ARCHITECT: Chamberlin Architects, P.C.
BY: Casey Sievila S:\1740 - Pitkin County Ambulance Facility\6. CONSTRUCTION\PROPOSAL REQUESTS\PR#020.1740.doc
PROPOSAL
REQUEST
FIELD
OWNER
ARCHITECT
CONTRACTOR
PROJECT: Aspen Ambulance District Facility
OWNER: Pitkin County
123 Emma Road, Suite #106
Basalt, CO 81621
TO: FCI Constructors, Inc.
3070 I-70 Business Loop Building A
Grand Junction, CO 81504
PROPOSAL REQUEST NO: Twenty (20)
DATE: March 5, 2019
ARCHITECT'S PROJECT NO: 1740
CONTRACT DATED: May 9, 2018
Please submit an itemized quotation for changes in the Contract Sum and/or Time incident to proposed modifications
to the Contract Documents described herein.
THIS IS NOT A CHANGE ORDER NOR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED
HEREIN.
Drawings
Sheet M101:
1. Shift IR-1 combustion air and combustion vent east to grid line E as illustrated in the attached Sheet M101.
2. Shift IR-3 combustion air and combustion vent east to grid line C as illustrated in the attached Sheet M101.
Sheet M102:
1. Shift the outdoor air intake plenum to the east, add a duct sleeve enclosure at the structural column, and
increase the width of the plenum to compensate for obstruction by column as illustrated in the attached
Sheet M102.
Attachments: M101; M102
A B C D E H I J
LOBBY
101
WOMEN
102
MEN
103
TRAINING
ROOM
104
ELEC.
105
APPARATUS
BAY #1
106
APPARATUS
BAY #2
107APPARATUS
BAY #3
108
APPARATUS
BAY #4
109
APPARATUS
BAY #5
110
APPARATUS
BAY #6
111
DECON
112
READY
ROOM
113
MEDICAL
STORAGE
114
FITNESS
115
STAIR
302
ELEVATOR
301
STAIR
303
STORAGE
116
F G
GROUND LEVEL MECHANICAL PLAN
IR-1IR-2
IR-3
CH-1
UNDER STAIRS
SS-1
8'-0" AFF
COMBUSTION AIR AND EXHAUST
THROUGH WALL >10' HORIZONTALLY
FROM AIR INTAKE ABOVE WITH
CENTERLINE AT 13'-6" AFF (TYP OF 3)
CU-3
SA-2
12"x12"
430 CFM
20"x20" SA AND
RA THROUGH
FLOOR ABOVE
14"Ø RA UP THROUGH
FLOOR ABOVE
SA-1
14"Ø
735 CFM
SA-3
9"x9"
240 CFM
SA-3
9"x9"
230 CFM
SA-1
6"Ø
75 CFM
SA-5
6"Ø
50 CFM
SA-5
6"Ø
30 CFM
EA-1
6"x6"
70 CFM
EA-1
6"x6"
70 CFM
EA-1
6"x6"
40 CFM
0'8'
4'OARAEAFACU-2 CU-1
RA-2
18"x18"
RA-1
24"x24"
RA-3
10x10"
RA-3
10x10"
RA-1
12"x24"
SA-5
6"Ø
100 CFM
T
M
T
12"Ø
AT 12'-0" AFF
AT 12'-0" AFF
12"Ø SPIRAL10"Ø SPIRAL6"Ø SPIRAL
20"x20"
12"Ø
6"Ø SPIRAL
10"Ø SPIRAL
M
6"Ø SPIRAL
8"Ø SPIRAL
ERV-2
20"x20"
HC-2
12"Ø
14"x12"
EA-2
24"x12"
320 CFM
12"Ø EA AND OA
THROUGH FLOOR
ABOVE
6"Ø
6"Ø
T
SWSSWRSWSSWRSWSSWR
SWSSWR2"
PIPING THROUGH
FLOOR ABOVE
15'-10"
3'
3'
3'-11"
EF-1
13'-4" AFF
22"x22"
EA-1
36"x20"
SA-2
22"x26"
2700 CFM OA
17"x22" RADIUSED ELBOW
TO 17"x22" THROUGH
FLOOR ABOVE
28"x15" OA
EF-2
13'-4" AFF6"Ø EA
BDD
22"x26" BDD
VENT HOOD (TYP OF 3)
INTAKE HOOD (TYP OF 3)
ALL REFRIGERANT PIPING ON GALVANIZED
STRUT ANCHORED TO HOUSEKEEPING PADS
AND COVERED WITH 18 GAUGE GALVANIZED
HAT CHANNEL PROTECTIVE LID
30 CFM
SA-1
14"Ø
735 CFM
RA-1
24"x12"
6"Ø
T
TT
RADIANT TUBE
CENTERLINE AT 12'-4" AFF RADIANT TUBE
CENTERLINE AT 12'-4" AFF
RADIANT TUBE
CENTERLINE AT 12'-4" AFF
12"Ø
4"Ø
UNDERCUT
8"Ø, Voa=185CFM
4"Ø, Voa=
35CFM
10"Ø, Voa=320CFM
14"x26" OA FROM
ABOVE TO 22"x26"
13'-4" AFF FACING DOWN
DIRECTING AIR EAST
PIPING THROUGH
STRUCTURE
REFRIGERANT PIPING
UP IN WALL TO NEAR
STRUCTURE ABOVE
REFRIGERANT PIPING
THROUGH FLOOR ABOVE
M
1/2" HWS AND
HWR ON WALL
BOLT CONDENSING UNIT
TO HOUSEKEEPING PAD
IN FOUR PLACES (TYP)
12" LONG 4" FLEX DUCT
24" LONG TYPE B
4" FLEX VENT
12" LONG 4" FLEX DUCT
24" LONG TYPE B
4" FLEX VENT
12" LONG 4" FLEX DUCT
24" LONG TYPE B
4" FLEX VENT
FLOOR
1
233
4
HOUSEKEEPING PAD (TYP)
12"Ø
3/4" HWS AND HWR
FROM ABOVE
PROVIDE RESTRAINTS
ATTACHED TO WALL AND
ANCHOR SS-1 TO SHELF.
