HomeMy WebLinkAboutFile Documents.401 Castle Creek Rd.0024.2019 (7).ACBK CHILLED WATER RETURN CHILLED WATER SUPPLY COLD WATER COMPRESSED AIR HOT WATER - DOMESTIC HOT WATER - DOMESTIC, HOT WATER CIRCULATING - HEATING WATER RETURN HEATING WATER SUPPLY NATURAL GAS NITROUS OXIDE OXYGEN OVERFLOW STORM DRAIN PIPING SANITARY SEWER SANITARY VENT SNOWMELT RETURN SNOWMELT SUPPLY STORM DRAIN PIPING VACUUM CWR CWS CA HWR HWS G NO O SWR SWS V TEMPERATURE SHOWN DOMESTIC OST SS ST ELBOW ELBOW UP ELBOW DOWN TEE TEE UP TEE DOWN GATE OR GLOBE VALVE BALL VALVE CHECK VALVE SOLENOID VALVE BUTTERFLY VALVE RELIEF VALVE BALANCING VALVE, CALIBRATED ANGLE VALVE, GATE OR GLOBE UNION CONTROL VALVE, 2-WAY CONTROL VALVE, 3-WAY P-T PORT STRAINER THERMOMETER IN PIPELINE PRESSURE REGULATING VALVE HOSE BIBB PRESSURE GAUGE FLOOR DRAIN OR SHOWER DRAIN FLOOR SINK ROOF DRAIN HORIZONTAL CLEANOUT FLOOR CLEANOUT TWO-WAY CLEANOUT WASTE MRETURN OR EXHAUST DUCT DOWN, DIMENSION ACROSS LISTED FIRST SUPPLY DUCT DOWN SUPPLY DUCT UP RETURN OR EXHAUST DUCT UP DUCT ELBOW, DIMENSION OF SIDE SHOWN = 22" FLEXIBLE DUCT CONNECTION MANUAL VOLUME DAMPERS IN DUCTS SIDEWALL RETURN OR EXHAUST GRILLE RA-1, 12"Wx8"H SIDEWALL SUPPLY GRILLE OR REGISTER SA-1, 12"Wx8"H, 225 CFM CEILING RETURN GRILLE OR REGISTER RA-1, 12"x8" CEILING SUPPLY DIFFUSER, GRILLE, OR REGISTER SA-1, 24"x24", 225 CFM FIRE DAMPER COMBINATION FIRE/SMOKE DAMPER MOTORIZED CONTROL DAMPER IN DUCT 22"x10" 22"x18" T H T H THERMOSTAT / TEMPERATURE CONTROL HUMIDISTAT OR HUMIDITY SENSOR DUCT THERMOSTAT OR TEMPERATURE SENSOR DUCT HUMIDISTAT OR HUMIDITY SENSOR PIPING PIPING ACCESSORIES ABBREVIATIONS CONTROLS DUCTWORK M-1 A 1 1 SECTION INDICATOR A = SECTION DESIGNATION M-1 = SHEET DESIGNATION KEYED NOTE DESIGNATION DRAWING REVSION DESIGNATION GENERAL SYMBOLS M E C H A N I C A L A N D P L U M B I N G L E G E N D SA-1 EQUIPMENT DESIGNATION (REFER TO SCHEDULES AND SPECIFICATIONS) F F/S 12"x8" RA-1 SA-1 225 CFM 12"x8" 12"x8" RA-1 SA-1 225 CFM 24"x24" DUCT, DIMENSION OF SIDE SHOWN = 22" 22"x10" 110 REFRIGERATION LIQUIDRL REFRIGERATION SUCTIONRS DUCT ACCESSORIES AND DIFFUSERS GRILLES, REGISTERS,PIPING FITTINGS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BDD BACK DRAFT DAMPER BFG BELOW FINISHED GRADE CD CONDENSATE DRAIN CFM CUBIC FEET PER MINUTE COTG CLEANOUT TO GRADE CV CIRCUIT VENT CW COLD WATER DB DRY BULB TEMPERATURE EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EWT ENTERING WATER TEMPERATURE FCO FLOOR CLEANOUT °F DEGREES FAHRENHEIT FA FRESH AIR TEMPERED GC GENERAL CONTRACTOR HW HOT WATER - DOMESTIC HWC HOT WATER CIRCULATING - DOMESTIC HWR HOT WATER RETURN HWS HOT WATER SUPPLY LB POUNDS (WEIGHT) MA MIXED AIR MC MECHANICAL CONTRACTOR NIC NOT IN CONTRACT NK NECK (DUCT CONNECTION) NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER PC PLUMBING CONTRACTOR RA RETURN AIR RDL ROOF DRAIN LEADER RE:REFER TO SA SUPPLY AIR SDL STORM DRAIN LEADER SS SANITARY SEWER SWR SNOWMELT WATER RETURN SWS SNOWMELT WATER SUPPLY V VENT VTR VENT THROUGH ROOF WCO WALL CLEANOUT W WASTE WB WET BULB TEMPERATURE TEMPERATURE SENSOR PRESSURE SENSOR CARBON DIOXIDE SENSOR T P C VIBRATION ISOLATOR COLD WATER - FILTERED F MODEL BOILER SCHEDULE TAG BL-1 AREA SERVED SNOW MELT MANUFACTURER LAARS NTH 850 V/PH/HZ 115/1/60 POWER REQUIRED INPUT MBH WATER, STAINLESS STEEL, 95.7% EFFICIENCY TYPE 578 FLOW/ P MBH 553 43 GPM CONC. FLUID 40 FT 10 SNOW MELT CONTROLLER FLA 7.4 