HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (23).ACBK ARCHITECT: Chamberlin Architects, P.C. BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#010.1740.doc PROPOSAL REQUEST FIELD OWNER ARCHITECT CONTRACTOR PROJECT: Aspen Ambulance District Facility OWNER: Pitkin County 123 Emma Road, Suite #106 Basalt, CO 81621 TO: FCI Constructors, Inc. 3070 I-70 Business Loop Building A Grand Junction, CO 81504 PROPOSAL REQUEST NO: Ten (10) DATE: September 25, 2018 ARCHITECT'S PROJECT NO: 1740 CONTRACT DATED: May 9, 2018 Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications to the Contract Documents described herein. THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED HEREIN. General: 1. All exterior handrails to be painted only (delete galvanizing) with the exception of the exterior stair at the NW corner of the building. This entire stair and handrail is to remain galvanized. Specifications: 2. Specification 03 3000, Cast-in-Place Concrete: Revise finish on site concrete walls from smooth form liner finish to sandblast finish. Monument wall to remain as smooth form liner finish. 3. Specification 10 1100 – Visual Display Units: Add paragraph 1.1.A.2:  Visual display board assemblies – field fabricated (tack boards) 4. Specification 10 1100 – Visual Display Units: Add paragraph 2.5: 2.5 VISUAL DISPLAY BOARD ASSEMBLY (field fabricated) A. Visual Display Board Assembly: Field fabricated. 1. Assembly: tackboard. 2. Corners: Square]. 3. Width and height: As indicated on Drawings. B. Tackboard Panel: Basis-of-Design Forbo Bulletin Board or Architect approved equivalent, ¼” tackboard panel direct glued to gypsum wall board. 4. Color and Pattern: As selected by Architect from full range of industry colors. C. Aluminum Frames and Trim: Fabricated from not less than 0.062-inch- (1.57-mm-) thick, extruded aluminum; standard size and shape. 5. Field-Applied Trim: Manufacturer's standard. 6. Aluminum Finish: Clear anodic. ARCHITECT: Chamberlin Architects, P.C. BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#010.1740.doc D. Joints: Make joints only where total length exceeds maximum manufactured length. Fabricate with minimum number of joints, as indicated on approved Shop Drawings. 5. Specification 09 6813 Tile Carpeting: Add paragraph 2.4: 2.4 Walk Off Carpet Tile – WCPT A. Basis-of-Design product Mannington Force Modular carpet tile B. Color: to be selected from manufacturer’s standard colors C. Installation Method: Horizontal Brick Ashlar D. Fiber Content: Type 6,6 Nylon E. Fiber Type: Solution Dyed F. Pile Characteristic: Textured Patterned Loop G. Density: 7,005 H. Backing: Infinity Modular Reinforced Composite Closed Cell Polymer with Recycled Content. I. Size: 18” x 36” 6. Specification 124813, Entrance Floor Mats and Frames: Delete specification section. Drawings: 7. Drawing A001, Wall Type 9: Change overall wall thickness from 1’-4 ½” to 1’-5 5/8”. 8. Drawing A001: At exterior wall types (Types 5, 6, 7, 8, 9 & 11):  Change continuous insulation from 4” thick mineral-wool board insulation to 2.5” thick foil-faced polyisocyanurate board insulation with sealed and taped seams.  Delete fluid-applied weather barrier. 9. Drawing A161:  Change floor finish in Lobby 101 from PCONC/EM to PCONC/WCPT.  Change floor finish in Stair 302 from WD to PCONC. 10. Drawing A601: Modify Details 2 thru 11 as illustrated in the attached reissued Drawing A601. 11. Drawing A612, Detail 7:  Delete wood tread, stair nosing, spacers in concrete to attach wood tread & fastener attached from below. Tread finish at Stair 302 to be polished concrete (PCONC). 12. Drawing A641: Modify Details 1 thru 4 as illustrated in the attached reissued Drawing A641. 13. Drawing A642: Modify Detail 1 as illustrated in the attached reissued Drawing A642. 14. Drawing A643: Modify Details 1 & 2 as illustrated in the attached reissued Drawing A643. 15. Drawing A644: Modify Details 1 thru 3 as illustrated in the attached reissued Drawing A644. 16. Drawing A651, Detail 5:  Change note WD STAIR TREAD to PCONC STAIR TREAD.  Delete note EXTEND GYP BEHIND TREAD. 17. Drawing A702: Modify Details 1 thru 6 as illustrated in the attached reissued Drawing A702. 18. Drawing A703: Modify Details 14 & 15 as illustrated in the attached reissued Drawing A703. 19. Drawing A721, Interior Window Types: Change glass type at all interior window types from IG-1 to GL-2. 20. Drawing A731: Modify Details 1 thru 7 as illustrated in the attached reissued Drawing A731. 21. Drawing A732: Modify Details 1 thru 3 & 8 as illustrated in the attached reissued Drawing A732. ARCHITECT: Chamberlin Architects, P.C. BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#010.1740.doc 22. Drawing A733: Modify Details 1 thru 4 as illustrated in the attached reissued Drawing A733. 