PROPOSAL
REQUEST
FIELD
OWNER
ARCHITECT
CONTRACTOR
PROJECT: Aspen Ambulance District Facility
OWNER: Pitkin County
123 Emma Road, Suite #106
Basalt, CO 81621
TO: FCI Constructors, Inc.
3070 I-70 Business Loop Building A
Grand Junction, CO 81504
PROPOSAL REQUEST NO: Ten (10)
DATE: September 25, 2018
ARCHITECT'S PROJECT NO: 1740
CONTRACT DATED: May 9, 2018
Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications
to the Contract Documents described herein.
THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED
HEREIN.
General:
1. All exterior handrails to be painted only (delete galvanizing) with the exception of the exterior stair at the
NW corner of the building. This entire stair and handrail is to remain galvanized.
Specifications:
2. Specification 03 3000, Cast-in-Place Concrete: Revise finish on site concrete walls from smooth form liner
finish to sandblast finish. Monument wall to remain as smooth form liner finish.
3. Specification 10 1100 – Visual Display Units: Add paragraph 1.1.A.2:
Visual display board assemblies – field fabricated (tack boards)
4. Specification 10 1100 – Visual Display Units: Add paragraph 2.5:
2.5 VISUAL DISPLAY BOARD ASSEMBLY (field fabricated)
A. Visual Display Board Assembly: Field fabricated.
1. Assembly: tackboard.
2. Corners: Square].
3. Width and height: As indicated on Drawings.
B. Tackboard Panel: Basis-of-Design Forbo Bulletin Board or Architect approved equivalent, ¼”
tackboard panel direct glued to gypsum wall board.
4. Color and Pattern: As selected by Architect from full range of industry colors.
C. Aluminum Frames and Trim: Fabricated from not less than 0.062-inch- (1.57-mm-) thick, extruded
aluminum; standard size and shape.
5. Field-Applied Trim: Manufacturer's standard.
6. Aluminum Finish: Clear anodic.
ARCHITECT: Chamberlin Architects, P.C.
BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#010.1740.doc
D. Joints: Make joints only where total length exceeds maximum manufactured length. Fabricate with
minimum number of joints, as indicated on approved Shop Drawings.
5. Specification 09 6813 Tile Carpeting: Add paragraph 2.4:
2.4 Walk Off Carpet Tile – WCPT
A. Basis-of-Design product Mannington Force Modular carpet tile
B. Color: to be selected from manufacturer’s standard colors
C. Installation Method: Horizontal Brick Ashlar
D. Fiber Content: Type 6,6 Nylon
E. Fiber Type: Solution Dyed
F. Pile Characteristic: Textured Patterned Loop
G. Density: 7,005
H. Backing: Infinity Modular Reinforced Composite Closed Cell Polymer with Recycled Content.
I. Size: 18” x 36”
6. Specification 124813, Entrance Floor Mats and Frames: Delete specification section.
Drawings:
7. Drawing A001, Wall Type 9: Change overall wall thickness from 1’-4 ½” to 1’-5 5/8”.
8. Drawing A001: At exterior wall types (Types 5, 6, 7, 8, 9 & 11):
Change continuous insulation from 4” thick mineral-wool board insulation to 2.5” thick foil-faced
polyisocyanurate board insulation with sealed and taped seams.
Delete fluid-applied weather barrier.
9. Drawing A161:
Change floor finish in Lobby 101 from PCONC/EM to PCONC/WCPT.
Change floor finish in Stair 302 from WD to PCONC.
10. Drawing A601: Modify Details 2 thru 11 as illustrated in the attached reissued Drawing A601.
11. Drawing A612, Detail 7:
Delete wood tread, stair nosing, spacers in concrete to attach wood tread & fastener attached from
below. Tread finish at Stair 302 to be polished concrete (PCONC).
12. Drawing A641: Modify Details 1 thru 4 as illustrated in the attached reissued Drawing A641.
13. Drawing A642: Modify Detail 1 as illustrated in the attached reissued Drawing A642.
14. Drawing A643: Modify Details 1 & 2 as illustrated in the attached reissued Drawing A643.
15. Drawing A644: Modify Details 1 thru 3 as illustrated in the attached reissued Drawing A644.
16. Drawing A651, Detail 5:
Change note WD STAIR TREAD to PCONC STAIR TREAD.
Delete note EXTEND GYP BEHIND TREAD.
17. Drawing A702: Modify Details 1 thru 6 as illustrated in the attached reissued Drawing A702.
18. Drawing A703: Modify Details 14 & 15 as illustrated in the attached reissued Drawing A703.
19. Drawing A721, Interior Window Types: Change glass type at all interior window types from IG-1 to GL-2.
20. Drawing A731: Modify Details 1 thru 7 as illustrated in the attached reissued Drawing A731.
21. Drawing A732: Modify Details 1 thru 3 & 8 as illustrated in the attached reissued Drawing A732.
ARCHITECT: Chamberlin Architects, P.C.
BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#010.1740.doc
22. Drawing A733: Modify Details 1 thru 4 as illustrated in the attached reissued Drawing A733.
23. Drawing S102: Delete depressed slab for entrance mat between Grids H & I.9 and Grids 2 & 3.
Attachments: A601; A641; A642; A643; A644; A702; A703; A731; A732; A733
REVISION
ELEVATION
COLUMN GRID LOCATION
DOOR NUMBER
WINDOW TYPE
CENTER LINE
LINE OF WALL ABOVE OR HIDDEN LINE
BREAK LINE
MATCH LINE
ROOM NAME
ROOM NUMBER
BASIC WALL TYPE
A101
1
2
3
4
A
101A
Room
101
1
A101
TYP
1
A101
TYP
ANGLE
DIAMETER
PERPENDICULAR
PLATE
PLUS OR MINUS
FLOOR DRAIN
FIRE EXTINGUISHERFE
FD
1
1
100' 0"
TOP OF WALL
AL HM
INTERIOR WALL ELEVATION
REFERENCE DRAWING
REFERENCED SECTION NUMBER
SHEET NUMBER
REFERENCED DETAIL NUMBER
SHEET NUMBER
1. COMPLY WITH ALL MANUFACTURERS
RECOMMENDATIONS AND INDUSTRY STANDARDS
RELEVANT TO THE WORK HEREIN.
2. ALL DIMENSIONS ARE FROM FACE OF FINISH UNO.
3. ALL ALIGNMENTS ARE FACE OF FINISH UNO.
4. FIELD VERIFY ALL DIMENSIONS AND ROUGH
OPENINGS PRIOR TO FABRICATION AND/OR
INSTALLATION.