CONTROLS 1, 2 WEIGHT LBS 503 NOTES OUTPUT BL-2 BUILDING MUA HEAT TRIANGLE TUBE SOLO 110 115/1/6074.8 71 8 40-INTEGRAL CONTROLLER-103 1, 2 AIR COOLED CONDENSING UNIT SCHEDULE MANUFACTURER CU-1 CU-3 CU-2 TAG TRANEFR-1 FR-3 FR-2 TRANE TRANE FURNACE 37604TTX8060A1000B MODEL 208-230/1/60- AMBIENT °F POWER REQUIRED V/PH/HZ MCA CONTROLS 60 RE: SPECIFICATIONS MOCP 2, 3332 2, 3 2, 3 WEIGHT LBS NOTES CONTROLS MANUFACTURERTAGAREA SERVED DUCT HEATING COIL SCHEDULE MODEL CFM NOTES / ACCESSORIESLBS WEIGHTCAPACITY MBH EAT °F EWT °FROWS AIR DIFF PRESSURE IN. W.C. WATER FLOW GPM WATER DIFF PRESSURE FT RUNOUT PIPE SIZE INCH TYPE SIZE INCHES Cv H E A T I N G C O N T R O L V A L V E REFER TO SPECIFICATIONSHC-1 ERV-1 TRANE DT0B09012 --0.53-WAY BALL1/20.80.151160407.2270 - INCHES 12 X 9 W X H SIZE FOOT 110 PER FINS MANUFACTURER ENERGY RECOVERY VENTILATOR SCHEDULE ERV-1 TAG AREA SERVED FR-1 OFFICES RENEWAIRE (1) 1/2INDOOR, PARALLEL PLATES, SENSIBLE & LATENT TYPE EV 450 IN MODEL 270 CFM 1.0 IN. W.C. AIR FLOW POWER REQUIRED SONES SOUND HP MOTOR - dBA 115/1/60 V / PH / HZ -15 MOCP ACCESSORIES LBS. WEIGHTCONTROLS 320 1, 2, 3, 5 NOTES ERV-2 FR-2 GROUND LEVEL RENEWAIRE (2) 3/4INDOOR, PARALLEL PLATES, SENSIBLE & LATENTHE1XRTV ECM 540 1.0 -208/230/1/60-15 320 1, 2, 3, 5 10.1 MCA 10.5 78 SENSIBLE 72 TOTAL EFFECTIVENESS % (AHRI 1060) 74 68 61 TOTAL 58 WINTER SUMMER ERV-2 FR-3 DORMITORY RENEWAIRE INDOOR, PARALLEL PLATES, SENSIBLE & LATENTEV 450 IN 330 1.0 -115/1/60-15 320 1, 2, 3, 510.1757059 REFER TO SPECIFICATIONSHC-2 ERV-2 TRANE DT0B12014 --0.53-WAY BALL1/2<1.01.50.0511604014.4540 -14 X 12 110 REFER TO SPECIFICATIONSHC-3 ERV-3 TRANE DT0B09012 --0.53-WAY BALL1/21.00.051160408.7330 -12 X 9 110 WATER, STAINLESS STEEL, 95% EFFICIENCY PROP. GLY RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS NOMINAL COOLING CAPACITY MBH 37604TTX8060A1000B208-230/1/60-60 RE: SPECIFICATIONS 332 37604TTX8060A1000B208-230/1/60-60 RE: SPECIFICATIONS 332 <1.0 <1.0 (1) 1/2 16.0 SEER ARI 16.0 16.0 SCHEDULE NOTES: 1.LISTED PERFORMANCE IS AT 8000 FT ALTITUDE. 2.PROVIDE SPECIFIED EQUIPMENT OR APPROVED EQUIVALENT BY OTHER MANUFACTURER. 3.LISTED PERFORMANCE IS AT SEA LEVEL. 4.PROVIDE WITH RETURN AIR DUCT SMOKE DETECTOR TO SHUT DOWN FURNACE. 5.NORMALLY OPEN CONTROL VALVE. 6.BALANCE AIR VOLUME TO EQUAL KITCHEN RANGE HOOD FAN EF-3. 7.REFER TO SPECIFICATIONS FOR REQUIRED ACCESSORIES. DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing M001 MECHANICAL LEGEND 2/27/2019 CHANGES COMPILED FOR BUILDING DEPARTMENT- 08/13/2019 MANUFACTURER EXHAUST FAN SCHEDULE COOKEF-2 EF-3 RANGE HOOD WOLF EF-1 TAG AREA SERVED APPARATUS BAYS COOK INLINE CENTRIFUGAL 115/1/605.05373 W0.375200 165SQN17D (VF) - -808331 600 --115/1/60--~3.0 1 HPCEILNG CENTRIFUGAL TYPE GC-188 MODEL 2700 CFM 0.75 IN. W.C. AIR FLOW POWER REQUIRED SONES SOUND HP OR W MOTOR 69 dBA 208/3/60 V / PH / HZ 16.1 - FLA ACCESSORIES <40 -- LBS. WEIGHTCONTROLS 125 1, 2 1, 2 PROVIDED WITH HOOD BY G.C. NOTES RE: SPECIFICATIONS RE: SPECIFICATIONS CONTROLS RE: SPECIFICATIONS MANUFACTURER FR-1 TAG FR-3 FR-2 OFFICES AREA SERVED DORMITORY GROUND FLOOR FURNACE SCHEDULE COOLING COIL 2200 2000 2000 BLOWER DATA S9X2C100U4PSAA S9X2C100D5PSAA S9X2C100U4PSAA MODEL CFM 0.7 1 INCH W.C. 0.7 E.S.P. 0.7 1 1 HP MODEL 2TXCD061AC3CU HEATING CAPACITY BLOWER MOTOR OUTPUT (MINIMUM) - - - EAT db/wb °F 61 61 61 AHRI RATING MBH 100 100 100 MBH POWER REQUIRED 2 115/1/60 2 STAGES 