CARBON MONOXIDE DETECTOR
FOR EF-1 CONTROL AND
ALARM, ℄ AT 5'-0" AFF
AT 12'-0" AFF
AT 12'-0" AFF
1/2" HWS AND
HWR FROM ABOVE
10"Ø
SUPPORT ON TRAPEZE
WITH < 12" LONG RODS AND
SWIVELS AT ENDS OF RODS
12"Ø BYPASS
AND DAMPER
M
4
4
KEYED NOTES
1.INSTALL TOP OF UNIT AT 2" BELOW JOISTS. HANG FROM JOISTS WITH RODS
AND B-LINE CHSCS SERIES ISOLATORS AT FOUR CORNERS. INSTALL STRUT
BRACING TO STRUCTURE IN NORTH-SOUTH AND EAST-WEST DIRECTIONS WITH
B-LINE SERIES CNNK PADS AT BRACE CONNECTION POINTS .
2.REFER TO IR-1 INFRARED HEATER SUPPORT DETAIL ON SHEET M301.
3.REFER TO IR-2 AND IR-3 INFRARED HEATER SUPPORT DETAIL ON SHEET M301.
4.SUPPORT ON TWO STRUT SPANNING ACROSS AND ANCHORED TO TWO
JOISTS. INSTALL B-LINE SERIES RM-D NEOPRENE MOUNTS ANCHORED TO FAN
AND STRUT.
NOTED OTHERWISE.
GENERAL NOTES APPLICABLE TO ALL MECHANICAL PLANS
THE MECHANICAL CONTENT OF THIS DRAWING IS DIAGRAMMATIC AND NOT
NECESSARILY TO SCALE.
THE CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO LOCATIONS OF
DUCTWORK, EQUIPMENT, PIPING, AND SUPPORTS IN ORDER TO COORDINATE
WITH BUILDING CONSTRUCTION AND WORK OF OTHER TRADES.
ALL BRANCH DUCTS SERVING ONE DIFFUSER OR EXHAUST GRILLE SHALL
INCLUDE A VOLUME DAMPER AT THE BRANCH DUCT POINT OF ORIGIN,
UNLESS THE GRILLE OR DIFFUSER HAS BEEN SPECIFIED TO INCLUDE A
BALANCING DAMPER.
BRANCH DUCTS SERVING SINGLE DIFFUSERS SHALL BE SIZED TO MATCH THE
DIFFUSER NECK SIZE UNLESS OTHERWISE INDICATED.
ALL FLOOR PENETRATIONS SHALL BE FINISHED WITH FIRE STOP MATERIALS
IN ACCORDANCE WITH THE SPECIFICATIONS.
INDICATED DUCT DIMENSIONS ARE SHEET METAL DIMENSIONS.
ROUND DUCTS ARE INDICATED USING SINGLE LINE.
REFER TO SCHEDULES AND SPECIFICATIONS FOR EQUIPMENT AND
MATERIALS OF CONSTRUCTION.
AIR VOLUME INDICATED FOR SA DIFFUSERS AND SA GRILLES INCLUDES AIR
FROM FURNACE AND VENTILATION AIR FROM ERV.
INDICATED MOUNTING HEIGHTS ARE TO BOTTOM OF EQUIPMENT UNLESS
NOTED OTHERWISE.
