 20/20 MSG cellular with clear spans not more than 9 ft, 6 in. (b) 2 and 3 in. deep, 24 or 36 in. wide, 20 MSG fluted and 20/20 MSG cellular with clear spans not more than 10 ft, 0 in. (c) 3 in. deep, 24 in. wide, 20 MSG fluted and 20/20 MSG cellular with clear spans not more than 13 ft, 2 in. 4A. Steel Floor and Form Units* — As an alternate to Item 4, for use only when top of steel beam (Item 1) is filled solid with concrete for the full width of bearing from top of steel beam to top of concrete (Item 2): BAILEY METAL PRODUCTS LTD — Type COMSLAB™ 210 and COMSLAB™ 225, Steel End Closure Flashing 5. Joint Cover — (Use with fluted units optional — Not Shown) — 2 in. wide cloth adhesive tape applied following the contour of the units. 6. SprayApplied Fire Resistive Materials* — Applied by spraying with water, in one coat to a final thickness as shown above and in table below to steel beam surface which is free of dirt, oil or scale. When fluted steel deck is used and the fire protection thickness selected is based on all fluted deck, the area between the steel deck and the top flange of the steel beam shall be filled. When fluted steel deck is used and the steel beam is sprayed with the thicknesses applicable to cellular or blended units, the area between the steel deck and the top flange of the steel beam shall be plugged. Use of adhesive is optional. Min avg untamped density is 13 pcf with min ind untamped density of 11 pcf for Types II or DC/F. Min avg and min ind untamped densities of 22 and 19 pcf, respectively, for Type HP. Tamping is optional. For method of density determination, refer to Design Information Section. The thickness of the Spray Applied Fire Resistive Materials on the Structural Members (Item 1, 1A, or 1B) shall be as follows: Restrained Assembly Rating Hr Unrestrained Beam Rating Hr Concrete Type Protection Mtl Thkns on Structural Member In. W8x28 When Deck Is All Fluted W8x28 When Deck Is Blend or All Cellular W12x14 When Deck Is All Fluted Joist Item 1A When Deck Is Fluted Cellular or Blend Joist Item 1B When Deck Is Fluted Cellular or Blend 1 1 NW 3/8,5/8**1/2+,11/16**9/16,15/16**1++— 11/2 1 NW 3/8,5/8**1/2+,11/16**9/16,15/16**19/16 — 2 1 NW 3/8,5/8**1/2+,11/16**9/16,15/16**21/16 — 2 2 NW 3/4 13/8+11/16 21/16 — 2 3 NW 13/16 21/8+111/16 —31/4 3 11/2 NW 1/2 7/8*3/4 —31/4 3 2 NW 3/4 13/8+11/16 —31/4 3 3 NW 13/16 21/8+111/16 —31/4 1 1 LW 3/8,5/8**1/2+,11/16**9/16,15/16**1 1/8++ — 11/2 1 LW 3/8,5/8**1/2+,11/16**9/16,15/16**13/4 — 2 1 LW 3/8,5/8**1/2+,11/16**9/16,15/16**21/4 — 2 2 LW 1 13/8+17/16 21/4 — 2 3 LW 19/16+21/8+21/4 —31/4 3 11/2 LW 11/16 7/8*1 —31/4 3 2 LW 1+13/8+17/16 —31/4 * May be reduced to 3/4 in. for the 11/2 hr Unrestrained Beam Rating when the material is sprayed 2 in. beyond the beams's top flange and no reduction in thickness is made at the tips of the bottom flange. ** This thickness applies when optional Item 12 or 13 are used over 31/4 in. lightweight concrete topping. + Thickness of SprayApplied Fire Resistive Materials may be reduced to one half of this thickness on the lower flange tips of the steel beam. ++ When bottom chords consist of 1 by 1 by 0.125 in. thickn steel angles, the thickness of sprayapplied fire resistive material shall be increased by 1/4 in. on the bottom chord only. ISOLATEK INTERNATIONAL — Type DC/F, HP, Type II, Type EBS or Type X adhesive which may also be used as a surface sealer 6A. SprayApplied Fire Resistive Materials* — Alternate to Item 6. See table below for appropriate thicknesses. When fluted steel deck is used and the fire protection thickness selected is based on all fluted deck, the area between the steel deck and the top flange of the steel beam shall be filled. When fluted steel deck is used and the steel beam is sprayed with the thicknesses applicable to cellular or blended units, the area between the steel deck and the top flange of the steel beam shall be plugged. Prepared by mixing with water and sprayapplied in one or more coats to beam surfaces which must be clean and free of dirt, loose scale and oil. Min average density of 17.5 pcf with min individual value of 17.0 pcf. For method of density determination, see Design Information Section, Sprayed Material. Restrained Assembly Rating Hr Unrestrained Beam Rating