File Documents.211 Cottonwood Ln.0062.2019 (49).ARBK
03/27/2019 Job Name: System Reference:Date: GENERAL FEATURES • Ceiling-recessed cassette (24"x24") ductless heat pump •Install SLZ in a drywalled ceiling (with an access panel for servicing) or in a 2'x2' drop ceiling • Wide airflow pattern for excellent air distribution • Fresh air intake provided in the main body • Built-in drain condensate lift mechanism • Multiple control options available: - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Long-life air filter included SUBMITTAL DATA: SLZ-KA15NA 15,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES FC-1 03/27/2019 Cooling Capacity1, 3 Btu/h 15,000 Heating Capacity2, 3 Btu/h 18,000 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 MCA A 1 Blower Motor Full Load Amperage A 0.28 Blower Motor Output W 20 Airflow Rate at Cooling, Dry CFM 390-320-280 Airflow Rate at Cooling, Wet CFM 350-290-250 Airflow Rate at Heating, Dry CFM 390-320-280 Sound Pressure Level (Cooling)dB(A)40-35-31 Sound Pressure Level (Heating)dB(A)40-35-31 Drain Pipe Size In. (mm)1 1/4 (32) Condensate Lift Mechanism, Maximum Distance Ft. (m)19-11/16 (500) Heat Exchanger Type Plate fin coil External Finish Color Munsell 6.4Y 8.9/0.4 Unit Dimensions W: In. (mm)22 7/16 (570) D: In. (mm)22 7/16 (570) H: In. (mm)9 1/4 (235) Package Dimensions W: In. (mm)24 13/32 (620) D: In. (mm)27 15/16 (710) H: In. (mm)9 7/16 (240) Unit Weight Lbs. (kg)36 (17) Package Weight Lbs. (kg)43 (20) Refrigerant Type R410A Charge Lbs, oz 2, 9 Notes: Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the MXZ unit. For reference to connected capacity charts, please refer MXZ Multi-Zone Outdoor Unit Operational Performance. SPECIFICATIONS: SLZ-KA15NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 03/27/2019 Signal Receiver □ PAR-SA9CA-E Wireless Remote Controller □ PAR-FL32MA-E Wireless Remote Receiver □ PAR-FA32MA-E Backlit, Wall-mounted, Wireless Controller □ MHK1 Portable Central Controller □ MCCH1 Wired MA Controller □ PAR-33MAA Simple MA Controller □ PAC-YT53CRAU Touch MA Controller □ PAR-CT01MAU-SB Wired Remote Sensor □ PAC-SE41TS-E Lockdown Bracket for Wireless, Hand-held, Remote Controller □ RCMKP1CB Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 □ MOS1 Wireless Interface □ PAC-USWHS002-WF-1 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Connector cable for remote display □ PAC-SA88HA-EP Connector for CN32 (remote on/off)□ PAC-SE55RA-E Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error)1 □ PAC-SF40RM-E External Drain Pump □ PAC-KE07DM-E Blue Diamond Sensor Extension Cable—15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft.□ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump—230V application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] □ X87-711 - 110V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h [recommended] □ X87-721 - 208/230V Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow)□ DPLS2 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black □ TAZ-MS303 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White □ TAZ-MS303W 1/4" x 1/2" x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-15 1/4" x 1/2" x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-30 1/4" x 1/2" x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-50 1/4" x 1/2" x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-65 1/4" x 1/2" x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-100 1 Unable to use with wireless remote controller ACCESSORIES: SLZ-KA15NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 03/27/2019 Detail drawing of fresh air intake Ceiling surface Cut out hole 2-7/8(73.4) Burring hole 3-1/8(2.8) 3-15/16(100)4-21/32(118)1(25)120120+5 0(27 )+3/16 01-1/16) 73~51 ( 23 / 51 - 1~23 / 91) 73~51 ( 23 / 51 - 1~23 / 91 22-11/16~24-13/32(576~620) 22-7/16(570) 20-7/8(530) Grille Fresh air intake Drain pipe VP-25 connection (O.D.1-1/4(32)) Suspension bolt M10 or W3/8 9-1/16(230)7-5/32(182)1-7/8(48)Wiring entry Terminal block Ceiling surface 9-1/4(235)8-3/16(208)7-19/32(193)25/32(20)3-21/32(93)1-1/2~2-9/32(38~58)2-19/32(66)4-3/4(121)21/32(17)7-15/16(202)2-7/32(56)2-1/4(57)3-7/16(87)1-7/32(31)Ceiling holeSuspension bolt