ABV above
ACC accessories
ADJ adjustable
AFF above finished floor
ALT alternate
AL aluminum
APC acoustical panel ceiling
ARCH architect (ural)
ASPH asphalt
A/C air conditioning
BCS baby changing station
BD board
BLDG building
BLKG blocking
BO bottom of
BRG bearing
CBU cemetitious backer unit
CG corner guard
CIP cast in place
CJ control joint
CLG ceiling
CLR clear (ance)
CMU concrete masonry unit
COL column
CONC concrete
CONT continuous or continue
CORR corridor
CPT carpet (ed)
CSMT casement
CT ceramic tile
CTR center
CU condenser unit
CWOG center wall on grid
DBL double
DEMO demolish / demolition
DF drinking fountain
DIM dimension (s)
DIR direction
DISP dispenser
DN down
DR door
DS downspout
DTL detail
DWG drawing
DWR drawer
E east
EA each
EC evaporative cooler
EG etched glass/glazing
EIFS exterior insul finish sys
EJ expansion joint
EL elevation
ELEC electric (al)
EM emergency
EWC electric water cooler
EWG end wall corner guard
EQ equal
EXG existing
EXH exhaust
EXP exposed
EXT exterior
FBO furnished by owner
FD floor drain
FDN foundation
FE fire extinguisher
FEC fire extinguisher cabinet
FEP finished end panel
FFE finished floor elevation
FIN finish
FLG flashing
FLR floor (ing)
FLUR fluorescent
FO face of
FRMG framing
FRP fiber reinforced plastic
FT foot (feet)
FTG footing
GA gage, gauge
GAL gallon
GALV galvanized
GB grab bar
GC general contractor
GL glass, glazing
GWB gypsum wallboard
GYP gypsum
HAS headed anchor stud
HB hose bibb
HCP handicap (ed)
HDR header
HDW hardware
HM hollow metal
HOR horizontal
HR hose reel
HSS hollow structural sections
HT height
HVAC heating /ventilation /air conditioning
HWD hardwood
INCL include (d) (ing)
INSUL insulate (d) (ing)
INT interior
INV invert
JST joist
JT joint
L length, angle
LAM laminate (d)
LAV lavatory
LB pound
LF lineal foot
LG laminated glass, glazing
LIN linoleum
LT light
MA match
MAS masonry
MATL material
MAX maximum
MB marker board
MECH mechanic (al)
MFR manufacture (r) (d)
MH manhole
MIN minimum
MISC miscellaneous
MLD molding, moulding
MO masonry opening
MT mount (ed) (ing)
MTL metal
N north
N/A not applicable
NIC not in contract
NOM nominal
NTS not to scale
NECY necessary
OC on center (s)
OD outside diameter
OFCI owner furnished,
contractor installed
OFD overflow drain
OFOI owner furnished,
owner installed
OH overhead
OL occupant load
OLF occupant load factor
OPG opening
OPH opposite hand
OPP opposite
OSB oriented strand board
OTA open to above
OTS open to structure
PB particle board
PERF perforate (d)
PERIM perimeter
PG pattern glass
PLAM plastic laminate
PLT plate
PNL panel
PNT paint (ed)
PR pair
PROJ projector, projection
PSF pounds per square foot
PSI pounds per square inch
PT pressure treated
PTD paper towel dispenser
PTN partition
PVC polyvinyl cholride
PVMT pavement
PWD plywood
QT quarry tile
R riser, radius
RB rubber base
REC recycling
RCMD recommend (ed) (ations)
RE reference
REF refrigerator
REIN reinforce (d) (ing)
REQ required
REV revision (s), revised
RD roof drain
RFG roofing
RH robe hook
RM room
RO rough opening
ROW right of way
RR restroom
RTU roof top unit
RUB rubber
S south
SAG susp acoustic grid
SC shower curtain rod & hooks
SCH schedule
SD soap dispenser
SHT sheet
SHTG sheathing
SIM similar
SND sanitary napkin dispenser
SNV sanitary napkin vendor
SPEC specification
SPKR speaker
SQ square
SS solid surface
SST stainless steel
STD standard
STL steel
STOR storage
STR structural
SUSP suspended
T tread
TB towel bar
TEL telephone
TG tempered glass
THK thick
T.O.top of
TOC top of concrete
TOS top of steel
TOW top of wall
TPD toilet paper dispenser
TS tube steel
TYP typical
T&G tongue and groove
UCR undercounter refigerator
UNO unless noted otherwise
VB vapor barrier
VCT vinyl composition tile
VERT vertical
VIF verify in field
VM vending machine
VNL vinyl sheet
VTR vent through roof
W west, wide, width
W/with
WB wood base
WC watercloset
WD wood
WDW window
WF wide flange
WG wire glass
W/O without
WP waterproof (ing)
WR waste receptacle
WRB weather resistive barrier
WWM welded wire mesh
WALL TYPE NOTES:
1. ALL EXTERIOR WALL TYPES ARE SHOWN WITH
THE EXTERIOR WALL FACING RIGHT UNLESS
OTHERWISE NOTED.
2. PROVIDE GLASS MAT WATER-RESISTANT BACKER
BOARD IN LIEU OF GYPSUM WALL BOARD BEHIND
ALL WALL TILE.
3. GYPSUM BOARD SHALL BE MOISTURE-RESISTANT
AT THE FOLLOWING LOCATIONS: WALLS AND
CEILINGS OF ALL RESTROOMS AND SHOWERS
4. WALL TYPE CHANGES OCCUR AT CORNERS OR
INTERSECTIONS OF WALLS UNLESS NOTED
OTHERWISE.
3-5/8" MTL STUDS
@ 16" O.C.
5/8" GYP BD, EA SIDE.
(ONE SIDE @ 1A)
SOUND ATTN BATTS
5"
ACOUSTICAL SEALANT,
EA SIDE. FIRE CAULK IN
LIEU OF @ FIRE
RARTED LOCATIONS
MTL RUNNER CHANNEL
FLOOR LINE1/2"METAL DECK
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
CONT FIRE
CAULK GWB TO
DISSIMILAR
MATERIALS, EA
SIDE
UL -U419 -1/2 HR RATED, STC: 49
6" MTL STUDS
@ 16"O.C.
5/8" GYP BD, EA SIDE
(ONE SIDE @ 2A)
SOUND ATTN
BATTS
7 1/4"
METAL DECK
ACOUSTICAL
SEALANT, EA SIDE
MTL RUNNER CHANNEL
FLOOR LINE1/2"CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
1"UL -U419 -1 HR RATED @ STAIR & ELEVATOR
6" MTL STUDS @ 16" O.C.
5/8" GYP BD
1/2" EXT SHEATHING
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
AIR SPACE
4" CMU VENEER
1' - 4 1/4"
VAPOR BARRIER
MASONRY VENEER
TIES @ 16" VERTICALLY
& HORIZONTALLY
6" MTL STUDS @ 16" O.C.
(10" @ 6A)
5/8" GYP BD
1/2" EXT SHEATHING
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
PRE-FINISHED HORIZONTAL MTL
PNL ATTACHED TO THERMALLY
BROKEN 'Z' CLIPS SPACED
VERTICALLY @ 24" O.C.
VAPOR BARRIER
8" CIP CONC, RE: STR
GL
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
OMIT WEATHER BARRIER & XPS INSULATION @
WALL TYPE 8A
10 1/2"
11" @ 3A
10"
(2) 3-5/8" MTL
STUDS @ 16" O.C.
5/8" GYP BD,
EA SIDE
SOUND ATTN
BATTS
ACOUSTICAL
SEALANT, EA SIDE.
FIRE CAULK IN LIEU
OF @ FIRE RARTED
LOCATIONS
MTL RUNNER CHANNEL
FLOOR LINE
METAL DECK
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
UL -U493 -1 HR RATED, STC-59
CONT FIRE
CAULK GWB TO
DISSIMILAR
MATERIALS, EA
SIDE
1 - 1/2" AIR SPACE (2
1/2" @ 3A)
ALUM STOREFRONT,
NON-THERMALLY
BROKEN
UNINSULATED GLAZING
METAL DECK
1"4 1/2" (6" @ 4A)
ACOUSTICAL
SEALANT, EA SIDE
FLOOR LINE
WALL TYPE ABV,
1 @ 4 1/2", 2 @ 6"2
1
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
6" MTL STUDS SISTERED TO
6" MTL STUDS @ 16" O.C.
5/8" GYP BD
1/2" EXT SHEATHING.
5/8" EXT SHEATHING @ 7A
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
PRE-FINISHED VERTICAL MTL
PNL ATTACHED TO THERMALLY
BROKEN 'Z' GIRTS SPACED
HORIZONTALLY @ 24" O.C.
VAPOR BARRIER
1' - 4 3/4"
UL -U419 -1 HR RATED @ 7A
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
8" CONC (12" CONC
@ 9A), RE: STR
AIR SPACE
4" CMU VENEER
1' - 5 5/8"
1-HR RATED, per TABLE 721.1(2), 4-1.1.
