Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (101).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 063 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 063 Date Created: 11/19/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ClarificationArchitecturalUpper Level Flooring Clarifications Company Name Contact Name Copies NotesCc: FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 FCI Constructors, Inc. - GJ Nick Stokes 1 Question Date Required: 11/26/2018 Please refer to attached. Please clarify the following questions on floor finishes at the 2nd floor per A162: 1.) Storage Room 228 is shown to receive Carpet 2. Per plumbing plans, water heaters will be installed in this room and there is a drain shown in this room. Should this floor finish be sealed concrete? 2.) At the door to Pantry 219, a "WD" designation is shown on the east side of this door appearing to denote a wood floor. However, Kitchen 218 is called to have polished concrete floors. Please confirm no wood flooring needed. Suggestion Answer Date Answered: 11/19/2018 Sealed concrete is acceptable in Room 228. Polished concrete floor is correct for Kitchen 218. Casey Sievila, Chamberlin Architects 11/19/2018 Prolog Manager Printed on: 11/19/2018 FCI_Integration Page 1 ..A B C D E G.9 I J 1 2 4 5 6 7 3 KITCHEN 218 DAYROOM 216 IT 211 TOILET 208 MECH/ELEC 209 CORRIDOR 210 LIBRARY / REPORTS 215 CONFERENCE 214 OFFICE 212 STOR. 213 WAITING 201 OFFICE 203 OFFICE 204 OFFICE 205 FLEX 206DINING 217 PANTRY 219 UNIFORM LOCKERS 221 SHOWER 227 STORAGE 228 BUNK RM 229 BUNK RM 230 BUNK RM 231 BUNK RM 232 CORRIDOR 224 CORRIDOR 220 MECH 223 LAUNDRY 222 SHOWER 226 P4 P1 P1P1APC CPT1 RUB - P4 P1 P1P1APC CPT1 RUB - P4 P1 P1P1APC CPT1 RUB - P5 P1 P1MWAPC CPT1 RUB - P1 P1 P1P1OTS-P6 PCONC WD - P1 P1 WDP1OTS-P6 PCONC WD - P1 P1 P1P1OTS - NO PNT CONC RUB - WD P1 P1P1OTS - P6 PCONC WD - P1 P1 P1P1APC CPT1 RUB - P1 P1 MWMWAPC CPT1 RUB - P1 P5 MWP1APC CPT1 RUB - P1 P1 P1P1APC CPT 1 RUB - P1 P1 P1P1APC CONC RUB 1 P1 P1 P1P1OTS-P2 CONC RUB - P1 P1 P1P1APC CPT1 RUB - P1 P1 P1P1APC PCONC RUB - P1 P1 P1P3APC CPT2 RUB - P1 P1 P1P3APC CPT2 RUB - P1 P1 P1P3APC CPT2 RUB - P1 P1 P1P3APC CPT2 RUB - T2-4/P1 T2-4/P1 T2-4/P1T2-4/P1P2 T1 T1 1 T2-4/P1 T2-4/P1 T2-4/P1T2-4/P1P2 T1 T1 1 T2-4/P1 T2-4/P1 T2-4/P1T2-4/P1P2 T1 T3 1 P1 P1 P1P1APC CPT2 RUB - P1 P1 P1P1APC CPT2 RUB - F PCONC CPT1 PCONC CPT1 PCONC CPT1 CONC CPT2 CONCRUB2 PCONC CPT 2 T1 CPT 2 T1 CPT 2 T1 CPT1 PCONC CPT1 CPT1 CPT1 PCONC CONCT14' - 0" ALIGN CPT 1 OVER PCONC ALIGN T2-4/P1 T2-4/P1 T2-4/P1T2-4/P1P2 T1 T3 1 P1 P1 P1P1OTS - NO PNT CONC RUB CPT1 CPT2 STAIR 303 P1 P1 P1P1OTS - P2 RUB 2 RUB STAIR 302 - P1 P1P1OTS-P6 WD - - P1 P1 WDP1OTS-P6 PCONC WD 1 0 G DN CONC PCONC PCONC WD 3 A703 ________________________________________ (WITHOUT DOOR) OPEN TO BELOW 3.5 7 7 WALL FINISHES P# - CMU OR GYPSUM WALLBOARD W/ PAINT. MW -CLEAR MARKER WALL PAINT OVER GWB PAINTED P1 WITH A LEVEL 5 GWB FINISH. RE: VISUAL DISPLAY SPECIFICATION SECTION. FRP - FIBERGLASS REINFORCED PANEL. T# - TILE. WD - WOOD FEATURE WALL. CEILNG FINISH APC - SUSPENDED ACOUSTICAL PANEL CEILING GRID AND TILE. P# - GYPSUM WALLBOARD WITH PAINT. OTS - OPEN TO STRUCTURE. PAINT COLOR AS NOTED. FLOOR FINISHES CPT# - CARPET T# - FLOOR TILE. PCONC - POLISHED CONCRETE. CONC - SEALED CONCRETE. RUB - RUBBER ATHLETIC FLOORING. EM - RECESSED ENTRY MAT, RE: SPECS. WD - WOOD STAIR TREADS, RE: SPECS. BASE FINISHES T# - TILE BASE. RUB - RUBBER BASE. WD - WOOD W/ TRANSPARENT FINISH, RE: 5/A611. FINISH NOTES 1. PROVIDE EPOXY PAINT ON WALLS AND CEILINGS IN WET AREAS. AMBULANCE BAYS, BATHROOMS, SHOWERS, KITCHEN BACKSPLASH WALL, JANITOR AND DECON. 2. PROVIDE FRP AS SHOWN ON ELEVATIONS. PROVIDE TOP AND BOTTOM EDGE TRIM AND DIVISION TRIM, RE: SPECS. 3. IMPACT RESISTANCE GWB TO 4'. 4. USE 13X20 INCH SIZE TILE IN THE ELEVATOR. 5. PROVIDE PWD FOR MOUNTING EQUIPMENT BEHIND DRYWALL ON ALL WALLS (TYP) UP TO 12 FEET. 6. SEAL AT JOINT BETWEEN CMU AND CONCRETE FLOOR. CPT1 WD 1,2 P1 DHP1P1SAT FLOOR FINISH BASE FINISH FINISH NOTES CEILING FINISH WALL FINISH (NORTH, SOUTH, EAST, WEST) NOTE: COLORS, RE: INTERIOR COLOR SCHEDULE A741 PATTERN AT WALLS, RE: INTERIOR ELEVATIONS A401-A406 PATTERN AT CEILINGS, RE: REFLECTED CEILING PLAN A121-A122 FLOOR FINISH TRANSITIONS, RE: A703 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt10/3/2018 11:26:12 AMA162 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO UPPER INTERIOR FINISH PLAN PROJECT STATUS: 100% CD SH CS ASPEN AMBULANCE DISTRICT FACILITY 0'4'8'0'4'8' A162 UPPER LEVEL FINISH PLAN1 NO: ISSUED FOR: DATE: 7 ASI#002 10/3/2018 Please confirm if the strorage is to have Carpet 2 for flooring. Kitchen is called to have a polished concrete floor. Please confirm "WD" is not accurate.