Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (128).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 090 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 090 Date Created: 3/13/2019 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ConfirmationArchitectural/ElectricalAccess Control & Security Camera Submittal Clarifications Company Name Contact Name Copies NotesCc: FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ Javier Garcia 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 Question Date Required: 3/20/2019 Per the attached Access Control and Security Camera submittal, the following clarifications have been made per the review completed by Chamberlin. 1. Emergency power is to be supplied by the generator to the access control panel. 2. One of the security camera locations is to be deleted at Apparatus Bay #1 3. An additional door release button is to be added in corridor 202 adjacent to door 201. This door release button is to be tied into the other door release buttons which release door 101. The clarifications above will now become part of the project documents. Suggestion Answer Date Answered: This RFI has been created for confirmation only. No response is required. Prolog Manager Printed on: 3/13/2019 FCI_Integration Page 1 Detailed, Grouped by Each Number includes Sub Section Submittal Transmittal FCI Constructors, Inc. - GJAspen Ambulance District Facility Project # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 Date: 3/12/2019 Reference Number: 0280 Transmitted To:Transmitted By:Sam MeeksChad Hendrickson Convergint Technologies FCI Constructors, Inc. - GJ 7330 S. Alton Way, Unit 12K Centennial, CO 80112 Tel: 303-932-0757 Fax: none P. O. Box 1767 Grand Junction, CO 81502 Tel: 970-434-9093 Fax: 970-434-7583 Submittal Package No Description Due Date Package ActionQty Approved as NotedAccess Control - Shop Drawings & Product Data281500.01 - - 06 Transmitted For Delivered Via Tracking Number EmailYour Files & Records Item ActionItems DescriptionQty Sub SectionSpec Section 1 Access Control - Product Data Approved as Noted 281500 2 Access Control - Shop Draiwngs Approved as Noted 281500 3 Access Control - Interior Cameras Approved as Noted 281500 4 Access Control - Exterior Cameras Approved as Noted 281500 5 Access Control - Card Readers Approved as Noted 281500 6 Access Control - Access Control Head End System Approved as Noted 281500 Contact Name Copies NotesCompany NameCc: FCI Constructors, Inc. - GJ Javier Garcia 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 Remarks Signature Signed Date Prolog Manager Printed on: 3/12/2019 FCI_Integration Page 1 SUBMITTAL REVIEW MEMORANDUM Date: March 11, 2019 From:Jonathan West To: FCI Constructors, Inc. Project Name: AADF PO Box 1767 Grand Junction, CO 81502 Project No.: 1740 Attn: Sam Meeks Checking is only for general conformance with the design concept of the project and compliance with the information given in the Contract Documents. Any action shown is subject to the requirements of the plans and specifications. Contractor is responsible for dimensions which shall be confirmed and correlated at the job site, fabrication processes and techniques of construction, coordination of his or her work with that of all other trades; and the satisfactory performance of his or her work. We have reviewed the following submittals and have the following comments: Item Submitted Received No Exceptions taken Make Corrections Noted Revise and Resubmit Rejected 281500.01 Access Control 2/6/19 x No Exceptions Taken: Submission conforms to requirements of the Contract Documents. Make Corrections as Noted: Address items as noted for conformance with Contract Documents. Revise and Resubmit: Revise as noted and resubmit for review. Other items conform, U.N.O. Rejected: Submission does not conform to requirements - see remarks below. Remarks: 1. The proposed access control panel is wall-mounted rather than rack-mounted as shown in the CDs. Provide generator backed power to the proposed control panel location. 2. Black is an acceptable color for all card readers. 3. Delete camera adjacent to Apparatus Bay #1. All other camera locations confirmed to be acceptable by the Owner. 4. Provide door release button (DR) in Corridor 202 adjacent to Door 201. 5. Security cameras to be tied into the AVH system for monitoring. Detailed, Grouped by Each Number includes Sub Section Submittal Transmittal FCI Constructors, Inc. - GJAspen Ambulance District Facility Project # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 Date: 2/6/2019 Reference Number: 0240 Transmitted To:Transmitted By:Sam MeeksJonathan West Chamberlin Architects, Inc.FCI Constructors, Inc. - GJ 437 Main Street Grand Junction, CO 81501 Tel: 970-242-6804 Fax: 970-245-4303 P. O. Box 1767 Grand Junction, CO 81502 Tel: 970-434-9093 Fax: 970-434-7583 Submittal Package No Description Due Date Package ActionQty Pending Approval2/20/2019Access Control - Shop Drawings & Product Data281500.01 - - 06 Transmitted For Delivered Via Tracking Number E-MailApproval Item ActionItems DescriptionQty Sub SectionSpec Section 1 Access Control - Product Data Pending Approval281500 2 Access Control - Shop Draiwngs Pending Approval281500 3 Access Control - Interior Cameras Pending Approval281500 4 Access Control - Exterior Cameras Pending Approval281500 5 Access Control - Card Readers Pending Approval281500 6 Access Control - Access Control Head End System Pending Approval281500 Contact Name Copies NotesCompany NameCc: FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 FCI Constructors, Inc. - GJ Javier Garcia 1 Remarks Signature Signed Date Prolog Manager Printed on: 2/6/2019 FCI_Integration Page 1 DESCRIPTIONMANUFACTURERPART NUMBEREQUIPMENT LEGENDSYMBOLSITE PLANScale: N.T.S.NPROVIDED BYCONVERGINT TECHNOLOGIES LLC HAS BEEN CONTRACTED TO INSTALL A NEW ACCESS CONTROLSYSTEM ON THE 2ND FLOOR IN IT ROOM 211. THE WORK INCLUDES THE INSTALLATION OF THENEW ACCESS CONTROL PANEL AND POWER SUPPLY. THE ACCESS CONTROL PANEL WILL TIEINTO THE NETWORK VIA A COMMUNICATION CABLE. THE NEW ACCESS CONTROL PANEL ANDPOWER SUPPLY ARE GOING TO SUPPORT (8) DOORS. THE DEVICES SUPPORTED INCLUDE: CARDREADER(S), ELECTRIFIED LEVER SET(S), DOOR CONTACT(S), A FIRE ALARM RELAY MODULE WILLBE PROVIDED BY OTHERS FOR FIRE ALARM INTERFACE.ASPEN AMBULANCE401 CASTLE CREEK ROADASPEN, CO 81611ACCESS CONTROLProject Manager: ED STEPHENSPhone #: 303-932-0757OCCUPANCY TYPE: BCONSTRUCTION TYPE: UNKNOWNFIRE SPRINKLERED: YESHIGH RISE: NOSTORIES: 2BUILDING INFORMATIONDRAWING INDEXACPAPSDCFRExteriorACCESS CONTROL PANELLENELLNL-2220CONVERGINTACCESS CONTROL POWER SUPPLYCONVERGINTCONVERGINTCONVERGINTCONVERGINTCONVERGINTOTHERSDOOR CONTACTCONVERGINTDOOR RELEASE BUTTONCONVERGINTINTERIOR CAMERACONVERGINTEXTERIOR CAMERACONVERGINTFIRE ALARM RELAYOTHERSLENELLNL-1320-S3LENELLNL-1100-S3ALTRONIXAL1012ULXBHID920PTNNEK00000HID900PTNNEK00000SCHLAGEL9092TEU 07A RXVON DUPRINRX-QEL-98-NLMAGNASPHEREMSS-20CLALARM CONTROLSAC-RP100302AXISP3225-LV MK IIAXISP3225-LVE MK IICRCARD READER - RP40SEC-01COVER SHEETFL-011ST FLOOR PLAN SECURITY LAYOUTFL-022ND FLOOR PLAN SECURITY LAYOUTOL-01ACCESS ONE-LINE DIAGRAMOL-02VIDEO ONE-LINE DIAGRAMDE-01DOOR ELEVATIONSWE-01WALL ELEVATIONSPE-01PANEL ELEVATIONSCE-01CAMERA ELEVATIONS2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL FIRE CODE2017 NATIONAL ELECTRIC CODEAPPLICABLE CODESSCOPE OF WORKDUAL READER INTERFACE MODULEINPUT CONTROL MODULECRMCARD READER - RP10 (MULLION)DRELELECTRIFIED LEVER SETCB1ELECTRIFIED CRASH BAROTHERSVON DUPRINLX-RX-QEL-98-NL-OPOTHERSCB2ELECTRIFIED CRASH BARACCESS CONTROL POWER SUPPLYCONVERGINTALTRONIXAL1024ULXB2360INTERIOR CAMERACONVERGINTAXISM3047-PPTPOWER TRANSFER HINGEOTHERSVON DUPRINEPT10Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLSEC-01COVER SHEETDoor Contacts to be supplied by McKinneyDoor & Hardware and Installed byConvergint 300251020SECURITY LAYOUT VIEWScale: 3/16" = 1'-0"NLOBBY101WOMEN102MEN103TRAININGROOM104ELEC.105APPARATUSBAY #1106APPARATUSBAY #2107APPARATUSBAY #3108APPARATUSBAY #4109APPARATUSBAY #5110APPARATUSBAY #6111DECON112READYROOM113MEDICALSTORAGE114FITNESS115STAIR302ELEVATOR301STAIR303303A303C112114115A115B101B113102103105STORAGE116116109110111108107106104B106A101A104AP3225-LVM3047-P360P3225-LVEEXTERIORP3225-LVP3225-LVP3225-LVEEXTERIORDCCB2CRDCELCRDCELCRDCELCRDCELCRDCCB1CRDE-012DE-014DE-016DE-012DE-015DE-013Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLFL-011ST FLOOR PLANSECURITY LAYOUTPlease confirm all camera locations are acceptable as shown. Please verify if any additional cameras are required by the owner, eitherinterior or exterior. c LAUNDRY222MECHANICAL223DECK233STAIR303CORRIDOR220BUNKRM232BUNKRM231BUNKRM230BUNKRM229STORAGE228CORRIDOR224SHOWER227PANTRY219SHOWER226SHOWER225UNIFORMLOCKERS221KITCHEN218I.T.211DAYROOM216TOILET208LIBRARY/REPORTS215CORRIDOR210DINING217FLEX206OFFICE205OFFICE204OFFICE203CORRIDOR207MECH/ELEC209CONFERENCE214OFFICE212STORAGE213CORRIDOR202WAITING201ELEVATOR301OPEN TOBELOWSTAIR302300251020SECURITY LAYOUT VIEWScale: 3/16" = 1'-0"NP3225-LVACPAPSDCELCRDCELCRMDRDR2012111DE-01DE-012Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLFL-022ND FLOOR PLANSECURITY LAYOUT ACCESS CONTROL SYSTEM ONE-LINE DIAGRAM1ST FLOORAPS2ND FLOOR I.T. ROOM 211ACCESSCONTROLPANELFIRE ALARMINTERFACE RELAYTIE INTOCOMPUTERNETWORK120VAC POWERPROVIDED BYOTHERSACCESSPOWERSUPPLYCABLE SCHEDULECOMBINATION CABLE- CARD READER CABLE- LOCK POWER CABLE W/ OPTIONAL INTEGRATED REX CABLE- DOOR CONTACT CABLE- REQUEST TO EXIT CABLEA- 22/6 TWISTED, SHIELDED, STRANDED- 18/4 TWISTED STRANDED- 22/2 TWISTED STRANDED- 22/4 TWISTED STRANDEDCARD READER CABLEB- 22/6 TWISTED, SHIELDED, STRANDED PLENUMCABLE FUNCTIONWIRECABLE TYPENO.LOCK POWER CABLE W/ OPTIONAL INTEGRATED REX CABLEC- 18/4 TWISTED STRANDED PLENUMPASSIVE INFRARED REQUEST TO EXIT CABLED- 22/4 TWISTED STRANDED PLENUMDOOR CONTACT CABLEE- 22/2 TWISTED STRANDED PLENUMFEMERGENCY EXIT BUTTON CABLEG- 22/2 TWISTED STRANDED PLENUMA.1A.2A.3A.4KEY SWITCH CABLE- 18/2 TWISTED STRANDED PLENUM- PLENUMCAMERA CABLEH- CAT 6J485 BUS COMMUNICATION CABLE- 18/4 TWISTED STRANDED PLENUMOUTSIDEDIAMETER.415" NOM.163" NOM.184" NOM.150" NOM.126" NOM.158" NOM.126" NOM.175" NOM.184" NOMACPFRAA211A.1A.3A.2CRPTDCEL201A.1A.3A.2CRMPTDCELAA,C101A101BAA104A104B2ND FLOORAA114A.1A.3A.2CRPTDCEL303CA.1A.3A.2CRPTDCCB2A.1A.3A.2CRPTDCCB1A.1A.3A.2CRPTDCELA.1A.3A.2CRPTDCELA.1A.3A.2CRPTDCELDRDRGG220 CORRIDOR217 DININGCentennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLOL-01ACCESS ONE-LINEDIAGRAM PoESWITCHPoE211NW APPARATUSP3225-LVEHTRAINING 104P3225-LVHM. STORAGEM3047-PHI.T. ROOMNE APPARATUSP3225-LVEHSTAIR 303P3225-LVHLOBBY 101P3225-LVHIT RM. 211P3225-LVHVIDEO SYSTEM ONE-LINE DIAGRAM1ST FLOOR2ND FLOORCABLE SCHEDULECOMBINATION CABLE- CARD READER CABLE- LOCK POWER CABLE W/ OPTIONAL INTEGRATED REX CABLE- DOOR CONTACT CABLE- REQUEST TO EXIT CABLEA- 22/6 TWISTED, SHIELDED, STRANDED- 18/4 TWISTED STRANDED- 22/2 TWISTED STRANDED- 22/4 TWISTED STRANDEDCARD READER CABLEB- 22/6 TWISTED, SHIELDED, STRANDED PLENUMCABLE FUNCTIONWIRECABLE TYPENO.LOCK POWER CABLE W/ OPTIONAL INTEGRATED REX CABLEC- 18/4 TWISTED STRANDED PLENUMPASSIVE INFRARED REQUEST TO EXIT CABLED- 22/4 TWISTED STRANDED PLENUMDOOR CONTACT CABLEE- 22/2 TWISTED STRANDED PLENUMFEMERGENCY EXIT BUTTON CABLEG- 22/2 TWISTED STRANDED PLENUMA.1A.2A.3A.4KEY SWITCH CABLE- 18/2 TWISTED STRANDED PLENUM- PLENUMCAMERA CABLEH- CAT 6J485 BUS COMMUNICATION CABLE- 18/4 TWISTED STRANDED PLENUMOUTSIDEDIAMETER.415" NOM.163" NOM.184" NOM.150" NOM.126" NOM.158" NOM.126" NOM.175" NOM.184" NOM360Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLOL-02VIDEO ONE-LINEDIAGRAM SCALE: NONE1DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED LEVER SET TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED LEVER SET TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES. TURN LEVER TO EXIT.