Hr Protection Thkns on W8x28, In. When Deck Is All Fluted When Deck Is Blend or All Cellular 1, 11/2, 2 1 5/16, 7/16*5/16, 7/16* 2 2 11/16 13/16 2 3 11/16 15/16 3 11/2 1/2 9/16 3 2 11/16 13/16 3 3 11/16 15/16 * This thickness applies when optional Items 12, 13 are used over 31/4 in. lightweight concrete topping. +++ When bottom chords consist of 1 by 1 by 0.125 in. thick steel angles, the thickness of sprayapplied fire resistive material shall be increased by 1/4 in. on the bottom chord only. ISOLATEK INTERNATIONAL — Type 280 6B. SprayApplied Fire Resistive Materials* — Alternate to Item 6 or 6A. Applied by mixing with water according to instructions on each bag of material. Mixture can be spray or trowel applied in one or more coats. The thickness of the mixture is dependent on the type of floor unit. See table below for appropriate thickness. When fluted steel deck is used and the fire protection thickness selected is based on all fluted deck, the area between the steel deck and the top flange of the steel beam shall be filled. When fluted steel deck is used and the steel beam is sprayed with the thicknesses applicable to cellular or blended units, the area between the steel deck and the top flange of the steel beam shall be plugged. The steel surfaces must be clean and free of dirt, loose scale and oil. Minimum average density of 38 pcf and minimum individual density of 35 pcf for Type 800. Min avg density of 44 pcf with min ind value of 40 pcf for Type MII. Min avg density of 47 pcf, with min individual value of 43 pcf for Type MII/P. Min avg density of 44 pcf with min ind value of 42 pcf for Type TG. For method of density determination, refer to Design Information Section, Sprayed Material. Restrained Assembly Rating Hr Unrestrained Beam Rating Hr Protection Thkns on W8x28, In. When Deck Is All Fluted When Deck Is Blend or All Cellular 1, 11/2, 2 1 3/8, 1/2*7/16, 9/16* 2 2 15/16 11/4 2 3 15/16 11/2 3 11/2 5/8 1 3 2 15/16 11/4 3 3 15/16 11/2 * This thickness applies when optional Item 12 or 13 are used over 31/4 in. lightweight concrete topping. BERLIN CO LTD — Types MII or TG. Types MII and TG Investigated for exterior use GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Types MII, MII/P or TG. Types MII, MII/P and TG Investigated for exterior use ISOLATEK INTERNATIONAL — Types 800, MII, MII/P or TG investigated for exterior use NEWKEM PRODUCTS CORP — Types MII or TG. Types MII and TG Investigated for exterior use 6C. SprayApplied Fire Resistive Materials* — Alternate to Items 6A or 6B. Applied by mixing with water in accordance with instructions on each bag and applied in one or more coats to a final thickness as shown in table below to steel beam surface which is free of dirt, oil or scale. When fluted steel deck is used and the fire protection thickness selected is based on all fluted deck, the area between the steel deck and the top flange of the steel beam shall be filled. When fluted steel deck is used and the steel beam is sprayed with the thicknesses applicable to cellular or blended units, the area between the steel deck and the top flange of the steel beam shall be plugged. Min average and min individual density is 15 and 14 pcf, respectively, for Types 300, 300AC, 300ES, 300HS, 300N, 3000, 3000ES and SB. For Types 400AC and 400ES min average and min individual density of 22 and 19 pcf, respectively. For method of density determination, refer to Design Information Section. The thickness of the material on the Structural Members (Item 1, 1C, or 1D) shall be as follows: Restrained Assembly Rating Hr Unrestrained Beam Rating Hr Protection Mtl Thkns on Structural Members In. W8x28 When Deck Is All Fluted W8x28 When Deck Is Blend or All Cellular W12x14 When Deck Is All Fluted Joist (Item 1C or 1D) When Deck Is Fluted Cellular or Blend 1 1 5/16, 7/16* 5/16, 7/16* 1/2,5/8*9/16 11/2 1 5/16, 7/16* 5/16, 7/16* 1/2,5/8*1 2 1 5/16, 7/16* 5/16, 7/16* 1/2,5/8*13/8 2 2 11/16 13/16 1 13/8 2 3 11/16 15/16 11/2 21/4 3 11/2 1/2 9/16 3/4 21/4 3 2 11/16 13/16 1 21/4 3 3 11/16 15/16 11/2 21/4 * This thickness applies when optional Item 12 or 13 are used over 31/4 in. lightweight concrete topping. BERLIN CO LTD — Type 300, Type 300ES, Type 300N or Type SB GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Types 