MASONRY VENEER TIES
@ 16" VERTICALLY &
HORIZONTALLY
GL
8" CMU, RE: STR
7/8" MTL FURRING
CHANNELS @ 16" O.C.
@ 10A
5/8" GYP BD @ 10A
9 1/4"
6" MTL STUDS
@ 16"O.C.
5/8" GYP BD, EA SIDE
SOUND ATTN
BATTS
7 3/4"
METAL DECK
ACOUSTICAL
SEALANT, EA SIDE
MTL RUNNER CHANNEL
FLOOR LINE1/2"1/2" PWD
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
2.5" THK (R-15 MIN) RIGID
INSULATION W/ TAPED &
SEALED SEAMS
8" CMU, RE: STR
AIR SPACE
4" CMU VENEER
1' - 4 1/2"
MASONRY VENEER
TIES @ 16" VERTICALLY
& HORIZONTALLY
6" MTL STUDS @ 16"O.C.
5/8" GYP BD, ONE SIDE
SOUND ATTN BATTS
METAL DECK
ACOUSTICAL SEALANT,
EA SIDE
MTL RUNNER CHANNEL
FLOOR LINE1/2"4" CMU VENEER
1/2" PWD.
5/8" EXT SHEATHING @ 2D
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
MASONRY VENEER
TIES @ 16" VERTICALLY
& HORIZONTALLY
1' - 0 3/4"
UL -U419 -1 HR RATED @ 2D
12" CIP CONC,
RE: STR
GL
ACOUSTICAL
SEALANT, ONE
SIDE.
FLOOR LINE
METAL DECK
CONT COMPRESSIBLE
INSULATION IN DECK
FLUES
ACOUSTICAL
SEALANT, ONE
SIDE.
7/8" MTL FURRING
CHANNEL @ 16"
O.C.
5/8" GYP BD, ONE
SIDE.
NOT USED
2-1/2" MTL STUDS
@ 16" O.C.
5/8" GYP BD, ONE SIDE
ACOUSTICAL SEALANT,
ONE SIDE.
MTL RUNNER CHANNEL
FLOOR LINE
METAL DECK
CONT COMPRESSIBLE
INSULATION IN DECK FLUES
MTL STUD SLIP TRACK
@ METAL DECK
ACOUSTICAL
SEALANT, ONE
SIDE.
FULLY ADHERED SINGLE PLY
ROOF MEMBRANE
1/2" COVER BOARD
R-35 RIGID INSULATION
VAPOR BARRIER
MTL ROOF DECK, RE: STR
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt11/6/2018 10:08:34 AMA001
OCTOBER 16,
2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
NOTES, SYMBOLS,
ABBREVIATIONS
AND WALL TYPES
PROJECT STATUS: 100% CD
SH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
SYMBOLS GENERAL NOTESARCHITECTURAL ABBREVIATIONS
0'6"1'0'6"1'
A001
WALL TYPES1
WALL TYPE 1 & 1A WALL TYPE 2 & 2A WALL TYPE 5 WALL TYPE 6 & 6A
WALL TYPE 8 & 8A
WALL TYPE 3 & 3A WALL TYPE 4 & 4A
WALL TYPE 7 &7A WALL TYPE 9 & 9A WALL TYPE 10 & 10A
WALL TYPE 2B
WALL TYPE 11
WALL TYPE 2C & 2D
WALL TYPE 12
WALL TYPE 1B
WALL TYPE 13 WALL TYPE 14
CLASS 'A' ROOF ASSEMBLY
NO: ISSUED FOR: DATE:
2 Response to City of Aspen
Review Comments
7/16/18
6PR#010 9/25/18
CONC FOUNDATION,
RE: STR
RIGID PERIMETER
INSULATION
FOUNDATION
WATERPROOFING
CONC DRIVEWAY W/
SNOWMELT, RE: CIVIL
CONT GALV MTL THRU
WALL FLASHING & WEEPS
1" RIGID INSULATION @
SNOWMELTED SLAB EDGE
& 2" BELOW SLAB
WEATHER BARRIER
FLASHING OVER MTL
FLASHING FLANGE
5
CONT SEALANT (TYP)
6
CONC FOUNDATION
WALL, RE: STR
RIGID PERIMETER
INSULATION
FOUNDATION
WATERPROOFING
CAPILARY BREAK
PERIMETER FOUNDATION
DRAIN W/ FILTER FABRIC,
RE: CIVIL
7
6 WEATHER BARRIER FLASHING, LAP
6" DOWN WALL & 3" UP BEHIND MTL
DRIP FLASHING
PRE FINISHED MTL DRIP FLASHING
W/ HEMMED EDGE
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN 'C' GIRT W/
WEEP HOLES
WEATHER BARRIER FLASHING, LAP
OVER MTL SILL FLASHING FLANGE
LAP WEATHER BARRIER OVER
WEATHER BARRIER FLASHING
PRE FINISHED MTL EDGE CAP, RIVET
TO MTL PANEL @ 12" O.C. W/ CONT
SEALANT TAPE
6
PRE FINISHED MTL CORNER
W/ HEMMED EDGES
RIVET CONNECTION @ 12"
O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN
'C' GIRTS @ INSULATION PERIMETER
FOR ATTACHMENT POINTS
6TYP4"11
6
7
6
WEATHER BARRIER FLASHING
PRE FINISHED MTL SILL FLASHING
W/ CONT GALV CLEAT
THERMALLY BROKEN 'C' GIRT
CONT PT WD 2x BLK'G, SLOPE TOP
SLOPE 3/4"2 1/2"PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN 'C' GIRT
WEATHER BARRIER FLASHING, LAP
OVER MTL SILL FLASHING FLANGE
6
7
5
CONT BACKER ROD
& SEALANT (TYP)
PRE FINISHED MTL
EDGE CAP, RIVET TO
MTL PANEL @ 12" O.C.