23. Drawing S102: Delete depressed slab for entrance mat between Grids H & I.9 and Grids 2 & 3. Attachments: A601; A641; A642; A643; A644; A702; A703; A731; A732; A733 REVISION ELEVATION COLUMN GRID LOCATION DOOR NUMBER WINDOW TYPE CENTER LINE LINE OF WALL ABOVE OR HIDDEN LINE BREAK LINE MATCH LINE ROOM NAME ROOM NUMBER BASIC WALL TYPE A101 1 2 3 4 A 101A Room 101 1 A101 TYP 1 A101 TYP ANGLE DIAMETER PERPENDICULAR PLATE PLUS OR MINUS FLOOR DRAIN FIRE EXTINGUISHERFE FD 1 1 100' 0" TOP OF WALL AL HM INTERIOR WALL ELEVATION REFERENCE DRAWING REFERENCED SECTION NUMBER SHEET NUMBER REFERENCED DETAIL NUMBER SHEET NUMBER 1. COMPLY WITH ALL MANUFACTURERS RECOMMENDATIONS AND INDUSTRY STANDARDS RELEVANT TO THE WORK HEREIN. 2. ALL DIMENSIONS ARE FROM FACE OF FINISH UNO. 3. ALL ALIGNMENTS ARE FACE OF FINISH UNO. 4. FIELD VERIFY ALL DIMENSIONS AND ROUGH OPENINGS PRIOR TO FABRICATION AND/OR INSTALLATION. ABV above ACC accessories ADJ adjustable AFF above finished floor ALT alternate AL aluminum APC acoustical panel ceiling ARCH architect (ural) ASPH asphalt A/C air conditioning BCS baby changing station BD board BLDG building BLKG blocking BO bottom of BRG bearing CBU cemetitious backer unit CG corner guard CIP cast in place CJ control joint CLG ceiling CLR clear (ance) CMU concrete masonry unit COL column CONC concrete CONT continuous or continue CORR corridor CPT carpet (ed) CSMT casement CT ceramic tile CTR center CU condenser unit CWOG center wall on grid DBL double DEMO demolish / demolition DF drinking fountain DIM dimension (s) DIR direction DISP dispenser DN down DR door DS downspout DTL detail DWG drawing DWR drawer E east EA each EC evaporative cooler EG etched glass/glazing EIFS exterior insul finish sys EJ expansion joint EL elevation ELEC electric (al) EM emergency EWC electric water cooler EWG end wall corner guard EQ equal EXG existing EXH exhaust EXP exposed EXT exterior FBO furnished by owner FD floor drain FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FEP finished end panel FFE finished floor elevation FIN finish FLG flashing FLR floor (ing) FLUR fluorescent FO face of FRMG framing FRP fiber reinforced plastic FT foot (feet) FTG footing GA gage, gauge GAL gallon GALV galvanized GB grab bar GC general contractor GL glass, glazing GWB gypsum wallboard GYP gypsum HAS headed anchor stud HB hose bibb HCP handicap (ed) HDR header HDW hardware HM hollow metal HOR horizontal HR hose reel HSS hollow structural sections HT height HVAC heating /ventilation /air conditioning HWD hardwood INCL include (d) (ing) INSUL insulate (d) (ing) INT interior INV invert JST joist JT joint L length, angle LAM laminate (d) LAV lavatory LB pound LF lineal foot LG laminated glass, glazing LIN linoleum LT light MA match MAS masonry MATL material MAX maximum MB marker board MECH mechanic (al) MFR manufacture (r) (d) MH manhole MIN minimum MISC miscellaneous MLD molding, moulding MO masonry opening MT mount (ed) (ing) MTL metal N north N/A not applicable NIC not in contract NOM nominal NTS not to scale NECY necessary OC on center (s) OD outside diameter OFCI owner furnished, contractor installed OFD overflow drain OFOI owner furnished, owner installed OH overhead OL occupant load OLF occupant load factor OPG opening OPH opposite hand OPP opposite OSB oriented strand board OTA open to above OTS open to structure PB particle board PERF perforate (d) PERIM perimeter PG pattern glass PLAM plastic laminate PLT plate PNL panel PNT paint (ed) PR pair PROJ projector, projection PSF pounds per square foot PSI pounds per square inch PT pressure treated PTD paper towel dispenser PTN partition PVC polyvinyl cholride PVMT pavement PWD plywood QT quarry tile R riser, radius RB rubber base REC recycling RCMD recommend (ed) (ations) RE reference REF refrigerator REIN reinforce (d) (ing) REQ required REV revision (s), revised RD roof drain RFG roofing RH robe hook RM room RO rough opening ROW right of way RR restroom RTU roof top unit RUB rubber S south SAG susp acoustic grid SC shower curtain rod & hooks SCH schedule SD soap dispenser SHT sheet SHTG sheathing SIM similar SND sanitary napkin dispenser SNV sanitary napkin vendor SPEC specification SPKR speaker SQ square SS solid surface SST stainless steel STD standard STL steel STOR storage STR structural SUSP suspended T tread TB towel bar TEL telephone TG tempered glass THK thick T.O.top of TOC top of concrete TOS top of steel TOW top of wall TPD toilet paper dispenser TS tube steel TYP typical T&G tongue and groove UCR undercounter refigerator UNO unless noted otherwise VB vapor barrier VCT vinyl composition tile VERT vertical VIF verify in field VM vending machine VNL vinyl sheet VTR vent through roof W west, wide, width W/with WB wood base WC watercloset WD wood WDW window WF wide flange WG wire glass W/O without WP waterproof (ing) WR waste receptacle WRB weather resistive barrier WWM welded wire mesh WALL TYPE NOTES: 1. ALL EXTERIOR WALL TYPES ARE SHOWN WITH THE EXTERIOR WALL FACING RIGHT UNLESS OTHERWISE NOTED. 2. PROVIDE GLASS MAT WATER-RESISTANT BACKER BOARD IN LIEU OF GYPSUM WALL BOARD BEHIND ALL WALL TILE. 3. GYPSUM BOARD SHALL BE MOISTURE-RESISTANT AT THE FOLLOWING LOCATIONS: WALLS AND CEILINGS OF ALL RESTROOMS AND SHOWERS 4. WALL TYPE CHANGES OCCUR AT CORNERS OR INTERSECTIONS OF WALLS UNLESS NOTED OTHERWISE. 