HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (31).ACBK ARCHITECT: Chamberlin Architects, P.C. BY: Casey Sievila S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#019.1740.doc PROPOSAL REQUEST FIELD OWNER ARCHITECT CONTRACTOR PROJECT: Aspen Ambulance District Facility OWNER: Pitkin County 123 Emma Road, Suite #106 Basalt, CO 81621 TO: FCI Constructors, Inc. 3070 I-70 Business Loop Building A Grand Junction, CO 81504 PROPOSAL REQUEST NO: Nineteen (19) DATE: February 8, 2019 ARCHITECT'S PROJECT NO: 1740 CONTRACT DATED: May 9, 2018 Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications to the Contract Documents described herein. THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED HEREIN. Drawings Add corner guards per attached reissued sheets A161 & A162. Specifications See attached specification for Wall and Door Protection 102600. Attachments: Reissued sheets A161 & A162. Specification Section 102600 Wall and Door Protection. WALL FINISHESP# - CMU OR GYPSUM WALLBOARD W/ PAINT.MW - CLEAR MARKER WALL PAINT OVER GWB PAINTED P1 WITH A LEVEL 5 GWB FINISH. RE: VISUAL DISPLAY SPECIFICATION SECTION.FRP - FIBERGLASS REINFORCED PANEL.T# - TILE.WD - WOOD FEATURE WALL.CEILNG FINISHAPC - SUSPENDED ACOUSTICAL PANEL CEILING GRID AND TILE.P# - GYPSUM WALLBOARD WITH PAINT. OTS - OPEN TO STRUCTURE. PAINT COLOR AS NOTED.FLOOR FINISHESCPT# - CARPETT# - FLOOR TILE.PCONC - POLISHED CONCRETE.CONC - SEALED CONCRETE.RUB - RUBBER ATHLETIC FLOORING.EM - RECESSED ENTRY MAT, RE: SPECS.WD - WOOD STAIR TREADS, RE: SPECS.BASE FINISHEST# - TILE BASE.RUB - RUBBER BASE. WD - WOOD W/ TRANSPARENT FINISH, RE: 5/A611.FINISH NOTES1. PROVIDE EPOXY PAINT ON WALLS AND CEILINGS IN WET AREAS. AMBULANCE BAYS, BATHROOMS, SHOWERS, KITCHEN BACKSPLASH WALL, JANITOR AND DECON.2. PROVIDE FRP AS SHOWN ON ELEVATIONS. PROVIDE TOP AND BOTTOM EDGE TRIM AND DIVISION TRIM, RE: SPECS.3. IMPACT RESISTANCE GWB TO 4'.4. USE 13X20 INCH SIZE TILE IN THE ELEVATOR.5. PROVIDE PWD FOR MOUNTING EQUIPMENT BEHIND DRYWALL ON ALL WALLS (TYP) UP TO 12 FEET.6. SEAL AT JOINT BETWEEN CMU AND CONCRETE FLOOR.CPT1WD1,2P1DHP1P1SATFLOOR FINISHBASE FINISHFINISH NOTESCEILING FINISHWALL FINISH (NORTH, SOUTH, EAST, WEST)NOTE: COLORS, RE: INTERIOR COLOR SCHEDULE A741PATTERN AT WALLS, RE: INTERIOR ELEVATIONS A401-A406PATTERN AT CEILINGS, RE: REFLECTED CEILING PLAN A121-A122FLOOR FINISH TRANSITIONS, RE: A703CORNER GUARDS14ABCDEG.9IJ1245673LOBBY101WOMEN102MEN103TRAININGROOM104ELEC.105APPARATUSBAY #1106APPARATUSBAY #2107APPARATUSBAY #3108APPARATUSBAY #4109APPARATUSBAY #5110APPARATUSBAY #6111DECON112READYROOM113MEDICALSTORAGE114FITNESS115STAIR302ELEVATOR301STAIR303P1P1/FRPP1/FRPP1OTS-P2CONC1, 2, 6P1P1P1P1P2PCONC/WCPTWD-T2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T31T2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T31-P1P1P1OTS-P6WD-------T1-4P1P1P1P1OTS-P2CONCRUB-P1P1P1P1P2/APCCPT1RUB-P1P1P1P1OTS-P2RUB 1RUB3, 