pitch19/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620)16-17/32(420)22-7/16(570)13-3/16(335)7-27/32(199) 13-27/32(352) 13-3/16(335) Suspension bolt pitch Ceiling hole Refrigerantpipe (gas) Refrigerantpipe (liquid)Suspension boltlower edgeUnit: inch(mm) Vane motor Drain hole Air intake grille2-5/32(55)1-3/8(35)1-3/8(35)2-5/32(55) Auto vane Grille Air intake hole Air intake holeAir outlet holeAir outlet hole 11-27/32(301)11-27/32(301)14-27/32(377)14-27/32(377)25-19/32(650)25-19/32(650) Brand label V/M V/M V/M V/M SLZ-KA15NA SLZ-KA12NA SLZ-KA09NA Models ( 6.35mm) flared connection Refrigerant pipe (liquid) Refrigerant pipe (gas) ( 9.52mm) flared connection 3/8 inch1/4 inch ( 6.35mm) flared connection 1/4 inch ( 6.35mm) flared connection 1/4 inch ( 9.52mm) flared connection 3/8 inch ( 12.7mm) flared connection 1/2 inch FORM# SLZ-KA15NA FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS - 201810 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: SLZ-KA15NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 03/27/2019 Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: Zoning Cooling Capacity*............................14,000 Btu/h Heating Capacity*............................18,000 Btu/h * Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB. (Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB. (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ-B Technical and Service Manual.) Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzMCA ..............................................1 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 .........................DC 12-24V Fan Motor ....................................0.76 F.L.A. Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling .......................205 - 272 - 335 - 420 - 533 Dry CFM170 - 237 - 300 - 385 - 498 Wet CFM Heating .....................205 - 247 - 304 - 367 - 463 CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling .........................26 - 32 - 38 - 44 - 49 dB(A) Heating .........................26 - 30 - 35 - 40 - 46 dB(A) DIMENSIONS UNIT INCHES / MM W 31-7/16 / 799 D 9-1/8 / 232 H 11-5/8 / 295 Weight.......................................22 lbs. / 10 kgExternal Finish ......................Munsell No. 1.0Y 9.2 / 0.2Field Drainpipe Size O.D.......................5/8" / 15.88 mm Refrigerant Type .....................................R410ARefrigerant Pipe Size O.D. Gas Side ..................................1/2" / 12.7 mm Liquid Side.................................1/4" / 6.35 mmConnection Method ..................................Flared SUBMITTAL DATA: MSZ-GE15NA. . . . . .15,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS GENERAL FEATURES• Wall-mounted indoor unit• Standard Hybrid Catechin Prefilter is included with indoor unit• Quiet operation• Choice of fan speeds: Quiet, Low, Medium, High, and Super High; Auto fan speed control also included• Wireless remote controller is included; PAR-21MAA wired remote controller can be installed as an option• Indoor unit powered from outdoor unit using A-Control• Auto restart following a power outage• Limited warranty: five years on parts and defects and seven years on compressors Indoor Unit: MSZ-GE15NA Wireless Remote Controller MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS SEZ-KD and PEAD-A24MSZ-GE MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE: • Ducted Indoor Units: SEZ-KD09,12,15,18NA, PEAD-A24AA • Nonducted Indoor Units: MSZ-GE06,09,12,15,18,24NA, MSZ-FE09,12,18NA, MFZ-KA09,12,18NA, PCA-A24KA, SLZ-KA09,12,15NA, and PLA-A12,18,24BA • A combination of both Ducted and Nonducted Indoor Units Refer to the separate submittal forms for the MSZ-GE, MSZ-FE, MFZ-KA, SEZ-KD, SLZ-KA, PEAD, PCA, PLA Indoor Units, and MXZ Outdoor Units.Outdoor Unit: MXZ-4B36NA MSZ-FE MFZ-KA PCA-KA SLZ-KA and PLA-ABA OPTIONAL ACCESSORIESIndoor Unit□ Condensate Pump (230V; SI3100-230)□ Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E) Controller Options□ Wall-mounted Wired Remote Controller (PAR-21MAA requires MAC-397IF)□ MA Contact Terminal Interface (MAC-397IF)□ M-NET Control Adapter (MAC-399IF)□ Remote Temperature Sensor (M21-JKO-307)□ Lockdown Bracket for Handheld Controller (RCMKP1CB) FC-2 03/27/2019 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 (#3) www.mehvac.com