3-5/8" MTL STUDS @ 16" O.C. 5/8" GYP BD, EA SIDE. (ONE SIDE @ 1A) SOUND ATTN BATTS 5" ACOUSTICAL SEALANT, EA SIDE. FIRE CAULK IN LIEU OF @ FIRE RARTED LOCATIONS MTL RUNNER CHANNEL FLOOR LINE1/2"METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK CONT FIRE CAULK GWB TO DISSIMILAR MATERIALS, EA SIDE UL -U419 -1/2 HR RATED, STC: 49 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, EA SIDE (ONE SIDE @ 2A) SOUND ATTN BATTS 7 1/4" METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 1"UL -U419 -1 HR RATED @ STAIR & ELEVATOR 6" MTL STUDS @ 16" O.C. 5/8" GYP BD 1/2" EXT SHEATHING 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS AIR SPACE 4" CMU VENEER 1' - 4 1/4" VAPOR BARRIER MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 6" MTL STUDS @ 16" O.C. (10" @ 6A) 5/8" GYP BD 1/2" EXT SHEATHING 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS PRE-FINISHED HORIZONTAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' CLIPS SPACED VERTICALLY @ 24" O.C. VAPOR BARRIER 8" CIP CONC, RE: STR GL 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS OMIT WEATHER BARRIER & XPS INSULATION @ WALL TYPE 8A 10 1/2" 11" @ 3A 10" (2) 3-5/8" MTL STUDS @ 16" O.C. 5/8" GYP BD, EA SIDE SOUND ATTN BATTS ACOUSTICAL SEALANT, EA SIDE. FIRE CAULK IN LIEU OF @ FIRE RARTED LOCATIONS MTL RUNNER CHANNEL FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK UL -U493 -1 HR RATED, STC-59 CONT FIRE CAULK GWB TO DISSIMILAR MATERIALS, EA SIDE 1 - 1/2" AIR SPACE (2 1/2" @ 3A) ALUM STOREFRONT, NON-THERMALLY BROKEN UNINSULATED GLAZING METAL DECK 1"4 1/2" (6" @ 4A) ACOUSTICAL SEALANT, EA SIDE FLOOR LINE WALL TYPE ABV, 1 @ 4 1/2", 2 @ 6"2 1 CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 6" MTL STUDS SISTERED TO 6" MTL STUDS @ 16" O.C. 5/8" GYP BD 1/2" EXT SHEATHING. 5/8" EXT SHEATHING @ 7A 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS PRE-FINISHED VERTICAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' GIRTS SPACED HORIZONTALLY @ 24" O.C. VAPOR BARRIER 1' - 4 3/4" UL -U419 -1 HR RATED @ 7A 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS 8" CONC (12" CONC @ 9A), RE: STR AIR SPACE 4" CMU VENEER 1' - 5 5/8" 1-HR RATED, per TABLE 721.1(2), 4-1.1. MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY GL 8" CMU, RE: STR 7/8" MTL FURRING CHANNELS @ 16" O.C. @ 10A 5/8" GYP BD @ 10A 9 1/4" 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, EA SIDE SOUND ATTN BATTS 7 3/4" METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"1/2" PWD CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS 8" CMU, RE: STR AIR SPACE 4" CMU VENEER 1' - 4 1/2" MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, ONE SIDE SOUND ATTN BATTS METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"4" CMU VENEER 1/2" PWD. 5/8" EXT SHEATHING @ 2D CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 1' - 0 3/4" UL -U419 -1 HR RATED @ 2D 12" CIP CONC, RE: STR GL ACOUSTICAL SEALANT, ONE SIDE. FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES ACOUSTICAL SEALANT, ONE SIDE. 7/8" MTL FURRING CHANNEL @ 16" O.C. 5/8" GYP BD, ONE SIDE. NOT USED 2-1/2" MTL STUDS @ 16" O.C. 5/8" GYP BD, ONE SIDE ACOUSTICAL SEALANT, ONE SIDE. MTL RUNNER CHANNEL FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK ACOUSTICAL SEALANT, ONE SIDE. FULLY ADHERED SINGLE PLY ROOF MEMBRANE 1/2" COVER BOARD R-35 RIGID INSULATION VAPOR BARRIER MTL ROOF DECK, RE: STR DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt11/6/2018 10:08:34 AMA001 OCTOBER 16, 2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO NOTES, SYMBOLS, ABBREVIATIONS AND WALL TYPES PROJECT STATUS: 100% CD SH JW ASPEN AMBULANCE DISTRICT FACILITY SYMBOLS GENERAL NOTESARCHITECTURAL ABBREVIATIONS 0'6"1'0'6"1' A001 WALL TYPES1 WALL TYPE 1 & 1A WALL TYPE 2 & 2A WALL TYPE 5 WALL TYPE 6 & 6A WALL TYPE 8 & 8A WALL TYPE 3 & 3A WALL TYPE 4 & 4A WALL TYPE 7 &7A WALL TYPE 9 & 9A WALL TYPE 10 & 10A WALL TYPE 2B WALL TYPE 11 WALL TYPE 2C & 2D WALL TYPE 12 WALL TYPE 1B WALL TYPE 13 WALL TYPE 14 CLASS 'A' ROOF ASSEMBLY NO: ISSUED FOR: DATE: 2 Response to City of Aspen Review Comments 7/16/18 6PR#010 9/25/18 CONC FOUNDATION, RE: STR RIGID PERIMETER INSULATION FOUNDATION WATERPROOFING CONC DRIVEWAY W/ SNOWMELT, RE: CIVIL CONT GALV MTL THRU WALL FLASHING & WEEPS 1" RIGID INSULATION @ SNOWMELTED SLAB EDGE & 2" BELOW SLAB WEATHER BARRIER FLASHING OVER MTL FLASHING FLANGE 5 CONT SEALANT (TYP) 6 CONC FOUNDATION WALL, RE: STR RIGID PERIMETER INSULATION FOUNDATION WATERPROOFING CAPILARY BREAK PERIMETER FOUNDATION DRAIN W/ FILTER FABRIC, RE: CIVIL 7 6 WEATHER BARRIER FLASHING, LAP 6" DOWN WALL & 3" UP BEHIND MTL DRIP FLASHING PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT W/ WEEP HOLES WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE LAP WEATHER BARRIER OVER WEATHER BARRIER FLASHING PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE 6 PRE FINISHED MTL CORNER W/ HEMMED EDGES RIVET CONNECTION @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRTS @ INSULATION PERIMETER FOR ATTACHMENT POINTS 6TYP4"11 6 7 6 WEATHER BARRIER FLASHING PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT THERMALLY BROKEN 'C' GIRT CONT PT WD 2x BLK'G, SLOPE TOP SLOPE 3/4"2 1/2"PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE 6 7 5 CONT BACKER ROD & SEALANT (TYP) PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP 6" DOWN WALL & 3" UP BEHIND MTL DRIP FLASHING 6 CONC FOUNDATION, RE: STR RIGID PERIMETER INSULATION FOUNDATION WATERPROOFING CONC DRIVEWAY W/ SNOWMELT, RE: CIVIL CONT GALV MTL THRU WALL FLASHING & WEEPS 1" RIGID INSULATION @ SNOWMELTED SLAB EDGE & 2" BELOW SLAB WEATHER BARRIER FLASHING OVER MTL FLASHING FLANGE 11 CONT SEALANT (TYP) 6 7 9A 141 3/4"WEATHER BARRIER FLASHING, LAP 6" DOWN WALL & 3" UP BEHIND MTL DRIP FLASHING PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT, SLOPE TOP 1/2" PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE CONT PT WD BLK'G 6 6 2 1/2"5 2 4 CONT PT WD BLK'G, SLOPE TOP WEATHER BARRIER FLASHING, LAP 6" DOWN WALL, OVER 2x SILL BLKG ABOVE & 3" UP WALL PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT, SLOPE TOP 3/4" PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE CONT PT WD BLK'G 6 3/4" PWD BLOCKING 7 6 TYP4"PRE FINISHED MTL CORNER W/ HEMMED EDGES RIVET CONNECTION @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRTS @ INSULATION PERIMETER FOR ATTACHMENT POINTS MTL 'Z' FURRING @ CUT PANEL LOCATIONS FOR ATTACHMENT (TYP) ALIGN W/ SOFFIT HEADER ABOVE CTR MTL PANEL JOINT ON WALL SEGMENT 6" MTL STUD FRM'G W/ WALL TYPE 7 FINISH PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE RIVET CONNECTION @ 12" O.C. W/ CONT SEALANT TAPE CONT BACKER ROD & SEALANT (TYP) 1/2" PWD BLK'G @ COLUMN STL COLUMN, RE: STR 6 7 CONC FOUNDATION, RE: STR RIGID PERIMETER INSULATION FOUNDATION WATERPROOFING CONC RAMP, RE: CIVIL CONT GALV MTL THRU WALL FLASHING & WEEPS WEATHER BARRIER FLASHING OVER MTL FLASHING FLANGE CONT SEALANT (TYP) GROUT CAVITY SOLID BELOW FLASHING 6 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:17 AMA601 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO EXTERIOR DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A601 TOP OF FOUNDATION @ 6" MTL STUD WALL2 0'6"1'0'6"1' A601 FOUNDATION WALL1 0'3"6"0'3"6" A601 METAL WALL TRANSITION HEAD9 0'3"6"0'3"6" A601 METAL WALL TRANSITION CORNER10 0'3"6"0'3"6" A601 METAL WALL TRANSITION SILL5 0'3"6"0'3"6" A601 METAL WALL TRANSITION TO CMU JAMB8 0'3"6"0'3"6" A601 TOP OF FOUNDATION WALL @ CMU3 0'3"6"0'3"6" A601 METAL WALL TRANSITION TO CMU SILL 27 0'3"6"0'3"6" A601 METAL WALL TRANSITION TO CMU SILL6 0'3"6"0'3"6" A601 METAL WALL TRANSITION CORNER 211 0'3"6"0'3"6" A601 WEEPS & FLASHING DETAIL @ GRADE4 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 4"ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT PRE FINISHED MTL ROOD EDGE FLASHING W/ CONT GALV CLEAT LAP ROOF MEMBRANE OVER WEATHER BARRIER FLASHING & DOWN FASCIA MTL 'C' GIRT @ TOP & BOTTOM OF FRM'G FOR INSULATION ATTACHMENT PT WD 2x BLK'G (TYP) CONT SEALANT TO DECK (TYP) STL STUD ROOF FRM'G, RE: STR ROOF MEMBRANE FULLY ADHERED TO SUBSTRATE 1/2" EXT SHEATHING ON RIGID INSULATION W/ MTL 'Z' GIRTS @ 16" O.C. ON 1/2" PWD SHEATHING ON 6" MTL STUD FRM'G W/ BATT INSULATION W/ 5/8" GWB 6 6 6" X 6" PRE FINISHED MTL GUTTER, COLOR TO MATCH ADJACENT MTL PNL PRE-FINISHED VERTICAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' GIRTS SPACED VERTICALLY @ 12" O.C. PRE FINISHED MTL DRIP EDGE FLASHING MTL "C" GIRT ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT SINGLE PLY ROOF MEMBRANE, LAP DOWN FASCIA 1/2" COVER BOARD ON RIGID INSULATION TPO-COATED STL BASE PLATE SST PIPE SNOW GUARDS (TYP OF 2) STL BEAM, RE: STR 1 ' - 4 " 1 ' - 4 "2 1/2"PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL VAPOR BARRIER 7 SAG CLG, RE: RCP PRE FINISHED MTL FLASHING, LAP UP BEHIND GUTTER 6 1 0 4"7 ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT PRE FINISHED MTL ROOD EDGE FLASHING W/ CONT GALV CLEAT LAP ROOF MEMBRANE OVER WEATHER BARRIER FLASHING & DOWN FASCIA WEATHER BARRIER FLASHING, LAP OVER TOP OF PARAPET MTL 'C' GIRT @ TOP & BOTTOM OF FRM'G FOR INSULATION ATTACHMENT PT WD 2x BLK'G (TYP) SINGLE PLY ROOF MEMBRANE ON 1/2" COVER BOARD ON RIGID INSULATION VAPOR BARRIER CONT SEALANT TO DECK (TYP) 6 J 7 ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT PRE FINISHED MTL ROOD EDGE FLASHING W/ CONT GALV CLEAT LAP ROOF MEMBRANE OVER WEATHER BARRIER FLASHING & DOWN FASCIA WEATHER BARRIER FLASHING, LAP OVER TOP OF PARAPET MTL 'C' GIRT @ TOP & BOTTOM OF FRM'G FOR INSULATION ATTACHMENT PT WD 2x FRM'G (TYP) SINGLE PLY ROOF MEMBRANE ON 1/2" COVER BOARD ON RIGID INSULATION VAPOR BARRIER SLOPES T.O. ROOF EDGE 1-5/8" MTL STUD FRM'G @ 16" O.C. IN BEAM FLANGE W/ BATT INSULATION CONT SEALANT TO DECK (TYP) 6" 6 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:19 AMA641 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO ROOF DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'6"1'0'6"1' A641 ROOF DETAIL @ ELEVATOR4 0'3"6"0'3"6" A641 ROOF