5P1P1P1P1OTS-P2CONCRUB-P1P1P1P1APCCONCRUB-FRPFRPFRPFRPOTSCONCRUB1,2P1P1P1P1OTS - P2RUB 2RUBFCONCRUB 1PCONCCPT1CONCPCONCT1T1TYP. ALL APPARATUS BAYSPCONCRECESSED WALK OFF CARPET, RE: SPECSSTORAGE116P1P1P1P1P2/APCCPT1RUB-CONCRUB 2CONCRUB 1ALIGN0G3' - 0 1/4"3' - 11 3/4"12' - 10 3/4"UP9A703________________________________________1ASK-01________________________________________3.566141414DRAWN BY:CHECKED BY:SHEET NO:PROJECT NO:DATE:CHAMBERLIN ARCHITECTS437 Main St.Grand Junction, Colorado 81501T 970.242.6804725 Saint Joseph St., Suite B1Rapid City, South Dakota 57701T 605.355.6804www.chamberlinarchitects.comE N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G NC 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt2/8/2019 3:11:13 PMA161JANUARY 22,20181740CASTLE CREEK ROADASPEN, COLORADOGROUND INTERIORFINISH PLANPROJECT STATUS: 100% CDSHJWASPENAMBULANCEDISTRICT FACILITY0'4'8'0'4'8'A161GROUND LEVEL FINISH PLAN1NO: ISSUED FOR: DATE:6 PR#010 9/25/1814 PR#019 2/8/19 ..ABCDEG.9IJ1245673KITCHEN218DAYROOM216IT211TOILET208MECH/ELEC209CORRIDOR210LIBRARY /REPORTS215CONFERENCE214OFFICE212STOR.213WAITING201OFFICE203OFFICE204OFFICE205FLEX206DINING217PANTRY219UNIFORMLOCKERS221SHOWER227STORAGE228BUNK RM229BUNK RM230BUNK RM231BUNK RM232CORRIDOR224CORRIDOR220MECH223LAUNDRY222SHOWER226P4P1P1P1APCCPT1RUB-P4P1P1P1APCCPT1RUB-P4P1P1P1APCCPT1RUB-P5P1P1MWAPCCPT1RUB-P1P1P1P1OTS-P6PCONCWD-P1P1WDP1OTS-P6PCONCWD-P1P1P1P1OTS - NO PNTCONCRUB-WDP1P1P1OTS - P6PCONCWD-P1P1P1P1APCCPT1RUB-P1P1MWMWAPCCPT1RUB-P1P5MWP1APCCPT1RUB-P1P1P1P1APCCPT 1RUB-P1P1P1P1APCCONCRUB1P1P1P1P1OTS-P2CONCRUB-P1P1P1P1APCCPT1RUB-P1P1P1P1APCPCONCRUB-P1P1P1P3APCCPT2RUB-P1P1P1P3APCCPT2RUB-P1P1P1P3APCCPT2RUB-P1P1P1P3APCCPT2RUB-T2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T11T2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T11T2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T31P1P1P1P1APCCPT2RUB-P1P1P1P1APCCPT2RUB-FPCONCCPT1PCONCCPT1PCONCCPT1CONCCPT2CONCRUB2PCONCCPT 2T1CPT 2T1CPT 2T1CPT1PCONCCPT1CPT1CPT1PCONCCONCT14' - 0"ALIGNCPT 1 OVER PCONCALIGNT2-4/P1T2-4/P1T2-4/P1T2-4/P1P2T1T31P1P1P1P1OTS - NO PNTCONCRUBCPT1CPT2STAIR303P1P1P1P1OTS - P2RUB 2RUBSTAIR302-P1P1P1OTS-P6WD--P1P1WDP1OTS-P6PCONCWD10GDNCONCPCONCPCONCWD3A703________________________________________(WITHOUT DOOR)OPENTO BELOW3.5771414141414WALL FINISHESP# - CMU OR GYPSUM WALLBOARD W/ PAINT.MW - CLEAR MARKER WALL PAINT OVER GWB PAINTED P1 WITH A LEVEL 5 GWB FINISH. RE: VISUAL DISPLAY SPECIFICATION SECTION.FRP - FIBERGLASS REINFORCED PANEL.T# - TILE.WD - WOOD FEATURE WALL.CEILNG FINISHAPC - SUSPENDED ACOUSTICAL PANEL CEILING GRID AND TILE.P# - GYPSUM WALLBOARD WITH PAINT. OTS - OPEN TO STRUCTURE. PAINT COLOR AS NOTED.FLOOR FINISHESCPT# - CARPETT# - FLOOR TILE.PCONC - POLISHED CONCRETE.CONC - SEALED CONCRETE.RUB - RUBBER ATHLETIC FLOORING.EM - RECESSED ENTRY MAT, RE: SPECS.WD - WOOD STAIR TREADS, RE: SPECS.BASE FINISHEST# - TILE BASE.RUB - RUBBER BASE. WD - WOOD W/ TRANSPARENT FINISH, RE: 5/A611.FINISH NOTES1. PROVIDE EPOXY