Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (29).ACBK ARCHITECT: Chamberlin Architects, P.C. BY: Jonathan West S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#017.1740.doc PROPOSAL REQUEST FIELD OWNER ARCHITECT CONTRACTOR PROJECT: Aspen Ambulance District Facility OWNER: Pitkin County 123 Emma Road, Suite #106 Basalt, CO 81621 TO: FCI Constructors, Inc. 3070 I-70 Business Loop Building A Grand Junction, CO 81504 PROPOSAL REQUEST NO: Seventeen (17) DATE: January 11, 2019 ARCHITECT'S PROJECT NO: 1740 CONTRACT DATED: May 9, 2018 Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications to the Contract Documents described herein. THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED HEREIN. Project Manual – Volume II Specification section 22400, Part 2, add the following: 2.11 WC-3 TANK TYPE WATER CLOSETS A. Bowl: ASME A112.19.2M; ADA accessible, floor mounted, siphon jet, vitreous china, 16.5 inches high close-coupled closet combination with elongated rim, insulated vitreous china closet tank with fittings, lever operated 4 inch piston flush valve, trip lever on right hand side, bolt caps, white; American Standard model 211AA.105 or equivalent. B. Seat: Solid white plastic, open front, extended back, slow closing, without cover. Drawings Sheet P102 Upper Level Plumbing Plan: In Shower 225, change toilet designation from WC-2 to WC-3. Attachments: none