Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (121).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 083 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 083 Date Created: 2/6/2019 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ConfirmationArchitecturalB23 & B22 Window Dimensions Company Name Contact Name Copies NotesCc: FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 2/13/2019 Refer to attached. Per architectural drawing A102, Bunk Rooms 230, 231 and 232 all have a B23 window in the west wall of the room. Per drawing A102 the B23 windows are to be 3'-0" wide. The windows have been fabricated at 3'6" wide in lieu of the 3'0" wide as designed. Per discussions between Jonathan West with Chamberlin and Brian Young with FCI, it has been confirmed that it is acceptable to install the 3'-6" wide B23 Windows. The south edge of the window must be installed in the same location as shown on the drawings and will extend 6" further to the north. Per architectural drawing A102, Laundry 222 is to have a B22 window in the south wall of the room. Per drawing A102 the B23 windows are to be 3'-0" wide. The windows have been fabricated at 3'0" wide in lieu of the 3'6" wide as designed. Per discussions between Jonathan West with Chamberlin and Brian Young with FCI, it has been confirmed that it is acceptable to install the 3'-0" wide B23 Windows. Suggestion Answer Date Answered: This RFI is for record only. No response is required. Prolog Manager Printed on: 2/6/2019 FCI_Integration Page 1 ..A202 2 CORRIDOR 220 UNIFORM LOCKERS 221 LAUNDRY 222 CORRIDOR 224 SHOWER 225 SHOWER 226 BUNK RM 230 BUNK RM 231 BUNK RM 232 221 220 225 226 230 231 232 303D KITCHEN 218 MECH 223 3 A513 ________________________________________ 223 222 6 2 1 2 11 1 1A1A 1A1A 22 1 B21 2 A302 7 216 6 7 A652 3 STAIR 303 9 3/4"9' - 0"12' - 8 3/4"3' - 0"19' - 0"16 1' - 0"29' - 4 1/4"3' - 6"4' - 5" CTR WALL ON GRID LINE 10' - 0"6' - 9"4' - 3 1/4"11' - 10"22' - 5"59' - 9 1/4"8' - 0 1/4"6' - 10 1/4"5' - 10 1/2"5' - 10 1/4"8' - 1 1/4"9' - 5"9' - 5"9' - 0"CTR WALL ON GRID LINE CTR WALL ON GRID LINE 7A 7A B23 B22 A301 5 B23 B23 1 A644 ________________________________________10' - 11"10' - 11"6A R RD R bulance Facility/1740-PCAF_CLOUD.rvtB23 Windows B22 Window