2 115/1/60 115/1/60 V/PH/HZ 14.4 14.4 14.4 FLA 2, 3, 4 2, 3, 4 2, 3, 4 NOTES / ACCESSORIES - - - LBS WEIGHT GRILLES, REGISTERS AND DIFFUSERS SCHEDULE TAG TYPESERVICE MOUNTING FINISHPATTERN THROW ACCESSORIES SIZESERIES # KRUEGER NOTES 100 HEATING CAPACITY INPUT, MBH (SEA LEVEL) SUPERIOR RADIANT INFRARED HEATER SCHEDULE 106, 107 AREA SERVED IR-1 TAG MANUFACTURER UX-100 40FT U-TUBE MODEL LOW INTENSITY TUBULAR TYPE THERMOSTAT1 HEATING STAGES 1.0115/1/60 V / PH / HZ FLA POWER REQUIRED CONTROLS NOTES TUBE LENGTH = 40 FT. NOTES 2, 3 175SUPERIOR RADIANT108-111IR-2 & IR-3 UX-175 60 FT U-TUBE THERMOSTAT11.0115/1/60 WEIGHT LBS 277 205 LOUVER SCHEDULE TAG TYPESERVICE MOUNTING FINISH ACCESSORIES SIZEMODEL NOTES RELIEF & EXHAUST AIRLR-1 DRAINABLE STATIONARY LOUVER WALL ELF6350DMPCOLOR CHOSEN BY ARCHITECT RE: SPECIFICATIONS AS NOTED ON PLANS 2, 3 RUSKIN INCH W.C. 0.10"WC @ 900 FT/MIN PRESS. DROP OZ./FT FREE AREA < 0.18 @ 1250 FT/MIN WATER ENTRY 2 SINGLE-STAGE IN-LINE PUMP SCHEDULE TAG PC-1 PC-3 SERVICE SNOW MELT BOILER BL-1 MANUFACTURER GRUNDFOS GRUNDFOS MODEL TP 32-80/2 POWER REQUIRED V/PH/HZFT TYPE GPM 43 FLOW AND TDH CONC. 40 3450 RPM MOTOR 17 0.5 HP MOTOR HP OR W WEIGHTCONTROLS FLA 7.4 RE: SPECIFICATIONS NOTES 1, 2 LBS 58 CANNED ROTOR IN-LINEUPS 32-80 F 115/1/608.2 40 -21 280 W - 1, 2 - ANTIFREEZE ADDITIVE TYPE PROP GLY PROP GLYBUILDING HEAT CONTROLSMANUFACTURER CH-1 TAG STAIR 303 AREA SERVED TRANE FAN COIL AND CABINET HEATER SCHEDULE B L O W E R FFFB0301 MODEL CFM INCH W.C. E.S.P.HP 1, 2, 5 NOTES / ACCESSORIES - LBS WEIGHTCAPACITY MBH EAT °F EWT °F ROWS AIR DIFF PRESSURE IN. W.C. WATER FLOW GPM WATER DIFF PRESSURE FT RUNOUT PIPE SIZE INCH TYPE SIZE INCH Cv H O T W A T E R C O I L H E A T I N G C O N T R O L V A L V E DRIVE POWER V/PH/HZ 11/23-WAY ZONE1/25.91.0-21406010.0115/1/60DIRECT0.130-300 SUPPLY SA-1 DIFFUSER, ROUND NECK, SINGLE FACEPLATE CEILING, T-BAR PLQ-23BRITISH WHITE4-WAY -AS NOTED ON PLANS STEEL. NOTE 2 SUPPLY SA-2 AIR FOIL BLADES, 3/4" CENTERS, VERTICAL FRONT, DOUBLE DEFLECTION SIDEWALL AF880V-F22ADJUSTABLE -STEEL, 1-1/4" FRAME. NOTE 2BRITISH WHITE AS NOTED ON PLANS SA-3 SUPPLY SA-4 HARD CEILING, PLASTER FRAMESUPPLY SA-5 DIFFUSER, ROUND NECK, SINGLE FACEPLATE PLQ-23-OBDBRITISH WHITE4-WAY PLASTER FRAME, DAMPER AS NOTED ON PLANS STEEL, LAY INTO 12"x12" PLASTER FRAME. NOTE 2 CEILING, T-BARRETURN RA-1 GRILLE, 1/2" CUBE CORE EGC5-F22BRITISH WHITEN/A -AS NOTED ON PLANS ALUMINUM. NOTE 2 STEEL, HORIZONTAL FIXED, 1-1/4" FRAME. NOTE 2RETURN RA-2 AIR FOIL BLADES, 3/4" CENTERS, 45° ANGLE SIDEWALL AFCS80-F22BRITISH WHITEN/A -AS NOTED ON PLANS EXHAUSTEA-1 SPLIT SYSTEM SCHEDULE SS-1 DAIKIN FTXS09DVJU / RXS09DVJU AREA SERVEDTAG MANUF.MODEL 8.5 10 208-230/1/60 5 15 WIRED T'STAT OUTDOOR = 74, INDOOR = 17 2, 4 NET TOTAL COOLING CAP. MBH (SEA LEVEL) HEATING CAP. MBH POWER REQUIRED V/PH//HZ MOCP UNITUNIT MCA CONTROLS WEIGHT LBS NOTES 211 I.T. APPARATUS BAYS ALUMINUM, HORIZONTAL 35° BLADES, 1/2" CENTERS. NOTE 2GRILLE, SIDEWALL, 35° DEFLECTION.HARD CEILING OR DUCT S585HBRITISH WHITEN/A -AS NOTED ON PLANS CURVED INDIVIDUALLY ADJUSTABLE BLADES CEILING, T-BAR 180-F231-WAY BRITISH WHITE OBD AS NOTED ON PLANS STEEL, 24"x12" LAY-IN PANEL. NOTE 2SUPPLY SUPPLY DIFFUSER, RECTANGULAR NECK, BEVELED FRAME DUCT SHPC-F21BRITISH WHITE4-WAY OBD AS NOTED ON PLANS STEEL, ADJUSTABLE VERTICAL THROW. NOTE 2 DUCT OR GYPGRILLE, 1/2" CUBE CORE EGC5-F22BRITISH WHITEN/A -AS NOTED