Request for Information 043
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 043 Date Created: 10/4/2018
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ClarificationArchitectural/StructuralStair 302 Structural Steel
Company Name Contact Name Copies NotesCc:
Chamberlin Architects, Inc. Daniel Gartner 1
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
Question Date Required: 10/11/2018
Please refer to the attached model.
The questions below are related to the structural steel for Stair 302.
1. Please confirm the outside perimeter stringers will be exposed to view per 5/A652, while the inside stringers will be
concealed within the gyp of the "divider" wall per 5/A651.
2. Per the spec's, the stringers are to be designed to limit deflection to L/240 or ¼", whichever is less. A C12x20.7 stair
stringers are required, as it passes the L/240 requirement and barely passes ¼" deflection.
3. The lower flight of stairs will need a post located in the stud wall to support the 1st intermediate landing. The mid-flight
of stairs will require hanger columns to support the 2nd intermediate landing. Please confirm the W12x19 (on Grid I,
between 3.5-4.9) is adequate to support the roof column and also the loading from the stairs. MSW is conservatively
figuring 7kips of loading at each hanger will be applied to the W12x19.
4. Please refer to 5/A651. The detail depicts a smaller stringer is to be used, however as discussed in item #2 a C12x20.7
is required. The C12x20.7 has a 3" flange width. This 3" flange will cause issue with anchoring the ½" plate that caps off
the "divider" wall. Rather than using two separate pieces of wood blocking directly over the stud/channel, MSW would
propose to use a 2x12 that would be ripped down to the required width, then the threaded studs used to attach the ½"
plate to the 2x wood block would be offset as necessary to not interfere with the stringers.
5. Please advise what is desire for the stringer reveal at the exposed stringer, and also what is the reveal required for the
interior stringer. Per 5/A651, the gyp is to be attached directly to the stringer. MSW would like to make sure there is
enough channel at the nosing to allow for the gyp to attach.
6. What is the reveal dimension from the stair nosings up-to the top of the ½" plate on the "divider" wall?
7. PR #10 has eliminated the wood treads and now the polished concrete will be used. Is it acceptable to have a 1" return
on the stair pans at the nosing? This 1" return will be exposed.
a. Slip resistant nosings are not supplied by MSW.
Prolog Manager Printed on: 10/18/2018 FCI_Integration Page 1
Request for Information 043
Detailed, RFIs Grouped by RFI Number
8. Since the interior stair stringers are to be concealed within the "divider" wall, there is a challenge to make the mid-flight
stair nosings work out correctly. The layout shows the nosing to be held at the same location as the face of the gypboard.
This is causing the nosings to extend past the ends of the stringers by 5/8" at these landings (thickness of the gypboard).
Is this really what is wanted? Is there a way to shrink the tread width of the stairs and increase the thickness of the divider
wall to allow for the mid-flight tread to frame into the stringer?
9. Blackened steel was excluded and shop primer was figured in MSW's proposal. Please confirm this is acceptable.
(Note. MSW will not provide blackened steel. As an alternate, MSW could provide a High Performance Primer for
additional costs.)
10. MSW will provide countersunk holes for wood infill on guard railing posts. MSW is figuring one, countersunk, hole for a
1/8" wood screw for each piece of wood infill.
11. Please supply a detail on how the stair guardrail is to transition onto the upper floor level (how 5/A651 transitions to
5/A611). It appears that the "divider" wall will have a reveal that is greater than what the guardrail will have at the upper
floor. Per 5/A611, the guardrail at the upper floor level is to be a C7x9.8 with a 1" reveal above the slab. This transition
from the floor guardrail to the stair/"divider" wall guardrail will need to be worked out…especially at the base of the
guardrail, as the stair guardrail is depicted to incorporate 12 wood infills (2/A651) whereas the floor guardrail is depicted to
have 16 wood infills (5/A611)
a. 12 Sloping wood infills vs 16 flat wood infills
12. 2/A651 shows the general locations of the guardrail posts. Currently there is no post shown at the locate where the
wood infills "bend" from flat to sloping. Please confirm a post is not wanted here, and if one is needed please is the bend
is the wood is to be held at the stair nosing line. (each bend is directly above the other as depicted in 2/A651)