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED LEVER SET(PUSH SIDE)CARD READER(PUSH SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED LEVER SETWITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(RH)21142" AFF(RH)RIGHT HANDDCELCR SCALE: NONE2DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED LEVER SET TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED LEVER SET TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED LEVER SET(PULL SIDE)CARD READER(PULL SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED LEVER SETWITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLY1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(RHR)101B104B20142" AFFDCELCR (RHR)RIGHT HAND REVERSE12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLYSCALE: NONE3DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED CRASH BAR TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED CRASH BAR TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED CRASH BARW/REX (PUSH SIDE)CARD READER(PULL SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED CRASHBAR WITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLY1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(LHR)303C42" AFFDCCBCR (LHR)LEFT HAND REVERSESCALE: NONE4DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED CRASH BAR TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED CRASH BAR TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED CRASH BARW/REX (PUSH SIDE)CARD READER(PULL SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED CRASHBAR WITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLY1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(RHR)101A42" AFFDCCBCR (RHR)RIGHT HAND REVERSESCALE: NONE5DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED LEVER SET TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED LEVER SET TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES. TURN LEVER TO EXIT.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED LEVER SET(PUSH SIDE)CARD READER(PUSH SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED LEVER SETWITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(LH)11442" AFF(LH)LEFT HANDDCELCR 12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLYSCALE: NONE6DOOR WILL BE LOCKED AT ALL TIMES. THE DOOR WILL HAVE A DOOR CONTACT AND REX. THE DOORCONTACT IS FOR DOOR POSITION STATUS ONLY. REX IS TO SHUNT THE DOOR CONTACT.INGRESS: PASSING A CARD VALIDATED FOR ENTRY OVER THE CARD READER WILL ACTIVATE THE DOOR RELAYON THE CONTROL BOARD DE-ENERGIZING THE ELECTRIFIED LEVER SET TO UNLOCK THE DOOR ALLOWINGPERSONNEL TO ENTER THE DOOR.AFTER A PROGRAMMABLE TIME PERIOD THE DOOR RELAY ON THE CONTROL BOARD WILL DE-ACTIVATECAUSING THE ELECTRIFIED LEVER SET TO RELOCK, SECURING THE DOOR FROM THE ENTRANCE SIDE.EGRESS: FREE MECHANICAL EGRESS WILL BE MAINTAINED AT ALL TIMES. TURN LEVER TO EXIT.AN ACCESS CONTROL CARD WILL BE LOCATED IN THE KNOX BOX FOR EMERGENCY PERSONNEL TO HAVEACCESS TO ALL ACCESS CONTROLLED DOORS.NOTE:1. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTERHEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR.2. ALL CONDUIT AND WIRING BY ELECTRICAL CONTRACTOR.3. ADJUST DEVICE ROUGH-IN FOR APPROPRIATE DOOR SWINGFAIL SECUREDOOR CONTACTSELECTRIC HINGE ORPOWER TRANSFERELECTRIFIED LEVER SET(PULL SIDE)CARD READER(PULL SIDE)SINGLE GANG BOXSINGLE DOOR WITH READER, ELECTRIFIED LEVER SETWITH BUILT-IN REX, POWER TRANSFER HINGE,CONTACTS1/2" CONDUIT(STUBBED BEHIND DRYWALL)CEILING LINEAPPLICABLE DOORS:(LHR)104A42" AFF(LHR)LEFT HANDDCELCR 12" X 12"J-BOXLOCATED AT CLOSESTCONVENIENT LOCATIONABOVE CEILING1' CONDUIT TO ACCESSCONTROL PANEL ANDPOWER SUPPLYCentennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLDE-01DOOR ELEVATIONS 3/4" FIRE-RATEDPLYWOOD BACKBOARD6.5ACCESS CONTROLENCLOSURE(27.25X21.5X6.5)96.0027.25SIDE ELEVATIONFRONT ELEVATIONACCESS CONTROL ENCLOSURETROVE2M23/4" FIRE-RATE PLYWOODBACKBOARDCEILING LINEFLOOR LINECEILING LINEFLOOR LINE96.0027.2521.56.006X6X21.5 WIREWAY2" CONDUIT (TYP)6.006X6X21.5 WIREWAY2" CONDUIT (TYP.)FIRE RELAY (BY OTHERS)27.25"x21.5"x6.5"ACCESS CONTROLPANEL W/ POWERSUPPLY1ACP/APSFRWALL ELEVATION - I.T. ROOM 211Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLWE-01WALL ELEVATIONS FIRE RELAY (BY OTHERS)ACCESS CONTROL ENCLOSURE(TROVE2M2 - 27.25"X21.5"X6.5")TM2 BACKPLANE(25.375"X19.375")TMV2 DOOR BACKPLANE(23.75"X18.125")PD8 ACM8 N P SPD8 FUSED POWER OUTPUTS COMMON POWER OUTPUTSMAIN FUSENINPUTBROOKLYN,NY 11220PON OFFALTRONIX CORP.MADE IN USA12345678SW8SW7SW6SW5SW4SW3SW2SW1+ BAT -AL1012ULXBL G NBAT FAIL NC C NO NC C NO AC FAILACDC+ DC -+BAT- -DC+L G NAC NO C NC NO C NC BAT15A 250V10A 250VAL1024ULXBACDCAL1024ULXB AL1012ULXB IN1IN2IN3IN4TB1TB2INPUTSTB3IN5IN6TB4IN7IN8TB5TMPGNDPFLGNDAB12345678PFLR1R2TMPJ7J8 J9J10J14 J13U1S112345678 READER 2 VOLEDBZRCLKDATGNDD1D0VOLEDBZRCLKGNDD1D0DAT READER 1 TB8TB9NC NO C NC RLY 1 CNO RLY 2RLY 4 RLY 3 NO CNONCC NC RLY 6 RLY 5 NO CNONCC NC TB10TB11TB12J12K1K2K3K4K5K612VPTJ2J3J152 W 4WRS-485TR-R+R-GNDTR+TB6J5J6TB7VINGND J11J5, J6TERMINATORK1 K2 K3 K4 K5 K6 J4J3123TMPFLTR1R2+1324J8RESET S2BT13V BR/CR2330J15V3.3V2341S1VBATIN1K1K2K3K4K2K1K3K4IN2IN3IN4IN5IN6IN7IN88VJ6J2 J5J7PASS12V GNDDATD0TB8READER 1BZRVOGNDFLTGNDTMPGND VINTB1LEDD1CLKREADER 2D1LEDVOBZRGNDCLKD0DATTB9NOOUT 1 CNCNOOUT 2 CNCNCOUT 4 CNCNONOOUT 3 C TB10TB11 RXDCTSGNDRTSTXDTB2TB3 TR+GNDTR-IN1IN2IN3IN4IN5IN6IN7IN8TB4TB5TB6TB7-S1112435129768131410111516TB10 TR+GNDR+4WR-2WTR-RS-485GNDVINGNDBACTGNDTB9TB11 J2 J1J1, J2RS-485TERMNCCNONCCNOOUT 8OUT 7TB4 K8 NOCNCNOCNCOUT 6OUT 5NOCNCNOCNCOUT 4OUT 3NOCNCNOCNCOUT 2OUT 1TB3K7 TB2 TB1 2W4WJ3U1J6J5J7J8J4ABCTBA2345678K2K4K3K1K9K11K12K10K5K13K14K15K16 TB5TB6TB7TB8 NOCNCNOCNCOUT 9OUT 10CNONCCNONCOUT 11OUT 12NCCOUT 13NONCOUT 14NOCOUT 16NOCOUT 115NCCNONCK6IN1IN2IN3IN4TB1TB2INPUTSTB3IN5IN6TB4IN7IN8TB5TMPGNDPFLGNDAB12345678PFLR1R2TMPJ7J8 J9J10J14 J13U1S112345678 READER 2 VOLEDBZRCLKDATGNDD1D0VOLEDBZRCLKGNDD1D0DAT READER 1 TB8TB9NC NO C NC RLY 1 CNO RLY 2RLY 4 RLY 3 NO CNONCC NC RLY 6 RLY 5 NO CNONCC NC TB10TB11TB12J12K1K2K3K4K5K612VPTJ2J3J152 W 4WRS-485TR-R+R-GNDTR+TB6J5J6TB7VINGND J11J5, J6TERMINATORK1 K2 K3 K4 K5 K6IN1IN2IN3IN4TB1TB2INPUTSTB3IN5IN6TB4IN7IN8TB5TMPGNDPFLGNDAB12345678PFLR1 R2TMPJ7J8 J9J10J14 J13U1S112345678 READER 2 VOLEDBZRCLKDATGNDD1D0VOLEDBZRCLKGNDD1D0DAT READER 1 TB8TB9NC NO C NC RLY 1 CNO RLY 2RLY 4 RLY 3 NO CNONCC NC RLY 6 RLY 5 NO CNONCC NC TB10TB11TB12J12K1K2K3K4K5K612VPTJ2J3J152 W 4WRS-485TR-R+R-GNDTR+TB6J5J6TB7VINGND J11J5, J6TERMINATORK1 K2 K3 K4 K5 K6 LNL-1320 #2 LNL-2220 #1 LNL-1320 #3 LNL-1100 #1 LNL-1320 #1 FRPANEL ELEVATION - I.T. ROOM 211Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLPE-01PANEL ELEVATIONS Axis P3225-LV-MKIIInterior Dome cameraAxis Camera Back BoxSurface 1.5" NPT Conduit to IDFRoom 211 (If hard Lid Ceiling)Note: Network cable provided by Convergint.Network cable from Network switch to camera ranby others.Axis M3047-P Interior360 Dome cameraAxis T94B05L CameraBack BoxNote: Network cable provided by Convergint.Network cable from Network switch to camera ranby others.Axis P3225-LV-MKIIInterior Dome cameraAxis T94K02L CameraBack BoxNote: Network cable provided by Convergint.Network cable from Network switch to camera ranby others.Axis P3225-LV-MKIIInterior Dome cameraSurface 1.5" NPT Conduitto IDF Room 211Note: Network cable provided by Convergint. Networkcable from Network switch to camera ran by others.Centennial, Colorado 80112Phone: 303-932-0757 Fax: 303-932-1333This document and the information/depictions contained/shown is theexclusive property of Convergint Technologies LLC and shall be handled asproprietary and confidential information and must be returned uponrequest. This document cannot be reproduced by any means without thewritten authorization of Convergint Technologies LLC.R7330 S. Alton Way Ste. 12KPROJECT ENGINEER:DRAWING:PROJECT MANAGER:JOB NUMBER:SCALE:DATE:DRAWN BY:Converg ntT E C H N O L O G E SASPEN AMBULANCE DISTRICT FACILITY 401 CASTLE CREEK ROAD ASPEN, CO 81611APPROVEDREVDESCRIPTIONDATE PGPGES350SNJ0002AS-SHOWN1/22/2019ACCESS CONTROLCE-01CAMERA ELEVATIONS1M3047-P2P3225-LV MKII3P3225-LV MKII4P3225-LVE MKII UNITED STATES • CANADA • ASIA PACIFIC • EUROPE 7330 S Alton Way 12k, Centennial, CO 80112 Phone: 303-932-0757 Fax: 303-932-1333 Aspen Ambulance District Facility Access Control Product Data Submittals Submittal Date: January 29, 2019 By: Patrick Gallegos Convergint Technologies LLC Project Manager: Ed Stephens Convergint Project#: 350FNJ0002 Manufacturer Part #Description Page Number Lenel LNL-2220 Intelligent Dual Reader Controller 3 Lenel LNL-1320-S3 Dual Reader Interface Module 5 Lenel LNL-1100-S3 Input Control Module 7 Altronix ALT-TROVE2M2 Trove2 w/Mercury Backplane 9 Altronix AL1012ULXB 12VDC, 10Amp Board 13 Altronix AL1024ULXB2 10A Access 8A Fire P/S Board 15 Altronix ACM8CB 8 Channel Controller w/BKRS 17 Altronix PDS8CB 8 PTC, 2 Input Pwr Dist Mod 19 HID 920PTNNEK00000 RP40 Card Reader 21 HID 900PTNNEK00000 RP10 Card Reader 21 Magnasphere MSS-20CL Recessed Door