Loading...
HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (57).ACBKDetailed, RFIs Grouped by RFI Number Request for Information 023 Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033 Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583 RFI #: 023 Date Created: 9/13/2018 Author Company Authored ByAnswer Company Answered By Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks 437 Main Street Grand Junction, CO 81501 P. O. Box 1767 Grand Junction, CO 81502 Co-Respondent Author RFI Number DisciplineSubject Category DirectionCivilNortheast Retaining Wall Elevation Company Name Contact Name Copies NotesCc: Chamberlin Architects, Inc. Daniel Gartner 1 FCI Constructors, Inc. - GJ Brady Blackmer 1 FCI Constructors, Inc. - GJ Brian Young 1 FCI Constructors, Inc. - GJ David Hale 1 Question Date Required: 9/20/2018 Please refer to the attached drawing. Per conversations on-site between Richard Goulding with Roaring Fork Engineering and Brian Young with FCI, there is an issue with the elevations of the retaining wall in the northeast corner of the parking lot and the concrete curb that is on the south side of the retaining wall. The retaining wall was poured with the top of wall elevation at 8009.51 and has been verified in the field. Per drawing C-112 the top back of curb on the south side of the retaining wall should be poured at an elevation of 8011.24. The two different elevations as stated above will leave the top back of curb approximately 20" taller than the top of the retaining wall. Please advise how FCI is to resolve the issue of having the top back of curb 20" taller than the top of the retaining wall. Suggestion Answer Date Answered: 9/19/2018 REFER TO ATTACHED SKETCH SSK-17 DATED 9/18/18 FOR RETAINING WALL MODIFICATIONS. 2018.09.18 - JONATHAN WEST Prolog Manager Printed on: 9/19/2018 FCI_Integration Page 1 WV IV compact compactcompactcompact DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE:C 2016 CHAMBERLIN ARCHITECTSNO:ISSUED FOR:DATE:P:\2017\44 - Pitkin Ambulance Facility\04-DWG\04-Sheetset\SS-AADF Overall.dwg7/18/2018 3:32 PM592 HIGHWAY 133 Carbondale, Colorado 81623 PH 970.340.4130 F 866.876.5873 CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N ASPEN AMBULANCE DISTRICT FACILITY CASTLE CREEK RD ASPEN, COLORADO PARKING LOT GRADING PLAN PROJECT STATUS: 100% CD SWW RBG C-1122017-44 7/18/2018 1 PR#1 7/18/18                             Poured TOW 8009.51 1' - 3" (V.I.F.) 1' - 0" (V.I.F.) 2' - 6" 1' - 0" 5' - 9" 3/4” CHAMFER (TYP.) FREE DRAINING GRAVEL AND/OR SAND BACKFILL MATERIAL ONLY (TYP.) T.O. WALL EL. 8011.26' CLR. 3 1/2" 8" T.O. EXISTING WALL EL. 8009.51' T.O. FOOTING EL. 8002.51' (V.I.F.)CLR.4 1/2"1' - 0"CLR.3 1/2"PAVEMENT RE: CIVIL (3) #4 HORIZ. NOTE: ROUGHEN TOP SURFACE OF EXISTING WALL & SIDES OF FOOTING. COAT W/ BONDING AGENT PRIOR TO CONCRETE PLACEMENT PER MFGR. (2) #4 CONT. (TYP.) #5 @ 16 DRILL & EPOXY 1'-0" INTO EXISTING CONCRETE (HILTI HIT HY 200) #5 @ 12 DRILL & EPOXY 1'-0" INTO EXISTING CONCRETE (HILTI HIT HY 200) #5 @ 12 VERT. DRILL & EPOXY 1'-0" INTO EXISTING CONCRETE (HILTI HIT HY 200) EXISTING RETAINING WALL DESCRIPTION: SCALE:DATE: PREPARED BY:PROJECT NO:PROJECT:ISSUED WITH:LOCATION: A.A.D.F.AS NOTED GRAND JUNCTION, COLORADO 970.242.6804 RAPID CITY, SOUTH DAKOTA 605.355.6804 RFI #2317.085 09/18/18 JDG Parking Lot Retaining Wall Section S303 SSK-17 1/2" = 1'-0"PARKING LOT RETAINING WALL SECTION