HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (62).ACBKDetailed, RFIs Grouped by RFI Number
Request for Information 027
Aspen Ambulance District Facility FCI Constructors, Inc. - GJProject # 10-17-033
Aspen, CO 81611 Tel: 970-434-9093 Fax: 970-434-7583
RFI #: 027 Date Created: 9/17/2018
Author Company Authored ByAnswer Company Answered By
Chamberlin Architects, Inc. Jonathan West FCI Constructors, Inc. - GJ Sam Meeks
437 Main Street
Grand Junction, CO 81501
P. O. Box 1767
Grand Junction, CO 81502
Co-Respondent Author RFI Number
DisciplineSubject Category
ClarificationStructuralSite Bollard Detail
Company Name Contact Name Copies NotesCc:
Chamberlin Architects, Inc. Daniel Gartner 1
FCI Constructors, Inc. - GJ Brady Blackmer 1
FCI Constructors, Inc. - GJ Brian Young 1
FCI Constructors, Inc. - GJ David Hale 1
Question Date Required: 9/24/2018
Please refer to the attached
Per the attached detail 1 on architectural sheet A653, (4) 6" bollards are to be installed on the inside of the trash
enclosure. There is not any details in the drawings to show height of bollard or any other details pertaining to the 6"
bollards.
Please provide a detail to show height of bollard and how deep the bollard will be burried.
Suggestion
Answer Date Answered: 9/17/2018
PIPE BOLLARD FINISH HEIGHT TO BE 36-INCHES ABOVE FINISHED GRADE W/ A MINIMUM EMBEDMENT OF
36-INCHES (12-INCH DIAMETER HOLE). PIPE BOLLARDS TO BE FILLED SOLID W/ CONCRETE (DOME CONRETE
TOP FOR DRAINAGE).
2018.09.17 - JONATHAN WEST
Prolog Manager Printed on: 9/17/2018 FCI_Integration Page 1
228 SFHHSSTORAGE402AABB1122RECYCLINGDUMPSTERCOMPOST187 SFTRASHA6533A6535A65346A653________________________________________401402IRRIGATION CONTROL PANEL6" CONC FILLED STL BOLLARD, TYP OF 435' - 4"22' - 8"6' - 8"16' - 8"3' - 4"12' - 8"A653107' - 4"92 SFFACILITYSTORAGE4010'4'8'0'4'8'A653DUMPSTER ENCLOSURE FLOOR PLAN11