GUTTER2 0'3"6"0'3"6" A641 ROOF EDGE FLASHING - NORTH1 0'3"6"0'3"6" A641 ROOF EDGE FLASHING - EAST/WEST3 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 12 0 5 LAP WEATHER BARRIER FLASHING OVER MTL FLASHING FLANGE LAP WEATHER BARRIER OVER WEATHER BARRIER FLASHING PRE FINISHD MTL THRU WALL FLASHING W/ CONT GALV CLEAT & WEEPS 3"GROUT CAVITY SOLID BELOW WEEPS & FLASHING FULLY ADHERE ROOF MEMBRANE TO SUBSTRATE & LAP BEHIND FLASHING CLEAT CONT CANT ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT PRE FINISHED MTL ROOD EDGE FLASHING W/ CONT GALV CLEAT LAP ROOF MEMBRANE OVER WEATHER BARRIER FLASHING & DOWN FASCIA 4"2 2 2 6 6 10 WEATHER BARRIER FLASHING, LAP OVER TOP OF PARAPET MTL 'C' GIRT @ TOP & BOTTOM OF FRM'G FOR INSULATION ATTACHMENT PRE FINISHED MTL FASCIA W/ FLAT LOCK SEAM @ VERTICAL JOINTS 113' - 4 1/2" T.O. CANOPY 26 24 24 2 624 111' - 7 1/4" B.O. CANOPY 2.5" RIGID INSULATION @ FASCIA & SOFFIT PT WD 2x BLK'G (TYP) CONT PT WD 2x @ CANOPY SOFFIT PERIMETER WRAP PRE FINISHED MTL FASCIA FLASHING OVER BLK'G & ATTACH BELOW SOFFIT FINISH CONT BACKER ROD & SEALANT (TYP) 1x6 WD PLANK SOFFIT FINISH ON 3" MTL 'Z' GIRTS W/ RIGID INSULATION WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8" MTL FURRING ATTACHED TO STL BEAMS, RE: STR FILL CANOPY CAVITY W/ BATT INSULATION SINGLE PLY ROOF MEMBRANE ON 1/2" COVER BOARD ON TAPERED RIGID INSULATION ON MTL ROOF DECK, RE: STR GWB ON RIPPED WD 2x6 FRM'G @ 16" O.C. LAP WEATHER BARRIER OVER MTL FLASHING FLANGE PRE FINISHED MTL FLASHING DRIP EDGE W/ CONT HEMMED EDGE CONT BACKER ROD & SEALANT, EA SIDE (TYP) WEATHER BARRIER FLASHING, LAP INTO OPENING ALUM STOREFRONT CONT SEALANT (TYP) MTL STUD HEADER, RE: STR 4' - 3" 6 6 ALUM BRK MTL TO MATCH STOREFRONT DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:20 AMA642 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO ROOF DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A642 CANOPY SECTION1 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 J 4"1/2" SLOTTED STL ANGLE @ SCUPPER FOR 2x ATTACHMENT 26 5 2' - 7" LAP WEATHER BARRIER FLASHING OVER MTL FLASHING FLANGE PRE FINISHD MTL THRU WALL FLASHING W/ CONT GALV CLEAT & WEEPS GROUT CAVITY SOLID BELOW WEEPS & FLASHING FULLY ADHERE ROOF MEMBRANE TO SUBSTRATE & LAP BEHIND FLASHING CLEAT CONT CANT SINGLE PLY ROOF MEMBRANE ON 1/2" COVER BOARD ON TAPERED RIGID INSULATION ON MTL ROOF DECK, RE: STR3"SLOPE ROOF FLASHING MEMBRANE W/ CONT EDGE SEALANT, CTR OVER FLASHING STRIP BELOW ROOF FLASHING MEMBRANE, CTR ON END OF SCUPPER SLEEVE BELOW WELDED & PRE FINISHED MTL SCUPPER SLEEVE W/ DRIP EDGE, EXTEND 2-1/2" BEHIND ROOF MEMBRAN FLASHING RETURNS @ SCUPPER SIDES. COLOR TO MATCH ADJACENT ROOF EDGE LAP ROOF MEMBRANE OVER WEATHER BARRIER FLASHING & 1" DOWN FASCIA PANEL, ADHERE WEATHER BARRIER FLASHING, LAP OVER TOP OF PARAPET MTL 'C' GIRT @ TOP & BOTTOM OF FRM'G FOR INSULATION ATTACHMENT PRE FINISHED MTL FASCIA W/ FLAT LOCK SEAM @ VERTICAL JOINTS 2.5" RIGID INSULATION @ FASCIA & SOFFIT CONT PT WD 2x @ CANOPY SOFFIT PERIMETER WRAP PRE FINISHED MTL FASCIA FLASHING OVER BLK'G & ATTACH BELOW SOFFIT FINISH CONT BACKER ROD & SEALANT (TYP) 1x6 WD PLANK SOFFIT FINISH ON 3" MTL 'Z' GIRTS W/ RIGID INSULATION WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8" MTL FURRING ATTACHED TO STL BEAMS, RE: STR FILL CANOPY CAVITY W/ BATT INSULATION LAP WEATHER BARRIER OVER MTL FLASHING FLANGE PRE FINISHED MTL FLASHING DRIP EDGE W/ CONT HEMMED EDGE CONT BACKER ROD & SEALANT, EA SIDE (TYP) WEATHER BARRIER FLASHING, LAP INTO OPENING ALUM STOREFRONT CONT SEALANT (TYP) MTL STUD HEADER, RE: STR 6 6 6 6" X 6" PRE FINISHED MTL GUTTER, COLOR TO MATCH ADJACENT MTL PNL PRE-FINISHED VERTICAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' GIRTS SPACED VERTICALLY @ 12" O.C. PRE FINISHED MTL DRIP EDGE FLASHING MTL "C" GIRT ROOF MEMBRANE FLASHING W/ CONT EDGE SEALANT SINGLE PLY ROOF MEMBRANE, LAP DOWN FASCIA 1/2" COVER BOARD ON RIGID INSULATION TPO-COATED STL BASE PLATE SST PIPE SNOW GUARDS (TYP OF 2) STL BEAM, RE: STR PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL VAPOR BARRIER 2 1/2"PRE FINISHED MTL FLASHING, LAP UP BEHIND GUTTER PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED BRK MTL FLASHING CLOSURE PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE WD 1x6 SOFFIT ON 7/8" MTL FURRING PRE FINISHED BRK MTL SOFFIT W/ FLAT LOCK JOINTS WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8" MTL FURRING PRE FINISHED MTL FASCIA FLASHING W/ HEMMED EDGE & CONT GALV CLEAT, FASTEN BEHIND WD SOFFIT 1/2" EXT SHEATHING ON 3-5/8" MTL STUDS @ 16" O.C. ATTACHED TO STL BEAM, RE: STR 6 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:21 AMA643 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO ROOF DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A643 CANOPY SCUPPER DETAIL1 0'3"6"0'3"6" A643 ROOF DETAIL - SOUTH @ SOFFIT2 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 C 6 MTL 'C' GIRT W/ WEEP HOLES @ 8" O.C. PRE FINISHED MTL PANE EDGE TRIM W/ WEEPS BY MTL PANEL INSTALLER PRE FINISHED MTL THRU WALL FLASHING