Contact 23 Alarm Controls RP-100302 Door Release Button 26 Axis M3047-P 360 6MP Mini Dome Camera 27 Axis P3225-LV MKII Interior 1080p Fixed Dome Camera 29 Axis P3225-LVE MKII Exterior 1080p Fixed Dome Camera 32 Lenel SW-LNR-CH1 Lenel NVR 7.1 Software 35 Axis Lenel Lenel Alarm Controls Altronix Magnasphere HID Convergint to confirm that the submitted HID card readers will work with the current Aspen Valley Hospital cards as well as Pitkin County cards. Intelligent Dual Reader Controller LNL-2220 Overview The LNL-2220 Intelligent Dual Reader Controller (IDRC) by Lenel provides a single board solution for interfacing one or two doors to an OnGuard® system. In addition, other I/O and reader interface modules can be added on the LNL-2220’s downstream port to expand its capabilities. The LNL-2220 revolutionizes access control system architecture by allowing Ethernet connection directly from an entry location to the OnGuard server, while still providing the security, functionality, and modularity of Lenel’s proven hardware platform. The LNL-2220 is scalable for any access control application, from the most basic to the most sophisticated. In the event of communication loss, the LNL-2220 allows nearly all local functionality to continue unimpaired until the server connection is restored. Utilizing its native Ethernet communications and an advanced 32- bit processor, the LNL-2220 can communicate upstream to the host computer through its Ethernet port (with a throughput up to eight times greater than the fastest serial connections), or at up to 115.2 Kbps using RS-232 communication directly or through an external dial-up modem. The LNL-2220 can store up to 250,000 cardholders in non-volatile flash memory, and supports selective download for larger cardholder databases. The downstream RS-485 two-wire port can be used to connect up to 32 devices (maximum 64 doors). Two on-board reader ports support Data1/Data0, Clock/Data, Bioscrypt RS-485 readers and the bidirectional RS-485 Open Supervised Device Protocol (OSDP) communications. Each LNL-2220 supports up to eight different card formats. The LNL-2220 includes eight inputs that support normally open, normally closed, supervised, and unsupervised circuits. In addition, four output relays support fail-safe or fail-secure operation. FEATURES & FUNCTIONALITY Controller Functionality • On-board Ethernet 10/100Base-T port provides up to 8 times greater throughput than serial-to-Ethernet converters. DHCP and fixed IP addressing supported. • DNS device naming through DHCP extended commands • 6 MB of available on-board, non-volatile flash memory • Battery-backed, non-volatile storage of 50,000 events • Firmware stored in flash memory, background download of firmware updates supported • Supports up to 16 different formats (8 card formats and 8 asset formats) • Biometric template storage support for Schlage Recognition Systems®, Bioscrypt®, and Identix®. • Direct connection of Bioscrypt RS-485 devices • Enhanced anti-passback capabilities • Up to 32,000 access level permissions • 255 holidays with grouping, 255 timezones, each with 6 intervals • Elevator control support for up to 128 floors • Individual extended held open and strike times (ADA required) • Up to 9-digit user PIN codes • 20 status LEDs • 2 dedicated inputs for tamper and power failure status • 12 or 24 VDC input power • Advanced Encryption Standard (AES) 128-bit algorithm for communications Reader Interface Functionality • Supports Data1/Data0, Clock/Data and Lenel OSDP-compatible RS-485 readers and keypads • 4 Form-C relay outputs, 5 A at 30 VDC • Door contact supervision (open/closed) and REX push-button monitor for each door • Strike control and auxiliary output for each door • Bicolor reader status LED support plus beeper control, or 2-wire LED support • On-board regulator allows 12 VDC reader power from 24 VDC power source (866) 788-5095 Specifications subject to change without notice. © 2014 Lenel Systems International, Inc. All rights reserved. All other trademarks and copyrights are the property of their respective owners. LNL_TS_2220_063014 lenel.com Controller Features LNL-2220 6 MB On-board flash memory available for cardholder & asset database, 50,000 event battery backed RAM for event log Dial-Up Modem LNL-56KEXT 56 K external modem with cables LNL-DC336K 12 VDC-powered/33.6 K external modem Specifications Primary Power (DC or AC)* The LNL-2220 is for use in low voltage, power-limited, class 2 circuits only. DC input:12 or 24 VDC ± 15%. 500 mA maximum AC input:12 VAC ± 15%. 400 mA RMS Memory and Clock backup 3 V lithium, type BR2325, BR2330, CR2330 Communication Ports Primary (Ethernet) Port:10/100Base-T Ethernet high-speed port Alternate Upstream Port 1:RS-232 9600 to 115.2 Kbps async Downstream Port 2:RS-485 (2-wire) 9600 to 38.4 Kbps async Inputs Tamper and Power Fail Monitors:Unsupervised, dedicated Door position, REX, and AUX: 8, each programmable as normally open or normally closed, supervised or unsupervised circuits Outputs Relay outputs:4 Form-C 5 A at 30 VDC relay outputs: 2 strike, 2 auxiliary Reader Power DC output: 12 VDC, 125 mA regulated when 24 VDC powered, or 12 to 24 VDC 125 mA current limited Reader Port Compatibility Wiegand Data1/Data0, Magnetic Clock/Data, F/2F single-wire protocol, Bioscrypt RS-485, OSDP (Open Supervised Device Protocol RS-485) Environmental Temperature:Operating: 32° to 158° F (0° to +70° C) Storage: -67° to 185° F (-55° to +85° C) Humidity:0 to 95% RHNC Mechanical Dimensions:6 x 5 x 1 in. (152 x 127 x 25 mm) Weight:8 oz. (230 g) nominal Approvals UL 294, CE-marked, RoHS compliant Supported Readers Schlage Wireless - WA 5296, WA 5696, WA 5694, WA 993, WRI, WPR Approvals:FCC Part 15, CE, RoHS, UL 294, UL 1076, ULC CSA-C22.2, CAN/ULC-S319-05, cUL/ ORD-C1076 LNL-1300 Single Reader Interface Module LNL-1100 Input Control Module Up to 16 Inputs per LNL-1100 Motion Sensor Alarm LNL-1200 Output Control Module Up to 16 Outputs per LNL-1200 RS-485 Multi-drop up to 4000 ft. ReaderReaderReader LNL-2220 Intelligent System Controller (ISC) Max 32 Devices TCP/IP NETWORKOnGuard Security Server Option 2.1 -OR- Reader Reader Option 2.2 Reader Reader LNL-1320 Dual Reader Interface Module Access Hardware LNL-1320 Series 3 Dual Reader Interface Module lenel.com/access-hardware Overview Lenel offers a Dual Reader Interface (DRI) module for access control solutions. Most access control card readers, keypads, or readers with keypads that use standard Wiegand Data1/ Data0 or Clock/Data communication are supported, as are those that support the bidirectional RS-485 Open Supervised Device Protocol (OSDP™). Lock, unlock, and facility code offline access modes are supported on all readers connected to the DRI. Each DRI supports up to 16 different card formats as well as issue codes for both magnetic and Wiegand card formats. The DRI provides a vital link between the Intelligent System Controller (ISC) and the card reader attached to the interface. As many as 32 DRI modules can be multidropped using RS- 485 2-wire or 4-wire communication up to 4,000 feet per port away from the ISC. Each DRI module is individually addressed for increased reporting capabilities with OnGuard® access control software applications. The DRI includes eight inputs that support normally open, normally closed, supervised, and non-supervised circuits. In addition, six output relays support fail-safe or fail-secure operation. Features & Functionality • 12 or 24 VDC power supply • Supports Data1/Data0, Clock/Data, Supervised and Unsupervised F2F and OSDP-compatible RS-485 readers and keypads • Supports Open Supervised Device Protocol (OSDP) readers, including biometric template transfer and Secure Channel encryption • Downloadable firmware • Six Form-C 5 A at 28 VDC relay outputs • Up to 16 different formats • Issue code support for magnetic and Wiegand formats • Door contact supervision (open/closed) • REX push-button monitor • Strike control output • Bicolor reader status LED support and 2-wire LED support • Beeper control • Dedicated tamper and power failure circuits • Support for offline reader access mode • On-board jumpers for termination • On-board regulator allows 12 VDC reader support from 24 VDC power source • DIP switch-selectable addressing • Advanced Encryption Standard (AES) 128-bit or 256-bit encryption supported, depending on ISC and OnGuard version • Supports Schlage® Handkey® template download • Compatible with current and previous versions of OnGuard Extended Functionality • Connect FIPS-201 readers for embedded authentication (when used with LNL-4420 and appropriate HID® and OnGuard software and licenses) lenel.com (866) 788-5095 Specifications subject to change without notice. ©2017 United Technologies Corporation. All rights reserved. All trademarks are the property of their respective owners. Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 2017/12 (GSP-2463) LNL-1320 Series 3 Specifications Primary Power 12 to 24Vdc ±10%, 550mA maximum (plus reader current) 12Vdc @ 550mA (plus reader current) maximum, 22.5 BTUs 24Vdc @ 330mA (plus reader current) maximum, 27.0 BTUs Outputs 6 outputs, Form-C contacts: Normally Open (NO) Contact: 5A @ 30 Vdc, Normally Closed (NC) Contact: 3A @ 30 Vdc Inputs 8 unsupervised/supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt 2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring Reader Interface Reader power: 12Vdc ±10% regulated, 300mA maximum each reader (jumper selectable and input voltage (VIN) must be 20Vdc minimum) or 12 to 24Vdc ±10% (input voltage passed through) 300mA maximum each reader Reader Port Compatibility Wiegand Data 1/Data 0 Magnetic Clock/Data Supervised and Unsupervised F2F Open Supervised Device Protocol Mechanical Dimension: 6” (152mm)W x 8” (203mm)L x 1” (25mm)H Weight: 11 oz. (312g) nominal Environmental Temperature Operating: 32°F to 158°F (0°C to +70°C) Storage: -67°F to 185°F (-55°C to +85°C) Humidity 5% to 95% RHNC Compliance Approvals FCC Part 15, CE, RoHS, UL 294, UL 1076, ULC CSA-C22.2, CAN/ULC-S319-05, cUL/ORD-C1076 Intelligent System Controller (ISC) Capacity varies per ISC model* LNL-1320 Dual Reader Interface Module LNL-1300 Single Reader Interface Module LNL-1100 Input Control Module Up to 16 Inputs per LNL-1100 Motion Sensor Alarm LNL-1200 Output Control Module Up to 16 Outputs per LNL-1200 RS-485 Multi-drop up to 4000 ft. Option 1TCP/IP NETWORKReader