300, 300AC, or 400AC ISOLATEK INTERNATIONAL — Type 300, Type 300AC, Type 300ES, Type 300HS, Type 300N, Type SB, Type 400AC, Type 400ES, Type 3000 or Type 3000ES NEWKEM PRODUCTS CORP — Type 300, Type 300ES, Type 300N, or Type SB 6D. SprayApplied Fire Resistive Materials* — Alternate to Items 6A, 6B or 6C. Applied by mixing with water in accordance with instructions on each bag and applied in one or more coats to a final thickness as shown in table below to steel beam surface which is free of dirt, oil or scale. When fluted steel deck is used and the fire protection thickness selected is based on all fluted deck, the area between the steel deck and the top flange of the steel beam shall be filled. When fluted steel deck is used and the steel beam is sprayed with the thicknesses applicable to cellular or blended units, the area between the steel deck and the top flange of the steel beam shall be plugged. Min average and min individual density is 17.5 and 16 pcf, respectively, for 300TW. Min average and min individual density of 22 and 19 pcf, respectively, for Type 400. For method of density determination, refer to Design Information Section. The thickness of the material on the Structural Members (Item 1, 1C, or 1D) shall be as follows: Restrained Assembly Rating Hr Unrestrained Beam Rating Hr Protection Mtl Thkns on Structural Members In. W8x28 When Deck Is All Fluted W8x28 When Deck Is Blend or All Cellular W12x14 When Deck Is All Fluted Joist (Item 1C or 1D) When Deck Is Fluted Cellular or Blend 1 1 5/16, 7/16*5/16, 7/16*1/2,5/8*9/16 11/2 1 5/16, 7/16*5/16, 7/16*1/2,5/8*1 2 1 5/16, 7/16*5/16, 7/16*1/2,5/8*13/8 2 2 11/16 13/16 1 13/8 2 3 11/16 15/16 11/2 21/4 3 11/2 1/2 9/16 3/4 21/4 3 2 11/16 13/16 1 21/4 3 3 11/16 15/16 11/2 21/4 * This thickness applies when optional Item 12 or 13 are used over 31/4 in. lightweight concrete topping. BERLIN CO LTD — Type 400 GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Type 400 ISOLATEK INTERNATIONAL — Type 300TW, Type 400 NEWKEM PRODUCTS CORP — Type 400 6E. Mastic and Intumescent Coatings* — As an alternate to Items 6 through 6D. For use with fluted steel floor and form units only. Min. size W8x24 or W6x12 beams shall be primed with a phenolic modified alkyd primer, a metal alkyd primer, an acrylic primer or an epoxy primer at a nominal thickness of 2 mil. Coating spray or brush applied in accordance with the manufacturer's instructions at the min dry thickness as shown in the table below. The thickness shown below includes the primer thickness. Flutes above beam to be completely filled with minimum 6 pcf mineral wool insulation, or the top flange of the beam to be protected with the same thickness of coating as required on the beam. Minimum Dry Thickness mils Minimum Dry Thickness mm Beam Size Unrestrained Beam Rating Hr Restrained Assembly Rating Hr 53 1.34 W8x24 1 2 95 2.41 W8x24 11/2 3 73 1.83 W6x12 1 2 123 3.10 W6x12 11/2 3 BERLIN CO LTD — Type WB 3. Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB4, Investigated for Exterior Use with top coat as described in Item 6F GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Type WB 3. Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB4, Investigated for Exterior Use with top coat as described in Item 6F ISOLATEK INTERNATIONAL — Type SprayFilmWB 3 and Type WB 3. Investigated for Interior General Purpose. Type SprayFilmWB 4 and Type WB 4, Investigated for Interior General Purpose. Type SprayFilmWB 4 and Type WB4, Investigated for Exterior Use with top coat as described in Item 6F NEWKEM PRODUCTS CORP — Type WB 3. Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB4, Investigated for Exterior Use with top coat as described in Item 6F 6F. Mastic and Intumescent Coatings* — As an alternate to Items 6 through 6E. For use with normal weight concrete. Min. size W8x28 beams shall be primed with a phenolic modified alkyd primer a metal alkyd primer, an acrylic primer or an epoxy primer at a nominal thickness of 2 mil. Coating spray or brush applied in accordance with the manufacturer's instructions at the min dry thickness as shown in the table below. The thickness shown below includes the primer thickness. The top surface of the top flange where fluted units are used must be protected with the coating material at the same min dry thickness at a min distance of 1 in. (25 mm) inward from the flange tip on both sides of the beam. Mineral wool insulation optional above top surface of the beam. Minimum Dry Thickness mils Minimum Dry Thickness mm Steel Floor Units Unrestrained Beam Rating Hr Restrained Assembly Rating Hr 103 2.62 Fluted or Cellular 11/2 2 179 4.55 Cellular 11/2 3 341 8.67 Cellular 2 3 BERLIN CO LTD — Type WB 3. Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB 4, Investigated for Exterior Use with top coat as described in Item 6G GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Type WB 3, Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB 4, Investigated for Exterior Use with top coat as described in Item 6G ISOLATEK INTERNATIONAL — Type SprayFilmWB 3 and Type WB 3. Investigated for Interior General Purpose. Type SprayFilmWB 4 and Type WB 4, Investigated for Interior General Purpose. Type SprayFilmWB 4 and Type WB 4, Investigated for Exterior Use with top coat as described in Item 6G NEWKEM PRODUCTS CORP — Type WB 3. Investigated for Interior General Purpose. Type WB 4, Investigated for Interior General Purpose. Type WB4, Investigated for Exterior Use with top coat as described in Item 6F 6G. Top Coat — Type SprayFilm — TOPSEAL and Type TOPSEAL required for Exterior Use, applied at a minimum dry thickness of 14 mils (0.34 mm) over the intumescent material. See Classification information in the Mastic and Intumescent Coating (CDWZ) category, Isolatek International, for mixing requirements. 6H. Mastic and Intumescent Coatings* — As an alternate to Items 6 through 6F. For use with normal weight or light weight concrete and fluted steel floor and form units only. Min size W8x24 beams shall be primed with a phenolic modified alkyd primer at a thickness of 2 mils or a epoxy primer at a nominal thickmess of 1 mil. Coating spray or brush applied in accordance with the manufacturer's instructions at the thicknesses shown below. The thickness includes the thickness of primer. The top surface of the top flange where fluted units are used must be protected with the coating material at the same min dry thickness or filled with nominal 4 pcf mineral wool. Minimum Dry Thickness mils Minimum Dry Thickness mm Unrestrained Beam Rating Hr Restrained Assembly Rating Hr 35 0.88 1 2 66 1.68 11/2 3 GREENTECH THERMAL INSULATION PRODUCTS MFG CO L L C — Type SprayFilmWB5 and Type WB5. Investigated for Interior General Purpose ISOLATEK INTERNATIONAL — Type SprayFilmWB5 and Type WB5. Investigated for Interior General Purpose 7. Shear Connector Studs — Optional — Studs, 3/4 in. diam by 3 in. long, for 11/2 in. deep form units to 51/4 in. long for 3 in. deep form units, headed type or equivalent per AISC specifications. Welded to the top flange of the beam through the steel form units. 8. Lath Hanger — (Not Shown) — Optional For use in caged beams with Items 6, 6A, 6B or 6C Galv steel 6 SWG min diam spaced 27 in. O. C. 9. Clips — (Not Shown) — Optional For use in caged beams with Items 6, 6A, 6B or 6C No. 24 MSG spring steel pushed on to top and bottom flanges of beam spaced 6 in. O. C. max. 10. Metal Lath — (Not Shown) — Optional For use in caged beams with Items 6, 6A, 6B or 6C 3/8 in. diamond mesh or rib lath, 3.4 lbs per sq yd expanded steel attached to beam with clips spaced 6 in. OC max; or tied to lath hangers with 18 SWG galv steel wire spaced 6 in. OC max. 11. Electrical Inserts* — (Not Shown) — Classified as "Outlet Boxes and Fittings Classified for Fire Resistance". 12. Mineral and Fiberboards* — (Optional, Not Shown) — Applied over concrete floor with no restriction on board thickness. When mineral and fiber boards are used, the unrestrained beam rating shall be increased by a minimum of 1/2 hr. See Mineral and Fiber Board (CERZ) category for names of manufacturers. 13. Foamed Plastic* — (Optional, Not Shown) — Consisting of polyisocyanurate or urethane roof insulations. Applied over concrete floor with no restrictions on thickness. When polyisocyanurate or urethane insulation is used, the unrestrained beam rating shall be increased by a minimum of 1/2 hr. See Foamed Plastic (CCVW) for list of manufacturers. 