W/ CONT GALV CLEAT & WEEPS CONC PAVER ON ADJUSTABLE PEDESTAL SYSTEM ROOF MEMBRANE ON 1/2" COVER BOARD ON HIGH DENSITY RIGID INSULATION STL BEAM & MTL DECK, RE: STR PT WD 2x4 FRM'G @ 16" O.C., FILL CAVITIES W/ RIGID INSULATION 3"3"FLASHING RETURN UP WALL1' - 0" PRE FINISHED MTL THRU WALL6 E 14 5 6 1/4"3" PRE FINISHD MTL THRU WALL FLASHING W/ CONT GALV CLEAT & WEEPS ROOF MEMBRANE ON 1/2" COVER BOARD ON HIGH DENSITY RIGID INSULATION CONC PAVER ON ADJUSTABLE PEDESTAL SYSTEM GROUT CAVITY SOLID BELOW WEEPS & FLASHING STL SHIMS @ CMU BLOCK, RE: STR CONT PT WD 2x4 BLK'G @ 16" O.C., FILL CAVITIES W/ RIGID INSULATION 3"6 7 6"5"2"1' - 0"3' - 6"CONT STL 2"x2" TUBE TOP RAIL& VERTICALS @ 48" O.C. STL 2"x1/2" HORIZONTAL BARS SPACED @ 4" O.C. & WELDED TO 2"x2" VERTICALS TYP4"ROOF MEMBRANE ON 1/2" COVER BOARD ON HIGH DENSITY RIGID INSULATION CONC PAVER ON ADJUSTABLE PEDESTAL SYSTEM SINGLE PLY ROOF MEMBRANE FULLY ADHERED TO 1/2" EXT SHEATHING SUBSTRATE LAP ROOF MEMBRANE OVER PARAPET & DOWN FASCIA WEATHER BARRIER FLASHING, LAP OVER PARAPET & 6" DOWN WALL BEHIND RIGID INSULATION PRE FINISHED MTL PARAPET COPING W/ CONT CLEAT CONT BACKER ROD & SEALANT (TYP) (2) LAYERS 3/4" PWD ATTACHED TO CONC STL WELD PLATE, RE: STR 4"x12"x3/8" STL PLATE @ 48" O.C. ALIGN WITH MASONRY JOINTS (TYP) 9 6 4 3"ALUM STOREFRONT W/ CONT SUB SILL IN CONT SEALANT BED PRE FINISHED MTL FLASHING W/ CONT GALV CLEAT TYP 1" CONC PAVER ON ADJUSTABLE PEDESTAL SYSTEM ROOF MEMBRANE ON 1/2" COVER BOARD ON HIGH DENSITY RIGID INSULATION STL BEAM & MTL DECK, RE: STR PT WD 2x4 FRM'G @ 16" O.C., FILL CAVITIES W/ RIGID INSULATION VAPOR BARRIER, LAP UP WALL 4 1/2"1" 5" 1/2" EXT SHEATHING ON 1-5/8" MTL STUD FRM'G @ 16" O.C. CONT CANT DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:23 AMA644 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO DECK DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A644 DECK DETAIL - WEST1 0'3"6"0'3"6" A644 DECK DETAIL - EAST2 0'3"6"0'3"6" A644 DECK - RAIL DETAIL3 0'3"6"0'3"6" A644 DECK DETAIL - NORTH4 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 7 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED4"CONT SEALANT (TYP) PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE PRE FINISHED MTL FLASHING W/ WEEP HOLES PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE 6 PRE FINISHED MTL TRIM 7 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED2"CONT SEALANT (TYP) PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT PRE FINISHED MTL FLASHING 2" 6 9 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED4"STL ANGLE, RE: STR (PNT) CONT SEALANT (TYP) WEATHER BARRIER OVER WEATHER BARRIER FLASHING WEATHER BARRIER FLASHING THROUGH WALL WEEPS & FLASHING 1' - 3" 6 9 CONT BACKER ROD & SEALANT (TYP) WEATHER BARRIER FLASHING HM FRAME, PNT DOOR, RE: SCHED GL CONT SEALANT (TYP) BULLNOSE EDGE 2"2" 6 11 WEATHER BARRIER OVER WEATHER BARRIER FLASHING STL ANGLE & PLATE, RE: STR (PNT) OH DOOR, RE: SCHED 0 WEATHER BARRIER FLASHING THROUGH WALL WEEPS & FLASHING GROUT CAVITY SOLID BELOW FLASHING 6 11 OH DOOR, RE: SCHEDULE 0 CONT BACKER ROD & SEALANT RETURN CMU VENEER @ JAMB 6" DIA CONCRETE FILLED BOLLARD. ALIGN WITH DOOR OPENING 1 1' - 0"1' - 6" BULLNOSE EDGE 3"1 1/2"2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 1 1/2"2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 3 2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 3 2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 OVERHEAD DOOR, RE: SCHED MTL STUD HEADER, RE: STRUC 2 DOOR, RE: SCHED CORNER GAURD @ BOTH SIDES DOUBLE STUD AT JAMB, TYP. DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:25 AMA702 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO DOOR DETAILS PROJECT STATUS: 100% CD KH JW ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 73 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 74 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 91 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 92 0'3"6"0'3"6" A702 OH DOOR HEAD @ WALL TYPE 55 0'3"6"0'3"6" A702 OH DOOR JAMB @ WALL TYPE 56 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 1 & 27 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 1 & 28 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 39 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 310 0'3"6"0'3"6" A702 OH DOOR HEAD @ WALL TYPE 211 0'3"6"0'3"6" A702 OH DOOR JAMB @ WALL TYPE 212 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 6 METAL TRANSITION STRIP, CENTER UNDER DOOR @ FLR'G OF DIFF HGTS, RE: SPECS DOOR, RE: SCHED PCONC, RE: FINISH PLANS CT METAL TRANSITION STRIP, CENTER UNDER DOOR @ FLR'G OF DIFF HGTS, RE: SPECS DOOR, RE: SCHE CPT, RE: FINISH PLANS CT MTL TRANSITION STRIP, RE; SPECS RUB DOOR, RE: SCHED ALUM DOOR, RE: SCHED ALUM THRESHOLD, SET IN FULL SEALANT BED CPT FLOOR FINISH, RE: FINISH PLANS ALUM DOOR, RE: SCHED ALUM THRESHOLD, SET IN FULL SEALANT BED TRANSITION STRIP, CENTER UNDER DOOR, RE: SPECS CPT DOOR, RE: SCHED FLOOR FINISH, RE: FINISH PLANS DOOR, RE: SCHED ALUM THRESHOLD IN CONT SEALANT BEDANGLE (TYP)SST GRATING