Reader Reader Option 2 OnGuard® Security Server -OR- * See ISC datasheets for specic capacities. Power Supplies & Enclosures LNL-AL400ULX UL Listed 4A, 110VAC Power Supply – 12VDC 4A output, 115VAC input, continuous supply cur- rent with enclosure (15.5” x 12.5” x 4.5”), lock, tamper switch, UPS capable (Battery Optional) UL & CUL Approved LNL-AL600ULX-4CB6 UL Listed Power Supply – 12VDC 6A output, 115VAC (1.6 amps) input, continuous supply current with enclosure (24” x 18” x 4.5”), lock, tamper switch, power distribution module, UPS capable (Battery Optional) UL & CUL Approved ABT-12 Battery Kit - 12VDC, 12 AH battery (PS-12120) System Diagram Access Hardware LNL-1100 Series 3 Input Control Module lenel.com/access-hardware Overview Series 3 Lenel® Input Control Module (ICM) provides the access control system with high-speed acknowledgement of critical alarm points in monitored areas. The ICM communicates directly with the Intelligent System Controller (ISC) by either 2-wire or 4-wire RS-485 communication. The ICM has 16 configurable input control points and 2 output control relays. It supports normally open, normally closed, supervised and non- supervised circuits. The input circuits are scanned using an analog-to-digital converter. The digitized input status signal is software- monitored and controlled, so that each input point can be programmed as a supervised or non-supervised alarm point. The output relays can also be configured for fail-safe or fail- secure operation. Each realy supports the “On,” “Off,” and “Pulse” Lenel OnGuard® software commands. Features & Functionality • Grade B, A, and AA line supervision • 12 or 24 VDC input power • 16 programmable supervised or non-supervised contacts • 2 Form-C 5 A, 28 VDC contacts for load switching • 2 dedicated inputs for tamper and power failure status • On-board termination jumpers • DIP switch-selectable addressing • Elevator control, support for 128 floors • Status LED for host communication and heartbeat • Variable resistor values for line supervision • Downloadable firmware • Advanced Encryption Standard (AES) 128-bit or 256-bit encryption supported, depending on ISC and OnGuard version • Suitable as replacement for Series 1 and Series 2 boards lenel.com (866) 788-5095 Specifications subject to change without notice. ©2017 United Technologies Corporation. All rights reserved. All trademarks are the property of their respective owners. Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 2017/12 (GSP-2463) LNL-1100 Series 3 Specifications Primary Power 12 to 24Vdc ±10%, 350mA maximum 12Vdc @ 300mA nominal, 12.27 BTUs 24Vdc @ 220mA nominal, 18.00 BTUs Outputs 2 outputs, Form-C, 5A @ 28Vdc, resistive Inputs 16 unsupervised/supervised, standard EOL: 1K/1K ohm, 1%, 1/4 watt 2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring Mechanical Dimension: 6” (152mm)W x 8” (203mm)L x 1” (25.4mm)H Weight: 9 oz. (250g) nominal Environmental Temperature Operating: 32°F to 158°F (0°C to +70°C) Storage: -67°F to 185°F (-55°C to +85°C) Humidity 0% to 95% RHNC Compliance Approvals FCC Part 15, CE, RoHS, UL 294, UL 1076, ULC CSA-C22.2, CAN/ULC-S319-05, cUL/ORD-C1076 Power Supplies & Enclosures LNL-AL400ULX UL Listed 4A, 110VAC Power Supply – 12VDC 4A output, 115VAC input, continuous supply current with enclosure (15.5” x 12.5” x 4.5”), lock, tamper switch, UPS capable (Battery Optional) UL & CUL Approved LNL-AL600ULX-4CB6 UL Listed Power Supply – 12VDC 6A output, 115VAC (1.6 amps) input, continuous supply current with enclosure (24” x 18” x 4.5”), lock, tamper switch, power distribution module, UPS capable (Battery Optional) UL & CUL Approved ABT-12 Battery Kit - 12VDC, 12 AH battery (PS-12120) System Diagram Intelligent System Controller (ISC) Capacity varies per ISC model* LNL-1320 Dual Reader Interface Module LNL-1300 Single Reader Interface Module LNL-1100 Input Control Module Up to 16 Inputs per LNL-1100 Motion Sensor Alarm LNL-1200 Output Control Module Up to 16 Outputs per LNL-1200 RS-485 Multi-drop up to 4000 ft. Option 1TCP/IP NETWORKReader Reader Reader Option 2 OnGuard® Security Server -OR- * See ISC datasheets for specic capacities. Description Altronix Trove™ enclosures and backplanes let you easily integrate Altronix power with Mercury access controllers and accessories. Trove simplifies board layout and wire management, reduces installation time and labor costs. Trove2M2 Kit / TM2 Backplane Access & Power Integration Solution Rev. TROVE2M2 / TM2 - 01152019 Trove2 Enclosure + TM2 Backplane Features - Accommodates the following Mercury controllers with or without Altronix power/accessories: - Mercury: EP1502, MR52, MR16IN, MR16OUT, EP2500, MUX8, MR51e, EP1501, MR50, and Genetec Synergis Cloud Link - Altronix Power Supplies - Altronix Sub-Assemblies - Backplane features: - Simplifies board layout and wire management - 16 AWG galvanized steel Dimensions: 25.375”H x 19.375”W x 0.3125”D (644.5mm x 492.1mm x 8mm) Weights: Product - 8.0 lbs. (3.63 kg) Shipping - 10.0 lbs. (4.53 kg) TM2 Backplane Features All registered trademarks are property of their respective owners. * Boards not included Trove2M2 - Accommodates the following Mercury controllers: - Mercury: EP1502, MR52, MR16IN, MR16OUT, EP2500, MUX8, and Genetec Synergis Cloud Link - Door Backplane features: - Simplifies board layout and wire management - 16 AWG galvanized steel Dimensions: 23.75”H x 18.125”W x 0.3125”D (603.25mm x 460.375mm x 7.94mm) Weights: Product - 8.0 lbs. (3.63 kg) Shipping - 9.0 lbs. (4.08 kg) TMV2 Door Backplane Features - Accommodates the following Mercury controllers with or without Altronix power/accessories: - Mercury: EP1502, MR52, MR16IN, MR16OUT, EP2500, MUX8, MR51e, EP1501, MR50, and Genetec Synergis Cloud Link - Altronix Power Supplies - Altronix Sub-Assemblies - Includes Altronix Trove2 Enclosure and one (1) removable TM2 backplane Agency Listings UL: UL294 - Access Control System. cUL: CAN/ULC - s319-05 - Electronic Access Control Systems. CE European Conformity. Features - Simplifies board layout and wire management - Convenient knockout configuration: - Single 2” diameter knockout located top center of enclosure - Sixteen (16) double knockouts (1” and 0.75”) - Accommodates up to four (4) 12VDC/7AH batteries - 16 AWG powder coated steel - Includes cam lock, tamper switch and mounting hardware Dimensions (H x W x D): 27.25” x 21.5” x 6.5” (692.15mm x 546.1mm x 165.1mm) Weights: Product - 37.1 lbs. (16.83 kg) Shipping - 40.85 lbs. (18.53 kg) Altronix Power Supply Altronix Power Supply Altronix Power Supply or Sub-Assembly Altronix Power Supply or Sub-Assembly Mercury EP1501, MR51e, MR50 Mercury EP1501, MR51e Mercury EP1501, MR51e Mercury EP1501, MR51e Mercury EP1501, MR51e Mercury MR50 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Genetec Synergis Cloud Link Genetec Synergis Cloud Link Genetec Synergis Cloud Link Genetec Synergis Cloud Link Trove2M2 Interior Backplane - Optional Mounting Configurations TMV2 - Optional Door Backplane Configurations: Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP2500, MUX8 Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT Mercury EP1502, MR52, MR16IN, MR16OUT HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 HID VertX® V100, V200 V300, V1000 and V2000 Genetec Synergis Cloud Link Genetec Synergis Cloud Link Genetec Synergis Cloud Link Trove2M2 Access & Power Integration Solution Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com G 1.25”(31.75mm) 1.25”(31.75mm) 6.25”(158.75mm) 6.25”(158.75mm) 6.75”(171.45mm) 8.25”(209.54mm) 8.00”(203.2mm) 1.5”(38.1mm) 1.25”(31.75mm) 0.85”(21.59mm) 0.85”(21.59mm) 1.00”(25.4mm) 2.00”(50.8mm) 1.25”(31.75mm) 2.00”(50.8mm)2.00”(50.8mm)5.25”(133.35mm)5.25”(133.35mm)7.00”(177.79mm) 2.00”(50.8mm) 2.00”(50.8mm) 27.00”(685.8mm) 3.50”(88.9mm) 0.5625”(14.29mm) 2.415”(61.34mm) 0.685”(17.399mm) 1.77”(44.96mm) 3.50”(88.9mm) 21.50”(546.1mm) 19.80”(502.92mm) 5.25”(133.35mm)5.25”(133.35mm) 0.885” (22.479mm)1.125” (28.32mm)Knockouts Description Altronix AL1012ULXB UL Listed Sub-Assembly power supply/charger converts a 115VAC, 60Hz input into a single 12VDC non power-limited output. It also offers a suite of features that includes AC fail supervision, battery presence, and low battery supervision. AL1012ULXB Power Supply/Charger Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com Rev. AL1012ULXB-01092017 Input Voltage 115VAC 60Hz, 2.6A max. Fusing 5A / 250V. Output Voltage 12VDC. Current 10A continuos supply current. Other Short circuit and thermal overload protection. Filtered and regulated. Back-up Battery (not included) Type Sealed lead acid or gel type. Fuse Rating 15A @ 32V. Failover Upon AC loss, instantaneous. Supervision AC Failure Form “C” contacts. Battery Form “C” contacts. Indicators (LED) Input 115VAC is present. DC Output Powered. Battery Discharged or not connected. Agency Listings UL: Access Control UL294 cUL: Signal Equipment CSA C22.2 No.205-M1983 Physical and Environmental Dimensions (L x W x H) 7.25” x 4.5” x 1.75” (184.2mm x 114.3mm x 44.5mm). Product Weight 0.75 lbs. (0.34 kg). Shipping Weight 0.9 lbs. (0.41 kg). Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70ºC (-4ºF to 158ºF). Relative Humidity 85% +/-5%. BTU/Hr (approx.): 61 BTU/Hr. Specifications AL1012ULXB AL1012ULXB Power Supply/Charger Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com Board Dimensions (L x W x H) and Drawing 7.25” x 4.5” x 1.75” (184.2mm x 114.3mm x 44.5mm) 0.36”(9.1mm) 6.7”(170.2mm) 3.7”(94mm)4.5”(114.3mm) 0.185”(4.7mm) 7.25”(184.2mm) Ø0.156”(3.9mm) Description Altronix AL1024ULXB2 UL Listed Sub-Assembly power supply/charger converts 115VAC, 60Hz input into a single 24VDC non power-limited output. It also offers a suite of features that includes AC fail supervision, battery presence, and low battery supervision. AL1024ULXB2 Power Supply/Charger Rev. AL1024ULXB2-10262017 Input Voltage 115VAC 60Hz, 4.2A max. Fusing 5A / 250V. Output Voltage 24VDC (UL 1481). Current 8A continuous supply current with 10A supply current during alarm (UL 1481). 24VDC @ 10A (UL 294). Other Short circuit and thermal overload protection. Filtered and regulated. Back-up Battery (not included) Type Sealed lead acid or gel type. Fuse Rating 15A @ 32V. Failover Upon AC loss, instantaneous. Supervision AC Failure Form “C” contacts. Battery Form “C” contacts. Indicators (LED) Input 115VAC is present. DC Output Powered. Battery Discharged or not connected. Agency Listings UL: Access Control UL 294 Burglar Alarm UL 603 Fire Alarm UL 1481 cUL: Signal Equipment CSA C22.2 No.205-M1983 Physical and Environmental Dimensions (L x W x H) 8.4” x 4.5” x 1.9” (213.4mm x 114.4mm x 49.7mm). Product Weight 1.15 lbs. (0.52 kg). Shipping Weight 1.45 lbs. (0.0.66 kg). Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70ºC (-4ºF to 158ºF). Relative Humidity 85% +/-5%. BTU/Hr (approx.): 123 BTU/Hr. Specifications AL1024ULXB2 AL1024ULXB2 Power Supply/Charger Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com Board Dimensions (L x W x H) and Drawing 8.4” x 4.5” x 1.9” (213.4mm x 114.4mm x 49.7mm) Ø0.156”(3.9mm) 3.7”(94mm) 0.5”(12.7mm) 6.7”(170.2mm)0.75”(19.0mm) 4.5”(114.3mm) 8.4”(213.4mm) Description Altronix ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) indepen- dently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2.5A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. ACM8CB Multi-Output Access Power Controller Rev. ACM8CB-02222018 Input Voltage: 12 to 24 VAC or VDC operation (setting not required), 0.6A @ 12V, 0.3A @ 24V current consumption with all relays energized. Main fuse is rated at 10A. Trigger Inputs: Eight (8) Access Control System trigger inputs: a) Eight (8) normally open (NO) inputs. b) Eight (8) open collector sink inputs. c) Any combination of the above. Input Options: a) One (1) common power input (board and lock power). b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power). Outputs Eight (8) independently controlled Class 2 Rated PTC protected power-limited auto-resettable 2.5A outputs: a) Eight (8) Fail-Safe and/or Fail-Secure power outputs. Eight (8) auxiliary power outputs (unswitched). Output ratings: Output PTCs are rated 2.5A each. Note: Total output current is determined by the power supply, not to exceed a maximum of 10A total. Indicators (LED) Red LEDs Outputs are triggered (relays energized). Green LED FACP disconnect is triggered. Agency Listings UL: UL294 Access Control System Units. cUL: CSA Standard C22.2 General Signaling Equipment. No.205-M1983. Physical and Environmental Dimensions (W x L x H) 8” x 4” x 0.75” (203.2mm x 114.3mm x 19.1mm). Product Weight 0.65 lbs. (0.29 kg). Shipping Weight 0.85 lbs. (0.39 kg). Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70º C (-4ºF to 158ºF). Relative Humidity 85% +/-5%. BTU/Hr (approx.): 4 BTU/Hr. Specifications ACM8CB 0.16" (4.1mm) 0.28"(7.1mm) 0.43" (10.9mm) 0.55" (14mm) 4.9" (124.5mm) 6.7" (170.2mm) 8.0" (203.2mm) 2.4" (61mm)3.7" (94mm)4.5" (114.3mm) Ø0.156" (3.9mm) ACM8CB Multi-Output Access Power Controller Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com Board Dimensions (L x W x H) and Drawing 8” x 4” x 0.75” (203.2mm x 114.3mm x 19.1mm) Description Altronix PDS8 and PDS8CB dual input power distribution modules are designed to steer the power from either two (2) low voltage AC or DC power sources. The two Inputs can be either, both DC (e.g. 12VDC and 24VDC) or both AC (e.g. 16VAC and 24VAC). That power is distributed over a total of eight (8) fuse or PTC protected out- puts. The spade connectors allow you to daisy chain multiple PDS8/PDS8CB modules. This feature allows you to distribute the power over more outputs for larger systems. PDS8 and PDS8CB Dual Input Power Distribution Modules Rev. PDS8/PDS8CB - 03162018 Input Voltage Range PDS8: 5VDC to 24VDC, up to 10A each or 16VAC to 28VAC, 60Hz, up to 10A each, 20A total input. PDS8CB: 5VDC to 24VDC up to 10A each or 16VAC to 28VAC, 60Hz, up to 10A each, 16A total input. Main Fuse Rating 10A. Outputs PDS8: Fuse protected outputs rated @ 3A per output, non power-limited. Total output 20A max. PDS8CB: PTC protected outputs rated @ 2A per output, Class 2 power-limited. Total output 16A max. Do not exceed the individual power supply ratings. Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings: PDS8: 4.8 - 24 VDC or 15.8 - 28 VAC. PDS8CB: 4.8 - 24 VDC or 15.6 - 28 VAC. Indicators (LED) DC Output Eight (8) individual output LEDs. Features Multiple units may be daisy-chained to accommodate larger systems. Agency Listings UL/cUL: UL 294 6th Edition: Access Control System Units. ULC-S319: Electronic Access Control Systems. Physical and Environmental Dimensions (L x W x H) 5.375” x 3” x 1” (136.5mm x 76.2mm x 25.4mm). Product Weight 0.4 lbs. (0.18 kg). Shipping Weight 0.5 lbs. (0.23 kg). Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70ºC (-4ºF to 158ºF). Relative Humidity 85% +/-5%. Specifications PDS8 PDS8 and PDS8CB Dual Input Power Distribution Modules Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com 2.375”60.3mm 4.875”123.8mm Ø 0.156”3.9mm 3.0”76.2 mm 5.375”136.5mm 0.25”6.4mm 8-pinconnector0.25”6.4mm Board Dimensions (L x W x H) and Drawing 5.375” x 3” x 1” (136.5mm x 76.2mm x 25.4mm) PDS8K1 and PDS8CBK1 Altronix offers PDS8(CB) kits which include a dual output Power Distribution Module and VR6 - Voltage Regulator, along with all necessary hardware. Altronix VR6 & PDS8 easily snap together to provide 5VDC or 12VDC and 24VDC simultaneously – individually selectable over each of the 8 outputs... all on one footprint! - VR6 reduces the cost of adding another power supply. - PDS8 is designed to piggyback onto the VR6 making an instant plug-in connection via common standoffs. - Stackable mounting configuration saves valuable enclosure space. PHYSICAL ACCESS CONTROL HID Mobile Access®iCLASS SE® & multiCLASS SE® Mobile Enabled Readers hidglobal.com MOBILE ENABLED ICLASS SE PLATFORM READERS THAT OFFER NEW WAYS TO OPEN DOORS ƒInnovative – Enables secure access with a mobile device by leveraging standard communications technologies that work with both iOS® and Android™ operating systems. ƒConvenient – Enhances the transactional experience by opening doors with a tap or “Twist and Go” gesture, merging security with convenience. ƒDynamic – Supports new Mobile IDs and existing card populations for seamless migration to a more secure standard. A UNIQUE USER EXPERIENCE HID Mobile Access® offers a patented gesture technology that allows door and gate access with a twist of the handset upon approaching an iCLASS SE® or multiCLASS SE® mobile-enabled reader. iCLASS SE® and multiCLASS SE® mobile-enabled readers are part of the HID Mobile Access® solution that offers a consistent user experience across different devices and operating systems, including iOS and Android. The readers can be configured to using a smartphone with a “tap” or utilizing HID Global’s patented “Twist and Go” gesture technology. Ideal for new and existing installations, the interoperable iCLASS SE and multiCLASS SE readers support a variety of industry-standard technologies, including iCLASS Seos®, standard iCLASS®, iCLASS SE, MIFARE®, MIFARE DESFire® and HID Prox. Simultaneous support of mobile device and existing card populations facilitates mixed population use and migration to a more secure standard. Advanced multi-layered security is provided via the iCLASS SE platform with its Secure Identity Object® (SIO®) data model. This additional layer of security ensures tamper-resistant protection of keys and cryptographic operations. The incorporation of Seos technology to manage identity data results in a dynamic and highly secure mobile solution. iCLASS SE® AND multiCLASS® SE MOBILE-ENABLED READERS FEATURES: ƒAdjustable read settings control overall power and read range of Mobile IDs, enabling flexibility for both close-proximity “tap” and long-range “Twist and Go” distances. ƒRead settings administered using mobile phone during installation. ƒDirectional antenna enables long- range reading distances of up to 6.6’ in correct orientation – in front of the reader and not behind it. SPECIFICATIONS An ASSA ABLOY Group brand © 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, HID Global, the HID Blue Brick logo, the Chain Design, HID Mobile Access, iCLASS SE, multiCLASS SE, MIFARE, DESfire, Seos, Prox, and Secure Identity Services are trademarks or registered trademarks of HID Global in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. 2016-03-21-hid-mobile-access-readers-nfc-ds-en PLT-02094 North America: +1 512 776 9000 Toll Free: 1 800 237 7769 Europe, Middle East, Africa: +44 1440 714 850 Asia Pacific: +852 3160 9800 Latin America: +52 55 5081 1670 hidglobal.com Model Name R10 RP10 R15 RP15 R40 RP40 RK40 RPK40 Typical Read Range* Both "Twist & Go" and "Tap" ranges are likely maximum distances based on recommended settings in a typical lab environment. Read ranges and behavior will vary by installation, due to a variety of factors. Reader-specific read range and power settings will contribute to adjusting behavior. Mobile IDs using Bluetooth & Seos® Twist and Go 6.6 ft (2 m)6.6 ft (2 m)6.6 ft (2 m)6.6 ft (2 m) Tap 5.9" (15 cm)5.9" (15 cm)5.9" (15 cm)5.9" (15 cm) Mounting Mini-Mullion Size; mount on door mullion or any flat surface Mullion Size; mount on door mullion or any flat surface Wall Switch Size; designed to mount to and cover single-gang switch boxes primarily used in the Americas and includes a slotted mounting plate for European and Asian back box spacing Wall Switch Size; designed to mount to and cover single- gang switch boxes primarily used in the Americas and includes a slotted mounting plate for European and Asian back box spacing Color Black or Gray Keypad No No No Yes (4x3) Dimensions 1.9” x 4.1” x 0.9” 4.8 cm x 10.3 cm x 2.3 cm 1.9” x 6.0” x 0.9” 4.8 cm x 15.3 cm x 2.3 cm 3.3” x 4.8” x 1.0” 8.4 cm x 12.2 cm x 2.4 cm 3.3” x 4.8” x 1.1” 8.5 cm x 12.2 cm x 2.8 cm Operating Voltage Range 5-16 VDC; Linear supply recommended Standby AVG Current 82 mA 97 mA 82 mA 97 mA 87 mA 107 mA 107 mA 117 mA PEAK Current 240 mA 240 mA 240 mA 240 mA 240 mA 240 mA 260 mA 260 mA Operating Temperature -13º to 150º F (-25º to 65º C) Storage Temperature -67º to 185º F (-55º to 85º C) Operating Humidity 5% to 95% relative humidity non-condensing Transmit Frequency 2.4GHZ, 13.56 MHz 2.4 GHz Credential Compatibility*Secure Identity Object (SIO) on Mobile IDs (Bluetooth Smart) 13.56 MHz Credential Compatibility Secure Identity Object (SIO) on iCLASS Seos, iCLASS SE, SIO-enabled MIFARE DESFire EV1 and SIO-enabled MIFARE Classicstandard iCLASS Access Control Application (standard iCLASS cards) ISO14443A (MIFARE) CSN, ISO14443B CSN, ISO15693 CSN Custom sectors on MIFARE, Custom app/file on DESFire EV1 (custom programming feature) Secure Identity Object (SIO) on NFC-enabled devices