Specifications are subject to change without notice.C SD - MSZ-GE15NA - 201102 © MITSUBISHI ELECTRIC / HVAC 2011 DIMENSIONS: MSZ-GE15NA 03/27/2019 M-SERIES Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: ACCESSORIES The outdoor unit is delivered with the base pan heater factory installed. □Airflow Guide (PAC-SH96SG-E) □3/8" x 1/2" Port Adapter (MAC-A454JP-E) □1/2" x 3/8" Port Adapter (MAC-A455JP-E) □1/2" x 5/8" Port Adapter (MAC-A456JP-E) □1/4" x 3/8" Port Adapter (PAC-493PI) □3/8" x 5/8" Port Adapter (PAC-SG76RJ-E) □M-NET Adapter (PAC-IF01MNT-E) SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Specifications Model Name Unit Type MXZ-3C30NAHZ2 Cooling* (Non-ducted / Ducted) Rated Capacity Btu/h 28,400 / 27,400 Capacity Range Btu/h 6,000 - 28,400 Rated Total Input W 2,272 / 2,661 Heating at 47°F* (Non-ducted / Ducted) Rated Capacity Btu/h 28,600 / 27,600 Capacity Range Btu/h 7,200 - 36,000 Rated Total Input W 2,096 / 2,187 Heating at 17°F* (Non-ducted/Ducted) Rated Capacity Btu/h 18,000 / 16,500 Maximum Capacity Btu/h 28,600 / 27, 600 Rated Total Input W 1,991 / 1,993 Heating at 5°F* Maximum Capacity Btu/h 28,600 Energy Star® (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.)Yes Electrical Requirements Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Recommended Fuse/Breaker Size A 40 MCA A 30.5 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM)F.L.A.2.43 Sound Pressure Level Cooling dB(A)54 Heating 58 External Dimensions (H x W x D)In / mm 41-9/32 x 37-13/32 x 13 1048 x 950 x 330 Net Weight Lbs / kg 189 / 86 External Finish Munsell No. 3Y 7.8/11 Refrigerant Pipe Size O.D. ― Eight Ports Liquid (High Pressure)In / mm 1/4 / 6.35 Gas (Low Pressure)A:1/2 / 12.7 ; B,C: 3/8 / 9.52 Max. Refrigerant Line Length Ft / m 230 / 70 Max. Piping Length for Each Indoor Unit Ft / m 82 / 25 Max. Refrigerant Pipe Height Difference If IDU is Above ODU Ft / m 49 / 15 If IDU is Below ODU 49 / 15 Connection Method Flared/Flared Refrigerant R410A (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Outdoor Unit: MXZ-3C30NAHZ2 * Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / W.B. 23.9° C (75° F) Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F | Indoor: 70º F (21º C) DB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB HP-1-2 03/27/2019 Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. Notes: SPECIFICATIONS: MXZ-3C30NAHZ2, contd. Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Non-ducted (06 + 06 + 09)18.0 12.5 11.0 4.00 2.65 Ducted and Non-ducted 17.00 11.40 10.40 3.85 2.58 Ducted (09 + 09 + 09)16.0 10.3 9.8 3.70 2.50 Outdoor Cooling D.B. 14 to 115° F [ D.B. −10 to 46° C]*1 Heating W.B. -13 to 65° F [ W.B. −25 to 18° C ] *1. D.B. 5 to 115° F [ D.B. −15 to 46° C ], when an optional Air Outlet Guide is installed. • Minimum of two Indoor Units must be connected to the MXZ-3C30NAHZ2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130% of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. • Only 1 MVZ may be used on any system. • When an MVZ is connected, total connected capacity must be 100% or less. • When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). ENERGY EFFICIENCIES: NOTES: OPERATING RANGE: MVZ CONNECTION RULES: 03/27/2019 Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. MXZ-3C30NAHZ2 OPERATIONAL PERFORMANCE NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 1 6 6,000 6 6,000 - - 7,400 7,400 - - 1 9 9,000 9 9,000 - - 11,000 11,000 - - 1 12 12,000 12 12,000 - - 14,400 14,400 - - 1 15 14,000 15 14,000 - - 18,000 18,000 - - 1 18 17,200 18 17,200 - - 21,600 21,600 - - 1 24 22,500 24 22,500 - - 22,600 22,600 - - 2 12 12,000 6 + 6 6,000 6,000 - 14,800 7,400 7,400 - 2 15 15,000 6 + 9 6,000 9,000 - 18,400 7,400 11,000 - 2 18 18,000 6 + 12 6,000 12,000 - 22,000 7,500 14,500 - 2 21 20,000 6 + 15 6,000 14,000 - 22,000 6,400 15,600 - 2 24 23,000 6 + 18 5,900 17,100 - 23,000 5,900 17,100 - 2 30 24,000 6 + 24 5,100 18,900 - 24,000 5,900 18,100 - 2 18 18,000 9 + 9 9,000 9,000 - 22,000 11,000 11,000 - 2 21 20,000 9 + 12 8,600 11,400 - 22,000 9,500 12,500 - 2 24 23,000 9 + 15 9,000 14,000 - 23,000 8,700 14,300 - 2 27 24,000 9 + 18 8,200 15,800 - 24,000 8,100 15,900 - 2 33 24,000 9 + 24 6,900 17,100 - 24,000 7,900 16,100 - 2 24 23,000 12 + 12 11,500 