PAINT ON WALLS AND CEILINGS IN WET AREAS. AMBULANCE BAYS, BATHROOMS, SHOWERS, KITCHEN BACKSPLASH WALL, JANITOR AND DECON.2. PROVIDE FRP AS SHOWN ON ELEVATIONS. PROVIDE TOP AND BOTTOM EDGE TRIM AND DIVISION TRIM, RE: SPECS.3. IMPACT RESISTANCE GWB TO 4'.4. USE 13X20 INCH SIZE TILE IN THE ELEVATOR.5. PROVIDE PWD FOR MOUNTING EQUIPMENT BEHIND DRYWALL ON ALL WALLS (TYP) UP TO 12 FEET.6. SEAL AT JOINT BETWEEN CMU AND CONCRETE FLOOR.CPT1WD1,2P1DHP1P1SATFLOOR FINISHBASE FINISHFINISH NOTESCEILING FINISHWALL FINISH (NORTH, SOUTH, EAST, WEST)NOTE: COLORS, RE: INTERIOR COLOR SCHEDULE A741PATTERN AT WALLS, RE: INTERIOR ELEVATIONS A401-A406PATTERN AT CEILINGS, RE: REFLECTED CEILING PLAN A121-A122FLOOR FINISH TRANSITIONS, RE: A703CORNER GUARDS14DRAWN BY:CHECKED BY:SHEET NO:PROJECT NO:DATE:CHAMBERLIN ARCHITECTS437 Main St.Grand Junction, Colorado 81501T 970.242.6804725 Saint Joseph St., Suite B1Rapid City, South Dakota 57701T 605.355.6804www.chamberlinarchitects.comE N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G NC 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt2/8/2019 3:14:30 PMA162JANUARY 22,20181740CASTLE CREEK ROADASPEN, COLORADOUPPER INTERIORFINISH PLANPROJECT STATUS: 100% CDSHCSASPENAMBULANCEDISTRICT FACILITY0'4'8'0'4'8'A162UPPER LEVEL FINISH PLAN1NO: ISSUED FOR: DATE:7 ASI#002 10/3/201814 PR#019 2/8/19 1740 – ASPEN AMBULANCE DISTRICT FACILITY Chamberlin Architects WALL AND DOOR PROTECTION 102600 - 1 SECTION 10 2600 - WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Corner guards. 1.2 ACTION SUBMITTALS A. Product Data: For each type of product. B. Shop Drawings: For each type of wall and door protection showing locations and extent. 1. Include plans, elevations, sections, and attachment details. C. Samples: For each exposed product and for each color and texture specified, 12 inches (300 mm) long. 1.3 INFORMATIONAL SUBMITTALS A. Sample warranty. 1.4 CLOSEOUT SUBMITTALS A. Maintenance data. 1.5 WARRANTY A. Special Warranty: Manufacturer agrees to repair or replace components of wall- and door- protection units that fail in materials or workmanship within specified warranty period. 1. Warranty Period: Five years from date of Substantial Completion. 1.6 EXTRA MATERIALS A. Furnish extra materials described below, before installation begins, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Corner Guards: Full-size units equal to 5 percent of amount installed for each type indicated, but not less than 2 units. 1740 – ASPEN AMBULANCE DISTRICT FACILITY Chamberlin Architects WALL AND DOOR PROTECTION 102600 - 2 PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Surface Burning Characteristics: Comply with ASTM E 84 or UL 723; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Flame-Spread Index: 25 or less. 2. Smoke-Developed Index: 450 or less. B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines for Buildings and Facilities and ICC A117.1. 