HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (66).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 031
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 031 Date Created: 9/21/2018
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ConfirmationArchitecturalTrash Enclosure Gate Diagonal Tube
Company Name Contact Name Copies NotesCc:
Chamberlin Architects, Inc. Daniel Gartner 1
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
Question Date Required: 9/28/2018
Per detail 11 on architectural sheet A653, the diagonal steel members for the trash enclosure gate are called out to be
HSS 3-1/2" x 1-1/2" x 1/4". Midwest Steel who is the steel supplier for the project has stated they are not able to acquire
the HSS 3-1/2" x 1-1/2" x 1/4" material. It was confirmed that 2-1/2" x 1-1/2" x 1/4" material that Midwest steel can easily
acquire is an acceptable alternate.
Suggestion
Answer Date Answered:
This RFI is for record only, no response is required.
Prolog Manager Printed on: 9/21/2018 FCI_Integration Page 1
1
Sam Meeks
From:Jonathan West <jwest@chamberlinarchitects.com>
Sent:Friday, September 21, 2018 8:24 AM
To:Sam Meeks
Cc:Daniel Gartner; Brian Young
Subject:RE: Aspen Ambulance -
I don’t see any issues with this Sam.
Thanks,
Jonathan
Jonathan West, AIA, LEED GA
C H A M B E R L I N A R C H I T E C T S
G R A N D J U N C T I O N, C O • R A P I D C I T Y, S D
437 Main Street
Grand Junction, CO 81501
Office (970) 242-6804
Fax (970) 422-7422
www.chamberlinarchitects.com
From: Sam Meeks [mailto:smeeks@fciol.com]
Sent: Monday, September 17, 2018 2:42 PM
To: Jonathan West
Cc: Daniel Gartner; Brian Young
Subject: Aspen Ambulance -
Jonathan,
I had an email come through from our steel supplier noting that they would have to make a change to one of the
members on the gates. Can you please confirm that this is acceptable or unacceptable and I can then send a confirming
RFI for record?
“The diagonal tube at the trash gates was called out as 3 1/2x1 1/2x ¼. My detailer used 2 1/2x1 1/2x1/4 as it is the only
tube we can acquire. Can you confirm this is acceptable?”
Sam Meeks
Engineer
FCI Constructors, Inc.
P.O. Box 1767 (81502)
3070 I-70 B, Bldg. A
Grand Junction, CO 81504
P. (970) 434-9093 F. (970) 434-7583 C. (970) 618-8817
www.fciol.com
228 SFHHSSTORAGE402AABB1122RECYCLINGDUMPSTERCOMPOST187 SFTRASHA6533A6535A65346A653________________________________________401402IRRIGATION CONTROL PANEL6" CONC FILLED STL BOLLARD, TYP OF 435' - 4"22' - 8"6' - 8"16' - 8"3' - 4"12' - 8"A653107' - 4"92 SFFACILITYSTORAGE401AABB11226A653________________________________________7A653________________________________________8A653________________________________________9A653________________________________________9A653________________________________________OPPSLOPE 1-1/2" : 12"STANDING SEAM MTL ROOFDSDSPRE FINISHED MTL GUTTER & DOWNSPOUTSCONT BACKER ROD & SEALANT (TYP)CONT GALV MTL CLEATPRE FINISHED BRK MTL SOFFIT & FASCIAPRE FINISHED STANDING SEAM MTL ROOF ON ROOFING UNDERLAYMENT ON CONT ICE & WATER SHIELD ON 1/2" PT PWD ON 1-1/2" RIGID INSULATION ON MTL ROOF DECK, RE: STRPT WD 2x4 BLK'GCONT GALV MTL CLEAT3/4" PT PWD BLK'GSTL