HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0071.2018 (11).ACBKStructural Plan Review July 3, 2018 Review/Report is based on structural Construction Documents prepared by Lindauer-Dunn, Inc., Structural Engineers, dated 05/09/2018 (100% CD) and architectural drawings prepared by Chamberlin Architects, dated 05/09/2018 and received via electronic transfer on 06/20/2018. Structural drawings are stamped and signed by the engineer of record. Project Name: Aspen Ambulance District Facility Project Location: 401 Castle Creek Road, Aspen, CO 81611 Review based on International Building Code (IBC) Edition: 2015 Building Construction Type: Structure consists of metal deck on steel joists and beams at the roof level with a structural concrete slab on metal decking supported by steel joists and beams at the upper level. The lower level ambulance apparatus bays and classroom areas floor system is a concrete slab on grade. Foundation system is concrete foundation walls and footings. Lateral system consists of structural steel braced frames. Building Department Jurisdiction: Aspen Building Department Risk Category: IV (IBC 2015 Table 1604.5) Basic Wind Speed: 120 mph (ultimate) Exposure: B Seismic Site Class: D Importance Factor: Ie = 1.5 Snow Load: 75 psf uniform Ground Snow Load: 100 psf Importance Factor: Is = 1.2 Frost Depth: 36” Structural Review Comments: 1. Sheet S-100 General Notes: Please provide soils report referenced in the general notes for review. P a g e | 2 2. Sheet S-100 Entry Canopy Framing Plan: The column sizes for the canopy support framing do not appear to be noted on plan. Please provide. 3. Sheet S-103 Upper Floor Framing Plan: The lateral loads being transferred into Braced Frame #1 at the elevator/stair openings appear to be very high. Please provide calculations and details that indicate how these lateral loads are transferred into the braced frame without a floor diaphragm. 4. Sheet S-202 Braced Frame Details/Elevations: The overturning forces at Braced Frame #1 and #6 appear to be very high. Please provide calculations that indicate the standard anchor bolt with standard hook only as detailed on A/S203 is adequate to resist the overturning loads. Plan Review by: Dan C. Donegon, P.E. HCDA Engineering, Inc. (719) 633-7784 ddonegon@hcdaengineering.com Final Report Review and Local Contact: Thomas R. Thompson, CBO and ICC Certified Plans Examiner Sunrise Engineering 4261 Garrison Street Wheat Ridge, Co. 80033-3023 Cell (303) 328-1546 Home (303) 422-7808 E-mail tthompson@sunrise-eng.com