Suggestion
Answer Date Answered: 10/18/2018
1. CONFIRMED.
2. OK.
3. CONFIRMED. PROVIDE SKETCH FOR REVIEW & APPROVAL.
4. THIS IS ACCEPTABLE.
5. AT EXPOSED STRINGERS, REFER TO DETAIL 6/A652.
6. DIMENSION IS 2-9/16 INCH.
7. STAIR PAN TO MATCH PROFILE SHOWN ON DETAIL 6/A612.
8. STAIR TREAD TO ALIGN WITH 'DIVIDER' WALL DEPTH AS ILLUSTRATED IN THE CDS.
9. EXPOSED STEEL TO BE PAINTED P6 AS INDICATED IN ADDENDUM #2 DATED MAY 25, 2018. EXPOSED STEEL
TO BESHOP PRIMED.
10. GC TO CONFIRM WITH SUBCONTRACTOR PROVIDING & INSTALLINGWWOOD INFILL. REFER TO ATTACHED
REVISED SHEET A406, DETAIL 11 AND ATTACHED REVISED SHEET A611, DETAIL 5.
11. PROVIDE 1-INCH REVEAL BETWEEN STAIR STRINGER AND TOP TREAD TO ALIGN WITH 1-INCH" REVEAL AT
C7X9.8. REFER TO ATTACHED REVISED SHEET A651, DETAIL 5.
12. MODIFYYGUARDRAIL POST LAYOUT AS ILLUSTRATED IN THE ATTACHED REVISED SHEET A651, DETAIL 2.
2018.10.18 --JONATHAN WEST
Prolog Manager Printed on: 10/18/2018 FCI_Integration Page 2
5/A652 per Jonathan W.
6
FEP
UC REF
FEP
9
A622
________________________________________
12
A622
________________________________________
3
A621
________________________________________
7
A621
________________________________________
7
A622
________________________________________
4
A622
________________________________________
FILLER 2' - 0"2' - 9"1' - 6"1' - 6"2' - 6"1' - 7"9"2' - 6"1' - 8"2' - 10"2' - 1 1/2"2' - 9"1' - 6"1' - 6"2' - 6"1' - 7"6"CYPHER LOCK
(TYP OF 5)
APROXIMATE
AREA OF
COUNTERTOP
MEDICATION
DISPENSER
OUTLINE OF
DOOR OPEN
BASE, RE: FIN PLANS
4' - 6"
WIRE SHELVING W/ BINS,
RE: FURNITURE PLANS
6
BASE, RE: FIN PLANS
3' - 0"2' - 6"
C
LIGHT FIXTURES, RE: ELEC
DEEP WALL MOUNT OPEN
LOCKERS W/ POWER BAR
DEEP WALL MOUNT OPEN
LOCKERS W/O POWER BAR
DEEP WALL MOUNT OPEN
LOCKERS W/ BACKBOARD
RACK AND BASKET
6' - 0"1' - 0"JUNCTION BOXES @ POWER
BAR LOCATIONS , RE: ELEC
C
(6) 24" X 36" DEEP WALL
MOUNT OPEN LOCKERS W/
TOPSIDE STORAGE SHELF
LIGHT FIXTURES, RE: ELEC
AIR RETURN, MATCH HEIGHT
OF LIGHTS, RE: MECH
5 6
LIGHT FIXTURES, RE: ELEC
AIR RETURN, MATCH HEIGHT
OF LIGHTS, RE: MECH
(4) 24" X 36" DEEP WALL
MOUNT OPEN LOCKERS
W/ TOPSIDE STORAGE
SHELF
7' - 0"MOBILE 02
CYLINDER
SYSTEM
56
4"6' - 0"8"(3) 6' X 2' WALL MOUNT SLINGER TOOL
GRID PANEL W/ SLINGER TOPSIDE