using Host-Based Card Emulation 125 kHz Credential Compatibility (multiCLASS only) HID Prox, AWID, EM4102 Cable Distance Optional OSDP with SCP over RS485 (4000 ft) Wiegand/Clock-and-Data Interface 500ft (150m) (22AWG) Use Shielded cable for best results Reader Personalization Mobile-enabled readers come fully personalized to read customer/site-specific Mobile IDs. Mobile-ready readers come fully prepared to read Mobile IDs but to do not include customer/site-specific personalization. Install Mobile-ready readers to prepare for Mobile IDs in the future. Panel Connection Pigtail or Terminal Strip Certifications Bluetooth SIG certification, UL-294/cUL (US & Canada), FCC certification (US), IC (Industry Canada), CE now including RoHS II, REACH Crypto Processor Hardware Common Criteria Rating EAL5+ Patents US7124943, US6058481, US6337619 Housing Material UL94 Polycarbonate Manufactured with % of recycled content (Pigtail) 10.5%11.0%10.5%10.9% Manufactured with % of recycled content (Terminal Strip) 10.5%11.0%11.0%12.3% UL Ref Number R10E RP10E R15E RP15E R40E RP40E RK40E RPK40E Warranty Limited Lifetime Mullion mounted card reader Wall mounted card reader Please confirm black is an acceptable color for all card readers MAGNASPHERE CORP. | 23777 Stone Ridge Dr., Suite 160, Waukesha, WI 53188 tel. 262.347.0711 | fax 262.347.0710 | www.MAGNASPHERE.com MSS Standard Series Product Sheet Security Contacts have been made with a decades-old technology called the Reed switch. Reed switches have three inherent weaknesses when used in security contacts. They are (1) Easily defeated with magnets, (2) Prone to permanent contact weld failure (from lightning and power surges), and (3) fragile (made mostly of glass, they are subject to damage even when packaged as security contacts). The MAGNASPHERE line of security sensors provides a solution to all of these issues. Utilizing the the patented, revolutionary MAGNASPHERE® BMS switch renders the MSS products virtually unbreakable, and highly resistant to permanent contact welding and outsider magnet defeat, allowing MAGNASPHERE to offer a lifetime replacement warranty. MSS contacts are available in both the traditional Closed Loop (contact closed when magnet is present) as well as the more Secure Open Loop (contact open when magnet is present) electrical configuration. This is the same configuration required for other life safety devices such as smoke and fire alarms, and has long been the recommend configuration by most knowledgeable security professionals. FEATURES • Made with MAGNASPHERE® BMS switch technology • Won't break • Resistant to contact welding • Resistant to outside defeat • Security industry's BEST warranty • Universal mounting • Cost competitive • Increases RMR Concealed/Recessed Surface Mount Overhead Door Wireless PATENTED DESIGN #5977873, #RE39731, #6506987, #6303845, #6603378, and Patents Pending To be supplied by McKinney and Installed by Convergint Door Frame Door Magnet CLOSED SECURE: NO ALARM Door Magnet NO ALARM Door Frame Door Magnet CLOSED Door Opened Door Frame CLOSED FAILED: NO ALARM DefeatMagnet FAILED: NO ALARM Door Opened Door Frame WELDEDCLOSED Reed contacts operate on magnetic fields. Most contacts are Closed in the secure position (Closed Loop) when the door is closed and the magnet is near the switch. When closed reed contacts are exposed to power surges such as lightning strikes, they are prone to permanent contact welding. Introducing a defeat magnet OUTSIDE the door will keep the reed contacts closed, allowing an intruder to enter without alerting the security system. They FAIL SECURE. Reed switch contacts are globally magnetic: they will respond to the strongest magnetic field anywhere around the contact –– not solely to the door magnet. When compromised, reed contacts will still send secure signals. Reed contacts operate by magnetic induction, so they are not attracted to the door magnet. Once contacts have welded closed, they remain in that state though the door is open. They FAIL SECURE. Security contacts are made with a decades-old technology called the Reed switch. Reed switches have three inherent weaknesses when used in security contacts: (1) Easily defeated with magnets, (2) Prone to permanent contact weld failure (from lightning and power surges), and (3) fragile (made mostly of glass, they are subject to damage even when packaged as security contacts). www.MAGNASPHERE.com© MAGNASPHERE CORP. MAGNASPHERE®®Reed vs. MAGNASPHERE security sensors' magnet ball contact is open in the secure position (Open Loop) when the door is closed and the door magnet is near the switch. MAGNASPHERE Security Sensors are Open Loop and highly resistant to contact welding from power surges and lightning strikes. A defeat magnet introduced OUTSIDE the door will have no effect on the ball contact. When the door is opened, the contact will close, and the SYSTEM WILL ALARM. Because the magnet ball contact will not weld, when the door is opened the contact will close and the SYSTEM WILL ALARM. MAGNASPHERE’s contact is a spherical magnet and operates in a defined activation zone directed toward the door magnet. The patented, award-winning MAGNASPHERE switch technology was designed as a security device which over comes the deficiencies of reed contacts. The MAGNASPHERE switch is (1) Resistant to magnetic defeat and tamper, (2) Resistant to permanent contact welding from lightning and power surges, and (3) Robust, all metal welded construction is virtually unbreakable. www.MAGNASPHERE.com© MAGNASPHERE CORP. MAGNASPHERE®®Reed vs. The Door is Closed OPEN SECURE: NO ALARM The Door is Closed OPEN NO ALARM ALARM The Door is Open CLOSED DefeatMagnet ALARM The Door is Open CLOSED ALARMCONTROLS alarmcontrols.com • 800.645.5538© 2016 Hanchett Entry Systems, Inc., an ASSA ABLOY Group Company Call Station Specifications • Contacts rated .5A at 35 VDC Features • Single gang satin stainless steel wall plate • Normally-open white flush push button Options • Available in all standard finishes • Custom silkscreening is available Model RP-100 Models RP-100 Single Gang Stainless Steel Wall Plate with N/O White Flush Push Button To be used for the door release buttons in corridor 220 and dining 217. Please confirm if text is required for the stainless wall plates AXIS M3047-P Network Camera 6 MP mini dome with 360°panoramic view AXIS M3047-P is an affordably priced fixed dome with a 6 MP sensor in an environment-friendly,discreet design.It offers 360°overview and dewarped views such as panorama,view area,corridor,corner and quad views with outstand- ing sharpness.HDMI support enables live streaming to an HDTV monitor for public viewing.Black,vandal-resistant and smoke-detector casings are available as accessories,and AXIS M3047-P is easily repaintable to blend in with any environment.Installation is quick with bayonet-fitted casing and easy cable connection.No manual focusing is needed since the camera comes factory-focused. >Complete panoramic overview with outstanding sharpness >Quick installation with small and discreet design >Zipstream for reduced bandwidth and storage >HDMI support enables streaming to a monitor >70%recycled plastics and PVC-free design Datasheet Interior 360 camera AXIS M3047-P Network Camera Camera Image sensor 6 MP (3072x2048)1/1.8”progressive scan RGB CMOS Lens F2.8,Fixed iris,Fixed focus,1.6 mm Horizontal field of view:185° Vertical field of view:185° Minimum illumination 0.3 lux at 50 IRE F2.8 Shutter time 1/31500 s to 1/2 s Camera angle adjustment Rotation ±180° Video Video compression H.264 (MPEG-4 Part 10/AVC)Baseline,Main and High Profiles Motion JPEG Resolution 360°overview:2048x2048 to 480x480 Panorama:2304x648 to 640x240 Double Panorama:2304x1296 to 480x360 Quad view:2304x1296 to 480x360 View area:1920x1440 to 480x360 Corner left or right:1920x720 to 640x240 Double Corner:1920x1440 to 480x360 Corridor:2304x1296 to 480x360 Frame rate 360°overview only,up to 2048x2048:30/25 fps @ 60Hz/50Hz Dewarped view in max resolution +360°overview up to 1920x1920:15/13 fps @ 60Hz/50Hz View area in 1280x720 +360°overview up to 1200x1200: 30/25 fps @ 60Hz/50Hz Video streaming Multiple,individually configurable streams in H.264 and Motion JPEG Axis Zipstream technology in H.264 Controllable frame rate and bandwidth VBR/MBR H.264 HDMI Multi-view streaming 360°overview.Dewarped panorama,corridor,corner and quad views.Two individually cropped out and dewarped view areas. The 360°overview can be streamed simultaneously with two view areas or one other dewarped view. HDMI output HDMI 720p@50/60 fps (50/60 Hz) Image settings Compression,color,brightness,sharpness,contrast,white balance,exposure control,exposure zones,WDR –dynamic contrast,noise reduction,rotation:0°,180°,text and image overlay,privacy masks,mirroring of images Pan/Tilt/Zoom Digital PTZ of view areas,preset positions,guard tour,digital tilt of panorama,and quad views Network Security Password protection,IP address filtering,HTTPSa encryption, IEEE 802.1Xa network access control,digest authentication,user access log,centralized certificate management,brute force delay protection Supported protocols IPv4,IPv6 USGv6,HTTP,HTTPSa,SSL/TLSa,QoS Layer 3 DiffServ, FTP,SFTP,CIFS/SMB,SMTP,Bonjour,UPnPTM,SNMP v1/v2c/v3 (MIB-II),DNS,DynDNS,NTP,RTSP,RTP,TCP,UDP,IGMP,RTCP, ICMP,DHCP,ARP,SOCKS,SSH,HDMI 1.4b System integration Application Programming Interface Open API for software integration,including VAPIX® and AXIS Camera Application Platform;specifications at www.axis.com AXIS Video Hosting System (AVHS)with One-Click Connection ONVIF®Profiles S and G,specifications at www.onvif.org Analytics Included AXIS Video Motion Detection,active tampering alarm Supported AXIS Motion Guard,AXIS Fence Guard,AXIS Loitering Guard Support for AXIS Camera Application Platform enabling installation of third-party applications,see www.axis.com/acap Event triggers Analytics,edge storage events,virtual inputs through API Event actions Record video:SD card and network share Upload of images or video clips:FTP,SFTP,HTTP,HTTPS,network share and email Pre-and post-alarm video or image buffering for recording or upload Notification:email,HTTP,HTTPS,TCP and SNMP trap Overlay text Data streaming Event data Built-in installation aids Pixel counter General Casing Aluminum and plastic casing,Encapsulated electronics Color:White NCS S 1002-B For repainting instructions of