Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (106).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 068 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 068 Date Created: 12/11/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ConfirmationArchitecturalExterior Wall Vapor Barrier Deletion Company Name Contact Name Copies NotesCc: FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 FCI Constructors, Inc. - GJ Nick Stokes 1 Question Date Required: 12/18/2018 Please refer to attached. Per architectural drawing A001, wall types 5, 6, 6A, 7 and 7A all include a vapor barrier that is shown to be installed between the interior layer of 5/8" gypsum board and the insulation within the 6" metal stud framing. Per conversations between Jonathan West with Chamberlin Architects and Sam Meeks with FCI on 12/11/18, it was confirmed that the vapor barrier that is shown for these 5 wall types will no longer be required. Suggestion Answer Date Answered: This RFI is for confirmation only. No response is required. Prolog Manager Printed on: 12/11/2018 FCI_Integration Page 1 REVISION ELEVATION COLUMN GRID LOCATION DOOR NUMBER WINDOW TYPE CENTER LINE LINE OF WALL ABOVE OR HIDDEN LINE BREAK LINE MATCH LINE ROOM NAME ROOM NUMBER BASIC WALL TYPE A101 1 2 3 4 A 101A Room 101 1 A101 TYP 1 A101 TYP ANGLE DIAMETER PERPENDICULAR PLATE PLUS OR MINUS FLOOR DRAIN FIRE EXTINGUISHERFE FD 1 1 100' 0" TOP OF WALL AL HM INTERIOR WALL ELEVATION REFERENCE DRAWING REFERENCED SECTION NUMBER SHEET NUMBER REFERENCED DETAIL NUMBER SHEET NUMBER 1. COMPLY WITH ALL MANUFACTURERS RECOMMENDATIONS AND INDUSTRY STANDARDS RELEVANT TO THE WORK HEREIN. 2. ALL DIMENSIONS ARE FROM FACE OF FINISH UNO. 3. ALL ALIGNMENTS ARE FACE OF FINISH UNO. 4. FIELD VERIFY ALL DIMENSIONS AND ROUGH OPENINGS PRIOR TO FABRICATION AND/OR INSTALLATION. ABV above ACC accessories ADJ adjustable AFF above finished floor ALT alternate AL aluminum APC acoustical panel ceiling ARCH architect (ural) ASPH asphalt A/C air conditioning BCS baby changing station BD board BLDG building BLKG blocking BO bottom of BRG bearing CBU cemetitious backer unit CG corner guard CIP cast in place CJ control joint CLG ceiling CLR clear (ance) CMU concrete masonry unit COL column CONC concrete CONT continuous or continue CORR corridor CPT carpet (ed) CSMT casement CT ceramic tile CTR center CU condenser unit CWOG center wall on grid DBL double DEMO demolish / demolition DF drinking fountain DIM dimension (s) DIR direction DISP dispenser DN down DR door DS downspout DTL detail DWG drawing DWR drawer E east EA each EC evaporative cooler EG etched glass/glazing EIFS exterior insul finish sys EJ expansion joint EL elevation ELEC electric (al) EM emergency EWC electric water cooler EWG end wall corner guard EQ equal EXG existing EXH exhaust EXP exposed EXT exterior FBO furnished by owner FD floor drain FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FEP finished end panel FFE finished floor elevation FIN finish FLG flashing FLR floor (ing) FLUR fluorescent FO face of FRMG framing FRP fiber reinforced plastic FT foot (feet) FTG footing GA gage, gauge GAL gallon GALV galvanized GB grab bar GC general contractor GL glass, glazing GWB gypsum wallboard GYP gypsum HAS headed anchor stud HB hose bibb HCP handicap (ed) HDR header HDW hardware HM hollow metal HOR horizontal HR hose reel HSS hollow structural sections HT height HVAC heating /ventilation /air conditioning HWD hardwood INCL include (d) (ing) INSUL insulate (d) (ing) INT interior INV invert JST joist