WALL MOUNT SHELF ABOVE
BASE, RE: FIN PLANS
OXYGEN STORAGE ENCLOSURE,
PROVIDE DOORS, TOPSIDE
SHELF, AND ONE SHELF ABOVE
TANKS. OMIT BOTTOM SHELF
SO TANKS CAN REST ON FLOOR
EQEQEQEQ
STANDARDS AND BRACKETS,
(TYP) RE: SPECS. PROVIDE
BLOCKING
6 MELAMINE ADJUSTABLE SHELVES,
CONNECT AT SHELF SEAMS FOR
STABILITY (TYP)
2' - 0"
12
CONNECT SHELVES WHERE THEY MEET
AT CORNER FOR STABILITY (TYP)
BASE; RE: FINISH PLAN
2' - 0 1/2"
I
5
A611
________________________________________
STL BEAM, RE: STR (PNT P6)
STL CHANNEL, PNT P6
WD SLATS (TYP of 15)
WELDED STL ANGLE
FRAME, PNT P6
STL 2" X 1/4" PLATE
VERTICAL WELDED TO STL
ANGLE, PNT P6 (TYP OF 3)
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt10/18/2018 11:30:54 AMA406
OCTOBER 16,
2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
INTERIOR
ELEVATIONS
PROJECT STATUS: 100% CD
SH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'2'4'0'2'4'
A406
MEDICAL STORAGE - WEST1
0'2'4'0'2'4'
A406
MEDICAL STORAGE - SOUTH2
0'2'4'0'2'4'
A406
MEDICAL STORAGE - NORTH3
0'2'4'0'2'4'
A406
MEDICAL STORAGE - EAST4
0'2'4'0'2'4'
A406
READY ROOM - NORTH5
0'2'4'0'2'4'
A406
READY ROOM - SOUTH6
0'2'4'0'2'4'
A406
READY ROOM - EAST7
0'2'4'0'2'4'
A406
READY ROOM - WEST8
0'2'4'0'2'4'
A406
PANTRY 219 - NORTH9
0'2'4'0'2'4'
A406
PANTRY 219 - WEST10
0'2'4'0'2'4'
A406
WAITING 201 - NORTH IE11
NO: ISSUED FOR: DATE:
10 RFI#043 10/18/18
10
BASE, RE: FIN SCHED
WOOD SLAT (1 -1/2" X 1 -3/4")
FINISH NAILED TO WD BACKER
3/4" PWD W/ WD VENEER
ACOUSTICAL
BLANKET, RE: SPECS
TV SCREEN OR OTHER,
MOUNTED TO PWD
2
ACOUSTICAL
BLANKET, RE: SPECS
WOOD SLAT (1 -1/2" X
1 -3/4") FINISH NAILED
TO WD BACKER
3/4" PWD W/ WD VENEER
WD BACKER (1X4), PNT P6
WD BACKER (1X4), PNT P6
1/4"5/8" GYP BD ON 3 5/8" METAL STUDS @
24" OC MAX, RE: RCP FOR ELEVATIONS
3 5/8" METAL STUD KICKERS,
BRACED TO STRUCUTRE AT
48" OC MAX
6" METAL STUD HEADER
METAL STUDS @ 16" OC MAX
5/8" GYP BD ON 3 5/8" METAL
STUDS @ 24" OC MAX, RE: RCP
FOR ELEVATIONS
GYP BD ON 3 5/8" METAL STUDS @ 24"
OC MAX, RE: RCP FOR ELEVATIONS
CLG GRID EDGE TRIM, SHADOW
LINE MOLDING RE: SPEC
APC, RE: RCP
FOR ELEVATION
6" MTL STUD HEADER
METAL STUDS
@ 16" OC MAXMIN6"WOOD SLAT (1 -1/2" X 1 -3/4")
3
BLACKENED STL HSS 3" X 3" 1/8"
W/ 3" X 3" X 1/8" ATTACHMENT
PLATES WELDED @ 16" O.C.