ON PLANS ALUMINUM. NOTE 2RETURN RA-3 EXHAUSTEA-2 CEILING, T-BARGRILLE, 1/2" CUBE CORE EGC5-F22BRITISH WHITEN/A -AS NOTED ON PLANS ALUMINUM. NOTE 2 FC-1 KITCHEN MAKEUP AIR TRANE BCHD024A2**--M02Z000--BB-1, 2, 5, 618021/23-WAY BALL3/42.43.90.284140-1513.3115/1/60DIRECTECM 1/2 0.75500-600 SUPPLY SA-6 HEAVY DUTY, SINGLE DEFLECTION, HORIZONTAL BLADES SIDEWALL 480HBRITISH WHITEADJUSTABLE -AS NOTED ON PLANS STEEL, BLADES ON 1/2" CENTERS, 1 1/2" FRAME. NOTE 2 LOW INTENSITY TUBULAR TUBE LENGTH = 60 FT. NOTES 2, 3 RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS RE: SPECIFICATIONS CANNED ROTOR IN-LINECP-1 DOMESTIC HW RECIRC GRUNDFOS UP15-10B5/LC 115/1/602--4.3 1/25 HP -1, 2-NONE RE: SPECIFICATIONS INLINE CENTRIFUGAL SUPPLY SA-7 AIR FOIL BLADES, 3/4" CENTERS, VERTICAL FRONT, DOUBLE DEFLECTION SIDEWALL AF880V-F22-OBDADJUSTABLE OBD STEEL, 1-1/4" FRAME. NOTE 2BRITISH WHITE AS NOTED ON PLANS TRANE TRANE TRANE 2TXCD061AC3CU 2TXCD061AC3CU15 15 15 MOCP 0.35 0.30 0.30 AIR PRESS DROP INCH W.C. PC-4 GRUNDFOS CANNED ROTOR IN-LINEUPS 32-80 F 115/1/608.2 40 -21 280 W --PROP GLYBUILDING HEAT RE: SPECIFICATIONS 1, 2 SINGLE-STAGE IN-LINEPC-2 SNOW MELT SLAB GRUNDFOS TP 32-160/2 43 40 345036 0.75 HP 9.6 RE: SPECIFICATIONS 1, 260PROP GLY 115/1/60 RE: SPECIFICATIONS 115/1/60 2, 7SP-1 HYDROMATIC SUBMERSIBLECSS-3V 115/1/6020--19 0.3 HP --NONEELEVATOR PIT RE: SPECIFICATIONS SCHEDULE NOTES: 1.LISTED PERFORMANCE IS AT 8000 FT ALTITUDE. 2.PROVIDE SPECIFIED EQUIPMENT OR APPROVED EQUIVALENT BY OTHER MANUFACTURER. 3.LISTED PERFORMANCE IS AT SEA LEVEL. 4.PROVIDE WITH RETURN AIR DUCT SMOKE DETECTOR TO SHUT DOWN FURNACE. 5.NORMALLY OPEN CONTROL VALVE. 6.BALANCE AIR VOLUME TO EQUAL KITCHEN RANGE HOOD FAN EF-3. 7.REFER TO SPECIFICATIONS FOR REQUIRED ACCESSORIES. DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing M002 MECHANICAL SCHEDULES 2/27/2019 CHANGES COMPILED FOR BUILDING DEPARTMENT- 08/13/2019 A B C D E H I J 1 2 4 5 6 7 LOBBY 101 WOMEN 102 MEN 103 TRAINING ROOM 104 ELEC. 105 APPARATUS BAY #1 106 APPARATUS BAY #2 107APPARATUS BAY #3 108 APPARATUS BAY #4 109 APPARATUS BAY #5 110 APPARATUS BAY #6 111 DECON 112 READY ROOM 113 MEDICAL STORAGE 114 FITNESS 115 STAIR 302 ELEVATOR 301 STAIR 303 3 STORAGE 116 F 0 G GROUND LEVEL MECHANICAL PLAN IR-1IR-2 IR-3 CH-1 UNDER STAIRS SS-1 8'-0" AFF COMBUSTION AIR AND EXHAUST THROUGH WALL >10' HORIZONTALLY FROM AIR INTAKE ABOVE WITH CENTERLINE AT 13'-6" AFF (TYP OF 3) CU-3 SA-2 12"x12" 430 CFM 20"x20" SA AND RA THROUGH FLOOR ABOVE 14"Ø RA UP THROUGH FLOOR ABOVE SA-1 14"Ø 735 CFM SA-3 9"x9" 240 CFM SA-3 9"x9" 230 CFM SA-1 6"Ø 75 CFM SA-5 6"Ø 50 CFM SA-5 6"Ø 30 CFM EA-1 6"x6" 70 CFM EA-1 6"x6" 70 CFM EA-1 6"x6" 40 CFM 0'8' 4'OARAEAFACU-2 CU-1 RA-2 18"x18" RA-1 24"x24" RA-3 10x10" RA-3 10x10" RA-1 12"x24" SA-5 6"Ø 100 CFM T M T 12"Ø AT 12'-0" AFF AT 12'-0" AFF 12"Ø SPIRAL10"Ø SPIRAL6"Ø SPIRAL 20"x20" 12"Ø 6"Ø SPIRAL 10"Ø SPIRAL M 6"Ø SPIRAL 8"Ø SPIRAL ERV-2 20"x20" HC-2 12"Ø 14"x12" EA-2 24"x12" 320 CFM 12"Ø EA AND OA THROUGH FLOOR ABOVE 6"Ø 6"Ø T SWSSWRSWSSWRSWSSWR SWSSWR2" PIPING THROUGH FLOOR ABOVE EF-1 13'-4" AFF 22"x22" EA-1 36"x20" SA-2 22"x26" 2700 CFM OA 17"x22" RADIUSED ELBOW TO 17"x22" THROUGH FLOOR ABOVE 28"x15" OA EF-2 13'-4" AFF6"Ø EA BDD 22"x26" BDD VENT HOOD (TYP OF 3) INTAKE HOOD (TYP OF 3) ALL REFRIGERANT PIPING ON GALVANIZED STRUT ANCHORED IN PLACE AND COVERED WITH 18 GAUGE GALVANIZED HAT CHANNEL PROTECTIVE LID