HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (126).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 088
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 088 Date Created: 2/22/2019
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ConfirmationArchitectural/StructuralGridline 4 Deck Edge Dimension Clarification
Company Name Contact Name Copies NotesCc:
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
FCI Constructors, Inc. - GJ Javier Garcia 1
Question Date Required: 3/1/2019
Please refer to the attached.
In reference to the deck edge on the upper level along gridline 4, there is a discrepancy between the architectural &
structural details. Detail 4/A644 shows the deck edge to be 5" off of 4 line and detail 5/S301 shows 3". Per conversation
between Jonathan and Brian it is acceptable to extend the studs that are shown under the deck edge to the top of deck
and we will hold the 5" dimension from gridline 4 as shown on 4/A644. The studs will be 1-5/8", 20 ga. spaced @ 12"oc
(see attached marked up detail).
Suggestion
Answer Date Answered:
This RFI is for confirmation only. No response is required.
Prolog Manager Printed on: 2/22/2019 FCI_Integration Page 1
0'-3"
1-5/8", 20 ga @ 12"oc extend to top of concrete
Deck edge per structural