CARPET INSERT 5/8"10 CONT SEALANT & BACKER ROD, EA SIDE (TYP) HM FRAME, W/ EQ RABBETS (PNT) BOND BEAM, RE: STR GL DOOR, RE: SCHED2"MATCH CMU DEPTH 10 CONT SEALANT & BACKER ROD, EA SIDE (TYP) HM FRAME W/ EQ RABBETS (PNT)2"MATCH CMU DEPTH MASONRY FRAME ANCHOR GL DOOR, RE: SCHED2"DOOR, RE: SCHED ALUM THRESHOLD IN CONT SEALANT BED 2C GL CONT SEALANT (TYP) STL ANGLE, RE: STR (PNT)HM FRAME, PNT DOOR, RE: SCHED 9 1/4"2"2" 2C PROVIDE DOUBLE STUDS @ JAMBS PERPENDICULAR WALL GL SEALANT 2"9 1/4" 5 GL CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED4"STL ANGLE, RE: STR (PNT) CONT SEALANT (TYP) WEATHER BARRIER OVER WEATHER BARRIER FLASHING WEATHER BARRIER FLASHING THROUGH WALL WEEPS & FLASHING 1' - 2" 2" 6 5 GL BACKER ROD & SEALANT DOOR, RE: SCHED WRAP WEATHER BARRIER INTO OPENING AND SEAL SEALANT 1' - 2"2"2" 6 WEATHER BARRIER FLASHING CASEWORK SIDELITE RAIL, RE: SPECS WD BASE W/ CHAMFERED EDGE SIDELITE DOOR, RE: SCHED ALIGN RAIL W/ WALL FACE 1 1 1/4"4" 1 DOOR, RE: SCHED 1 1/4" DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:27 AMA703 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO DOOR DETAILS PROJECT STATUS: 100% CD SH JW ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CT TO PCONC2 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CT TO CPT6 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CONC TO RUB5 0'3"6"0'3"6" A703 DOOR THRESHOLD @ STOREFRONT A1 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CPT TO PCONC (ALUM DOOR)4 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CPT TO PCONC3 0'3"6"0'3"6" A703 DOOR THRESHOLD @ GRADE7 0'3"6"0'3"6" A703 WALK-OFF MAT9 0'3"6"0'3"6" A703 HM DOOR HEAD @ CMU11 0'3"6"0'3"6" A703 HM DOOR JAMB @ CMU10 0'3"6"0'3"6" A703 DOOR THRESHOLD @ CPT & GRADE8 0'3"6"0'3"6" A703 DOOR HEAD @ WALL TYPE 2C13 0'3"6"0'3"6" A703 DOOR JAMB @ WALL TYPE 2C12 0'3"6"0'3"6" A703 DOOR HEAD @ WALL TYPE 514 0'3"6"0'3"6" A703 DOOR JAMB @ WALL TYPE 515 0'3"6"0'3"6" A703 DOOR JAMB (SLIDING) @ WALL TYPE 117 0'3"6"0'3"6" A703 SLIDING DOOR HEAD @ WALL TYPE 116 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 5 ALUM STOREFRONT W/ CONT SUB SILL IN CONT SEALANT BED SLOPE 3/4"PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT 2 1/2"CONT PT WD 1x BLK'G 3/4" PWD BLOCKING CONT BACKER ROD & SEALANT (TYP) CONT SEALANT (TYP) WD SILL W/ EASED EDGES 1/2" CONT SEALANT FROM GWB TO SILL (TYP) MTL 'C' GIRT 6 WEATHER BARRIER FLASHING, LAP 6" DOWN WALL & OVER SILL BLKG INTO OPENING 7 WEATHER BARRIER FLASHING, LAP 6" DOWN WALL ALUM STOREFRONT W/ CONT SUB SILL IN CONT SEALANT BED PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT CONT PT WD BLK'G SLOPE 3/4" WD SILL W/ EASED EDGES CONT SEALANT (TYP) THERMALLY BROKEN 'C' GIRT CONT SEALANT FROM GWB TO SILL (TYP) CONT BACKER ROD & SEALANT (TYP) GL 6 3/4" PWD BLOCKING 7 PRE-FINISHED MTL PNL PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL PRE FINISHED BRK MTL SOFFIT FLASHING WEATHER BARRIER FLASHING ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) GL 4"1/2" WD SILL BELOW CONT SEALANT (TYP) 6 7 PRE FINISHED BRK MTL FLASHING CLOSURE MTL 'C' GIRT PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE PRE FINISHED BRK MTL SOFFIT FLASHING WEATHER BARRIER FLASHING, LAP INTO OPENING ALUM STOREFRONT WINDOW CONT SEALANT (TYP) CONT BACKER ROD & SEALANT, EA SIDE (TYP) PRE-FINISHED MTL PNL WEATHER BARRIER FLASHING 6 C 1 0 CONT BACKER ROD & SEALANT, EA SIDE (TYP) WD SILL BELOW DRYWALL RETURN WEATHER BARRER FLASHING STL COLUMN, RE: STR 2 7 CONT SEALANT (TYP) MTL SILL BELOW PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL PRE FINISHED BRK MTL SOFFIT FLASHING ALUM STOREFRONT WINDOW 4"1/2"MTL 'C' GIRT 6 4 6A MTL 'C' GIRT PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE PRE FINISHED BRK MTL SOFFIT FLASHING WEATHER BARRIER FLASHING, LAP INTO OPENING STL BEAM, RE: STR 3 1/2"1" CONT SEALANT (TYP) CONT BACKER ROD & SEALANT (TYP) ALUM STOREFRONT WINDOW PRE-FINISHED MTL PNL WEATHER BARRIER FLASHING 6 5 72 1/2"STL BEAM, RE: STR 1/2"4" 1/2"4" WEATHER BARRIER FLASHING MTL 'C' GIRT PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE PRE FINISHED BRK MTL SOFFIT FLASHING ALUM STOREFRONT WINDOW CONT SEALANT (TYP) CONT BACKER ROD & SEALANT, EA SIDE (TYP) PT WD BLK'G WEATHER BARRIER FLASHING, LAP 6" DOWN WALL & OVER 2x SILL BLKG INTO OPENING PRE FINISHED MTL SILL FLASHING W/ CONT GALV CLEAT PRE-FINISHED MTL PNL CONT PT WD 2x BLK'G SLOPE 3/4"WD SILL W/ EASED EDGES ALUM STOREFRONT W/ CONT SUB SILL IN CONT SEALANT BED 6 WEATHER BARRIER FLASHING 3/4" PWD BLOCKING DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:27 AMA731 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO EXTERIOR WINDOW DETAILS PROJECT STATUS: 100% CD KH, PH JW ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A731 WINDOW SILL DETAIL @ WALL TYPE 51 0'3"6"0'3"6" A731 WINDOW SILL DETAIL @ WALL TYPE 72 0'3"6"0'3"6" A731 WINDOW JAMB DETAIL @ WALL TYPE 75 0'3"6"0'3"6" A731 WINDOW HEAD DETAIL @ WALL TYPE 77 0'3"6"0'3"6" A731 WINDOW JAMB DETAIL @ WALL TYPE 7 & COLUMN TRANSITION4 0'3"6"0'3"6" A731 