HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (28).ACBK
ARCHITECT: Chamberlin Architects, P.C.
BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#016.1740.doc
PROPOSAL
REQUEST
FIELD
OWNER
ARCHITECT
CONTRACTOR
PROJECT: Aspen Ambulance District Facility
OWNER: Pitkin County
123 Emma Road, Suite #106
Basalt, CO 81621
TO: FCI Constructors, Inc.
3070 I-70 Business Loop Building A
Grand Junction, CO 81504
PROPOSAL REQUEST NO: Sixteen (16)
DATE: November 20, 2018
ARCHITECT'S PROJECT NO: 1740
CONTRACT DATED: May 9, 2018
Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications
to the Contract Documents described herein.
THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED
HEREIN.
Drawings
1. Sheet A612, Detail 7: Modify Stair 302 Tread & Riser detail as illustrated in the attached Sketch ASK-6:
a. Add stair nosing (AS 9711 by Masco Masons Supply or approved equal) at treads and landing.
b. Add non-slip coating at treads and landing.
i. Epoxy coating: 1st Coat: ArmorSeal® Floor-Plex 8100, B70-8100 Series
(2.0 - 4.0 mils dry per coat)
2nd Coat: ArmorSeal® Floor-Plex 8100, B70-8100 Series
(2.0 - 4.0 mils dry per coat)
ii. Slip-resistant additive: H&C SharkGrip Slip Resistant Additive (into 2nd Coat)
Attachments: ASK-6
STL STRINGER, RE: STR (PNT P6)STL RISER (PNT P6)4" WIDE ABRASIVE NOSING (AS 9711 BY MASCO MASONS SUPPLY or APPROVED EQ) @ TREADS & LANDING (TYP)NON-SLIP COATING @ TREADS & LANDING (TYP)4"11PREPARED BY:PROJECT:PROJECT NO:SCALE:DESCRIPTION:DATE:ISSUED WITH:LOCATION:GRAND JUNCTION, COLORADO970.242.6804RAPID CITY, SOUTH DAKOTA605.355.680411/20/18PR#016 3" = 1'-0"1740JWSTAIR 302 TREAD & RISER DETAIL -REVISEDASK-67/A612AADF