W/ CONT SEALANT
TAPE
THERMALLY
BROKEN 'C' GIRT
WEATHER BARRIER
FLASHING, LAP 6"
DOWN WALL & 3" UP
BEHIND MTL DRIP
FLASHING
6
CONC FOUNDATION,
RE: STR
RIGID PERIMETER
INSULATION
FOUNDATION
WATERPROOFING
CONC DRIVEWAY W/
SNOWMELT, RE: CIVIL
CONT GALV MTL THRU
WALL FLASHING & WEEPS
1" RIGID INSULATION @
SNOWMELTED SLAB EDGE
& 2" BELOW SLAB
WEATHER BARRIER
FLASHING OVER MTL
FLASHING FLANGE
11
CONT SEALANT (TYP)
6
7
9A
141 3/4"WEATHER BARRIER FLASHING,
LAP 6" DOWN WALL & 3" UP
BEHIND MTL DRIP FLASHING
PRE FINISHED MTL SILL FLASHING
W/ CONT GALV CLEAT, SLOPE
TOP 1/2"
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN 'C' GIRT
WEATHER BARRIER FLASHING, LAP
OVER MTL SILL FLASHING FLANGE
CONT PT WD BLK'G
6
6
2 1/2"5
2
4
CONT PT WD BLK'G, SLOPE TOP
WEATHER BARRIER FLASHING,
LAP 6" DOWN WALL, OVER 2x
SILL BLKG ABOVE & 3" UP WALL
PRE FINISHED MTL SILL FLASHING W/
CONT GALV CLEAT, SLOPE TOP 3/4"
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN 'C' GIRT
WEATHER BARRIER FLASHING, LAP
OVER MTL SILL FLASHING FLANGE
CONT PT WD BLK'G
6
3/4" PWD BLOCKING
7
6 TYP4"PRE FINISHED MTL CORNER
W/ HEMMED EDGES
RIVET CONNECTION @ 12"
O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN
'C' GIRTS @ INSULATION PERIMETER
FOR ATTACHMENT POINTS
MTL 'Z' FURRING @ CUT PANEL LOCATIONS
FOR ATTACHMENT (TYP)
ALIGN W/ SOFFIT HEADER ABOVE CTR MTL PANEL JOINT ON WALL SEGMENT
6" MTL STUD FRM'G W/ WALL TYPE 7 FINISH
PRE FINISHED MTL EDGE CAP, RIVET TO
MTL PANEL @ 12" O.C. W/ CONT SEALANT
TAPE
RIVET CONNECTION @ 12"
O.C. W/ CONT SEALANT TAPE
CONT BACKER ROD & SEALANT (TYP)
1/2" PWD BLK'G @ COLUMN
STL COLUMN, RE: STR
6
7
CONC FOUNDATION, RE: STR
RIGID PERIMETER INSULATION
FOUNDATION WATERPROOFING
CONC RAMP, RE: CIVIL
CONT GALV MTL THRU WALL
FLASHING & WEEPS
WEATHER BARRIER FLASHING
OVER MTL FLASHING FLANGE
CONT SEALANT (TYP)
GROUT CAVITY SOLID BELOW
FLASHING
6
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:17 AMA601
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
EXTERIOR DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A601
TOP OF FOUNDATION @ 6" MTL STUD WALL2
0'6"1'0'6"1'
A601
FOUNDATION WALL1
0'3"6"0'3"6"
A601
METAL WALL TRANSITION HEAD9
0'3"6"0'3"6"
A601
METAL WALL TRANSITION CORNER10
0'3"6"0'3"6"
A601
METAL WALL TRANSITION SILL5
0'3"6"0'3"6"
A601
METAL WALL TRANSITION TO CMU JAMB8
0'3"6"0'3"6"
A601
TOP OF FOUNDATION WALL @ CMU3
0'3"6"0'3"6"
A601
METAL WALL TRANSITION TO CMU SILL 27
0'3"6"0'3"6"
A601
METAL WALL TRANSITION TO CMU SILL6
0'3"6"0'3"6"
A601
METAL WALL TRANSITION CORNER 211
0'3"6"0'3"6"
A601
WEEPS & FLASHING DETAIL @ GRADE4
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
4"ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
PRE FINISHED MTL ROOD EDGE
FLASHING W/ CONT GALV CLEAT
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & DOWN FASCIA
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PT WD 2x BLK'G (TYP)
CONT SEALANT TO DECK (TYP)
STL STUD ROOF FRM'G, RE: STR
ROOF MEMBRANE FULLY ADHERED
TO SUBSTRATE
1/2" EXT SHEATHING ON RIGID INSULATION
W/ MTL 'Z' GIRTS @ 16" O.C. ON 1/2" PWD
SHEATHING ON 6" MTL STUD FRM'G W/ BATT
INSULATION W/ 5/8" GWB
6
6
6" X 6" PRE FINISHED MTL GUTTER,
COLOR TO MATCH ADJACENT MTL PNL
PRE-FINISHED VERTICAL MTL PNL
ATTACHED TO THERMALLY BROKEN 'Z'
GIRTS SPACED VERTICALLY @ 12" O.C.
PRE FINISHED MTL DRIP EDGE
FLASHING
MTL "C" GIRT
ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
SINGLE PLY ROOF MEMBRANE,
LAP DOWN FASCIA
1/2" COVER BOARD ON RIGID
INSULATION
TPO-COATED STL BASE PLATE
SST PIPE SNOW GUARDS
(TYP OF 2)
STL BEAM, RE: STR
1 ' - 4 "
1 ' - 4 "2 1/2"PRE FINISHED MTL EDGE CAP, RIVET
TO MTL PANEL
VAPOR BARRIER
7
SAG CLG, RE: RCP
PRE FINISHED MTL FLASHING, LAP UP
BEHIND GUTTER
6
1 0
4"7
ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
PRE FINISHED MTL ROOD EDGE
FLASHING W/ CONT GALV CLEAT
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & DOWN FASCIA
WEATHER BARRIER FLASHING, LAP
OVER TOP OF PARAPET
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PT WD 2x BLK'G (TYP)
SINGLE PLY ROOF MEMBRANE ON 1/2"
COVER BOARD ON RIGID INSULATION
VAPOR BARRIER
CONT SEALANT TO DECK (TYP)
6
J
7
ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
PRE FINISHED MTL ROOD EDGE
FLASHING W/ CONT GALV CLEAT
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & DOWN FASCIA
WEATHER BARRIER FLASHING, LAP
OVER TOP OF PARAPET
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PT WD 2x FRM'G (TYP)
SINGLE PLY ROOF
MEMBRANE ON 1/2" COVER
BOARD ON RIGID INSULATION
VAPOR BARRIER
SLOPES
T.O. ROOF EDGE
1-5/8" MTL STUD FRM'G @ 16" O.C. IN
BEAM FLANGE W/ BATT INSULATION
CONT SEALANT TO DECK (TYP)
6"
6
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:19 AMA641
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
ROOF DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'6"1'0'6"1'
A641
ROOF DETAIL @ ELEVATOR4
0'3"6"0'3"6"
A641
ROOF GUTTER2
0'3"6"0'3"6"
A641
ROOF EDGE FLASHING - NORTH1
0'3"6"0'3"6"
A641
ROOF EDGE FLASHING - EAST/WEST3
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
12 0
5
LAP WEATHER BARRIER FLASHING
OVER MTL FLASHING FLANGE
LAP WEATHER BARRIER OVER WEATHER
BARRIER FLASHING
PRE FINISHD MTL THRU WALL FLASHING
W/ CONT GALV CLEAT & WEEPS
3"GROUT CAVITY SOLID BELOW WEEPS
& FLASHING
FULLY ADHERE ROOF MEMBRANE TO
SUBSTRATE & LAP BEHIND FLASHING CLEAT
CONT CANT
ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
PRE FINISHED MTL ROOD EDGE
FLASHING W/ CONT GALV CLEAT
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & DOWN FASCIA
4"2
2
2
6
6
10
WEATHER BARRIER FLASHING, LAP
OVER TOP OF PARAPET
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PRE FINISHED MTL FASCIA W/ FLAT
LOCK SEAM @ VERTICAL JOINTS
113' - 4 1/2"
T.O. CANOPY
26
24
24
2
624
111' - 7 1/4"
B.O. CANOPY
2.5" RIGID INSULATION @ FASCIA &
SOFFIT
PT WD 2x BLK'G (TYP)
CONT PT WD 2x @ CANOPY SOFFIT
PERIMETER
WRAP PRE FINISHED MTL FASCIA
FLASHING OVER BLK'G & ATTACH
BELOW SOFFIT FINISH
CONT BACKER ROD & SEALANT (TYP)
1x6 WD PLANK SOFFIT FINISH ON 3" MTL 'Z' GIRTS
W/ RIGID INSULATION
WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8"
MTL FURRING ATTACHED TO STL BEAMS, RE: STR
FILL CANOPY CAVITY W/ BATT INSULATION
SINGLE PLY ROOF MEMBRANE ON 1/2" COVER
BOARD ON TAPERED RIGID INSULATION ON MTL
ROOF DECK, RE: STR
GWB ON RIPPED WD 2x6 FRM'G @ 16" O.C.