11,500 - 23,000 11,500 11,500 - 2 27 24,000 12 + 15 11,100 12,900 - 24,000 10,700 13,300 - 2 30 24,000 12 + 18 9,900 14,100 - 24,000 9,600 14,400 - 2 36 24,000 12 + 24 8,300 15,700 - 24,000 9,300 14,700 - 2 30 24,000 15 + 15 12,000 12,000 - 24,000 12,000 12,000 - 2 33 24,000 15 + 18 10,800 13,200 - 24,000 10,900 13,100 - 2 36 24,000 18 + 18 12,000 12,000 - 24,000 12,000 12,000 - 3 18 18,000 6 + 6 + 6 6,000 6,000 6,000 22,000 7,300 7,300 7,300 3 21 21,000 6 + 6 + 9 6,000 6,000 9,000 25,800 7,400 7,400 11,000 3 24 24,000 6 + 6 + 12 6,000 6,000 12,000 28,400 7,200 7,200 14,000 3 27 26,000 6 + 6 + 15 6,000 6,000 14,000 28,400 6,400 6,400 15,600 3 30 28,400 6 + 6 + 18 5,800 5,800 16,700 28,600 5,800 5,800 17,000 3 36 28,400 6 + 6 + 24 4,900 4,900 18,500 28,600 5,700 5,700 17,300 03/27/2019 Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. MXZ-3C30NAHZ2 OPERATIONAL PERFORMANCE, contd. # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 3 24 24,000 6 + 9 + 9 6,000 9,000 9,000 28,400 7,100 10,600 10,600 3 27 28,400 6 + 9 + 12 6,300 9,500 12,600 28,400 6,400 9,500 12,500 3 30 28,400 6 + 9 + 15 5,900 8,800 13,700 28,600 5,800 8,600 14,100 3 33 28,400 6 + 9 + 18 5,300 7,900 15,200 28,600 5,300 7,900 15,400 3 30 28,400 6 + 12 + 12 5,700 11,400 11,400 28,600 5,800 11,400 11,400 3 33 28,400 6 + 12 + 15 5,300 10,700 12,400 28,600 5,300 10,300 12,900 3 36 28,400 6 + 12 + 18 4,800 9,700 13,900 28,600 4,900 9,500 14,200 3 36 28,400 6 + 15 + 15 5,000 11,700 11,700 28,600 4,900 11,900 11,900 3 27 28,400 9 + 9 + 9 9,500 9,500 9,500 28,400 9,500 9,500 9,500 3 30 28,400 9 + 9 + 12 8,500 8,500 11,400 28,600 8,600 8,600 11,300 3 33 28,400 9 + 9 + 15 8,000 8,000 12,400 28,600 7,900 7,900 12,900 3 36 28,400 9 + 9 + 18 7,300 7,300 13,900 28,600 7,200 7,200 14,200 3 33 28,400 9 + 12 + 12 7,700 10,300 10,300 28,600 7,900 10,300 10,300 3 36 28,400 9 + 12 + 15 7,300 9,700 11,400 28,600 7,200 9,500 11,900 3 36 28,400 12 + 12 + 12 9,500 9,500 9,500 28,600 9,500 9,500 9,500 NON-DUCTED: 03/27/2019 Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. MXZ-3C30NAHZ2 OPERATIONAL PERFORMANCE, contd. DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 1 9 9,000 9 9,000 - - 10,900 10,900 - - 1 12 12,000 12 12,000 - - 13,600 13,600 - - 1 15 15,000 15 15,000 - - 18,000 18,000 - - 1 18 17,200 18 17,200 - - 21,600 21,600 - - 1 24 22,600 24 22,600 - - 24,000 24,000 - - 2 18 18,000 9 + 9 9,000 9,000 - 21,800 10,900 10,900 - 2 21 21,000 9 + 12 9,000 12,000 - 22,800 10,100 12,700 - 2 24 24,000 9 + 15 9,000 15,000 - 24,000 9,100 14,900 - 2 27 24,000 9 + 18 8,200 15,800 - 24,000 8,000 16,000 - 2 33 24,000 9 + 24 6,800 17,200 - 24,000 7,500 16,500 - 2 24 24,000 12 + 12 12,000 12,000 - 24,000 12,000 12,000 - 2 27 24,000 12 + 15 10,700 13,300 - 24,000 10,300 13,700 - 2 30 24,000 12 + 18 9,900 14,100 - 24,000 9,300 14,700 - 2 36 24,000 12 + 24 8,300 15,700 - 24,000 8,700 15,300 - 2 30 24,000 15 + 15 12,000 12,000 - 24,000 12,000 12,000 - 2 33 24,000 15 + 18 11,200 12,800 - 24,000 10,900 13,100 - 2 36 24,000 18 + 18 12,000 12,000 - 24,000 12,000 12,000 - 3 27 27,000 9 + 9 + 9 9,000 9,000 9,000 27,400 9,100 9,100 9,100 3 30 27,400 9 + 9 + 12 8,200 8,200 11,000 27,600 8,500 8,500 10,600 3 33 27,400 9 + 9 + 15 7,500 7,500 12,500 27,600 7,600 7,600 12,500 3 33 27,400 9 + 12 + 12 7,500 10,000 10,000 27,600 7,900 9,900 9,900 3 36 27,400 12 + 12 + 12 9,100 9,100 9,100 27,600 9,200 9,200 9,200 3 36 27,400 9 + 9 + 18 7,000 7,000 13,400 27,600 6,900 6,900 13,700 3 36 27,400 9 + 12 + 15 6,900 9,100 11,400 27,600 7,100 8,800 11,700 03/27/2019 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc. DIMENSIONS: MXZ-3C30NAHZ2 FORM# MXZ-3C30NAHZ2 for Multiple Indoor Unit Styles - 201712 Unit: inch (mm) 11 MXZ-3C24NAHZ MXZ-3C30NAHZ Unit: inch (mm) Lock nut Conduit connector Conduit plate Under Conduit plate Top OBH702 03/27/2019 P-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: ACCESSORIES: Indoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Relay Kit (CN24RELAY-KIT-CM3) □Fan Speed Indication Adapter (PAC-735) □Humidifier Control Relay (PAC-740) Outdoor Unit □Air Outlet Guide (PAC-SG59SG-E [x2]) □Wind Baffle (WB-PA2 [x2])*Allows operation to 0º F (-18º C). □Mounting Base (QSMS1202) □Wall Bracket (QSWB2000M-1) Controls □Wireless