JT joint L length, angle LAM laminate (d) LAV lavatory LB pound LF lineal foot LG laminated glass, glazing LIN linoleum LT light MA match MAS masonry MATL material MAX maximum MB marker board MECH mechanic (al) MFR manufacture (r) (d) MH manhole MIN minimum MISC miscellaneous MLD molding, moulding MO masonry opening MT mount (ed) (ing) MTL metal N north N/A not applicable NIC not in contract NOM nominal NTS not to scale NECY necessary OC on center (s) OD outside diameter OFCI owner furnished, contractor installed OFD overflow drain OFOI owner furnished, owner installed OH overhead OL occupant load OLF occupant load factor OPG opening OPH opposite hand OPP opposite OSB oriented strand board OTA open to above OTS open to structure PB particle board PERF perforate (d) PERIM perimeter PG pattern glass PLAM plastic laminate PLT plate PNL panel PNT paint (ed) PR pair PROJ projector, projection PSF pounds per square foot PSI pounds per square inch PT pressure treated PTD paper towel dispenser PTN partition PVC polyvinyl cholride PVMT pavement PWD plywood QT quarry tile R riser, radius RB rubber base REC recycling RCMD recommend (ed) (ations) RE reference REF refrigerator REIN reinforce (d) (ing) REQ required REV revision (s), revised RD roof drain RFG roofing RH robe hook RM room RO rough opening ROW right of way RR restroom RTU roof top unit RUB rubber S south SAG susp acoustic grid SC shower curtain rod & hooks SCH schedule SD soap dispenser SHT sheet SHTG sheathing SIM similar SND sanitary napkin dispenser SNV sanitary napkin vendor SPEC specification SPKR speaker SQ square SS solid surface SST stainless steel STD standard STL steel STOR storage STR structural SUSP suspended T tread TB towel bar TEL telephone TG tempered glass THK thick T.O.top of TOC top of concrete TOS top of steel TOW top of wall TPD toilet paper dispenser TS tube steel TYP typical T&G tongue and groove UCR undercounter refigerator UNO unless noted otherwise VB vapor barrier VCT vinyl composition tile VERT vertical VIF verify in field VM vending machine VNL vinyl sheet VTR vent through roof W west, wide, width W/with WB wood base WC watercloset WD wood WDW window WF wide flange WG wire glass W/O without WP waterproof (ing) WR waste receptacle WRB weather resistive barrier WWM welded wire mesh WALL TYPE NOTES: 1. ALL EXTERIOR WALL TYPES ARE SHOWN WITH THE EXTERIOR WALL FACING RIGHT UNLESS OTHERWISE NOTED. 2. PROVIDE GLASS MAT WATER-RESISTANT BACKER BOARD IN LIEU OF GYPSUM WALL BOARD BEHIND ALL WALL TILE. 3. GYPSUM BOARD SHALL BE MOISTURE-RESISTANT AT THE FOLLOWING LOCATIONS: WALLS AND CEILINGS OF ALL RESTROOMS AND SHOWERS 4. WALL TYPE CHANGES OCCUR AT CORNERS OR INTERSECTIONS OF WALLS UNLESS NOTED OTHERWISE. 3-5/8" MTL STUDS @ 16" O.C. 5/8" GYP BD, EA SIDE. (ONE SIDE @ 1A) SOUND ATTN BATTS 5" ACOUSTICAL SEALANT, EA SIDE. FIRE CAULK IN LIEU OF @ FIRE RARTED LOCATIONS MTL RUNNER CHANNEL FLOOR LINE1/2"METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK CONT FIRE CAULK GWB TO DISSIMILAR MATERIALS, EA SIDE UL -U419 -1/2 HR RATED, STC: 49 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, EA SIDE (ONE SIDE @ 2A) SOUND ATTN BATTS 7 1/4" METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 1"UL -U419 -1 HR RATED @ STAIR & ELEVATOR 6" MTL STUDS @ 16" O.C. 5/8" GYP BD 1/2" EXT SHEATHING 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS AIR SPACE 4" CMU VENEER 1' - 4 1/4" VAPOR BARRIER MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 6" MTL STUDS @ 16" O.C. (10" @ 6A) 5/8" GYP BD 1/2" EXT SHEATHING 