LAP WEATHER BARRIER OVER MTL
FLASHING FLANGE
PRE FINISHED MTL FLASHING DRIP
EDGE W/ CONT HEMMED EDGE
CONT BACKER ROD & SEALANT,
EA SIDE (TYP)
WEATHER BARRIER FLASHING, LAP
INTO OPENING
ALUM STOREFRONT
CONT SEALANT (TYP)
MTL STUD HEADER, RE: STR
4' - 3"
6
6
ALUM BRK MTL TO MATCH STOREFRONT
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:20 AMA642
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
ROOF DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A642
CANOPY SECTION1
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
J
4"1/2"
SLOTTED STL ANGLE @ SCUPPER
FOR 2x ATTACHMENT
26
5
2' - 7"
LAP WEATHER BARRIER FLASHING
OVER MTL FLASHING FLANGE
PRE FINISHD MTL THRU WALL FLASHING
W/ CONT GALV CLEAT & WEEPS
GROUT CAVITY SOLID BELOW WEEPS
& FLASHING
FULLY ADHERE ROOF MEMBRANE TO
SUBSTRATE & LAP BEHIND FLASHING CLEAT
CONT CANT
SINGLE PLY ROOF MEMBRANE ON 1/2" COVER
BOARD ON TAPERED RIGID INSULATION ON MTL
ROOF DECK, RE: STR3"SLOPE
ROOF FLASHING MEMBRANE W/ CONT EDGE
SEALANT, CTR OVER FLASHING STRIP BELOW
ROOF FLASHING MEMBRANE, CTR ON END
OF SCUPPER SLEEVE BELOW
WELDED & PRE FINISHED MTL SCUPPER
SLEEVE W/ DRIP EDGE, EXTEND 2-1/2"
BEHIND ROOF MEMBRAN FLASHING
RETURNS @ SCUPPER SIDES. COLOR TO
MATCH ADJACENT ROOF EDGE
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & 1" DOWN FASCIA
PANEL, ADHERE
WEATHER BARRIER FLASHING, LAP
OVER TOP OF PARAPET
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PRE FINISHED MTL FASCIA W/ FLAT
LOCK SEAM @ VERTICAL JOINTS
2.5" RIGID INSULATION @ FASCIA &
SOFFIT
CONT PT WD 2x @ CANOPY SOFFIT
PERIMETER
WRAP PRE FINISHED MTL FASCIA
FLASHING OVER BLK'G & ATTACH
BELOW SOFFIT FINISH
CONT BACKER ROD & SEALANT (TYP)
1x6 WD PLANK SOFFIT FINISH ON 3" MTL 'Z' GIRTS
W/ RIGID INSULATION
WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8"
MTL FURRING ATTACHED TO STL BEAMS, RE: STR
FILL CANOPY CAVITY W/ BATT INSULATION
LAP WEATHER BARRIER OVER MTL
FLASHING FLANGE
PRE FINISHED MTL FLASHING DRIP
EDGE W/ CONT HEMMED EDGE
CONT BACKER ROD & SEALANT,
EA SIDE (TYP)
WEATHER BARRIER FLASHING, LAP
INTO OPENING
ALUM STOREFRONT
CONT SEALANT (TYP)
MTL STUD HEADER, RE: STR
6
6
6
6" X 6" PRE FINISHED MTL GUTTER,
COLOR TO MATCH ADJACENT MTL PNL
PRE-FINISHED VERTICAL MTL PNL
ATTACHED TO THERMALLY BROKEN 'Z'
GIRTS SPACED VERTICALLY @ 12" O.C.
PRE FINISHED MTL DRIP EDGE FLASHING
MTL "C" GIRT
ROOF MEMBRANE FLASHING W/ CONT
EDGE SEALANT
SINGLE PLY ROOF MEMBRANE, LAP DOWN
FASCIA
1/2" COVER BOARD ON RIGID INSULATION
TPO-COATED STL BASE PLATE
SST PIPE SNOW GUARDS (TYP OF 2)
STL BEAM, RE: STR
PRE FINISHED MTL EDGE CAP, RIVET TO
MTL PANEL
VAPOR BARRIER 2 1/2"PRE FINISHED MTL FLASHING, LAP UP
BEHIND GUTTER
PRE FINISHED MTL EDGE CAP W/ WEEP
HOLES, RIVET TO MTL PANEL
PRE FINISHED BRK MTL FLASHING CLOSURE
PRE FINISHED MTL DRIP FLASHING W/
HEMMED EDGE
WD 1x6 SOFFIT ON 7/8" MTL FURRING
PRE FINISHED BRK MTL SOFFIT W/ FLAT
LOCK JOINTS
WEATHER BARRIER ON 1/2" EXT SHEATHING
ON 7/8" MTL FURRING
PRE FINISHED MTL FASCIA FLASHING W/
HEMMED EDGE & CONT GALV CLEAT, FASTEN
BEHIND WD SOFFIT
1/2" EXT SHEATHING ON 3-5/8" MTL STUDS @
16" O.C. ATTACHED TO STL BEAM, RE: STR
6
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:21 AMA643
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
ROOF DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A643
CANOPY SCUPPER DETAIL1
0'3"6"0'3"6"
A643
ROOF DETAIL - SOUTH @ SOFFIT2
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
C
6
MTL 'C' GIRT W/ WEEP HOLES @ 8" O.C.
PRE FINISHED MTL PANE EDGE TRIM W/
WEEPS BY MTL PANEL INSTALLER
PRE FINISHED MTL THRU WALL FLASHING W/
CONT GALV CLEAT & WEEPS
CONC PAVER ON ADJUSTABLE PEDESTAL
SYSTEM
ROOF MEMBRANE ON 1/2" COVER BOARD ON
HIGH DENSITY RIGID INSULATION
STL BEAM & MTL DECK, RE: STR
PT WD 2x4 FRM'G @ 16" O.C., FILL CAVITIES
W/ RIGID INSULATION
3"3"FLASHING RETURN UP WALL1' - 0" PRE FINISHED MTL THRU WALL6
E
14
5
6 1/4"3"
PRE FINISHD MTL THRU WALL FLASHING
W/ CONT GALV CLEAT & WEEPS
ROOF MEMBRANE ON 1/2" COVER BOARD
ON HIGH DENSITY RIGID INSULATION
CONC PAVER ON ADJUSTABLE PEDESTAL
SYSTEM
GROUT CAVITY SOLID BELOW WEEPS & FLASHING
STL SHIMS @ CMU BLOCK, RE: STR
CONT PT WD 2x4 BLK'G @ 16" O.C., FILL CAVITIES
W/ RIGID INSULATION 3"6
7
6"5"2"1' - 0"3' - 6"CONT STL 2"x2" TUBE TOP RAIL&
VERTICALS @ 48" O.C.
STL 2"x1/2" HORIZONTAL BARS SPACED
@ 4" O.C. & WELDED TO 2"x2" VERTICALS
TYP4"ROOF MEMBRANE ON 1/2" COVER
BOARD ON HIGH DENSITY RIGID
INSULATION
CONC PAVER ON ADJUSTABLE
PEDESTAL SYSTEM
SINGLE PLY ROOF MEMBRANE FULLY
ADHERED TO 1/2" EXT SHEATHING
SUBSTRATE
LAP ROOF MEMBRANE OVER
PARAPET & DOWN FASCIA
WEATHER BARRIER FLASHING,
LAP OVER PARAPET & 6" DOWN
WALL BEHIND RIGID INSULATION
PRE FINISHED MTL PARAPET
COPING W/ CONT CLEAT
CONT BACKER ROD & SEALANT
(TYP)
(2) LAYERS 3/4" PWD ATTACHED
TO CONC
STL WELD PLATE, RE: STR
4"x12"x3/8" STL PLATE @ 48" O.C.
