HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (47).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 013
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 013 Date Created: 8/23/2018
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ClarificationCivilParking Lot Signage Clarifications
Company Name Contact Name Copies NotesCc:
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
Chamberlin Architects, Inc. Daniel Gartner 1
Question Date Required: 8/30/2018
Pre-bid question and answers item #54 asked for details and specifications on site traffic signage. Architect/engineer
response was "Sign installation shall conform to CDOT detail S-614-8 (issued with Add. 02) and all signs shall conform to
the Manual on Uniform Traffic Control Devices". This response is too vague. Please provide clarification on the following
site signage questions specific to this project (also reference C-105):
1.) Per CDOT details S-614-8 issued, sheet 1 of 7 shows a "socket system" sign post detail, but Sheet 2 of 7 shows a
"slip-base" sign post detail. Which detail is wanted for this project?
2.) Please advise on the mounting heights (dimension to bottom of sign) for site signs.
3.) Please advise on the sign sizes (W x H) for each sign.
Suggestion
Answer Date Answered: 8/29/2018
1. The slip base detail should be used for all signs.
2. Mounting height for all signs should be 7 ft.
3.
- Wrong Way - 30" x 30"
- One Way - 36" x 12"
- Accessible Parking - 12" x 18"
- Stop Sign - 30" x 30"
- Speed Hump - 24" x 24"
Prolog Manager Printed on: 8/29/2018 FCI_Integration Page 1