CAPABLE OF WITHSTANDING HUMAN FOOT TRAFFIC 30 CFM SA-1 14"Ø 735 CFM RA-1 24"x12" 6"Ø T TT RADIANT TUBE CENTERLINE AT 12'-4" AFF RADIANT TUBE CENTERLINE AT 12'-4" AFF RADIANT TUBE CENTERLINE AT 12'-4" AFF 12"Ø 4"Ø UNDERCUT 8"Ø, Voa=185CFM 4"Ø, Voa= 35CFM 10"Ø, Voa=320CFM 14"x26" OA FROM ABOVE TO 22"x26" 13'-4" AFF FACING DOWN DIRECTING AIR EAST PIPING THROUGH STRUCTURE REFRIGERANT PIPING UP IN WALL TO NEAR STRUCTURE ABOVE REFRIGERANT PIPING THROUGH FLOOR ABOVE M 1/2" HWS AND HWR ON WALL BOLT CONDENSING UNIT TO HOUSEKEEPING PAD IN FOUR PLACES (TYP) 12" LONG 4" FLEX DUCT 24" LONG TYPE B 4" FLEX VENT 12" LONG 4" FLEX DUCT 24" LONG TYPE B 4" FLEX VENT 12" LONG 4" FLEX DUCT 24" LONG TYPE B 4" FLEX VENT 1 233 4 HOUSEKEEPING PAD (TYP) 12"Ø 3/4" HWS AND HWR FROM ABOVE PROVIDE RESTRAINTS ATTACHED TO WALL AND ANCHOR SS-1 TO SHELF. CARBON MONOXIDE DETECTOR FOR EF-1 CONTROL AND ALARM, ℄ AT 5'-0" AFF AT 12'-0" AFF AT 12'-0" AFF 1/2" HWS AND HWR FROM ABOVE 10"Ø SUPPORT ON TRAPEZE WITH < 12" LONG RODS AND SWIVELS AT ENDS OF RODS 12"Ø BYPASS AND DAMPER M 4 4 GENERATOR INSTALL PIPING NEXT TO WALL 17 KEYED NOTES 1.INSTALL TOP OF UNIT AT 2" BELOW JOISTS. HANG FROM JOISTS WITH RODS AND B-LINE CHSCS SERIES ISOLATORS AT FOUR CORNERS. INSTALL STRUT BRACING TO STRUCTURE IN NORTH-SOUTH AND EAST-WEST DIRECTIONS WITH B-LINE SERIES CNNK PADS AT BRACE CONNECTION POINTS . 2.REFER TO IR-1 INFRARED HEATER SUPPORT DETAIL ON SHEET M301. 3.REFER TO IR-2 AND IR-3 INFRARED HEATER SUPPORT DETAIL ON SHEET M301. 4.SUPPORT ON TWO STRUT SPANNING ACROSS AND ANCHORED TO TWO JOISTS. INSTALL B-LINE SERIES RM-D NEOPRENE MOUNTS ANCHORED TO FAN AND STRUT. NOTED OTHERWISE. GENERAL NOTES APPLICABLE TO ALL MECHANICAL PLANS THE MECHANICAL CONTENT OF THIS DRAWING IS DIAGRAMMATIC AND NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO LOCATIONS OF DUCTWORK, EQUIPMENT, PIPING, AND SUPPORTS IN ORDER TO COORDINATE WITH BUILDING CONSTRUCTION AND WORK OF OTHER TRADES. ALL BRANCH DUCTS SERVING ONE DIFFUSER OR EXHAUST GRILLE SHALL INCLUDE A VOLUME DAMPER AT THE BRANCH DUCT POINT OF ORIGIN, UNLESS THE GRILLE OR DIFFUSER HAS BEEN SPECIFIED TO INCLUDE A BALANCING DAMPER. BRANCH DUCTS SERVING SINGLE DIFFUSERS SHALL BE SIZED TO MATCH THE DIFFUSER NECK SIZE UNLESS OTHERWISE INDICATED. ALL FLOOR PENETRATIONS SHALL BE FINISHED WITH FIRE STOP MATERIALS IN ACCORDANCE WITH THE SPECIFICATIONS. INDICATED DUCT DIMENSIONS ARE SHEET METAL DIMENSIONS. ROUND DUCTS ARE INDICATED USING SINGLE LINE. REFER TO SCHEDULES AND SPECIFICATIONS FOR EQUIPMENT AND MATERIALS OF CONSTRUCTION. AIR VOLUME INDICATED FOR SA DIFFUSERS AND SA GRILLES INCLUDES AIR FROM FURNACE AND VENTILATION AIR FROM ERV. INDICATED MOUNTING HEIGHTS ARE TO BOTTOM OF EQUIPMENT UNLESS NOTED OTHERWISE. DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing M101 GROUND LEVEL MECHANICAL PLAN PR#020 02/27/20194 17 PR#021 3/11/2019 RE: RFI-154. Per RFI-154 IR-1 is to be reconfigured to be 20' long single radiant tube with a 20' long reflector installed on grid line E. No longer a U-Tube. 08/13/2019 A B C D E H I J 1 2 4 5 6 7 WAITING 201 OFFICE 203 OFFICE 204 OFFICE 205 FLEX 206 MECH/ELEC 209 CORRIDOR 210 STOR. 213 OFFICE 212 CONFERENCE 214 LIBRARY / REPORTS 215 CORRIDOR 220 UNIFORM LOCKERS 221 LAUNDRY 222 CORRIDOR 224 SHOWER 225 SHOWER 226 SHOWER 227 BUNK RM 229 BUNK RM 230 BUNK RM 231 BUNK RM 232 STORAGE 228 3 TOILET 208 IT 211 DINING 217 DAYROOM 216 KITCHEN 