ALIGN WITH MASONRY JOINTS (TYP)
9
6
4
3"ALUM STOREFRONT W/ CONT SUB
SILL IN CONT SEALANT BED
PRE FINISHED MTL FLASHING W/
CONT GALV CLEAT
TYP
1"
CONC PAVER ON ADJUSTABLE
PEDESTAL SYSTEM
ROOF MEMBRANE ON 1/2" COVER BOARD
ON HIGH DENSITY RIGID INSULATION
STL BEAM & MTL DECK, RE: STR
PT WD 2x4 FRM'G @ 16" O.C., FILL CAVITIES
W/ RIGID INSULATION
VAPOR BARRIER, LAP UP WALL
4 1/2"1"
5"
1/2" EXT SHEATHING ON 1-5/8" MTL STUD
FRM'G @ 16" O.C.
CONT CANT
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:23 AMA644
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
DECK DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A644
DECK DETAIL - WEST1
0'3"6"0'3"6"
A644
DECK DETAIL - EAST2
0'3"6"0'3"6"
A644
DECK - RAIL DETAIL3
0'3"6"0'3"6"
A644
DECK DETAIL - NORTH4
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
7
CONT BACKER ROD &
SEALANT (TYP)
HM FRAME, PNT
DOOR, RE: SCHED4"CONT SEALANT (TYP)
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT SEALANT TAPE
THERMALLY BROKEN 'C' GIRT
WEATHER BARRIER FLASHING, LAP
OVER MTL SILL FLASHING FLANGE
PRE FINISHED MTL FLASHING W/
WEEP HOLES
PRE FINISHED MTL DRIP FLASHING
W/ HEMMED EDGE
6
PRE FINISHED MTL TRIM
7
CONT BACKER ROD &
SEALANT (TYP)
HM FRAME, PNT
DOOR, RE: SCHED2"CONT SEALANT (TYP)
PRE FINISHED MTL EDGE
CAP, RIVET TO MTL PANEL
@ 12" O.C. W/ CONT
SEALANT TAPE
THERMALLY BROKEN 'C' GIRT
PRE FINISHED MTL FLASHING
2"
6
9
CONT BACKER ROD &
SEALANT (TYP)
HM FRAME, PNT
DOOR, RE: SCHED4"STL ANGLE, RE: STR (PNT)
CONT
SEALANT (TYP)
WEATHER BARRIER OVER
WEATHER BARRIER
FLASHING
WEATHER BARRIER
FLASHING
THROUGH WALL WEEPS
& FLASHING
1' - 3"
6
9
CONT BACKER ROD &
SEALANT (TYP)
WEATHER BARRIER
FLASHING
HM FRAME, PNT
DOOR, RE: SCHED
GL
CONT
SEALANT (TYP)
BULLNOSE EDGE
2"2"
6
11
WEATHER BARRIER OVER WEATHER
BARRIER FLASHING
STL ANGLE & PLATE, RE: STR (PNT)
OH DOOR, RE: SCHED
0
WEATHER BARRIER FLASHING
THROUGH WALL WEEPS
& FLASHING
GROUT CAVITY SOLID BELOW
FLASHING
6
11
OH DOOR, RE: SCHEDULE
0
CONT BACKER ROD &
SEALANT
RETURN CMU
VENEER @ JAMB
6" DIA CONCRETE
FILLED BOLLARD.
ALIGN WITH DOOR
OPENING
1
1' - 0"1' - 6"
BULLNOSE EDGE 3"1
1/2"2"SEALANT, EA
SIDE (TYP)
HM FRAME,
PNT
DOOR, RE:
SCHED
2
1
1/2"2"SEALANT, EA
SIDE (TYP)
HM FRAME,
PNT
DOOR, RE:
SCHED
2
3
2"SEALANT, EA
SIDE (TYP)
HM FRAME,
PNT
DOOR, RE:
SCHED
3
2"SEALANT, EA
SIDE (TYP)
HM FRAME,
PNT
DOOR, RE:
SCHED
2
OVERHEAD
DOOR, RE:
SCHED
MTL STUD
HEADER, RE:
STRUC
2
DOOR, RE:
SCHED
CORNER GAURD
@ BOTH SIDES
DOUBLE STUD AT
JAMB, TYP.
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:25 AMA702
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
DOOR DETAILS
PROJECT STATUS: 100% CD
KH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A702
HM DOOR HEAD @ WALL TYPE 73
0'3"6"0'3"6"
A702
HM DOOR JAMB @ WALL TYPE 74
0'3"6"0'3"6"
A702
HM DOOR HEAD @ WALL TYPE 91
0'3"6"0'3"6"
A702
HM DOOR JAMB @ WALL TYPE 92
0'3"6"0'3"6"
A702
OH DOOR HEAD @ WALL TYPE 55
0'3"6"0'3"6"
A702
OH DOOR JAMB @ WALL TYPE 56
0'3"6"0'3"6"
A702
HM DOOR HEAD @ WALL TYPE 1 & 27
0'3"6"0'3"6"
A702
HM DOOR JAMB @ WALL TYPE 1 & 28
0'3"6"0'3"6"
A702
HM DOOR HEAD @ WALL TYPE 39
0'3"6"0'3"6"
A702
HM DOOR JAMB @ WALL TYPE 310
0'3"6"0'3"6"
A702
OH DOOR HEAD @ WALL TYPE 211
0'3"6"0'3"6"
A702
OH DOOR JAMB @ WALL TYPE 212
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
6
METAL
TRANSITION
STRIP, CENTER
UNDER DOOR
@ FLR'G OF DIFF
HGTS, RE: SPECS
DOOR,
RE: SCHED
PCONC,
RE: FINISH
PLANS
CT
METAL TRANSITION
STRIP, CENTER
UNDER DOOR @
FLR'G OF DIFF HGTS,
RE: SPECS
DOOR,
RE: SCHE
CPT, RE: FINISH
PLANS
CT
MTL TRANSITION
STRIP, RE; SPECS RUB
DOOR,
RE: SCHED
ALUM DOOR,
RE: SCHED
ALUM THRESHOLD,
SET IN FULL
SEALANT BED
CPT
FLOOR FINISH,
RE: FINISH PLANS
ALUM DOOR,
RE: SCHED
ALUM THRESHOLD,
SET IN FULL
SEALANT BED
TRANSITION STRIP,
CENTER UNDER
DOOR, RE: SPECS
CPT
DOOR,
RE: SCHED
FLOOR FINISH,
RE: FINISH PLANS
DOOR,
RE: SCHED
ALUM THRESHOLD
IN CONT SEALANT
BEDANGLE (TYP)SST GRATING
CARPET INSERT
5/8"10
CONT SEALANT & BACKER
ROD, EA SIDE (TYP)
HM FRAME, W/ EQ
RABBETS (PNT)
BOND BEAM, RE: STR
GL
DOOR, RE: SCHED2"MATCH CMU DEPTH
10
CONT SEALANT & BACKER
ROD, EA SIDE (TYP)
HM FRAME W/ EQ
RABBETS (PNT)2"MATCH CMU DEPTH
MASONRY FRAME ANCHOR
GL
DOOR, RE: SCHED2"DOOR,
RE: SCHED
ALUM THRESHOLD
IN CONT SEALANT
BED
2C
GL
CONT
SEALANT (TYP)
STL ANGLE,
RE: STR (PNT)HM FRAME,
PNT
DOOR, RE:
SCHED
9 1/4"2"2"
2C
PROVIDE DOUBLE
STUDS @ JAMBS
PERPENDICULAR
WALL
GL
SEALANT
2"9 1/4"
5
GL
CONT BACKER ROD &
SEALANT (TYP)
HM FRAME, PNT
DOOR, RE: SCHED4"STL ANGLE, RE: STR (PNT)
CONT
SEALANT (TYP)
WEATHER BARRIER OVER
WEATHER BARRIER
FLASHING
WEATHER BARRIER
FLASHING
THROUGH WALL WEEPS
& FLASHING
1' - 2"
2"
6
5
GL
BACKER ROD & SEALANT
DOOR, RE:
SCHED
WRAP WEATHER BARRIER INTO
OPENING AND SEAL
