Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (126).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 088 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 088 Date Created: 2/22/2019 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ConfirmationArchitectural/StructuralGridline 4 Deck Edge Dimension Clarification Company Name Contact Name Copies NotesCc: FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 FCI Constructors, Inc. - GJ Javier Garcia 1 Question Date Required: 3/1/2019 Please refer to the attached. In reference to the deck edge on the upper level along gridline 4, there is a discrepancy between the architectural & structural details. Detail 4/A644 shows the deck edge to be 5" off of 4 line and detail 5/S301 shows 3". Per conversation between Jonathan and Brian it is acceptable to extend the studs that are shown under the deck edge to the top of deck and we will hold the 5" dimension from gridline 4 as shown on 4/A644. The studs will be 1-5/8", 20 ga. spaced @ 12"oc (see attached marked up detail). Suggestion Answer Date Answered: This RFI is for confirmation only. No response is required. Prolog Manager Printed on: 2/22/2019 FCI_Integration Page 1 0'-3" 1-5/8", 20 ga @ 12"oc extend to top of concrete Deck edge per structural