218 MECH 223 F PANTRY 219 STAIR 303 STAIR 302 ELEVATOR 301 0 G DECK 233 UPPER LEVEL MECHANICAL PLAN BL-1 LR-1 11'-11"x2'-9 3/4" SS-1 LR-1 36"x132" LR-1 36"x30" 4"Ø DRYER VENT DUCT 36" AFF 14"Ø SPIRAL OA THROUGH STRUCTURE SA-2 16"x14" 710 CFM SA-1 6"Ø 105 CFM SA-1 8"Ø 135 CFM SA-1 6"Ø 100 CFM SA-1 6"Ø 110 CFM SA-4 12"x6" 150 CFM SA-4 20"x8" 315 CFM SA-4 16"x8" 265 CFM SA-2 24"x12" 910 CFM SA-2 18"x12" 580 CFM SA-1 6"Ø 100 CFM SA-1 8"Ø 120 CFM SA-1 6"Ø 100 CFM SA-1 6"Ø 70 CFM SA-1 6"Ø 80 CFM 14"Ø SPIRAL SA THROUGH STRUCTURE 12"Ø SPIRAL RA THROUGH STRUCTURE 12"Ø EA FROM HOOD 0'8' 4' PC-1 BL-2 COMBUSTION EXHAUST AND AIR PIPING AT 7'-2" AFF. INSULATE INDOOR COMBUSTION AIR PIPING. BL-2 PC-3 EA-1 6"x6" 70 CFM EA-1 8"x8" 70 CFM EA-1 8"x8" 70 CFM EA-1 8"x8" 70 CFM OARA EAFA SA-2 14"x14" 170 CFM 12" SPIRAL RA 8"Ø, Voa=200CFM FR-1 FR-2FR-3 DX-1 DX-2DX-3 ERV-1 AT FLOOR SA-2 32"x24" AT 8" AFF 600 CFM (2) 5"x14" DUCTS DOWN IN WALL BL-1 COMBUSTION EXHAUST AND AIR PIPING AT 7'-2 AFF. INSULATE INDOOR COMBUSTION AIR PIPING. TA-1 6"Ø TA-1 6"Ø TA-1 6"Ø RA-2 24"x18" RA-1 24"x12" 15"x26"32"x24" M M M M M M MM ERV-3 HC-3 RA-1 24"x12" 50 CFM RA-1 24"x12" FC-1 M BDD TA-1 6"Ø RA-2 6"x6" 16"x16" 9"Ø 16"x15"M M M 12"Ø M (3) 3" COMBUSTION AIR AND (3) 3" COMBUSTION EXHAUST THROUGH JOISTS TO AND FROM FURNACES. INSULATE INDOOR COMBUSTION AIR PIPING. MINIMIZE NUMBER OF ELBOWS. PC-4 T T T T T T T T M 8"Ø10"Ø 6"Ø, 75CFM SA-1 6"Ø 80 CFM SA-1 6"Ø 80 CFM RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" 9"Ø 8"Ø 5"Ø5"Ø 5"Ø 6"Ø 6"Ø 6"Ø 8"Ø 9"Ø 12"Ø 6"Ø 6"Ø 6"Ø 6"Ø 6"Ø 8"Ø RA-2 14"x14" 8"Ø 8"Ø 6"Ø, Voa=100CFM 6"Ø 8"Ø 12"Ø 14"Ø RA FROM BELOW 10"Ø SPIRAL RA 32"Ø SPIRAL EA 6"Ø SPIRAL FA 16"Ø SPIRAL SA 32"Ø SPIRAL OA 3 14"Ø SPIRAL SA T 14"Ø SPIRAL OA 16"Ø SPIRAL 8"Ø 6"Ø 6"Ø 2" SWS AND SWR THROUGH FLOOR 7"Ø 6"Ø 7"Ø 15"x5" ABOVE BEAM 10"Ø 7"Ø EF-3 SUSPEND FROM JOISTS SA-5 6"Ø 30 CFM 4"Ø 3"Ø, Voa=15CFM 10"Ø 3"Ø, Voa=25CFM SA-7 10"x8" 150 CFM 10"Ø 3"Ø, Voa=25CFM 3"Ø, Voa=25CFM 3"Ø, Voa=15CFM 3"Ø, Voa=15CFM 3"Ø, Voa=15CFM T HC-1 LR-1 9'-1"x2'-9 3/4" LR-1 8'-4"x2'-9 3/4" LR-1 9'-9-1/2"x2'-9 3/4" 17"x22" EA THROUGH FLOOR BELOW, TRANSITION TO 36"x30" INTO LOWER 30" OF LOUVER HWS HWR HWS HWR HWSHWRHWRHWSHWR HWS 12"Ø 14"x26" 14"x26" THROUGH FLOOR BELOW 36"x30" TO 36"x26" 1 2 4 5 6 7 20"x18" RA 20"x18" SA 10'-6" AFF 18"Ø 5"Ø OA REFRIGERANT PIPING FROM BELOW TO DX COILS 10 8HWRHWS RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" RA-1 24"x12" RANGE HOOD PC-2 COORDINATE LOCATION OF FURNACES WITH STRUCTURE ABOVE AND BELOW 11 11 12 ANCHOR TO WALL PER BL-2 INSTALLATION INSTRUCTIONS ATTACH BL-1 TO HOUSEKEEPING PAD WITH 3/8" CONCRETE ANCHORS 12"Ø 1/2" HWS AND HWR DOWN IN WALL THROUGH FLOOR 36"x30" TO UPPER 30" OF LOUVER FOR EF-3 AND ERV-3 EA 10"Ø 3 9 14 13 11 (3) ZONE CONTROLLERS 14"x11" HWSHWR COVER NO AIRFLOW AREAS WITH SHEET METAL 72"x34"x34" 60"x34"x34" EA-2 12"x24" 120 CFM 20"x20" UP BETWEEN JOISTS 24"x20" UP TO BETWEEN JOISTS 1" 1/2" 1" 1" 1" 3/4" M M 15 151634"x40" OA DOWN 32"x40" EA UP 32"x24" 10"Ø SLEEVE AROUND COLUMN SEALED TO WALLS OF PLENUM. INSULATE SLEEVE WITH 2" THICK DUCT WRAP. AIR INTAKE >10FT EAST OF IR-1 COMBUSTION EXHAUST BELOW NO FLEXIBLE DUCT SHALL BE USED AS PART OF FR-3 AND ERV-3 SYSTEM. ALL BRANCH DUCTS TO GRILLES AND DIFFUSERS ASSOCIATED WITH FR-3 AND ERV-3 SHALL BE GALVANIZED SHEET METAL OF NO LESS THAN 26 GAGE THICKNESS. 