Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (77).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 041 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 041 Date Created: 10/1/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ClarificationArchitecturalCMU Masonry at OH Doors Company Name Contact Name Copies NotesCc: Chamberlin Architects, Inc. Daniel Gartner 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 10/8/2018 Please refer to the attached drawing Please see the questions below regarding the CMU masonry at the OH door openings: 1. Per detail 2 and detail 6 on sheet A702, bullnose split face CMU is required where the CMU veneer returns back for the OH door openings. Per correspondence from the CMU veneer supplier this morning, it was stated that they do not make a split face bull nose CMU. Please confirm it is acceptable not to use any bull nose split face CMU block on this project as the plans call out. 2. Per detail 6 on sheet A702 CMU masonry is shown to return to the building behind the split face veneer. Is these CMU to be the grey ground face CMU black or the 4" split face veneer. (see attached mark up) 3. If the block that returns to the building is grey ground face CMU will the exposed block be required to be painted to match the interior of the apparatus bays? Please confirm finish of the exposed CMU. Suggestion Answer Date Answered: 10/1/2018 1. IT IS ACCEPTABLE TO NOT USE ANY BULL NOSE SPLIT-FACE CMU. PLEASE DISREGARD ANY REFERENCE TO BULL NOSE IN THE CDS. 2. PROVIDE 4" SPLIT-FACE CMU VENEER AT THESE LOCATIONS. 3. THE EXPOSED ENDS OF THE 8" CMU (INTERIOR BLOCK) IS TO BE PAINTED. THE DESIGN TEAM WILL CONFIRM THE P# AFTER WE HAVE REVIEWED THE METAL WALL PANEL SUBMITTAL. 2018.10.01 - JONATHAN WEST Prolog Manager Printed on: 10/1/2018 FCI_Integration Page 1 7 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED4"CONT SEALANT (TYP) PRE FINISHED MTL EDGE CAP W/ WEEP HOLES, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT WEATHER BARRIER FLASHING, LAP OVER MTL SILL FLASHING FLANGE PRE FINISHED MTL FLASHING W/ WEEP HOLES PRE FINISHED MTL DRIP FLASHING W/ HEMMED EDGE 6 PRE FINISHED MTL TRIM 7 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED2"CONT SEALANT (TYP) PRE FINISHED MTL EDGE CAP, RIVET TO MTL PANEL @ 12" O.C. W/ CONT SEALANT TAPE THERMALLY BROKEN 'C' GIRT PRE FINISHED MTL FLASHING 2" 6 9 CONT BACKER ROD & SEALANT (TYP) HM FRAME, PNT DOOR, RE: SCHED4"STL ANGLE, RE: STR (PNT) CONT SEALANT (TYP) WEATHER BARRIER OVER WEATHER BARRIER FLASHING WEATHER BARRIER FLASHING THROUGH WALL WEEPS & FLASHING 1' - 3" 6 9 CONT BACKER ROD & SEALANT (TYP) WEATHER BARRIER FLASHING HM FRAME, PNT DOOR, RE: SCHED GL CONT SEALANT (TYP) BULLNOSE EDGE 2"2" 6 11 WEATHER BARRIER OVER WEATHER BARRIER FLASHING STL ANGLE & PLATE, RE: STR (PNT) OH DOOR, RE: SCHED 0 WEATHER BARRIER FLASHING THROUGH WALL WEEPS & FLASHING GROUT CAVITY SOLID BELOW FLASHING 6 11 OH DOOR, RE: SCHEDULE 0 CONT BACKER ROD & SEALANT RETURN CMU VENEER @ JAMB 6" DIA CONCRETE FILLED BOLLARD. ALIGN WITH DOOR OPENING 1 1' - 0"1' - 6" BULLNOSE EDGE 3"1 1/2"2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 1 1/2"2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 3 2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 3 2"SEALANT, EA SIDE (TYP) HM FRAME, PNT DOOR, RE: SCHED 2 OVERHEAD DOOR, RE: SCHED MTL STUD HEADER, RE: STRUC 2 DOOR, RE: SCHED CORNER GAURD @ BOTH SIDES DOUBLE STUD AT JAMB, TYP. DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt9/25/2018 8:49:25 AMA702 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO DOOR DETAILS PROJECT STATUS: 100% CD KH JW ASPEN AMBULANCE DISTRICT FACILITY 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 73 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 74 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 91 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 92 0'3"6"0'3"6" A702 OH DOOR HEAD @ WALL TYPE 55 0'3"6"0'3"6" A702 OH DOOR JAMB @ WALL TYPE 56 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 1 & 27 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 1 & 28 0'3"6"0'3"6" A702 HM DOOR HEAD @ WALL TYPE 39 0'3"6"0'3"6" A702 HM DOOR JAMB @ WALL TYPE 310 0'3"6"0'3"6" A702 OH DOOR HEAD @ WALL TYPE 211 0'3"6"0'3"6" A702 OH DOOR JAMB @ WALL TYPE 212 NO: ISSUED FOR: DATE: 6 PR#010 9/25/2018 6 Is this CMU grey ground face or is this the split face veneer?If this is the grey ground face block, will this be painted block? Split face CMU is not made is a bullnose version.