Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0071.2018 (15).ACBKCOMcheck Software Version 4.3.5.1 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0071.2018.ACBK Vertical Glazing / Wall Area:14% Location:Aspen, Colorado Climate Zone:7 Construction Site: 405 Castle Creek rd. Aspen, Colorado 81611 Owner/Agent: Aspen Ambulance District Facility Designer/Contractor: Chamberlin Architects. Studio B aspen, Colorado 81611 kevin@studiobarchitects.net Project Information Energy Code: COMCHECK whole building High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Building Area Floor Area 1-Fire Station : Nonresidential 3729 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Fire Station]2761 ---57.0 0.017 0.028 Floor: Unheated Slab-On-Grade, Horizontal with vertical >= 4 ft., [Bldg. Use 1 - Fire Station] (c) 452 ---10.0 0.360 0.520 roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Fire Station]3232 ---57.0 0.017 0.028 NORTH Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Fire Station]2953 19.0 15.0 0.041 0.064 Door: Insulated Metal, Non-Swinging, [Bldg. Use 1 - Fire Station]904 ------0.057 0.057 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID product label, SHGC 0.25, [Bldg. Use 1 - Fire Station] (b) 447 ------0.290 0.290 Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Fire Station]1163 19.0 15.0 0.041 0.064 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID f, SHGC 0.25, [Bldg. Use 1 - Fire Station] (b) 322 ------0.290 0.290 EAST Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Fire Station]1643 19.0 15.0 0.041 0.064 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID f, SHGC 0.25, [Bldg. Use 1 - Fire Station] (b) 306 ------0.290 0.290 SOUTH Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Fire Station]2523 19.0 15.0 0.041 0.064 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID f, SHGC 0.25, [Bldg. Use 1 - Fire Station] (b) 112 ------0.290 0.290 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Fire Station]40 ------0.097 0.370 Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Fire Station]671 19.0 15.0 0.041 0.064 Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 121 ofPage 08/21/2018 08/21/2018 COMcheck Software Version 4.3.5.1 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0071.2018.ACBK Construction Site: 405 Castle Creek rd. Aspen, Colorado 81611 Owner/Agent: Aspen Ambulance District Facility Designer/Contractor: Chamberlin Architects. Studio B aspen, Colorado 81611 kevin@studiobarchitects.net Project Information Energy Code: COMCHECK whole building High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Allowed Interior Lighting Power Proposed Interior Lighting Power Interior Lighting TBD: No lighting fixtures specified Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 123 ofPage 08/21/2018 COMcheck Software Version 4.3.5.1 Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0071.2018.ACBK Construction Site: 405 Castle Creek rd. Aspen, Colorado 81611 Owner/Agent: Aspen Ambulance District Facility Designer/Contractor: Chamberlin Architects. Studio B aspen, Colorado 81611 kevin@studiobarchitects.net Project Information Energy Code: COMCHECK whole building 0 (Unspecified)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / D Tradable Wattage E Allowed Watts (B X C) Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 0 0 500 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 500 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Exterior lighting zone not specified (see project screen) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 124 ofPage 08/21/2018 COMcheck Software Version 4.3.5.1 Mechanical Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0071.2018.ACBK Location:Aspen, Colorado Climate Zone:7 Construction Site: 405 Castle Creek rd. Aspen, Colorado 81611 Owner/Agent: Aspen Ambulance District Facility Designer/Contractor: Chamberlin Architects. Studio B aspen, Colorado 81611 kevin@studiobarchitects.net Project Information Energy Code: COMCHECK whole building High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.3.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 125 ofPage 08/21/2018 Inspection Checklist Requirements: 78.0% were addressed directly in the COMcheck software COMcheck Software Version 4.3.5.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable Requirement will be met. C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 126 ofPage 08/21/2018 Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.5 [FO3]2 Slab edge insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 127 ofPage 08/21/2018 Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 128 ofPage 08/21/2018 Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable C402.5.5, C403.2.4. 3 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 129 ofPage 08/21/2018 Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.1.3 [IN19]3 Non-swinging opaque doors have R- 4.75 insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable C402.2.3 [IN6]1 Above-grade wall insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.5 [IN8]2 Floor insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.2.2 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 1210 ofPage 08/21/2018 Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.5.3 [FI51]3 Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. Complies Does Not Not Observable Not Applicable Exception: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 1211 ofPage 08/21/2018 Project Title: Data filename: COMCHECK whole building 08/17/18Report date: 1212 ofPage 08/21/2018