7"Ø 6"Ø 9"Ø 10"Ø 7"Ø RA NO FLEXIBLE DUCT SHALL BE USED ABOVE OFFICES 203, 204, 205 AND FLEX 206. ALL BRANCH DUCTS TO GRILLES AND DIFFUSERS SHALL BE GALVANIZED SHEET METAL OF NO LESS THAN 26 GAGE THICKNESS. 7"Ø 6 6 14"x9" OD, 12"x7" ID DUCTBOARD SOUND ELBOW IN WALL ABOVE CEILING 18" 6 KEYED NOTES 1.12"Ø EA THROUGH FLOOR BELOW. 2.12"Ø OA THROUGH FLOOR BELOW. 3.6"Ø EA FROM TOILET 208 TO ERV-1 RA INLET. 4.20"x18" EA ABOVE 20"x18" OA SERVING FR-1. 5.20"x18" EA ABOVE 20"x18" OA SERVING FR-3. 6.20"x18" OA SERVING FR-2. 7.20"x18" EA SERVING FR-2. 8.12"x9" FRESH AIR FROM ERV-1 THROUGH HC-1 AND UP TO 11'-6" AFF. 9.10"Ø EA FROM ERV-1 TO EA MAIN. 10.3/4" HWS AND HWR DOWN THROUGH FLOOR. 11.HANG FROM JOISTS WITH RODS AT FOUR CORNERS. INCLUDE B-LINE CHSCS SERIES ISOLATORS AND STRUT BRACING TO STRUCTURE IN NORTH-SOUTH AND EAST-WEST DIRECTIONS. 12.SUPPORT WITH FOUR B-LINE SERIES RM-D NEOPRENE MOUNTS ANCHORED TO ERV AND FLOOR. 13.10"Ø RA TO ERV-1. 14.10"Ø OA TO ERV-1. 15.12"Ø BYPASS DAMPER. 16.40"x18" EA ABOVE AND 40"x18" OA BELOW.M102 UPPER LEVEL MECHANICAL PLAN DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing PR#020 02/27/20194 PR#025 04/11/20195 RFI#130 05/01/20196 Per RFI-124 FCI suggests roughing in for a destratification fan to be hung from structure at the second level above Lobby 101, so if in the event AAD would like to have a destratification installed in the future, the installation of the fan would be less intrusive. Additionally the conduit and j-box that would serve this fan could be painted during the current project and would not stand out or have to be painted if in fact a fan was added in the future. This rough-in location for a future destratification fan in the lobby is acceptable. Per RFI-131 It was confirmed that the combustion air and combustion exhaust piping cannot be routed through the roof due to snow accumulation. Per the installation instructions the piping length is an acceptable length for the given furnace. The piping must have downward slope toward the furnace in order to return condensate to the furnace or indoor disposal. If condensate discharfes from the piping the snorkel option shown in the installation instructions will be nevessary RE: RFI-168. Per RFI-168 the duct shown on the drawings will be removed and a 6" duct will penetrate the west wall and transition to a 12" above the Uniform Lockers ceiling. 08/13/2019 MECHANICAL SITE PLAN SNOW MELT MANIFOLDS AND ENCLOSURE FOR (11) LOOPS (#1 - #11) 0'16' 8' 2" SWS AND SWR PRE- INSULATED hePEX TUBING AT 24" BELOW FINISHED GRADE CABLE TO SNOW MELT CONTROLLER IN MECH 223 SNOW / ICE / TEMPERATURE SENSOR 3/4" hePEX TUBING SPACED AT 9" O.C. ENCLOSURE WITH SNOW MELT MANIFOLDS FOR (10) LOOPS (#12 - #21) AND 2" BALL VALVES ON SWS AND SWR TO MANIFOLDS FOR LOOPS #1 - #11 LOOP #1 LOOP #21 SNOW TUBING MELT LOOPS I.D.LENGTH, FT.FLOW, GPM 1 284 2.31 2 283 2.30 3 248 2.02 4 239 1.94 5 233 1.89 6 230 1.87 7 227 1.85 8 226 1.84 9 225 1.83 10 225 1.83 11 225 1.83 12 210 1.71 13 208 1.69 14 206 1.67 15 204 1.66 16 202 1.64 17 201 1.63 18 202 1.64 19 204 1.66 20 206 1.67 21 207 1.68 EMBED TUBING IN CONCRETE UNDER TRENCH DRAIN. RE: CIVIL 290' LOOP #22 290' LOOP #23 ENCLOSURE WITH SNOW MELT MANIFOLDS FOR (2) LOOPS (#22 AND #23) AND 1" BALL VALVES ON SWS AND SWR TO MANIFOLDS. ALIGN SE CORNER WITH END OF WALL. 1" SWS AND SWR PRE- INSULATED hePEX TUBING AT 24" BELOW FINISHED GRADE LOOPS #1 - #11 SHALL BE NORTH OF PROPERTY