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTS05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
PROJECT STATUS: 100% CD
DCR DCR
ASPEN
AMBULANCE
DISTRICT FACILITY
NO:ISSUED FOR:DATE:
356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584
PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net
RALSTON MECHANICAL CONSULTING, LLC
Engineering for HVAC, Refrigeration, and Plumbing
M101
GROUND LEVEL
MECHANICAL PLAN
PR#020 02/27/20194
A B C D E H I J
1
2
4
5
6
7
WAITING
201
OFFICE
203
OFFICE
204
OFFICE
205
FLEX
206
MECH/ELEC
209
CORRIDOR
210
STOR.
213
OFFICE
212
CONFERENCE
214
LIBRARY /
REPORTS
215
CORRIDOR
220
UNIFORM
LOCKERS
221
LAUNDRY
222
CORRIDOR
224
SHOWER
225
SHOWER
226
SHOWER
227
BUNK RM
229
BUNK RM
230
BUNK RM
231
BUNK RM
232
STORAGE
228
3
TOILET
208
IT
211
DINING
217
DAYROOM
216
KITCHEN
218
MECH
223
F
PANTRY
219
STAIR
303
STAIR
302
ELEVATOR
301
0
G
DECK
233
UPPER LEVEL MECHANICAL PLAN
BL-1
LR-1
11'-11"x2'-9 3/4"
SS-1
LR-1
36"x132"
LR-1
36"x30"
4"Ø DRYER VENT
DUCT 36" AFF
14"Ø SPIRAL OA
THROUGH STRUCTURE
SA-2
16"x14"
710 CFM
SA-1
6"Ø
105 CFM
SA-1
8"Ø
135 CFM
SA-1
6"Ø
100 CFM
SA-1
6"Ø
110 CFM
SA-4
12"x6"
150 CFM
SA-4
20"x8"
315 CFM
SA-4
16"x8"
265 CFM
SA-2
24"x12"
910 CFM
SA-2
18"x12"
580 CFM
SA-1
6"Ø
100 CFM
SA-1
8"Ø
120 CFM
SA-1
6"Ø
100 CFM
SA-1
6"Ø
70 CFM
SA-1
6"Ø
80 CFM
14"Ø SPIRAL SA
THROUGH STRUCTURE
12"Ø SPIRAL RA
THROUGH STRUCTURE
12"Ø EA FROM
HOOD
0'8'
4'
PC-1
BL-2 COMBUSTION EXHAUST AND
AIR PIPING AT 7'-2" AFF. INSULATE
INDOOR COMBUSTION AIR PIPING.
BL-2
PC-3
EA-1
6"x6"
70 CFM
EA-1
8"x8"
70 CFM
EA-1
8"x8"
70 CFM
EA-1
8"x8"
70 CFM
OARA
EAFA
SA-2
14"x14"
170 CFM
12" SPIRAL RA
8"Ø, Voa=200CFM
FR-1
FR-2FR-3
DX-1
DX-2DX-3
ERV-1
AT FLOOR
SA-2
32"x24" AT 8" AFF
600 CFM
(2) 5"x14" DUCTS
DOWN IN WALL
BL-1 COMBUSTION EXHAUST AND
AIR PIPING AT 7'-2 AFF. INSULATE
INDOOR COMBUSTION AIR PIPING.
TA-1
6"Ø
TA-1
6"Ø
TA-1
6"Ø
RA-2
24"x18"
RA-1
24"x12"
15"x26"32"x24"
M
M
M
M
M
M
MM
ERV-3
HC-3
RA-1
24"x12"
50 CFM
RA-1
24"x12"
FC-1
M BDD
TA-1
6"Ø
RA-2
6"x6"
16"x16"
9"Ø
16"x15"M M M
12"Ø
M
(3) 3" COMBUSTION AIR AND
(3) 3" COMBUSTION EXHAUST
THROUGH JOISTS TO AND FROM
FURNACES. INSULATE INDOOR
COMBUSTION AIR PIPING.
MINIMIZE NUMBER OF ELBOWS.