2.2 CORNER GUARDS A. Surface-Mounted, Plastic-Cover Corner Guards - CG: Manufacturer's standard assembly consisting of snap-on, resilient plastic cover installed over retainer; including mounting hardware; fabricated with 90-degree turn to match wall condition. 1. Basis-of-Design Product: Subject to compliance with requirements, provide Construction Specialties, Inc.; SSM-20N or comparable product by one of the following: a. IPC Door and Wall Protection Systems; Division of InPro Corporation b. Korogard Wall Protection Systems; a Division of RJF International Corporation. 2. Cover: Extruded rigid plastic, minimum 0.078-inch (2.0-mm) wall thickness; as follows: a. Profile: Nominal 2 inch (50mm) long leg and ¼ inch (6mm) corner radius. b. Height: Manufacturer’s standard full height starting above base and ending at the ceiling. c. Color and Texture: As selected from manufacturer’s standard colors. 3. Continuous Retainer: Minimum 0.060-inch- (1.5-mm-) thick, one-piece, extruded aluminum. 4. Top and Bottom Caps: Prefabricated, injection-molded plastic; color matching cover; field adjustable for close alignment with snap-on cover. 2.3 MATERIALS A. Plastic Materials: Chemical- and stain-resistant, high-impact-resistant plastic with integral color throughout; extruded and sheet material as required, thickness as indicated. B. Polycarbonate Plastic Sheet: ASTM D 6098, S-PC01, Class 1 or Class 2, abrasion resistant; with a minimum impact-resistance rating of 15 ft.-lbf/in. (800 J/m) of notch when tested according to ASTM D 256, Test Method A. 1740 – ASPEN AMBULANCE DISTRICT FACILITY Chamberlin Architects WALL AND DOOR PROTECTION 102600 - 3 C. Fasteners: Aluminum, nonmagnetic stainless-steel, or other noncorrosive metal screws, bolts, and other fasteners compatible with items being fastened. Use security-type fasteners where exposed to view. D. Adhesive: As recommended by protection product manufacturer. 1. Adhesives shall have a VOC content of 70 g/L or less. 2. Adhesive shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." PART 3 - EXECUTION 3.1 INSTALLATION A. Installation Quality: Install wall and door protection according to manufacturer's written instructions, level, plumb, and true to line without distortions. Do not use materials with chips, cracks, voids, stains, or other defects that might be visible in the finished Work. B. Mounting Heights: Install wall and door protection in locations and at mounting heights indicated on Drawings. C. Accessories: Provide splices, mounting hardware, anchors, trim, joint moldings, and other accessories required for a complete installation. 1. Provide anchoring devices and suitable locations to withstand imposed loads. 2. Where splices occur in horizontal runs of more than 20 feet (6.1 m), splice aluminum retainers and plastic covers at different locations along the run, but no closer than 12 inches (305 mm) apart. 3. Adjust end and top caps as required to ensure tight seams. END OF SECTION 10 2600