casing and impact on warranty, contact your Axis partner. Sustainability PVC free,70%recycled plastics Memory 1024 MB RAM,256 MB Flash Power Power over Ethernet (PoE)IEEE 802.3af/802.3at Type 1 Class 2 Typical 4.2 W,max 6.49 W Connectors RJ45 10BASE-T/100BASE-TX PoE HDMI Type Db Storage Support for microSD/microSDHC/microSDXC card Support for recording to dedicated network-attached storage (NAS) For SD card and NAS recommendations see www.axis.com Operating conditions 0 °C to 40 °C (32 °F to 104 °F) Humidity 10–85%RH (non-condensing) Storage conditions -40 °C to 65 °C (-40 °F to 149 °F) Approvals EMC EN 55024,EN 55032 Class A,EN 61000-6-1,EN 61000-6-2, FCC Part 15 Subpart B Class A,ICES-003 Class A,VCCI Class A, RCM AS/NZS CISPR 22 Class A,KCC KN32 Class A,KN35 Safety IEC/EN/UL 62368-1 Environment IEC 60068-2-1,IEC 60068-2-2,IEC 60068-2-6,IEC 60068-2-14, IEC 60068-2-27,IEC 60068-2-78 Network NIST SP500-267 Dimensions Height:46 mm (1.8 in) ø:101 mm (4.0 in) Weight 240 g (0.53 lb) Included accessories Installation guide,Windows decoder 1-user license,drill hole template Optional accessories AXIS T94B02D Pendant Kit AXIS T94B05L Recessed Mount AXIS T94B01P Conduit Back Box AXIS T94B02M J-Box/Gang Box Plate AXIS M30 Casing B,Black AXIS M30 Vandal-resistant Casing A AXIS M30 Smoke Detector Casing A Axis Mounts AXIS Surveillance microSDXC™Card For more accessories,see www.axis.com Video management software AXIS Companion,AXIS Camera Station,video management software from Axis’Application Development Partners available on www.axis.com/support/downloads AXIS Companion available on www.axiscompanion.com/vms, AXIS Video Hosting System (AVHS) Languages English,German,French,Spanish,Italian,Russian,Simplified Chinese,Japanese,Korean,Portuguese,Traditional Chinese Warranty Axis 3-year warranty and AXIS Extended Warranty option,see www.axis.com/warranty a.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.(www.openssl.org),and cryptographic software written by Eric Young (eay@cryptsoft.com). b.Make sure that the cable has a slim connector plug Environmental responsibility: www.axis.com/environmental-responsibility www.axis.com ©2017 -2018 Axis Communications AB.AXIS COMMUNICATIONS,AXIS,and VAPIX are registered trademarks or trademark applications of Axis AB in various jurisdictions.All other company names and products are trademarks or registered trademarks of their respective companies.We reserve the right to introduce modifications without notice. T10093115/EN/M7.2/1809 AXIS P3225-LV Mk II Network Camera Str eamlined HDTV 1080p fixed dome for any light conditions AXIS P3225-LV Mk II is a streamlined fixed dome that provides HDTV 1080p video.It features a varifocal lens and remote zoom and focus,which eliminates the need for hands-on fine tuning.Equipped with WDR –Forensic Capture to handle scenes with strong variations in light,Lightfinder technology for exceptional light sensitivity,as well as built-in IR illumination with OptimizedIR,this versatile camera provides outstanding video quality in any light conditions.It supports Axis Zipstream technology that significantly reduces bandwidth and storage requirements. >HDTV 1080p video quality >Remote zoom and focus >Lightfinder and WDR –Forensic Capture >OptimizedIR illumination >Axis Zipstream Datasheet Interior fixed view camera AXIS P3225-LV Mk II Network Camera Camera Image sensor Progressive scan RGB CMOS 1/3” Lens Varifocal,3.0–10.5 mm,F1.4 Horizontal field of view:92°–34° Vertical field of view:50°–20° Remote focus and zoom,P-Iris control,IR corrected Day and night Automatically removable infrared-cut filter Minimum illumination HDTV 1080p 25/30 fps with WDR -forensic capture and Lightfinder: Color:0.16 lux at 50 IRE,F1.4 B/W:0.03 lux at 50 IRE,F1.4,0 lux with IR illumination on HDTV 1080p 50/60 fps: Color:0.32 lux at 50 IRE,F1.4 B/W:0.06 lux at 50 IRE,F1.4,0 lux with IR illumination on Shutter time 1/66500 s to 1 s Camera angle adjustment Pan ±180°,tilt -35 to +75°,rotation ±95° Video Video compression H.264 Baseline,Main and High Profile (MPEG-4 Part 10/AVC) Motion JPEG Resolution 1920x1080 to 160x90 Frame rate With WDR:25/30 fps with power line frequency 50/60 Hz Without WDR:50/60 fps with power line frequency 50/60 Hz Video streaming Multiple,individually configurable streams in H.264 and Motion JPEG Axis Zipstream technology in H.264 Controllable frame rate and bandwidth VBR/MBR H.264 Multi-view streaming 2 individually cropped out view areas Pan/Tilt/Zoom Digital PTZ,preset positions Image settings Compression,Color,Brightness,Sharpness,Contrast,Local contrast,White balance,Exposure control (including automatic gain control),Exposure zones,Fine tuning of behavior at different light levels,WDR -forensic capture:Up to 120 dB depending on scene,Text and image overlay,Mirroring of images,Privacy masks Rotation:0°,90°,180°,270°,including Corridor Format Network Security Password protection,IP address filtering,HTTPSa encryption, IEEE 802.1Xa network access control,Digest authentication,User access log,Centralized Certificate Management,brute force delay protection Supported protocols IPv4,IPv6 USGv6,HTTP,HTTPSa,SSL/TLSa,QoS Layer 3 DiffServ, FTP,CIFS/SMB,SMTP,Bonjour,UPnPTM,SNMP v1/v2c/v3(MIB-II), DNS,DynDNS,NTP,RTSP,RTP,SRTP,SFTP,TCP,UDP,IGMP,RTCP, ICMP,DHCP,ARP,SOCKS,SSH,LLDP System integration Application Programming Interface Open API for software integration,including VAPIX® and AXIS Camera Application Platform;specifications at www.axis.com AXIS Video Hosting System (AVHS)with One-Click Connection ONVIF®Profile G,ONVIF®Profile S,and ONVIF®Profile T, specification at onvif.org Analytics Included AXIS Video Motion Detection,active tampering alarm Supported AXIS Motion Guard,AXIS Fence Guard,AXIS Loitering Guard, AXIS Perimeter Defender AXIS Digital Autotracking,AXIS People Counter, AXIS Tailgating Detector,AXIS Direction Detector, AXIS Occupancy Estimator,AXIS Random Inspection, AXIS Queue Monitor Support for AXIS Camera Application Platform enabling installation of third-party applications,see www.axis.com/acap Event triggers Analytics,edge storage events,virtual inputs through API Event actions Record video:SD card and network share Upload of images or video clips:FTP,SFTP,HTTP,HTTPS,network share and email Pre-and post-alarm video or image buffering for recording or upload Notification:email,HTTP,HTTPS,TCP and SNMP trap Overlay text Data streaming Event data Built-in installation aids Remote zoom,remote focus,pixel counter,optimized IR with adjustable IR illumination intensity General Casing IP52-rated,IK08 impact-resistant,polycarbonate casing with hard-coated dome and dehumidifying membrane Encapsulated electronics and captive screws Color:white NCS S 1002-B For repainting instructions of skin cover or casing and impact on warranty,contact your Axis partner. Mounting Mounting bracket with holes for junction boxes (double-gang, single-gang,and 4”octagon)and for wall or ceiling mount ¼”-20 UNC tripod screw thread Sustainability PVC free Memory 512 MB RAM,256 MB Flash Power Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3, max 10.2 W,typical 6.1 W Connectors Shielded RJ45 10BASE-T/100BASE-TX PoE IR illumination Optimized IR with power-efficient,long-life 850 nm IR LEDs with adjustable illumination intensity.Range of reach 30 m (100 ft)or more depending on scene Storage Support for microSD/microSDHC/microSDXC card Support for SD card encryption Support for recording to network-attached storage (NAS) For SD card and NAS recommendations see www.axis.com Operating conditions 0 °C to 50 °C (32 °F to 122 °F) Humidity 10 to 85%RH (non-condensing) Storage conditions -40 °C to 65 °C (-40 °F to 149 °F) Approvals EMC EN 55022 Class B,EN 61000-6-1,EN 61000-6-2,EN 55024, EN 50121-4,IEC 62236-4,FCC Part 15 Subpart B Class A and B, ICES-003 Class B,VCCI Class B,RCM AS/NZS CISPR 22 Class B, KCC KN22 Class B,KN24 Safety IEC/EN/UL 60950-1,IEC/EN 62471 Environment IEC 60068-2-1,IEC 60068-2-2,IEC 60068-2-14 IEC 60068-2-6 (vibration),IEC 60068-2-27 (shock), IEC 60068-2-78,IEC/EN 60529 IP52,IEC/EN 62262 IK08 Network NIST SP500-267 Dimensions Height:101 mm (4 in) ø 149 mm (5 7/8 in) Weight 550 g (1.2 lb) Included accessories Installation Guide,Windows decoder 1-user license,mounting bracket,cable gasket,Resistorx®T20 L-key,drill template, connector guard Optional accessories AXIS ACI Conduit Bracket B,AXIS ACI Conduit Adapters, AXIS T94K01L Recessed Mount Kit,AXIS T94K01D Pendant Kit, AXIS Skin Cover C,Black,AXIS Mounts,Smoked dome For more accessories,see www.axis.com Video management software AXIS Companion,AXIS Camera Station,Video management software from Axis’Application Development Partners available on www.axis.com/vms Languages English,German,French,Spanish,Italian,Russian,Simplified Chinese,Japanese,Korean,Portuguese,Traditional Chinese Warranty Axis 3-year warranty and AXIS Extended Warranty option,see www.axis.com/warranty a.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.