HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (38).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 004
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 004 Date Created: 7/26/2018
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ClarificationCivilAsphalt Paving & Patch Detail Clarification
Company Name Contact Name Copies NotesCc:
Chamberlin Architects, Inc. Daniel Gartner 1
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
Question Date Required: 8/2/2018
Please refer to the attached.
Per asphalt paving and patch details on C-501, asphalt paving and patch back is to be at a depth of 4" (2 lifts at 2" each).
T-patches are to be milled 24" on either side of the trench. However, the Aspen Consolidated Sanitation District standard
detail "Trench in Asphalt" on C-503 states to patch back asphalt with 5" and mill the t-patch at a width of 12". Note on this
detail also states "…..or as required by…engineer of record". Please clarify the requirement for asphalt paving/patch
thickness and t-patch width at the sanitary sewer trenches.
Suggestion
Answer Date Answered: 7/27/2018
Please use typical section for pavement section.
RBG
July 27th 2018
Within City ROW, 5" of Asphalt is required per the COA construction standard. The loop road can be 4" as shown in detail.
Use 2" on 3" ( total 5") in city ROW in Castle Creek and Dolittle.
RBG
JUly 30th 2018
Prolog Manager Printed on: 7/30/2018 FCI_Integration Page 1
TYP. CONC. S.W. SECTION
NOT TO SCALE
, q 1a' c(wss o corvc.
4' CV55 6 ABC
1
TYP. ASPH. PAVEMENT SECTION
NOT TO SCALE
1
2' HBP (PG 58-26 5% 75 GRADING)
2" HBP (PG 58-28 5% 75 GRADING)
T
8" CL158 6 ABC
1
TRENCR IN ASPHALT
SG E: N.T.S.
ACSD-07
aww� i AepeD Coneolideted Smtatum D'utdct
e , c eoHnoy m.. ebedREd Detdb
A®D-07
xwc (�wrj�xs emi
I