PC-4
T T
T
T
T
T
T
T
M
8"Ø10"Ø
6"Ø, 75CFM
SA-1
6"Ø
80 CFM
SA-1
6"Ø
80 CFM
RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
9"Ø
8"Ø
5"Ø5"Ø
5"Ø
6"Ø
6"Ø
6"Ø
8"Ø 9"Ø
12"Ø
6"Ø
6"Ø
6"Ø
6"Ø
6"Ø
8"Ø
RA-2
14"x14"
8"Ø
8"Ø
6"Ø, Voa=100CFM
6"Ø 8"Ø
12"Ø
14"Ø RA
FROM BELOW
10"Ø SPIRAL RA
32"Ø SPIRAL EA
6"Ø SPIRAL FA
16"Ø SPIRAL SA
32"Ø SPIRAL OA
3
14"Ø SPIRAL SA
T
14"Ø SPIRAL OA
16"Ø SPIRAL
8"Ø
6"Ø
6"Ø
2" SWS AND SWR
THROUGH FLOOR
7"Ø
6"Ø
7"Ø
15"x5" ABOVE BEAM
10"Ø
7"Ø
EF-3
SUSPEND FROM JOISTS
SA-5
6"Ø
30 CFM
4"Ø
3"Ø, Voa=15CFM
10"Ø
3"Ø, Voa=25CFM
SA-7
10"x8"
150 CFM
10"Ø
3"Ø, Voa=25CFM
3"Ø, Voa=25CFM
3"Ø, Voa=15CFM
3"Ø, Voa=15CFM
3"Ø, Voa=15CFM
T
HC-1
LR-1
9'-1"x2'-9 3/4"
LR-1
8'-4"x2'-9 3/4"
LR-1
9'-9-1/2"x2'-9 3/4"
17"x22" EA THROUGH FLOOR
BELOW, TRANSITION TO 36"x30"
INTO LOWER 30" OF LOUVER
HWS
HWR
HWS
HWR
HWSHWRHWRHWSHWR
HWS
12"Ø
14"x26"
14"x26" THROUGH
FLOOR BELOW
36"x30" TO 36"x26"
1
2
4
5
6
7
20"x18" RA
20"x18" SA
10'-6" AFF
18"Ø
5"Ø OA
REFRIGERANT PIPING
FROM BELOW TO DX COILS
10
8HWRHWS RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
RA-1
24"x12"
RANGE HOOD
PC-2
COORDINATE LOCATION OF
FURNACES WITH STRUCTURE
ABOVE AND BELOW
11
11
12
ANCHOR TO WALL PER
BL-2 INSTALLATION
INSTRUCTIONS
ATTACH BL-1 TO
HOUSEKEEPING PAD WITH
3/8" CONCRETE ANCHORS
12"Ø
1/2" HWS AND HWR DOWN IN
WALL THROUGH FLOOR
36"x30" TO UPPER 30" OF
LOUVER FOR EF-3 AND ERV-3 EA
10"Ø
3
9
14
13
11
(3) ZONE CONTROLLERS
14"x11"
HWSHWR
COVER NO AIRFLOW AREAS
WITH SHEET METAL
72"x34"x34"
60"x34"x34"
EA-2
12"x24"
120 CFM
20"x20" UP
BETWEEN JOISTS
24"x20" UP TO
BETWEEN JOISTS
1"
1/2"
1"
1"
1"
3/4"
M
M
15
151634"x40" OA DOWN
32"x40" EA UP
32"x24"
10"Ø SLEEVE AROUND COLUMN
SEALED TO WALLS OF PLENUM.
INSULATE SLEEVE WITH 2"
THICK DUCT WRAP.
AIR INTAKE >10FT EAST
OF IR-1 COMBUSTION
EXHAUST BELOW
4
KEYED NOTES
1.12"Ø EA THROUGH FLOOR BELOW.
2.12"Ø OA THROUGH FLOOR BELOW.
3.6"Ø EA FROM TOILET 208 TO ERV-1 RA INLET.
4.20"x18" EA ABOVE 20"x18" OA SERVING FR-1.
5.20"x18" EA ABOVE 20"x18" OA SERVING FR-3.
6.20"x18" OA SERVING FR-2.
7.20"x18" EA SERVING FR-2.
8.12"x9" FRESH AIR FROM ERV-1 THROUGH HC-1 AND UP TO 11'-6" AFF.
9.10"Ø EA FROM ERV-1 TO EA MAIN.
10.3/4" HWS AND HWR DOWN THROUGH FLOOR.
11.HANG FROM JOISTS WITH RODS AT FOUR CORNERS. INCLUDE B-LINE CHSCS
SERIES ISOLATORS AND STRUT BRACING TO STRUCTURE IN NORTH-SOUTH
AND EAST-WEST DIRECTIONS.
12.SUPPORT WITH FOUR B-LINE SERIES RM-D NEOPRENE MOUNTS ANCHORED
TO ERV AND FLOOR.
13.10"Ø RA TO ERV-1.
14.10"Ø OA TO ERV-1.
15.12"Ø BYPASS DAMPER.
16.40"x18" EA ABOVE AND 40"x18" OA BELOW.M102
UPPER LEVEL
MECHANICAL PLAN
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTS05/09/2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
PROJECT STATUS: 100% CD
DCR DCR
ASPEN
AMBULANCE
DISTRICT FACILITY
NO:ISSUED FOR:DATE:
356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584
PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net
RALSTON MECHANICAL CONSULTING, LLC
Engineering for HVAC, Refrigeration, and Plumbing
PR#020 02/27/20194