Controller (MHK1) □Advanced Wired Controller (PAR-31MAA) □Simple Wired Controller (PAC-YT53CRAU) □M-NET Adapter (PAC-SF83MA-E) □Temperature Sensor (PAC-SE41TS) SPECIFICATIONS: Rated Conditions (Capacity / Input)* Cooling1 Btu/h / W 34,000 / 2,780 Heating at 47º F2 Btu/h / W 38,000 / 3,040 Heating at 17o F3 Btu/h / W 29,100 / 3,230 Capacity Range Minimum Maximum Cooling1 Btu/h 18,000 36,000 Heating at 47º F2 Btu/h 18,000 40,000 Heating at 17o F3 Btu/h -38,000 Heating at 5º F4 Btu/h -38,000 1. Cooling | Indoor: 80º F(27º C)DB / 67º F(19º C)WB; Outdoor: 95º F(35º C)DB / 75º F (24º C)WB* 2. Heating at 47ºF | Indoor: 70º F(21º C)DB / 60º F(16º C)WB; Outdoor: 47º F(8º C)DB / 43º F(6º C)WB* 3. Heating at 17º F | Indoor: 70º F(21º C)DB / 60º F(16º C)WB; Outdoor: 17º F(-8º C)DB / 15º F(-9º C)WB* 4. Heating at 5º F | Indoor: 70º F(21º C)DB / 60º F(16º C)WB; Outdoor: 5º F(-15º C) DB / 5º F(-15º C)WB * Rating Conditions per AHRI Standard Operating Range Cooling 0º F** to 115º F (-18º C to 46º C) DB Heating -13º F to 70º F (-25º C to 21º C) DB ** With optional wind baffle accessory installed. If not installed, the min. temp. will be 23º F (-5º C) DB. AHRI Efficiency Ratings EER 12.2 SEER 17.8 HSPF 11.0 COP at 47o F 3.48 COP at 17o F 2.62 Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz Minimum Circuit Ampacity (MCA) Indoor / Outdoor A 5.50 / 28 Indoor Unit Blower Motor (ECM)F.L.A.4.4 Blower Motor Output W 430 External Static Pressure In. WG 0.30 - 0.50 - 0.80 SHF / Moisture Removal 0.74 / 7.9 pt./h Outdoor Unit Compressor INVERTER Fan Motor (ECM)F.L.A.0.4+0.4 MOCP A 40 Airflow Rate Indoor (Lo-Mid-Hi) Cooling DRY: CFM 788-956-1125 Heating 788-956-1125 Outdoor 3,530 Sound Pressure Level Indoor (Lo-Mid-Hi) Cooling dB(A) 32-36-40 Heating 32-36-40 Outdoor Cooling 52 Heating 53 External Dimensions Indoor (H x W x D) In.(mm) 59-1/2 x 25 x 21-5/8 (1,511 x 635 x 548) Outdoor (H x W x D)53-1/8 x 37-3/8 x 13 + 1-3/16 (1,350 x 950 x 330 + 30) Net Weight Indoor Lbs.(kg)172 (78) Outdoor 265 (120) External Finish Indoor High-gloss polyester powder coated Outdoor Munsell No. 3Y 7.8 / 1.1 Refrigerant R410A ; 12lbs. Refrigerant Piping (Flared) Liquid (High Pressure)In.(mm)5/8 (15.88) Gas (Low Pressure)3/8 (9.52) Maximim Total Refrigerant Pipe Length Ft. (m)245 (75) Maximum Vertical Separation Ft. (m)100 (30) PVA-A36AA4 & PUZ-HA36NHA4 36,000 BTU/H MULTI-POSITION AIR HANDLER HYPER HEAT-PUMP SYSTEM Indoor Unit: PVA-A36AA4 Outdoor Unit: PUZ-HA36NHA4 FC-3, HP-3 03/27/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.comUnit : mm<inch>Min. 1000mm<39-3/8>Min. 150mm<5-29/32>Min. 10mm<3/8>Min. 10mm<3/8>FREE<Foundation bolt height>FOUNDATIONService spaceTerminal BlockLeft···Power supply wiringRight····Indoor/Outdoor wiringEarth terminalService panelHandle1223<29/32> 1076<42-3/8> * 1 447<17-19/32> * 1 443<17-7/16>HandleFront piping coverRear piping coverAir DischargeRear Air IntakeSide Air Intake31<1-7/32>145<5-23/32>145<5-23/32>220<8-21/32>30<1-3/16>145<5-23/32>81<3-3/16>219<8-5/8> 71<2-13/16>71<2-13/16>Bottom piping hole(Knockout)Drain hole5-33<1-5/16>HandleSide Air IntakeAir intakeRear Air IntakeHandleHandle40<1-9/16>74<2-19/32>When installing the conduit.Set the attachment to the inner side of each panel.2-22.2<7/8>1/2 Conduit attachment45<1-25/32>40<1-9/16>65<2-9/16>92<3-5/8>27<1-1/16>55<2-3/16> 23<29/32>73<2-7/8> 63<2-1/2>Rear piping hole(Knockout)Rear trunking hole(Knockout)Conduit hole (2-27<1-1/16>Knockout)92<3-5/8>19<3/4>55<2-3/16>92<3-5/8>75<2-31/32>40<1-9/16>73<2-7/8>63<2-1/2> 23<29/32>27<1-1/16> 92<3-5/8>Right piping hole(Knockout)Right trunking hole(Knockout)Conduit hole (2-27<1-1/16>Knockout)92<3-5/8>92<3-5/8>65<2-9/16>45<1-25/32>40<1-9/16>27<1-1/16>55<2-3/16> 23<29/32>73<2-7/8> 63<2-1/2>Front piping hole(Knockout)Front trunking hole(Knockout)Conduit hole (2-27<1-1/16>Knockout)92<3-5/8>371<14-19/32> 330<13>30<1-3/16>175<6-7/8>600<23-5/8>175<6-7/8>42<1-21/32>66<2-5/8>950<37-13/32>322<12-11/16>1350<53-5/32> 635<25> 19<3/4> 417<16-13/32> 370<14-9/16>2-U Shaped notched hole(Foundation Bolt M10<W3/8>)56<2-7/32> 28<1-3/32> 53<2-3/32> 45<1-25/32>2-1236 Oval hole(Foundation Bolt M10<W3/8>)····Refrigerant GAS pipe connction (FLARE)15.88<5/8>····Refrigerant LIQUID pipe connection (FLARE) 9.52<3/8>*1 ····Indication of STOP VALVE connection location.Example of Notes1 FREE SPACE (Around the unit)2 SERVICE SPACE3 FOUNDATION BOLTS4 PIPING-WIRING DIRECTIONSPiping Knockout Hole DetailsThe diagram below shows abasic example.Explantion of particular details aregiven in the installation manuals etc.Dimensions of space neededfor service access areshown in the below diagram.Please secure the unit firmlywith 4 foundation (M10<W3/8>)bolts. (Bolts and washers mustbe purchased locally.)Piping and wiring connectionscan be made from 4 directions:front, right, rear and below.Min.10mm<3/8>Min.500mm<19-11/16>Min.500mm<19-11/16>Min.150mm<5-29/32> Min.30mm<1-3/16> DIMENSIONS: PVA-A36AA4 & PUZ-HA36NHA4 PVA-A36AA4 PUZ-HA36NHA4 FORM# PVA-A36AA4 - PUZ-HA36NHA4 - 201602Ver2 Unit: mm (inch) Unit: mm (inch) 03/27/2019 Job Name: System Reference:Date: GENERAL FEATURES •208/240V Electric Heat Kits • Mounts directly to the air outlet connection of the multi-position air handler CAUTION •Do not power the electric heat kit from the outdoor unit. • A separate power supply must be provided. • Air handler must be set on non-combustible floor when using electric heat in the downflow configuration. • Maximum external static pressure of 0.60 in WG for all installations with electric heaters. For more details, see note on best design practice on page 4. ACCESSORIES Separate Power Kit for MVZ, SVZ and PVA models This kit allows the installer to connect power from a source other than the outdoor unit to the air handler. (S2 & S3 still must connect from outdoor unit for communication) □ SPTB1 Auxiliary Heat Lockout for MVZ, SVZ and PVA models This option prevents the electric heat kit from operating above a set outside temperature. □ ETC-211000-MIT Replacement Temp Probe for ETC-211000-MIT □ 1309007-044 OPTIONAL ELECTRIC HEAT KIT FOR MULTI-POSITION AIR HANDLER USE WITH: PVFY-P-NAMU-E/E1; MVZ-A-AA4/7; SVZ-KP-NA; PVA-A-AA4/7 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. FC-3HE 03/27/2019 (See note on best design practice on page 4) NOTE No other combination approved. MODEL PER OUTDOOR UNIT EH03-MPA-S(B)EH05-MPA-S(B)EH08-MPA-S(B)EH03-SVZ-SEH05-SVZ-SEH08-SVZ-SEH03-MPA-M(B)EH05-MPA-M(B)EH08-MPA-M(B)EH10-MPA-M(B)EH10-MPA-L(B)EH15-MPAS-L(B)EH17-MPAS-L(B)354+4354+4354+45+55+57.5+7.58.75+8.75PVFY-P12NAMU-E PVFY-P12NAMU-E1 PVFY-P18NAMU-E PVFY-P18NAMU-E1 PVFY-P24NAMU-E PVFY-P24NAMU-E1 PVFY-P30NAMU-E PVFY-P30NAMU-E1 PVFY-P36NAMU-E PVFY-P36NAMU-E1 PVFY-P48NAMU-E PVFY-P48NAMU-E1 PVFY-P54NAMU-E PVFY-P54NAMU-E1 MVZ-A12AA4 MVZ-A12AA7 MVZ-A18AA4 MVZ-A18AA7 MVZ-A24AA4 MVZ-A24AA7 MVZ-A30AA4 MVZ-A30AA7 MVZ-A36AA4 MVZ-A36AA7 SVZ-KP12NA ○○ SVZ-KP18NA ○○ ○ PVA-A12AA7 ○○ PVA-A18AA7 ○○ ○ PVA-A24AA7 ○○ ○ ○ PVA-A30AA4 PVA-A30AA7 PVA-A36AA4 PVA-A36AA7 PVA-A42AA4 PVA-A42AA7 Electric Heat Kit Air Handler Model Stages (1st + 2nd) ○○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○○○ ○ ○ ○ ○ ○ ○ ○○ ○ ○ ○ ○ ○ AVAILABLE COMBINATIONS: ELECTRIC HEAT KIT Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. 03/27/2019 (See note on best design practice on page 4) Electric Heat Part Number Heater kW Heater Amps1 MCA1 MOP1 Htr & Mtr Amps2 MCA2 MOP2 Factory Installed Circuit Breaker208V/240V 208V/240V 208V/240V 208V/240V 208V/240V 208V/240V 208V/240V EH03-SVZ-S 2.3/3.0 10.8/12.5 13.5/15.6 15/20 13.2/14.9 16.5/18.6 20/20 20 EH05-SVZ-S 3.8/5.0 18.1/20.8 22.6/26 25/30 20.5/23.2 25.6/29 30/30 30 EH08-SVZ-S 6.0/8.0 28.9/33.3 36.1/41.7 40/45 31.3/35.7 39.1/44.7 40/45 45 EH03-MPA-S(B)2.3/3.0 10.8/12.5 13.5/15.6 15/20 13.2/14.9 16.5/18.6 20/20 20 EH05-MPA-S(B)3.8/5.0 18.1/20.8 22.6/26 25/30 20.5/23.2 25.6/29 30/30 30 EH08-MPA-S(B)6.0/8.0 28.9/33.3 36.1/41.7 40/45 31.3/35.7 39.1/44.7 40/45 45 EH03-MPA-M(B)2.3/3.0 10.8/12.5 13.5/15.6 15/20 14.1/15.8 17.7/19.8 20/20 20 EH05-MPA-M(B)3.8/5.0 18.1/20.8 22.6/26 25/30 21.4/24.1 26.7/30.2 30/30 30 EH08-MPA-M(B)6.0/8.0 28.9/33.3 36.1/41.7 40/45 32.2/36.6 40.2/45.8 45/50 50 EH10-MPA-M(B)7.5/10 36.1/41.7 45.1/52.1 50/60 39.4/45 49.3/56.2 50/60 60 EH10-MPA-L(B)7.5/10 36.1/41.7 45.1/52.1 50/60 40.6/46.2 50.8/57.7 60/60 60 EH15-MPAS-L(B)11.3/15 Circuit 1 27.1/31.2 33.9/39.1 35/40 31.6/35.8 39.5/44.7 40/45 45 Circuit 2 27.1/31.2 33.9/39.1 35/40 27.1/31.2 33.9/39.1 35/40 40 EH17-MPAS-L(B)13.2/17.5 Circuit 1 31.6/36.5 39.5/45.6 40/50 36.1/41 45.1/51.2 45/60 60 Circuit 2 31.6/36.5 39.5/45.6 40/50 31.6/36.5 39.5/45.6 40/50 50 1 Heater amps; no motor 2 Heater and motor amps (connect air handler power supply to largest circuit breaker) 60Hz Motor amps are placed on circuit 1 when required Unit tested at 0.60 in WG external static pressure Minimum installation clearance to combustible material 0" Maximum outlet air temperature 200° F ELECTRICAL SPECIFICATIONS: ELECTRIC HEAT KIT Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. 