Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (41).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 007 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 007 Date Created: 8/2/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category ClarificationCivilDoolittle Inlet-2 Clarification Company Name Contact Name Copies NotesCc: Chamberlin Architects, Inc. Daniel Gartner 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 8/9/2018 Please refer to attached drawings. Per the Doolittle storm profile shown on sheet C-202, Doolittle pipe-1 and Doolittle pipe-2 drain into Doolittle Inlet-2. Per the attached profile, Doolittle pipe-1 is 24" ADS and Doolittle-2 is 15" RCP. Per the details for the Doolittle Inlet-2, one of the invert in pipes is 15" RCP which we are assuming is Doolittle Pipe-2 and there is a invert in of 24" RCP which we are assuming is Doolittle Pipe-1 it has just been shown as RCP. Please confirm Doolittle Pipe-1 is either ADS or RCP. Please also confirm that the invert out pipe is an existing condition that will have to be connected to the inlet. Suggestion Answer Date Answered: 8/7/2018 Doolittle Pipe-1 should be 24" ADS, the inlet label should read INV IN SW: 8006.50' 24" ADS. Doolittle Pipe-2 is correct, it should be 15" RCP. The 24" CMP Invert out pipe is an existing pipe that will need to be connected to. We do not want to replace this pipe as that would require crossing Doolittle Drive and replacing with RCP as it is in the city right of way. 8-7-2018 Prolog Manager Printed on: 8/7/2018 FCI_Integration Page 1 Please confirm if thisis ADS or RCP asshown above.15" RCP - AssumingDoolittle Pipe-224" RCP - Assuming Doolittle Pipe-1.Should be 24" ADS as shown below?