HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (123).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 085
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 085 Date Created: 2/14/2019
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ConfirmationArchitecturalFront Entry Canopy Soffit
Company Name Contact Name Copies NotesCc:
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
FCI Constructors, Inc. - GJ Javier Garcia 1
Question Date Required: 2/21/2019
Please refer to the attached.
Per detail 1 on architectural sheet A642, there is a 1"x6" tongue and groove soffit made from select white birch that is to
be installed at the underside of the front entry canopy. Per the detail, the tongue and groove material is to be fastened to
the metal Z-girts. To fasten the tongue and groove material to the z-girts the fasteners would be exposed to view. Per
phone conversation between Jonathan West with Chamberlin and Sam Meeks with FCI, it was confirmed that the rigid
insulation would be reduced to 2" and a 1/2" layer of fire treated plywood would be added between the insulation and the
soffit material. The plywood will allow the soffit material to be installed and the fasteners to be almost completely hidden
from view.
Suggestion
Answer Date Answered:
This RFI is for confirmation only. No response is required.
Prolog Manager Printed on: 2/14/2019 FCI_Integration Page 1
ROOF MEMBRANE FLASHING
W/ CONT EDGE SEALANT
PRE FINISHED MTL ROOD EDGE
FLASHING W/ CONT GALV CLEAT
LAP ROOF MEMBRANE OVER WEATHER
BARRIER FLASHING & DOWN FASCIA
4"2
2
2
6
6
10
WEATHER BARRIER FLASHING, LAP
OVER TOP OF PARAPET
MTL 'C' GIRT @ TOP & BOTTOM OF
FRM'G FOR INSULATION ATTACHMENT
PRE FINISHED MTL FASCIA W/ FLAT
LOCK SEAM @ VERTICAL JOINTS
113' - 4 1/2"
T.O. CANOPY
26
111' - 7 1/4"
B.O. CANOPY
2.5" RIGID INSULATION @ FASCIA &
SOFFIT
PT WD 2x BLK'G (TYP)
CONT PT WD 2x @ CANOPY SOFFIT
PERIMETER
WRAP PRE FINISHED MTL FASCIA
FLASHING OVER BLK'G & ATTACH
BELOW SOFFIT FINISH
CONT BACKER ROD & SEALANT (TYP)
1x6 WD PLANK SOFFIT FINISH ON 3" MTL 'Z' GIRTS
W/ RIGID INSULATION
WEATHER BARRIER ON 1/2" EXT SHEATHING ON 7/8"
MTL FURRING ATTACHED TO STL BEAMS, RE: STR
FILL CANOPY CAVITY W/ BATT INSULATION
SINGLE PLY ROOF MEMBRANE ON 1/2" COVER
BOARD ON TAPERED RIGID INSULATION ON MTL
ROOF DECK, RE: STR
4' - 3"
6
Reduce rigid insulation
from 2 1/2" to 2"
Install one layer of 1/2" fire treated
plywood
Fasten tongue and groove soffit
to the layer of plywood
Detail 1/A642