03/27/2019 Units: mm (in.) A B (DUCT)541.8(21-1/4)68(2-5/8)139.3 (5-1/2)403.6 (15-7/8) (DUCT)29 (1-1/8)116.1(4-9/16)77.8 (3) 50 (2) 77.8 (3)50(2)40.8 (1-5/8) 50 (2)41.8(1-5/8)151.6 (6)24 (1) FRONT VIEW CIRCUIT BREAKER(S) TOP VIEW LEFT SIDE VIEW 42ø & 35ø KNOCKOUT TYP. 3 LINE VOLTAGE 28.6ø & 22ø KNOCKOUT TYP. 4 LINE VOLTAGE RIGHT SIDE VIEW MODEL A B EH03-MPA-S(B) 433 (17) 376 (14-13/16) EH05-MPA-S(B) EH08-MPA-S(B) EH03-SVZ-S EH05-SVZ-S EH08-SVZ-S EH03-MPA-M(B) 534 (21)477 (18-13/16) EH05-MPA-M(B) EH08-MPA-M(B) EH10-MPA-M(B) EH10-MPA-L(B) 635 (25) 579 (22-13/16)EH15-MPAS-L(B) EH17-MPAS-L(B) NOTE BEST DESIGN PRACTICE TO ASSURE ADEQUATE AIRFLOW REQUIREMENTS During electric heater operation the fan is defaulted to high speed to help assure adequate airflow. To maintain adequate airflow required for electric heater operation, it is recommended that an additional 0.20 WG static pressure drop be added to system ductwork design when using the electric heat kit. Examples: When air handler is set for 0.50 WG static, the maximum external static pressure for ductwork should not exceed 0.30 WG. When air handler is set for 0.80 WG static, the maximum external static pressure for ductwork should not exceed 0.60 WG, etc. FORM# OPTIONAL ELECTRIC HEAT KIT FOR MULTI-POSITION AIR HANDLER - 201804 Manufactured for MITSUBISHI ELECTRIC US, INC. 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: ELECTRIC HEAT KIT Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. 03/27/2019 REG-A 03/27/2019 REG -B 03/27/2019 Specification Submittal Data / Panasonic Ventilation Fan Description: Ventilating fan shall be Low Noise ceiling or wall mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilation Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed DC brushless ECM motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 50-80-100 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when GFCI protected and used in insulated ceiling (TYPE I.C.). • PCB board equipped with thermal–cutoff fuse. • Removable with permanently lubricated plug- in motor. Housing: • 26 gauge galvanized steel body. • Built-in 4" Oval duct collar. Also compatible with 4" round duct. • Optional 24 gauge steel, fire code rated 4" oval to 3" round duct adaptor sold separately (Model # FV-VS43R). • Built in backdraft damper. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Unique L-shaped bracket simplifies installation and provides strong support. Ceiling Radiation Damper: • WhisperValue DC is UL listed for use with the Panasonic Ceiling Radiation Damper (Model #: PC-RD05C5, sold separately). Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. Warranty: • DC Motor: 6 Years from original purchase date. • ALL Parts: 3 Years from original purchase date. Architectural Specifications: Ventilation fan shall be UL and cUL listed for ceiling or wall mount and tub/shower enclosure when GFCI protected. Fan shall also be ENERGY STAR® certified, with a built-in speed selector. Choose from 50-80-100 CFM and no more than <0.3/0.4/0.9 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 53/81/100 CFM and no more than 0.5/0.8/1.3 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 4.4/7.2/11.1 watts at 0.1 w.g. and 7.5/11.5/16.0 watts at 0.25 w.g., with efficiency of no less than 12.8/11.4/9.2 CFM/watt at 0.1 w.g. and 7.9/7.2/6.4 CFM/watt at 0.25 w.g. The motor shall be totally enclosed with a brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be FV-0510VS1 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: FV-0510VS1 13″ 10-1 / 4 ″ 3-3/8″ 5″ 2-9/16″ 10-1/4 ″13 ″4″oval duct FV-0510VS1 4" Oval duct VF16549SS0517 Performance Curve 4" Oval ductFV-0510VS1 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0 20 40 60 80 100 