HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (13).ACBK ARCHITECT: Chamberlin Architects, P.C. BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\ASI\ASI#005.1740.doc ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS OWNER ARCHITECT CONTRACTOR FIELD OTHER PROJECT: Aspen Ambulance District Facility OWNER: Pitkin County, CO TO: FCI Constructors, Inc. 3070 I-70 B, Bldg. A Grand Junction, CO 81504 ARCHITECT'S SUPPLEMENTAL INSTRUCTION NO: Five (5) ARCHITECT: Chamberlin Architects 437 Main Street Grand Junction, CO 81501 ARCHITECT'S PROJECT NO: 1740 DATE OF ISSUANCE: November 26, 2018 The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding in accordance with these instructions indicates your acknowledgment that there will be no change in the Contract Sum or Contract Time. Project Manual, Vol II Section 233100, part 2.7, item C.1.b, change to: b. If radius elbows are not possible or if rectangular elbows are used, provide single-thickness turning vanes with 2-inch vane radius and vanes spaced 1.5 inches apart. Double wall turning vanes shall not be acceptable due to high pressure drop. Section 233100, part 2.7 C: delete item 2.7.C.2. Drawings Sheet M101 – change location of pressure bypass duct and motorized damper for FR-2 to be as indicated on the attached Sketch MSK-3. Sheet M102 – delete pressure bypass duct and motorized damper for FR-2 from Mech/Elec 209 as indicated on the attached Sketch MSK-4. Sheet M102 – revise ductwork for FR-1 and FR-3 as indicated on the attached Sketch MSK-5. Attachments: MSK-3; MSK-4; MSK-5 -- 20"x20"x2O", — ___.----10"0. --%----_ � M j 1Y0 BYPASS D DRMPER 4"0,voB= MOOM 35CFM -_ 104 �pp0"REG /SP opo o c. aaisr "?� oy o C 0 28609 o% Z/14-/18 �sS�ONAL. EAG C X A M RR .. . N B . BYPASS DUCT AND DAMPER MSK -3 A R C M? Eo.0 i s RELOCATION o O ATION: no PROJECT: PROJEC' No: SCALE: DATE: PREPARED BY: y_$ ASPEN AMBUL 1740 3/16" = 1'-0" 11/23/2018 DCR M101 s 1 1 IVCH MU M � M j FR -3 FR2 0REG /Sl G RA r e ti -o 28609 9o��iz/lb/18, 4� SFS BONA.. C X A M R R .. . N B . BYPASS DUCT AND DAMPER € MSK -4 A R C M? Eo.0 i s RELOCATION o LOCATION: no PROJECT: PROJEC'No: SCALE: DATE: PREPARED 1: y_$ ASPEN AMBUL 1740 3/16" = 1'-0" 11/23/2018 DCR - M102 �yp0•RE�/sl G RAL Toy is C � 28609 y_$ RFs �ONAL 6�G? BY: 20"x18" OA 1740 1/4" = 1'-0" 2 ' c30" 30"x30"x2" FILTER RA DUCT FOR FILTER FR -3 21"x22" 20"z16' EA 0"x18' — 20"x18"OA 20"x18" EA 14"0 RA \\ 20'x18"OA 18'x20" DX COIL 30"x30"z2" FILTER 30"z30"x2" FILTER � DX COIL 20"x30' J J TRANSITION > FR -3 TRANSITION 20-A25" 20'x25" FR -1 18"x22" MA 16•x25" 16"x25" WA F PAD AT EACH CORNER, FR -2 ON SUPER W 20"x20" SA AND RA DX COIL WAFFLE PAD AT EACH CORNER, MASON SUPER W FURNACE SYSTEMS NORTH ELEVATION Ii 4' I 0' 8' C H A M R! R L 1 H DESCRIPTION • FR -1 AND FR -3 DUCTWORK REVISIONS MSK -5 A R C H I T E C T S � µw•duoo wwoci no LOCATION: PROJECT: PROJECT NO:� SCALE: DALE: PREPARED y_$ BY: ASPEN AMBUL 1740 1/4" = 1'-0" 11/23/2018 DCR M201