SEALANT
1' - 2"2"2"
6
WEATHER BARRIER
FLASHING
CASEWORK
SIDELITE RAIL,
RE: SPECS
WD BASE W/
CHAMFERED
EDGE
SIDELITE
DOOR, RE: SCHED
ALIGN RAIL W/
WALL FACE
1 1 1/4"4"
1
DOOR, RE:
SCHED
1 1/4"
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:27 AMA703
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
DOOR DETAILS
PROJECT STATUS: 100% CD
SH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CT TO PCONC2
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CT TO CPT6
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CONC TO RUB5
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ STOREFRONT A1
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CPT TO PCONC (ALUM DOOR)4
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CPT TO PCONC3
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ GRADE7
0'3"6"0'3"6"
A703
WALK-OFF MAT9
0'3"6"0'3"6"
A703
HM DOOR HEAD @ CMU11
0'3"6"0'3"6"
A703
HM DOOR JAMB @ CMU10
0'3"6"0'3"6"
A703
DOOR THRESHOLD @ CPT & GRADE8
0'3"6"0'3"6"
A703
DOOR HEAD @ WALL TYPE 2C13
0'3"6"0'3"6"
A703
DOOR JAMB @ WALL TYPE 2C12
0'3"6"0'3"6"
A703
DOOR HEAD @ WALL TYPE 514
0'3"6"0'3"6"
A703
DOOR JAMB @ WALL TYPE 515
0'3"6"0'3"6"
A703
DOOR JAMB (SLIDING) @ WALL TYPE 117
0'3"6"0'3"6"
A703
SLIDING DOOR HEAD @ WALL TYPE 116
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
5
ALUM STOREFRONT W/ CONT SUB
SILL IN CONT SEALANT BED
SLOPE 3/4"PRE FINISHED MTL SILL FLASHING
W/ CONT GALV CLEAT
2 1/2"CONT PT WD 1x BLK'G
3/4" PWD BLOCKING
CONT BACKER ROD & SEALANT (TYP)
CONT SEALANT (TYP)
WD SILL W/ EASED EDGES
1/2"
CONT SEALANT FROM GWB TO SILL (TYP)
MTL 'C' GIRT
6
WEATHER BARRIER FLASHING, LAP 6" DOWN
WALL & OVER SILL BLKG INTO OPENING
7
WEATHER BARRIER FLASHING,
LAP 6" DOWN WALL
ALUM STOREFRONT W/ CONT SUB SILL
IN CONT SEALANT BED
PRE FINISHED MTL SILL FLASHING
W/ CONT GALV CLEAT
CONT PT WD BLK'G
SLOPE 3/4"
WD SILL W/ EASED
EDGES
CONT SEALANT (TYP)
THERMALLY BROKEN 'C' GIRT
CONT SEALANT FROM
GWB TO SILL (TYP)
CONT BACKER ROD &
SEALANT (TYP)
GL
6
3/4" PWD BLOCKING
7
PRE-FINISHED MTL PNL
PRE FINISHED MTL EDGE CAP, RIVET
TO MTL PANEL
PRE FINISHED BRK MTL SOFFIT
FLASHING
WEATHER BARRIER FLASHING
ALUM STOREFRONT WINDOW
CONT BACKER ROD & SEALANT,
EA SIDE (TYP)
GL
4"1/2"
WD SILL BELOW
CONT SEALANT (TYP)
6
7
PRE FINISHED BRK MTL
FLASHING CLOSURE
MTL 'C' GIRT
PRE FINISHED MTL EDGE
CAP W/ WEEP HOLES, RIVET
TO MTL PANEL
PRE FINISHED MTL DRIP
FLASHING W/ HEMMED EDGE
PRE FINISHED BRK MTL
SOFFIT FLASHING
WEATHER BARRIER FLASHING,
LAP INTO OPENING
ALUM STOREFRONT
WINDOW
CONT SEALANT (TYP)
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
PRE-FINISHED MTL PNL
WEATHER BARRIER FLASHING
6
C
1
0
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
WD SILL BELOW
DRYWALL RETURN
WEATHER BARRER
FLASHING
STL COLUMN, RE: STR
2
7
CONT SEALANT (TYP)
MTL SILL BELOW
PRE FINISHED MTL EDGE
CAP, RIVET TO MTL PANEL
PRE FINISHED BRK MTL
SOFFIT FLASHING
ALUM STOREFRONT WINDOW
4"1/2"MTL 'C' GIRT
6
4
6A
MTL 'C' GIRT
PRE FINISHED MTL EDGE
CAP W/ WEEP HOLES, RIVET
TO MTL PANEL
PRE FINISHED MTL DRIP
FLASHING W/ HEMMED EDGE
PRE FINISHED BRK MTL
SOFFIT FLASHING
WEATHER BARRIER FLASHING,
LAP INTO OPENING
STL BEAM, RE: STR
3 1/2"1"
CONT SEALANT (TYP)
CONT BACKER ROD &
SEALANT (TYP)
ALUM STOREFRONT WINDOW
PRE-FINISHED MTL PNL
WEATHER BARRIER
FLASHING
6
5
72 1/2"STL BEAM, RE: STR
1/2"4"
1/2"4"
WEATHER BARRIER
FLASHING
MTL 'C' GIRT
PRE FINISHED MTL EDGE
CAP W/ WEEP HOLES, RIVET
TO MTL PANEL
PRE FINISHED MTL DRIP
FLASHING W/ HEMMED EDGE
PRE FINISHED BRK MTL
SOFFIT FLASHING
ALUM STOREFRONT
WINDOW
CONT SEALANT (TYP)
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
PT WD BLK'G
WEATHER BARRIER FLASHING,
LAP 6" DOWN WALL & OVER 2x
SILL BLKG INTO OPENING
PRE FINISHED MTL SILL
FLASHING W/ CONT GALV CLEAT
PRE-FINISHED MTL PNL
CONT PT WD 2x BLK'G
SLOPE 3/4"WD SILL W/ EASED
EDGES
ALUM STOREFRONT
W/ CONT SUB SILL IN
CONT SEALANT BED
6
WEATHER BARRIER
FLASHING
3/4" PWD BLOCKING
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:27 AMA731
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
EXTERIOR
WINDOW DETAILS
PROJECT STATUS: 100% CD
KH, PH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A731
WINDOW SILL DETAIL @ WALL TYPE 51
0'3"6"0'3"6"
A731
WINDOW SILL DETAIL @ WALL TYPE 72
0'3"6"0'3"6"
A731
WINDOW JAMB DETAIL @ WALL TYPE 75
0'3"6"0'3"6"
A731
WINDOW HEAD DETAIL @ WALL TYPE 77
0'3"6"0'3"6"
A731
WINDOW JAMB DETAIL @ WALL TYPE 7 & COLUMN TRANSITION4
0'3"6"0'3"6"
A731
WINDOW HEAD DETAIL @ WALL TYPE 6A6
0'3"6"0'3"6"
A731
WINDOW HEAD / SILL TRANSITION DETAIL @ WALL TYPE 7 AND BEAM3
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
G.9
6
PRE-FINISHED MTL PNL
PRE-FINISHED MTL
CORNER
1/8" X 3/16" POP
RIVET 1'-0" O.C.