14. Insulating Concrete — (Optional, Not Shown) — Various types of insulating concrete prepared and applied as follows: A. Vermiculite Concrete Blend 6 to 8 cu ft of Vermiculite Aggregate* to 94 lb Portland cement and air entraining agent. Min thickness of 2 in. as measured to the top surface of the structural concrete or foamed plastic (Item 15) when it is used. See Vermiculite Aggregate (CJZZ) category for names of Classified companies. B. Cellular ConcreteRoof Topping Mixture* Concentrate mixed with water and Portland cement per manufacturer's specifications. Min. thickness of 2in. as measured to the top surface of the structural concrete or foamed plastic (Item 15 and 15A) when used. Cast dry density and 28day min compressive strength of 190 psi as determined with ASTM C49566. AERIX INDUSTRIES — Cast dry density of 37 (+ or ) 3.0 pcf CELCORE INC — Type Celcore with cast dry density of 31 (+ or 3.0) pcf or Type Celcore MF with cast dry density of 29 (+ or 3.0) pcf ELASTIZELL CORP OF AMERICA — Type II, with a cast dry density of 39 (+ or 3.0) pcf LITECRETE INC — Cast density of 29 (+ or ) 3.0 pcf SIPLAST INC — Mix #1, Cast dry density of 32 (+ or ) 3 pcf SIPLAST INC — Mix #2, Cast dry density of 36 (+ or ) 3 pcf C. Cellular ConcreteRoof Topping Mixture* Foam concentrate mixed with water, Portland cement and UL Classified Vermiculite Aggregate per manufacture's application instructions. Cast dry density of 33 (+ or ) 3 pcf and 28 day compressive strength of min 250 psi as determined in accordance with ASTM C49586. AERIX INDUSTRIES — Mix #3 ELASTIZELL CORP OF AMERICA — Type II. Mix #1 of cast dry density 39 (+ or ) 3.0 pcf, Mix #2 of cast dry density 40 (+ or ) 3.0 pcf, Mix #3 of cast dry density 47 (+ or ) 3.0 pcf SIPLAST INC — Mix #3 D. Perlite Concrete 6 cu ft of Perlite Aggregate* to 94 lb of Portland Cement and 11/2 pt air entraining agent. Min thickness 2 in. as measured to the top surface of structural concrete or foamed plastic (Item 15A) when it is used. See Perlite Aggregate (CFFX) in Fire Resistance Directory for names of Classified companies. 15. Foamed Plastic* — (Optional, Not Shown) — For use only with vermiculite (Item 14A) or cellular (Item 14B) concretesRigid polystyrene foamed plastic insulation having slots and/or holes sandwiched between vermiculite concrete slurry which is applied to the normal or lightweight concrete surface and vermiculite concrete topping (Item 14A). See Foamed Plastic* (BRYX) category in Building Materials Directory or Foamed Plastic* (CCVW) Category in Fire Resistance Directory for list of Classified companies. 15A. Foamed Plastic* — (Not Shown) — For use only with cellular or perlite concrete. Nominal 24 by 48 in. polystyrene foamed plastic insulation boards having a density of 1.0 (+ or 0.1) pcf, encapsulated within concrete topping. Each insulation board shall contain six nominal 3 in. diameter holes oriented in two rows of three holes each with the holes spaced 12 in. OC transversely and 16 in. OC longitudinally. See Foamed Plastic* (BRYX) category in Building Materials Directory or Foamed Plastic* (CCYW) category in Fire Resistance Directory for list of Classified companies. 16. Roof Covering Materials* — (Optional, Not Shown) — Consisting of materials compatible with insulations described herein which provide Class A, B or C coverings. See BuiltUp Roof Covering Materials in Building Materials Directory. 17. Insulated Concrete — (Optional, Not Shown) — various types of insulated concrete prepared and applied in the thickness indicated. A. Vermiculite Concrete — Mix consists of 6 cu ft of Vermiculite Aggregate*, 94 lbs of Portland cement and 6 ox of air entraining agent. Thickness to be 2 in min from the top plane of steel roof deck. ELASTIZELL CORP OF AMERICA — Types MS16U, MSV 200. B. Perlite Concrete — Mix consists of 6.2 cu ft Perlite Aggregate* to 94 lbs of Portland cement and 11/2 pt air entraining agent. Compressive strength 80 psi min. See Perlite Aggregate (CFFX) category for names of Classified companies. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 20160922 Questions?Print this page Terms of Use Page Top © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's FollowUp Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's FollowUp Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2016 UL LLC".