Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (75).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 039 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 039 Date Created: 9/27/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ConfirmationArchitectural/StructuralCMU Block Clarification Company Name Contact Name Copies NotesCc: Chamberlin Architects, Inc. Daniel Gartner 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 10/4/2018 Please refer to the attached. Per phone and email correspondence between Jonathan with Chamberlin and FCI Constructors, the following questions have been answered: 1. Detail 3 on sheet A653 shows the trash enclosure is designed to have Type 1 and Type 2 ground face block. The specifications and color schedule only call out one type of split face block. - Per Jonathan, the trash enclosure should not be shown as ground face block. Construct the trash enclosure using the type 600R split face block veneer as specified. 2. Wouldn’t we want ground face CMU at the interior of the building (not split face)? There is nothing that we can see in the drawings that distinguishes areas of split face vs. ground face block. - Per Jonathan, Only the decorative exterior veneer is to be split-face. All interior 8" CMU to be regular (smooth-face) grey block. 3. We would want ground face block at locations below grade that receive waterproofing. That CMU block could be regular old grey block since no one will see it. Please confirm for us. - Per Jonathan, Yes. Provide 4" regular (Smooth-face) grey block at locations below grade. Suggestion Answer Date Answered: 9/27/2018 This RFI is for confirmation only. No response is required. Prolog Manager Printed on: 9/27/2018 FCI_Integration Page 1 1 Sam Meeks From:Jonathan West <jwest@chamberlinarchitects.com> Sent:Wednesday, September 26, 2018 2:29 PM To:Brady Blackmer; Sam Meeks; Daniel Gartner Cc:Brian Young Subject:RE: Aspen Ambulance CMU Type Brady… See my responses below in red. Let me know if you have any questions. Thanks, Jonathan Jonathan West, AIA, LEED GA C H A M B E R L I N A R C H I T E C T S G R A N D J U N C T I O N, C O • R A P I D C I T Y, S D 437 Main Street Grand Junction, CO 81501 Office (970) 242-6804 Fax (970) 422-7422 www.chamberlinarchitects.com From: Brady Blackmer [mailto:BBlackmer@fciol.com] Sent: Wednesday, September 26, 2018 8:02 AM To: Sam Meeks; Jonathan West; Daniel Gartner Cc: Brian Young Subject: RE: Aspen Ambulance CMU Type Importance: High Jonathan, Two other questions related to this: 1. Wouldn’t we want ground face CMU at the interior of the building (not split face)? There is nothing that we can see in the drawings that distinguishes areas of split face vs. ground face block. [Jonathan West] Interior block to be 8” regular (smooth-face) grey block. 2. We would want ground face block at locations below grade that receive waterproofing. That CMU block could be regular old grey block since no one will see it. Please confirm for us.[Jonathan West] Yes. Provide 4” regular (smooth-face) grey block at locations below grade. Right now, looking at the plans and specs, one would assume that it is all split face block…..[Jonathan West] Only the decorative exterior veneer is to be split-face. All interior 8” CMU to be regular (smooth-) face grey block. We can get this all into an RFI and get that to you tomorrow, but wanted to get these questions in front of you ASAP. Thanks. 2 Brady Blackmer Project Manager FCI Constructors, Inc. P.O. Box 1767 (81502) 3070 I-70 B, Bldg. A Grand Junction, CO 81504 P. (970) 434-9093 F. (970) 434-7583 C. (970) 433-1600 www.fciol.com Focused On Your Vision From: Sam Meeks Sent: Wednesday, September 26, 2018 7:44 AM To: Jonathan West (jwest@chamberlinarchitects.com) <jwest@chamberlinarchitects.com>; Daniel Gartner (dgartner@chamberlinarchitects.com) <dgartner@chamberlinarchitects.com> Cc: Brady Blackmer <BBlackmer@fciol.com>; Brian Young <BYoung@fciol.com> Subject: Aspen Ambulance CMU Type Jonathan, We were looking through the drawings and noticed that the elevations for the dumpster enclosure call out Ground Face CMU Type 1 and Ground Face CMU Type 2. The finish schedule on sheet A-741 only calls out one type of block, color 600R Split Face which has been submitted and approved. I wanted to verify with you if the dumpster enclosure requires ground face black as well as two different colors of block. Can you please confirm? Sam Meeks Engineer FCI Constructors, Inc. P.O. Box 1767 (81502) 3070 I-70 B, Bldg. A Grand Junction, CO 81504 P. (970) 434-9093 F. (970) 434-7583 C. (970) 618-8817 www.fciol.com Focused On Your Vision