WINDOW HEAD DETAIL @ WALL TYPE 6A6 0'3"6"0'3"6" A731 WINDOW HEAD / SILL TRANSITION DETAIL @ WALL TYPE 7 AND BEAM3 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 G.9 6 PRE-FINISHED MTL PNL PRE-FINISHED MTL CORNER 1/8" X 3/16" POP RIVET 1'-0" O.C. MTL 'C' GIRT ALUM STOREFRONT WINDOW METAL SILL BELOW 1"3 1/2"4"1/2"6 6 STL COLUMN, RE: STR 1/2" PWD BLK'G PRE FINISHED BRK MTL SOFFIT FLASHING CONT BACKER ROD & SEALANT, EA SIDE (TYP) WEATHER BARRIER FLASHING J-TRIM GYP EDGE CONT SEALANT (TYP) WD SILL W/ EASED EDGES CONT BACKER ROD & SEALANT. EA SIDE (TYP) 6 WEATHER BARRIER FLASHING MTL 'C' GIRT ALUM STOREFRONT WINDOW METAL SILL BELOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) PWD BLK'G6 6 14 STL COLUMN, RE: STR PRE-FINISHED MTL FLASHING WD SILL BELOW PRE-FINISHED MTL PNL 6 J 0 4 1/2"4 1/2"3/4" ALUM STOREFRONT 90° CORNER ALUM STOREFRONT WINDOW G.9 2 DRYWALL RETURN ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) WRAP WEATHER BARRIER INTO OPENING J-TRIM GYP EDGE 5 CONT SEALANT (TYP) CONT SEALANT FROM MASONRY TO STOREFRONT 6 J ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) 1/2" PWD BLK'G STL COLUMN, RE: STR WEATHER BARRIER FLASHING 1" RIGID INSULATION @ COLUMNS (TYP) BREAK MTL, FINISH TO MATCH STOREFRONT WD SILL BELOW J 2 1/2" PWD BLK'G STL COLUMN, RE: STR WEATHER BARRIER FLASHING 1" RIGID INSULATION @ COLUMNS (TYP) ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) BREAK MTL, FINISH TO MATCH STOREFRONT4"1/2"4"1/2" WD SILL BELOW MTL SILL BELOW J 4"1/2" STL COLUMN, RE: STR 5 MTL 'C' GIRT RETURN BLOCK @ JAMB ALUM STOREFRONT WINDOW WEATHER BARRIER FLASHING WD SILL BELOW MTL SILL BELOW CONT BACKER ROD & SEALANT (TYP) WEATHER BARRIER FLASHING 6 2 SLOPE ALUM STOREFRONT W/ CONT SUB SILL IN CONT SEALANT BED DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:29 AMA732 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO EXTERIOR WINDOW DETAILS PROJECT STATUS: 100% CD PH, SH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A732 WINDOW JAMB CORNER DETAIL @ WALL TYPE 6 & COLUMN2 0'3"6"0'3"6" A732 WINDOW JAMB DETAIL @ WALL TYPE 6 & 143 0'3"6"0'3"6" A732 WINDOW CORNER DETAIL @ MAIN ENTRANCE6 0'3"6"0'3"6" A732 WINDOW JAMB DETAIL @ WALL TYPE 5 AND COLUMN8 0'3"6"0'3"6" A732 WINDOW JAMB DETAIL @ BREAK MTL COLUMN WRAP4 0'3"6"0'3"6" A732 WINDOW JAMB CORNER DETAIL @ BREAK MTL COLUMN WRAP7 0'3"6"0'3"6" A732 WINDOW JAMB DETAIL @ WALL TYPE 51 0'3"6"0'3"6" A732 WINDOW SILL DETAIL @ SLAB5 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 1 0 M 2 4 2 4 125' - 1 1/4" WINDOW HEAD 128' - 1" LOUVER HEAD ALUM LOUVER, RE: MECH ALUM BRK MTL FLASHING TO MATCH STOREFRONT WEATHER BARRIER FLASHING ON 1/2" PWD BLK'G 6" x 2" MTL STUD HEADER, FILL W/ INSULATION, RE: STR ALUM STOREFRONT WINDOW MANUAL ROLLER SHADE SAG CLG, RE: RCP CONT SEALANT (TYP) CONT BACKER ROD & SEALANT, EA SIDE (TYP) WD 2x BLK'G W/ CONT GWB WRAP @ ROLLER SHADE LOCATIONS PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE PRE FINISHED BRK MTL SOFFIT FLASHING, FASTEN BEHIND LOUVER FLANGE MTL 'C' GIRT WEATHER BARRIER FLASHING, LAP INTO OPENING PT WD 2x BLK'G 4"1/2" 7 WEATHER BARRIER, LAP OVER WEATHER BARRIER BELOW & THROUGH OPENING BEHIND LOUVER 2 4 1/2" PWD SHEATHING & RIGID INSULATION @ LOUVER LOCATIONS W/ OUT DUCT PT WD 2x BLK'G @ PWD LOCATIONS VAPOR BARRIER PRE-FINISHED MTL PNL 6 6 WEATHER BARRIER FLASHING 1 0 M 2 4 2 4 125' - 1 1/4" WINDOW HEAD 128' - 1" LOUVER HEAD ALUM LOUVER, RE: MECH ALUM BRK MTL FLASHING TO MATCH STOREFRONT WEATHER BARRIER FLASHING ON 1/2" PWD BLK'G ALUM STOREFRONT WINDOW MANUAL ROLLER SHADE SAG CLG, RE: RCP CONT SEALANT (TYP) CONT BACKER ROD & SEALANT, EA SIDE (TYP) WD 2x BLK'G W/ CONT GWB WRAP @ ROLLER SHADE LOCATIONS PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE LAP WEATHER BARRIER OVER MTL FLASHING FLANGE PRE FINISHED BRK MTL SOFFIT FLASHING, FASTEN BEHIND LOUVER FLANGE MTL 'C' GIRT WEATHER BARRIER FLASHING, LAP INTO OPENING PT WD 2x BLK'G 4"1/2" 7 6" x 2" MTL STUD HEADER, FILL W/ INSULATION, RE: STR PRE-FINISHED MTL PNL 6 WEATHER BARRIER FLASHING 0 PRE-FINISHED MTL PNL ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) PRE FINISHED MTL EDGE CAP PRE FINISHED BRK MTL FLASHING CLOSURE WEATHER BARRIER FLASHING MTL 'C' GIRT CONT SEALANT (TYP) 1 6 MTL SILL BELOW WD SILL BELOW CONT SEALANT (TYP) 6 6 PRE FINISHED MTL EDGE CAP PRE FINISHED BRK MTL SOFFIT FLASHING ALUM STOREFRONT WINDOW CONT BACKER ROD & SEALANT, EA SIDE (TYP) WD SILL BELOW SEALANT GYP RETURN MTL SILL BELOW MTL 'C' GIRT PRE-FINISHED MTL PNL 6 WEATHER BARRIER FLASHING DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:31 AMA733 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO EXTERIOR WINDOW DETAILS PROJECT STATUS: 100% CD PH DG ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A733 WINDOW HEAD DETAIL @ MECH LOUVER (W/ OUT DUCT)2 0'3"6"0'3"6" A733 WINDOW HEAD DETAIL @ MECH LOUVER (W/ DUCT)3 0'3"6"0'3"6" A733 WINDOW JAMB SEPARATION DETAIL @ WALL TYPE 61 0'3"6"0'3"6" A733 WINDOW JAMB DETAIL @ WALL TYPE 64 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018