(www.openssl.org),and cryptographic software written by Eric Young (eay@cryptsoft.com). Environmental responsibility: www.axis.com/environmental-responsibility www.axis.com ©2016 -2018 Axis Communications AB.AXIS COMMUNICATIONS,AXIS,and VAPIX are registered trademarks or trademark applications of Axis AB in various jurisdictions.All other company names and products are trademarks or registered trademarks of their respective companies.We reserve the right to introduce modifications without notice. T10080115/EN/M9.2/1812 AXIS P3225-LVE Mk II Network Camera Str eamlined,outdoor-ready HDTV 1080p fixed dome for any light conditions AXIS P3225-LVE Mk II is a streamlined,outdoor-ready fixed dome that provides HDTV 1080p video.It features a varifocal lens and remote zoom and focus,which eliminates the need for hands-on fine tuning.Equipped with WDR –Forensic Capture to handle scenes with strong variations in light,Lightfinder technology for exceptional light sensitivity,as well as built-in IR illumination with OptimizedIR,this versatile camera provides outstanding video quality in any light conditions.It supports Axis Zipstream technology that significantly reduces bandwidth and storage requirements.The vandal-resistant AXIS P3225-LVE Mk II is IK10 rated. >HDTV 1080p video quality >Outdoor ready and IK10 rated >Lightfinder and WDR –Forensic Capture >OptimizedIR illumination >Axis Zipstream Datasheet Exterior fixed view camera AXIS P3225-LVE Mk II Network Camera Camera Image sensor Progressive scan RGB CMOS 1/3” Lens Varifocal,3.0–10.5 mm,F1.4 Horizontal field of view:92°–34° Vertical field of view:50°–20° Remote focus and zoom,P-Iris control,IR corrected Day and night Automatically removable infrared-cut filter Minimum illumination HDTV 1080p 25/30 fps with WDR -forensic capture and Lightfinder: Color:0.16 lux at 50 IRE,F1.4 B/W:0.03 lux at 50 IRE,F1.4,0 lux with IR illumination on HDTV 1080p 50/60 fps: Color:0.32 lux at 50 IRE,F1.4 B/W:0.06 lux at 50 IRE,F1.4,0 lux with IR illumination on Shutter time 1/66500 s to 1 s Camera angle adjustment Pan ±180°,tilt -35 to +75°,rotation ±95° Video Video compression H.264 Baseline,Main and High Profile (MPEG-4 Part 10/AVC) Motion JPEG Resolution 1920x1080 to 160x90 Frame rate With WDR:25/30 fps with power line frequency 50/60 Hz Without WDR:50/60 fps with power line frequency 50/60 Hz Video streaming Multiple,individually configurable streams in H.264 and Motion JPEG Axis Zipstream technology in H.264 Controllable frame rate and bandwidth VBR/MBR H.264 Multi-view streaming 2 individually cropped out view areas Pan/Tilt/Zoom Digital PTZ,preset positions Image settings Compression,Color,Brightness,Sharpness,Contrast,Local contrast,White balance,Exposure control (including automatic gain control),Exposure zones,Fine tuning of behavior at low light,WDR -forensic capture:Up to 120 dB depending on scene, Text and image overlay,Mirroring of images,Privacy masks Rotation:0°,90°,180°,270°,including Corridor Format Network Security Password protection,IP address filtering,HTTPSa encryption, IEEE 802.1Xa network access control,Digest authentication,User access log,Centralized Certificate Management,brute force delay protection Supported protocols IPv4,IPv6 USGv6,HTTP,HTTPSa,SSL/TLSa,QoS Layer 3 DiffServ, FTP,CIFS/SMB,SMTP,Bonjour,UPnPTM,SNMP v1/v2c/v3(MIB-II), DNS,DynDNS,NTP,RTSP,RTP,SRTP,SFTP,TCP,UDP,IGMP,RTCP, ICMP,DHCP,ARP,SOCKS,SSH,LLDP System integration Application Programming Interface Open API for software integration,including VAPIX® and AXIS Camera Application Platform;specifications at www.axis.com AXIS Video Hosting System (AVHS)with One-Click Connection ONVIF®Profile G,ONVIF®Profile S,and ONVIF®Profile T, specification at onvif.org Analytics Included AXIS Video Motion Detection,active tampering alarm Supported AXIS Motion Guard,AXIS Fence Guard,AXIS Loitering Guard, AXIS Perimeter Defender AXIS Digital Autotracking,AXIS People Counter, AXIS Tailgating Detector,AXIS Direction Detector, AXIS Occupancy Estimator,AXIS Random Inspection, AXIS Queue Monitor Support for AXIS Camera Application Platform enabling installation of third-party applications,see www.axis.com/acap Event triggers Analytics,edge storage events,virtual inputs through API Event actions Record video:SD card and network share Upload of images or video clips:FTP,SFTP,HTTP,HTTPS,network share and email Pre-and post-alarm video or image buffering for recording or upload Notification:email,HTTP,HTTPS,TCP and SNMP trap Overlay text Data streaming Event data Built-in installation aids Remote zoom,remote focus,pixel counter,optimized IR with adjustable IR illumination intensity General Casing IP66-and NEMA 4X-rated,IK10 impact-resistant casing with hard-coated dome and dehumidifying membrane Encapsulated electronics and captive screws Color:white NCS S 1002-B For repainting instructions of skin cover or casing and impact on warranty,contact your Axis partner. Mounting Mounting bracket with holes for junction boxes (double-gang, single-gang,and 4”octagon)and for wall or ceiling mount ¼”-20 UNC tripod screw thread Sustainability PVC free Memory 512 MB RAM,256 MB Flash Power Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3, max 10.8 W,typical 7.3 W Connectors Shielded RJ45 10BASE-T/100BASE-TX PoE IR illumination Optimized IR with power-efficient,long-life 850 nm IR LEDs with adjustable illumination intensity.Range of reach 30 m (100 ft)or more depending on scene Storage Support for microSD/microSDHC/microSDXC card Support for SD card encryption Support for recording to network-attached storage (NAS) For SD card and NAS recommendations see www.axis.com Operating conditions -40 °C to 50 °C (-40 °F to 122 °F) Start-up:-30 °C to 50 °C (-22 °F to 122 °F) Maximum temperature (intermittent):55 °C (131 °F) Humidity 10 to 100%RH (condensing) Storage conditions -40 °C to 65 °C (-40 °F to 149 °F) Approvals EMC EN 55022 Class B,EN 61000-6-1,EN 61000-6-2,EN 55024, EN 50121-4,IEC 62236-4,FCC Part 15 Subpart B Class A and B, ICES-003 Class B,VCCI Class B,RCM AS/NZS CISPR 22 Class B, KCC KN22 Class B,KN24 Safety IEC/EN/UL 60950-1,IEC/EN/UL 60950-22,IEC/EN 62471 Environment IEC 60068-2-1,IEC 60068-2-2,IEC 60068-2-14 IEC 60068-2-6 (vibration),IEC 60068-2-27 (shock), IEC 60068-2-30,IEC 60068-2-78,IEC/EN 60529 IP66, NEMA 250 Type 4X,IEC/EN 62262 IK10 Network NIST SP500-267 Dimensions Height:104 mm (4 1/16 in) ø 149 mm (5 7/8 in) Weight 800 g (1.8 lb) Included accessories Installation Guide,Windows decoder 1-user license,mounting bracket,cable gasket,Resistorx®T20 L-key,drill template, connector guard Weathershield Optional accessories AXIS ACI Conduit Bracket A,AXIS ACI Conduit Adapters, AXIS T94M01L Recessed Mount Kit,AXIS T94T01D Pendant Kit including weather shield,AXIS Mounts,Smoked dome For more accessories,see www.axis.com Video management software AXIS Companion,AXIS Camera Station,Video management software from Axis’Application Development Partners available on www.axis.com/vms Languages English,German,French,Spanish,Italian,Russian,Simplified Chinese,Japanese,Korean,Portuguese,Traditional Chinese Warranty Axis 3-year warranty and AXIS Extended Warranty option,see www.axis.com/warranty a.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.(www.openssl.org),and cryptographic software written by Eric Young (eay@cryptsoft.com). Environmental responsibility: www.axis.com/environmental-responsibility www.axis.com ©2016 -2018 Axis Communications AB.AXIS COMMUNICATIONS,AXIS,and VAPIX are registered trademarks or trademark applications of Axis AB in various jurisdictions.All other company names and products are trademarks or registered trademarks of their respective companies.We reserve the right to introduce modifications without notice. T10080114/EN/M9.2/1812 Network Video Recording Software Lenel NVR 7.1 Bridge to Your Video Future The Lenel Network Video Recorder (LNVR) 7.1 provides a shared software technology platform that serves as the foundation for the next generation of Lenel’s advanced video management solutions. Available as either a benchmarked and optimized hardware-based turnkey solution, or a software-only package for deployment on Commercial Off The Shelf (COTS) server hardware, Lenel NVR provides a number of enhancements for Lenel video customers: • Reliable storage and instant retrieval • New timelapse support for H.264 and MPEG-4 streams • Fully compliant RTP/RTSP client/server implementation • Streaming video performance/stability improvements • Proven and updated recorder technology • Streamlined camera integration Quick & Efficient Video Retrieval • Supports auto or custom GOV lengths • Individual camera retention times • Indexed storage to better support remote storage locations • Restructured video index • Optimized for MJPEG, MPEG-4 and H.264 devices • Event-based recording configurations • Dual-path failover/redundant recording • Supports inputs/outputs on camera • Performance monitoring • Password protection Performance Improvements • Support for Windows 8 and 8.1, and Windows Server 2012 and 2012 R2 • Increased camera capacity • Supports VMware virtual environments • Reduces installation time, unattended installation and upgrades lenel.com/LenelNVR (866) 788-5095 Specifi cations subject to change without notice. © 2014 Lenel Systems International, Inc. All rights reserved. Lenel and OnGuard are registered trademarks of Lenel Systems International, Inc. All other trademarks and copyrights are the property of their respective owners. 2014/12 (80281) Feature-rich Lenel NVR provides an array of technology advantages Lenel NVR better supports our customers by increasing focus on video-related features, functionality and technology. By extracting the Lenel NVR code out of OnGuard, Lenel has been able to completely refactor and modernize the code to adopt industry- standard RTP/RTSP transport protocols resulting in signifi cant performance improvements in video storage and retrieval. Unified Technology Platform For years, Lenel NVR has operated as the reliable video recording engine for OnGuard customers. Lenel has extended the NVR’s capabilities by creating a shared software technology platform that continues to support the streaming video needs of OnGuard Video Manager and also serves as the foundation for the next generation of Lenel’s advanced video-management solutions. OnGuard and Prism Integration Seamless integration into OnGuard and Prism remains a key design principle for the Lenel NVR. Investment in Lenel NVR as a core technology platform demonstrates Lenel’s intense strategic focus on growing its video off erings while maintaining best-in- class integrated solutions. Camera Integration With Lenel NVR, Lenel continues to increase the number of supported cameras to more than 500 individual models. Lenel continuously publishes new models of compatible cameras, which are available as add-ons from the Lenel website. The Power of Choice with Lenel NVR Lenel NVR delivers the ultimate in fl exibility, empowering customers with the freedom to choose the hardware and software solutions that best suit their unique security environments. Lenel is committed to providing the industry- leading portfolio of video options to our customers, leveraging integration to provide an ecosystem of choice, allowing our customers to better defi ne how they manage, monitor and maintain their video surveillance systems. Available as software only, or in the following benchmarked turnkey configurations* *See Lenel NVR7 Technical Specifi cations for additional information. DVC-LP Chassis Low profi le chassis for limited rack space and low- to-moderate storage needs DVC-ST Hybrid Chassis Standard storage chassis for low-to-moderate storage needs DVC-EX Chassis Extended storage chassis for moderate-to-high storage needs DVC-HD Chassis High-density storage chassis for high storage needs