ACOUSTICAL BLANKET,
RE: SPECS
WD BACKER (1X4), PNT P6
CONT WD BACKER (1X4), PNT P6
REVEAL1/4"REVEAL
1/4"4"1/2" WD 1 TRIM WITH 5/8"
BLOCKING BEHIND.
1/8" RADIUS AT TOP OF TRIM
AS SCHED
FLOOR TILE OVER CONCRETE
METAL EDGE STRIP
COVE, RE: SPECS
WALL TILE OVER BACKER
ALIGN, SET TRIM IN MORTAR BED TO
ALIGN WITH FACE OF TILE SO IT DOESN'T
BECOME A DIRT COLLECTION AREA
METAL EDGE STRIP
OUTSIDE CORNER,
RE: SPECS
WALL TILE
OVER BACKER
WALL TILE
OVER BACKER
METAL EDGE STRIP
BULLNOSE, RE: SPECS
WALL TILE
OVER BACKER
PAINT ADJACENT GWB
SHOWER UNIT, RE: SPECS
METAL EDGE STRIP OUTSIDE
CORNER, RE: SPECS
WALL TILE OVER BACKER
WALL TILE OVER BACKER
SHOWER UNIT FLANGE
SEAL
STL C7 X 9.8
CHANNEL, PNT P6
CONC SLAB, RE: STR
STL BEAM, RE: STR
(PNT P6)
HORIZONTAL STL
2" X 2" X 1/4"
ANGLE, PNT P6
WD 1 1/2" X 1 3/4"
SLATS FASTENED @
LANDING SIDE W/
COUNTERSUNK
SCREWS THROUGH
STL ANGLE
(TYP of 15)
VERTICAL STL 2" X
2" X 1/4" ANGLE
BEYOND, PNT P6
3 5/8" MTL STUD
KICKERS, BRACED TO
STRUCT @ 48" O.C.
MAX
6" MTL STUD
HEADER
3-5/8" MTL FRM'G
@ 16" O.C. MAX
5/8" GWB, PNT3' - 6"TYP1"1"DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt10/18/2018 11:37:43 AMA611
OCTOBER 16,
2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
INTERIOR DETAILS
PROJECT STATUS: 100% CD
SH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'6"1'0'6"1'
A611
FEATURE WALL @ TV1
0'3"6"0'3"6"
A611
GYP BOARD SOFFIT AT GYP CLG (TYP)9
0'3"6"0'3"6"
A611
GYP BOARD SOFFIT TO SAG10
0'3"6"0'3"6"
A611
FEATURE WALL CORNER DETAIL2
0'3"6"0'3"6"
A611
WOOD BASE TRIM8
0'3"6"0'3"6"
A611
TILE BASE DETAIL3
0'3"6"0'3"6"
A611
TILE OUTSIDE CORNER DETAIL7
0'3"6"0'3"6"
A611
TILE TOP OF WAINSCOT DETAIL4
0'3"6"0'3"6"
A611
TILE DETAIL @ SHOWER6
0'6"1'0'6"1'
A611
WOOD SLAT RAIL DETAIL5
NO: ISSUED FOR: DATE:
10 RFI#043 10/18/18
10
MAIN FLOOR
100' - 0"
UPPER LEVEL
116' - 0"
5 3
STL ANGLE
FRAME, PNT P6
STL HANDRAIL,
PNT P6
WD SLATS
STL PLATE,
PNT P6
11" EA
13 TREADS @
5
A651
________________________________________
A612
7
A652
5
A731
3
108' - 0"
LANDING 1
109' - 1 3/4"
LANDING 2@ 7" MAX EA12 RISERS2 RISERS @ 7" MAX EA@ 7" MAX EA14 RISERSSTRINGER RECESSED
IN WALL
E Q
E Q
E Q
10
G.9 I J
5
3
STAIR
302
ELEVATOR
301
2
A651
________________________________________
8' - 11 3/4"
2
2
2
2
5
7
7
3
A651
________________________________________
FD
ELEVATOR POWER