FV-0510VS14" duct/50 CFM FV-0510VS14" duct/80 CFM FV-0510VS14" duct/100 CFM 4" 20ft duct 4" 40ft duct 4" 60ft duct 4" 80ft duct 4" 100ft ductStatic Pressure (inch w.g.)Airflow (CFM) Specifications: WhisperValueDC FV-0510VS1 4" Oval 4" Oval 4" Oval Ventilation Fan Characteristics (HVI Certified Data) Static Pressure in inches w.g.0.1 0.25 0.1 0.25 0.1 0.25 Air Volume (CFM)100 100 80 81 50 53 Noise (sones)0.9 1.3 0.4 0.8 <0.3 0.5 Power Consumption (watts)11.1 16.0 7.2 11.5 4.4 7.5 Energy Efficiency (CFM/Watt)9.2 6.4 11.4 7.2 12.8 7.9 Speed (RPM)902 1121 797 1070 708 1025 Current (amps)0.20 0.27 0.13 0.20 0.09 0.14 MAX. Current (amps)0.39 Power Rating (V/Hz)120/60 ENERGY STAR rated YES Housing Can Motor/Grille Assembly Complete Fan Unit Master Pack FV-0510VSA1 FV-0510VSB1 FV-0510VS1 4 0.25=Installed Performance Static Pressure (inch w.g.)Airflow (CFM) 120V/60Hz. Duct diameter shall be no less than 4". Optional 24 gauge steel, fire code rated 4" oval to 3" round duct adaptor sold separately (Model # FV-VS43R). Fan can be used to comply with ASHRAE 62.2, LEED, EarthCraft, California Title-24 and WA Ventilation Code. ECM Motor Technology When the fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the fan to perform as rated. WhisperValue Contractor Pack* The Contractor Pack includes four complete fans. The housing and motor/grille are packaged separately for flexibility during installation. *Must order in quantities of 4. Shipment will contain 1 box with 4 units. EF-1 03/27/2019 FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM BR-SERIES5 Specifications may be subject to change without notice. INDOOR UNIT Duct Mounted or Thru-the-Wall SPECIFICATIONS Ventilation Type: Static plate, heat and humidity transfer Typical Airflow Range: 50-140 CFM Standard Features: Painted cabinet Line-cord power supply Built-in control Unit may be mounted in any orientation Control: Built-in proportional runtime control and switched terminals for furnace/AC interconnect Filters: Total qty. 2, MERV 8, spun-polyester media: 10 1/2" x 10 1/2" x 1" Unit Dimensions & Weight: 33 1/2" L x 19 1/4" W x 13 1/2" H 48 lbs. Max. Shipping Dimensions & Weight (in carton): 32" L x 22" W x 18" H 60 lbs. Motor(s): Qty. 1, Double-shaft standard motor Accessories: Backdraft damper 6" Wall cap 6" - white, brown Exterior thru-the-wall installation kit Duct collar kit UNIT DIMENSIONS UNIT MOUNTING & APPLICATION Can be mounted in any orientation. If duct-mounted, airstreams cannot be switched. If mounted with exterior Thru-the-wall installation kit, the RA/EA airstreams are switched with the OA/FA airstreams. If four ducts are connected using duct collar kit, airstreams may be switched. AIRFLOW CONFIGURATION Available as shown in dimension drawing. 30 7/8" Overall 33 1/4" Overall(with Duct Collars) 28 7/8" Case 20 3/8" 2 1/8" 5 3/4" 1 1/8" EA (TW) FA (DH) OA (TW) RA (DH) Cut Hole in Duct (Minimum Size) 36" Line Cord 2 1/4" Typ. CL 4 5/8" CL 6 1/8" FA (TW)EA (DH)EA (TW)FA (DH)RA (TW)OA (DH)OA (TW)RA (DH) CL 5 1/8" 13 3/8"Case13 3/8"Overall18 1/2" MinimumService Area 18 1/8"MinimumService AreaDoor Swing 24V AC Control Terminal Proportional Runtime Control 6" Typ. 8" Typ. 18 1/8" Case CL 4 1/2" 19 1/8" Overall 1/2" 5/8" LEFT VIEW TOP VIEW FRONT VIEW RIGHT VIEW Model: BR130Drawing Type: Unit DimensionVersion: MAR16 ABBREVIATIONSEA: Exhaust Air to outsideOA: Outside Air intakeRA: Room Air to be exhaustedFA: Fresh Air to insideTW: Thru WallDH: Duct Hung INSTALLATION ORIENTATIONUnit may be installed in anyorientation. NOTE1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE ROUNDED TO THENEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECTTO CHANGE WITHOUT NOTICE. ELECTRICAL DATA HP Volts HZ Phase Input Watts FLA 0.1 120 60 Single 121 @ 124 CFM 1.3 UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H20 Temp EFF%Total EFF% Winter/Summer* 52 0.70 82 78/65 69 0.60 80 75/62 94 0.50 76 71/57 113 0.40 74 68/53 132 0.30 71 65/49 141 0.20 70 63/47 148 0.10 69 62/46 * See HVI certification ratings on page 164 of RenewAire’s Full Line Volume XVIII Catalog. Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on the BR130. 130BR Energy Recovery Ventilator Standard Download specification at: renewaire.com/specifications ERV-1 03/27/2019