ANGLE, RE: STRPRE FINISHED MTL GUTTER4"4"COMPRESSIBLE INSULATION (TYP)LAP ROOFING UNDERLAYMENT OVER CLEAT FLANGE4"PRE FINISHED MTL PEAK FLASHING W/ CONT GALV CLEATGALV 'Z' CLEAT BY ROOFING MFR'RICE & WATER SHIELD, LAP DOWN FASCIAPRE FINISHED BRK MTL FASCIA FLASHINGPRE FINISHED STANDING SEAM MTL ROOF ON CONT ICE & WATER SHIELD ON 1/2" PT PWD ON 1-1/2" RIGID INSULATION ON MTL ROOF DECK, RE: STRSTL TUBE BEAM, RE: STR (PNT)LAP ROOFING UNDERLAYMENT OVER MTL FASCIA4"PRE FINISHED MTL RAKE FLASHING W/ CONT GALV CLEATCONT GALV MTL 'Z' CLEAT BY ROOFING MFR'RICE & WATER SHIELD, LAP DOWN FASCIAPRE FINISHED BRK MTL FASCIA FLASHINGPRE FINISHED STANDING SEAM MTL ROOF ON CONT ICE & WATER SHIELD ON 1/2" PT PWD ON 1-1/2" RIGID INSULATION ON MTL ROOF DECK, RE: STRLAP ROOFING UNDERLAYMENT OVER MTL FASCIAPT WD 2x4 BLK'GCONT BACKER ROD & SEALANT (TYP)CONT GALV MTL CLEATCOMPRESSIBLE INSULATION (TYP)112211221122111' - 7"T.O. ROOF EDGE109' - 2"B.O. ROOF EDGEA6538A653710' - 0"AABBPRE FINISHED MTL DRIP EDGEGROUND FACE CMU, TYPE 1GROUND FACE CMU, TYPE 2STL TUBE BEAM, RE: STR (PNT)4"x3" WELDED STL TUBE FRAME GATES W/ MTL PANEL (TYPE 2) INFILLS8"x8" STL TUBE COLUMN, RE: STR (PNT)HEAVY DUTY WELD ON STL HINGES (3 PER GATE), CAPABLE OF 700LB GATE LOAD (TYP OF 9)STL CHANNEL JAMB (PNT)LOCKABLE LATCHLOCKABLE BOLTS W/ STL CYLINDER RECEIVER INSET IN CONC SLAB (TYP OF 2)6A653________________________________________3"9' - 6"3"22HEAVY DUTY WELD ON HINGE (PNT)STL HSS 4" x 3" x 1/4" WELDED FRAME (PNT)STL HSS COLUMN, RE: STR (PNT)CONT 1-1/2" x 1-1/2" STL 16ga GALV ANGLE @ MTL PANEL PERIMETER (PNT)PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C.PRE FINISHED HORIZONTAL MTL PANEL (TYPE 2)STL HSS 3-1/2" x 1-1/2" x 1/4" DIAGONAL SET FLUSH TO BACK OF GATE FRAME (PNT)DOUBLE 1-1/2" x 1-1/2" STL 16ga GALV ANGLES @ CTR OF GATE BELOW & ABV HSS DIAGONAL4' - 4 3/8"13' - 10"1' - 1 5/8"@ JAMBS1/2" TYP@ JAMBS1/2" TYPA65311EQEQSTL CHANNEL (C8x11.5) JAMB, RE: STR (PNT)4" x 3" x 1/4" WELDED STL TUBE FRAME GATES W/ MTL PANEL (TYPE 2) INFILLSSTL HSS COLUMN, RE: STR (PNT)DRAWN BY:CHECKED BY:SHEET NO:PROJECT NO:DATE:CHAMBERLIN ARCHITECTS437 Main St.Grand Junction, Colorado 81501T 970.242.6804725 Saint Joseph St., Suite B1Rapid City, South Dakota 57701T 605.355.6804www.chamberlinarchitects.comE N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G NC 2016 CHAMBERLIN ARCHITECTSC:\Revit Projects\1740-PCAF_CENTRAL_csievila.rvt7/12/2018 9:38:44 AMA65305/09/20181740CASTLE CREEK ROADASPEN, COLORADODUMPSTERENCLOSUREPROJECT STATUS: 100% CDPHPHASPENAMBULANCEDISTRICT FACILITY0'4'8'0'4'8'A653DUMPSTER ENCLOSURE FLOOR PLAN10'4'8'0'4'8'A653DUMPSTER ENCLOSURE - ROOF PLAN20'3"6"0'3"6"A653DUMPSTER ENCLOSURE GUTTER DETAIL70'3"6"0'3"6"A653DUMPSTER ENCLOSURE EAVE ROOF DETAIL80'3"6"0'3"6"A653DUMPSTER ENCLOSURE ROOF RAKE DETAIL90'4'8'0'4'8'A653DUMPSTER ENCLOSURE - WEST ELEVATION40'4'8'0'4'8'A653DUMPSTER ENCLOSURE - EAST ELEVATION50'4'8'0'4'8'A653DUMPSTER ENCLOSURE - 2 SECTION60'4'8'0'4'8'A653DUMPSTER ENCLOSURE - NORTH ELEVATION30'3"6"0'3"6"A653DUMPSTER GATE JAMB DETAIL110'1'2'0'1'2'A653DUMPSTER GATES ENLARGED PLAN101111111NO:ISSUED FOR: DATE:1 Addendum #205-25-20183PR#0027/17/18