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS PRE-FINISHED HORIZONTAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' CLIPS SPACED VERTICALLY @ 24" O.C. VAPOR BARRIER 8" CIP CONC, RE: STR GL 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS OMIT WEATHER BARRIER & XPS INSULATION @ WALL TYPE 8A 10 1/2" 11" @ 3A 10" (2) 3-5/8" MTL STUDS @ 16" O.C. 5/8" GYP BD, EA SIDE SOUND ATTN BATTS ACOUSTICAL SEALANT, EA SIDE. FIRE CAULK IN LIEU OF @ FIRE RARTED LOCATIONS MTL RUNNER CHANNEL FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK UL -U493 -1 HR RATED, STC-59 CONT FIRE CAULK GWB TO DISSIMILAR MATERIALS, EA SIDE 1 - 1/2" AIR SPACE (2 1/2" @ 3A) ALUM STOREFRONT, NON-THERMALLY BROKEN UNINSULATED GLAZING METAL DECK 1"4 1/2" (6" @ 4A) ACOUSTICAL SEALANT, EA SIDE FLOOR LINE WALL TYPE ABV, 1 @ 4 1/2", 2 @ 6"2 1 CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 6" MTL STUDS SISTERED TO 6" MTL STUDS @ 16" O.C. 5/8" GYP BD 1/2" EXT SHEATHING. 5/8" EXT SHEATHING @ 7A 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS PRE-FINISHED VERTICAL MTL PNL ATTACHED TO THERMALLY BROKEN 'Z' GIRTS SPACED HORIZONTALLY @ 24" O.C. VAPOR BARRIER 1' - 4 3/4" UL -U419 -1 HR RATED @ 7A 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS 8" CONC (12" CONC @ 9A), RE: STR AIR SPACE 4" CMU VENEER 1' - 5 5/8" 1-HR RATED, per TABLE 721.1(2), 4-1.1. MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY GL 8" CMU, RE: STR 7/8" MTL FURRING CHANNELS @ 16" O.C. @ 10A 5/8" GYP BD @ 10A 9 1/4" 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, EA SIDE SOUND ATTN BATTS 7 3/4" METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"1/2" PWD CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK 2.5" THK (R-15 MIN) RIGID INSULATION W/ TAPED & SEALED SEAMS 8" CMU, RE: STR AIR SPACE 4" CMU VENEER 1' - 4 1/2" MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 6" MTL STUDS @ 16"O.C. 5/8" GYP BD, ONE SIDE SOUND ATTN BATTS METAL DECK ACOUSTICAL SEALANT, EA SIDE MTL RUNNER CHANNEL FLOOR LINE1/2"4" CMU VENEER 1/2" PWD. 5/8" EXT SHEATHING @ 2D CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK MASONRY VENEER TIES @ 16" VERTICALLY & HORIZONTALLY 1' - 0 3/4" UL -U419 -1 HR RATED @ 2D 12" CIP CONC, RE: STR GL ACOUSTICAL SEALANT, ONE SIDE. FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES ACOUSTICAL SEALANT, ONE SIDE. 7/8" MTL FURRING CHANNEL @ 16" O.C. 5/8" GYP BD, ONE SIDE. NOT USED 2-1/2" MTL STUDS @ 16" O.C. 5/8" GYP BD, ONE SIDE ACOUSTICAL SEALANT, ONE SIDE. MTL RUNNER CHANNEL FLOOR LINE METAL DECK CONT COMPRESSIBLE INSULATION IN DECK FLUES MTL STUD SLIP TRACK @ METAL DECK ACOUSTICAL SEALANT, ONE SIDE. FULLY ADHERED SINGLE PLY ROOF MEMBRANE 1/2" COVER BOARD R-35 RIGID INSULATION VAPOR BARRIER MTL ROOF DECK, RE: STR DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTSBIM 360://1740 - Pitkin County Ambulance Facility/1740-PCAF_CA.rvt11/6/2018 10:08:34 AMA001 OCTOBER 16, 2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO NOTES, SYMBOLS, ABBREVIATIONS AND WALL TYPES PROJECT STATUS: 100% CD SH JW ASPEN AMBULANCE DISTRICT FACILITY SYMBOLS GENERAL NOTESARCHITECTURAL ABBREVIATIONS 0'6"1'0'6"1' A001 WALL TYPES1 WALL TYPE 1 & 1A WALL TYPE 2 & 2A WALL TYPE 5 WALL TYPE 6 & 6A WALL TYPE 8 & 8A WALL TYPE 3 & 3A WALL TYPE 4 & 4A WALL TYPE 7 &7A WALL TYPE 9 & 9A WALL TYPE 10 & 10A WALL TYPE 2B WALL TYPE 11 WALL TYPE 2C & 2D WALL TYPE 12 WALL TYPE 1B WALL TYPE 13 WALL TYPE 14 CLASS 'A' ROOF ASSEMBLY NO: ISSUED FOR: DATE: 2 Response to City of Aspen Review Comments 7/16/18 6PR#010 9/25/18