MTL 'C' GIRT
ALUM STOREFRONT
WINDOW
METAL SILL BELOW
1"3 1/2"4"1/2"6
6
STL COLUMN, RE: STR
1/2" PWD BLK'G
PRE FINISHED BRK MTL
SOFFIT FLASHING
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
WEATHER BARRIER FLASHING
J-TRIM GYP EDGE
CONT SEALANT (TYP)
WD SILL W/
EASED EDGES
CONT BACKER ROD &
SEALANT. EA SIDE (TYP)
6
WEATHER BARRIER
FLASHING
MTL 'C' GIRT
ALUM STOREFRONT
WINDOW
METAL SILL BELOW
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
PWD BLK'G6
6
14
STL COLUMN, RE: STR
PRE-FINISHED MTL
FLASHING
WD SILL BELOW
PRE-FINISHED MTL PNL
6
J
0
4 1/2"4 1/2"3/4"
ALUM STOREFRONT
90° CORNER
ALUM STOREFRONT
WINDOW
G.9
2
DRYWALL RETURN
ALUM STOREFRONT
WINDOW
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
WRAP WEATHER BARRIER INTO
OPENING
J-TRIM GYP EDGE
5
CONT SEALANT (TYP)
CONT SEALANT FROM MASONRY
TO STOREFRONT
6
J
ALUM STOREFRONT
WINDOW
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
1/2" PWD BLK'G
STL COLUMN, RE: STR
WEATHER BARRIER FLASHING
1" RIGID INSULATION @
COLUMNS (TYP)
BREAK MTL, FINISH TO
MATCH STOREFRONT
WD SILL BELOW
J
2
1/2" PWD BLK'G
STL COLUMN, RE: STR
WEATHER BARRIER FLASHING
1" RIGID INSULATION @
COLUMNS (TYP)
ALUM STOREFRONT WINDOW
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
BREAK MTL, FINISH TO
MATCH STOREFRONT4"1/2"4"1/2"
WD SILL BELOW
MTL SILL BELOW
J
4"1/2"
STL COLUMN, RE: STR
5
MTL 'C' GIRT
RETURN BLOCK @ JAMB
ALUM STOREFRONT
WINDOW
WEATHER BARRIER
FLASHING
WD SILL BELOW
MTL SILL BELOW
CONT BACKER ROD &
SEALANT (TYP)
WEATHER BARRIER
FLASHING
6
2
SLOPE
ALUM STOREFRONT
W/ CONT SUB SILL IN
CONT SEALANT BED
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:29 AMA732
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
EXTERIOR
WINDOW DETAILS
PROJECT STATUS: 100% CD
PH, SH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A732
WINDOW JAMB CORNER DETAIL @ WALL TYPE 6 & COLUMN2
0'3"6"0'3"6"
A732
WINDOW JAMB DETAIL @ WALL TYPE 6 & 143
0'3"6"0'3"6"
A732
WINDOW CORNER DETAIL @ MAIN ENTRANCE6
0'3"6"0'3"6"
A732
WINDOW JAMB DETAIL @ WALL TYPE 5 AND COLUMN8
0'3"6"0'3"6"
A732
WINDOW JAMB DETAIL @ BREAK MTL COLUMN WRAP4
0'3"6"0'3"6"
A732
WINDOW JAMB CORNER DETAIL @ BREAK MTL COLUMN WRAP7
0'3"6"0'3"6"
A732
WINDOW JAMB DETAIL @ WALL TYPE 51
0'3"6"0'3"6"
A732
WINDOW SILL DETAIL @ SLAB5
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018
1 0
M
2
4
2
4
125' - 1 1/4"
WINDOW HEAD
128' - 1"
LOUVER HEAD
ALUM LOUVER, RE: MECH
ALUM BRK MTL FLASHING TO MATCH STOREFRONT
WEATHER BARRIER FLASHING ON 1/2" PWD BLK'G
6" x 2" MTL STUD HEADER, FILL W/ INSULATION, RE: STR
ALUM STOREFRONT WINDOW
MANUAL ROLLER SHADE
SAG CLG, RE: RCP
CONT SEALANT (TYP)
CONT BACKER ROD & SEALANT, EA SIDE (TYP)
WD 2x BLK'G W/ CONT GWB WRAP @ ROLLER SHADE LOCATIONS
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
PRE FINISHED MTL DRIP FLASHING
W/ HEMMED EDGE
PRE FINISHED BRK MTL SOFFIT
FLASHING, FASTEN BEHIND LOUVER
FLANGE
MTL 'C' GIRT
WEATHER BARRIER FLASHING, LAP
INTO OPENING
PT WD 2x BLK'G
4"1/2"
7
WEATHER BARRIER, LAP OVER
WEATHER BARRIER BELOW &
THROUGH OPENING BEHIND LOUVER
2
4
1/2" PWD SHEATHING & RIGID INSULATION
@ LOUVER LOCATIONS W/ OUT DUCT
PT WD 2x BLK'G @ PWD LOCATIONS
VAPOR BARRIER
PRE-FINISHED MTL PNL
6
6
WEATHER BARRIER FLASHING
1 0
M
2
4
2
4
125' - 1 1/4"
WINDOW HEAD
128' - 1"
LOUVER HEAD
ALUM LOUVER, RE: MECH
ALUM BRK MTL FLASHING TO MATCH STOREFRONT
WEATHER BARRIER FLASHING ON 1/2" PWD BLK'G
ALUM STOREFRONT WINDOW
MANUAL ROLLER SHADE
SAG CLG, RE: RCP
CONT SEALANT (TYP)
CONT BACKER ROD & SEALANT, EA SIDE (TYP)
WD 2x BLK'G W/ CONT GWB WRAP @ ROLLER SHADE LOCATIONS
PRE FINISHED MTL EDGE CAP W/
WEEP HOLES, RIVET TO MTL PANEL
PRE FINISHED MTL DRIP FLASHING
W/ HEMMED EDGE
LAP WEATHER BARRIER OVER MTL
FLASHING FLANGE
PRE FINISHED BRK MTL SOFFIT
FLASHING, FASTEN BEHIND LOUVER
FLANGE
MTL 'C' GIRT
WEATHER BARRIER FLASHING, LAP
INTO OPENING
PT WD 2x BLK'G
4"1/2"
7
6" x 2" MTL STUD HEADER, FILL W/ INSULATION, RE: STR
PRE-FINISHED MTL PNL
6
WEATHER BARRIER FLASHING
0
PRE-FINISHED MTL PNL
ALUM STOREFRONT WINDOW
CONT BACKER ROD &
SEALANT, EA SIDE (TYP)
PRE FINISHED MTL
EDGE CAP
PRE FINISHED BRK MTL
FLASHING CLOSURE
WEATHER BARRIER FLASHING
MTL 'C' GIRT
CONT SEALANT (TYP)
1
6
MTL SILL BELOW
WD SILL BELOW
CONT SEALANT (TYP)
6
6
PRE FINISHED MTL EDGE CAP
PRE FINISHED BRK MTL SOFFIT FLASHING
ALUM STOREFRONT WINDOW
CONT BACKER ROD & SEALANT, EA
SIDE (TYP)
WD SILL BELOW
SEALANT
GYP RETURN
MTL SILL BELOW
MTL 'C' GIRT
PRE-FINISHED MTL PNL
6
WEATHER BARRIER FLASHING
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:31 AMA733
05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
EXTERIOR
WINDOW DETAILS
PROJECT STATUS: 100% CD
PH DG
ASPEN
AMBULANCE
DISTRICT FACILITY
0'3"6"0'3"6"
A733
WINDOW HEAD DETAIL @ MECH LOUVER (W/ OUT DUCT)2
0'3"6"0'3"6"
A733
WINDOW HEAD DETAIL @ MECH LOUVER (W/ DUCT)3
0'3"6"0'3"6"
A733
WINDOW JAMB SEPARATION DETAIL @ WALL TYPE 61
0'3"6"0'3"6"
A733
WINDOW JAMB DETAIL @ WALL TYPE 64
NO: ISSUED FOR: DATE:
6 PR#010 9/25/2018