Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (70).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 034 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 034 Date Created: 9/21/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ClarificationStructuralMetal Stair Dimensions Company Name Contact Name Copies NotesCc: Chamberlin Architects, Inc. Daniel Gartner 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 9/28/2018 Per detail 4 on architectural sheet A652, the vertical distance from the upper landing to the upper level is 6'-5 1/4". The detail calls out 11 risers with a maximum rise of 7" each. Please confirm it is acceptable to increase the height of the treads to meet the 6'-5 1/4" total vertical height. If the taller height is not acceptable, please provide a new detail with revised dimensions. Suggestion Answer Date Answered: 9/25/2018 THE UPPER LANDING ELEVATION IS INCORRECT AS SHOWN ON DETAIL 4 ON SHEET A652. THE UPPER LANDING ELEVATION SHOULD BE 109'- 8 1/2". THIS WOULD MAKE THE VERTICAL DISTANCE BETWEEN THE UPPER LEVEL AND THE UPPER LANDING 6'-3 1/2". THUS THE 11 EQUAL RISERS WOULD BE APPROXIMATELY 6 7/8" EACH. THE LOWER LANDING ELEVATION OF 102'-10 1/2" IS CORRECT. THE DISTANCE BETWEEN THE LOWER LANDING AND THE UPPER LANDING SHOULD BE 6'-10". THUS THE 12 EQUAL RISERS WOULD BE APPROXIMATELY 6 13/16" EACH. ON SHEET S103, CHANGE THE T.O. LANDING ELEVATION FROM 109'-6 3/4" TO 109'-8 1/2" AT STAIR 303 LANDING. ON SHEET S103, CHANGE THE T.O. WALL ELEVATION FROM 109'-4" TO 109'-8 1/2" AT SOUTH EXTERIOR WALL AT STAIR 303 LANDING. 2018.09.28 - JONATHAN WEST Prolog Manager Printed on: 9/28/2018 FCI_Integration Page 1 MAIN FLOOR 100' - 0" UPPER LEVEL 116' - 0" A B A612 6 1 1/2" DIA STL PIPE GUARD & HANDRAIL, TYP (PNT P6) 2" x 2" STL MESH GUARD INFILL, TYP (PNT P6)3' - 0" TYP3' - 6" TYP7" MAX EA5 RISERS @7" MAX EA12 RISERS @7" MAX EA11 RISERS @4' - 9 1/2" 10 TREADS @ 11" EA 9' - 2"5' - 9 1/2" 4' - 10 1/2" 11 TREADS @ 11" EA 10' - 1"4' - 9 1/2" 3' - 1"4" 4 TREADS @ 11" EA 3' - 8"4' - 10 1/2"2' - 3"COORDINATE W/ CIV EXTERIOR SIDEWAL STL TUBE GUARD TO MATCH STAIR GUARD CONSTRUCTION 102' - 10 1/2" LOWER LANDING 1' - 0" 109' - 6 3/4" LANDING TO NOSING OF STAIR 3' - 7" STAIR 303 SECTION @ STEPS4