UNIT, RE: ELEC
2
UP 1' - 0"4' - 2 1/4"11"4' - 2 1/4"
3A
4' - 2 1/4"1
ASK-01
________________________________________
3.5
I J
4
5
3
2
A651
________________________________________
DN
A612
9
STAIR
302
A651
6
A612
8
7
7
2
2
2
4' - 2 1/4"11"4' - 2 1/4"4' - 2 1/4"3.5
MAIN FLOOR
100' - 0"
UPPER LEVEL
116' - 0"
3
ADHERED SHEET
WATERPROOFING (RE: SPECS)
@ PERIMETER OF CONC PIT,
LAP OVER FOUNDATION
CONC JOINT W/ CONT HYDROSTOP,
RE: SPECS
MTL STUD HEADER, RE: STR
FIRE CAULK GWB TO MTL DECK (TYP)
GWB ON 1-5/8" MTL STUDS
W/ BATT INSULATION
SAG CLG, RE: RCP
22
13
2
SUSPENDED GWB
CLG, RE: RCP
SUMP PUMP BEYOND
FLOOR DRAIN
SLOPE CONC TO DRAIN, 1/8":12"
FIRE PROOF ROOF DECK TO
1-HR ABV ELEVATOR SHAFT
CLR12' - 8"MIN2" CLRSLOPE 1/4" : 12"A641
4 3.5
HORIZONTAL STL 2" X 2" X
1/4" ANGLE, PNT P6
STL POST 2" X 2" X 1/4"
ANGLE BEYOND, FULL-WELD
ON STL PLATE, PNT P6
3
STL STRINGER RECESSED
IN WALL
POLISHED CONC STAIR TREAD
WD 1 1/2" X 1 3/4" SLATS FASTENED
@ LANDING SIDE W/ COUNTERSUNK
SCREWS THROUGH STL ANGLE
(TYP of 12)
STL HANDRAIL, PNT P6
1/2" STL PLATE, PNT P6
J-TRIM EDGE, EA SIDE
STL & CONC STAIR PAN
CONT 2X WD BLK'G
3 5/8" MTL FRM'G @ 16" O.C.
5/8" GWB
PNT P6
NUT W/ LOCK WASHER (TYP)
3/8" DIA ALL THREAD @ 24" O.C.
WELDED TO STL PLT (TYP)1"TYP1"3
1/4"1/4"1/4"1/4"
2"x2"x1/4" STL
POST, PNT P6
VERTICAL 2"x2"x1/4"
STL ANGLE, PNT P6
WD 1 1/2" X 1 3/4" SLATS
FASTENED @ LANDING SIDE
W/ COUNTERSUNK SCREWS
THROUGH STL ANGLE
STL PLATE BELOW, PNT P6 EQEQEQ EQ
DRAWN BY:CHECKED BY:
SHEET NO:
PROJECT NO:
DATE:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, Colorado 81501
T 970.242.6804
725 Saint Joseph St., Suite B1
Rapid City, South Dakota 57701
T 605.355.6804
www.chamberlinarchitects.com
E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N
C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt10/18/2018 11:41:29 AMA651
OCTOBER 16,
2018
1740
CASTLE CREEK ROAD
ASPEN, COLORADO
STAIR 302 &
ELEVATOR PLANS
& SECTIONS
PROJECT STATUS: 100% CD
SH, PH JW
ASPEN
AMBULANCE
DISTRICT FACILITY
0'2'4'0'2'4'
A651
STAIR 302 SECTION @ STEPS2
0'2'4'0'2'4'
A651
ENLARGED PLAN - STAIR 302/ELEVATOR MAIN FLOOR1
0'2'4'0'2'4'
A651
ENLARGED PLAN - STAIR 302 UPPER LEVEL4
0'1'2'0'1'2'
A651
ELEVATOR SECTION3
0'6"1'0'6"1'
A651
STAIR RAIL DETAIL5
0'3"6"0'3"6"
A651
STAIR RAIL DETAIL @ POST6
NO: ISSUED FOR: DATE:
10 RFI#043 10/18/18
10