LINE AND LOOPS #12 - #21 SHALL BE SOUTH OF PROPERTY LINE 2" SWS AND SWR PRE- INSULATED hePEX TUBING AT 24" BELOW FINISHED GRADE 20"x30" 18"x20" FR-3 WAFFLE PAD AT EACH CORNER, MASON SUPER W DX COIL DX COIL DX COIL FR-1 30"x30"x2" FILTER 30"x30"x2" FILTER 30"x30"x2" FILTER FR-2 20"x30" 20"x30" RA 21"x22" 20"x25" WAFFLE PAD AT EACH CORNER, MASON SUPER W 20"x25" 18"x22" MA 20"x20" SA AND RA FURNACE SYSTEMS NORTH ELEVATION 0'8' 4' 20"x18" OA 20"x18" EA 20"x18" EA 20"x18" OA 20"x18" EA 20"x18" OA TRANSITION 16"x25"16"x25" RA DUCT FOR FR-3 NOT SHOWN 14"Ø RA TRANSITION 1243 0 EA FARA OA ANCHOR FURNACE TO WALL STUDS WITH STRUT AND B-LINE SERIES RM NEOPRENE MOUNTS EA MAIN FR-1 1243 0 ANCHOR FURNACE TO WALL STUDS WITH STRUT AND B-LINE SERIES RM NEOPRENE MOUNTS FR-2 1243 0 ANCHOR FURNACE TO WALL STUDS WITH STRUT AND B-LINE SERIES RM NEOPRENE MOUNTS FR-3 OA MAIN M201 MECHANICAL SITE PLAN, SECTIONS, AND ELEVATIONS DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing FR-1 SYSTEM SECTION FR-2 SYSTEM SECTION FR-3 SYSTEM SECTION 0'8' 4' 0'8' 4' 0'8' 4' 2/27/2019 CHANGES COMPILED FOR BUILDING DEPARTMENT- Revised per ASI-005 Revised per PR-005 08/13/2019 BOILER PIPING DETAIL NO SCALE PRESSURE GAUGE THERMOMETER AIR SEPARATOR WITH VENT VIBRATION ISOLATOR 1" HWS 1" HWR 1" HWS 1" HWS GAS RELIEF VALVE, PIPE TO FLOOR DRAIN P-T PORT FAN COIL MOUNTING DETAIL NO SCALE FAN COIL CONDENSATE DRAIN PIPING WITH TRAP AND CLEANOUT FITTING FOR UNITS WITH COOLING COIL VIBRATION ISOLATORS AND THREADED RODS FLEXIBLE DUCT CONNECTION ON SUPPLY AND RETURN CONNECTIONS IN-LINE PUMP DETAIL NO SCALE SHUTOFF VALVE STRAINER SHUTOFF VALVE PRESSURE GAUGE FLEXIBLE PIPE CONNECTION FLEXIBLE PIPE CONNECTION CHECK VALVE PUMP PIPE SUPPORT PIPE SUPPORT SUPPORT PUMP UNDER CENTER OF GRAVITY DUCT MAIN HARD ROUND DUCT HARD ELBOW (TYPICAL) CEILING GRILLE INSTALLATION DETAIL BRANCH RETURN DUCT AND NO SCALE CEILING 1" DUCTBOARD BOX OR SHEETMETAL PLENUM WITH DUCTLINER FLEX DUCT, < 3 FT LONG CEILING GRILLE PAINT INTERIOR FLAT BLACK SPIRAL DUCT AND SUPPORT DETAIL NO SCALE THREADED ROD ANCHORED TO STRUCTURE ABOVE, < 12" LONG. NUTS AND WASHERS ABOVE AND BELOW BAND GALVANIZED STEEL BAND ENCIRCLING DUCT SUPPLY DUCT, ROUND SPIRAL 1 1/2" CEILING DIFFUSER OR REGISTER FLEX DUCT, MAXIMUM 3 FT LONG HARD ELBOW HARD ROUND DUCT DUCT MAIN SPIN-IN FITTING WITH BALANCING DAMPER BRANCH SUPPLY DUCT INSTALLATION DETAIL NO SCALE BRANCH SUPPLY DUCT INSTALLATION DETAIL HARD ROUND DUCT HARD ELBOW FLEX DUCT, MAXIMUM 3 FT LONG DIFFUSER OR REGISTER CEILING NO SCALE FC-1, HC-1, HC-2, AND HC-3 HEATING COIL NO SCALE MIXING VALVE PIPING SCHEMATIC OUTLET INLETHWS HWR C NC NO HEATING COIL P-T PORT (TYPICAL) CALIBRATED BALANCING VALVE MANUAL AIR VENTCONTROL VALVE BYPASS VALVE WITH MEMORY STOP SNOW MELT BOILER PIPING DETAIL NO SCALE PRESSURE GAUGE HOUSEKEEPING PAD THERMOMETER 1-1/4" VIBRATION ISOLATOR PUMP GAS RELIEF VALVE, PIPE TO FLOOR DRAIN P-T PORT (TYP) 2" SWR 2" SWS TO AND SWR FROM SNOW MELT TUBING MANIFOLDS 1/2" FPT FOR TEMPERATURE SENSOR WELL (TYP) PC-1 T T T SLAB MOISTURE AND TEMPERATURE SENSOR ET-1 EXPANSION TANK 2" SWS 2" 2" 2" 2"2" PC-2 T PROPYLENE GLYCOL SOLUTION FEEDER SYSTEM 1/2" AS-1 PC-3 PC-4 ET-2 EXPANSION TANK BL-2 <12" AS-2 DIVERTING VALVE PIPING SCHEMATIC CH-1 HEATING COIL NO SCALE OUTLET INLET HWS HWR C NC NO HEATING COIL BALANCING VALVE P-T PORT (TYP.) BOILER PRIMARY LOOP PIPING SHALL BE COPPER PROPYLENE GLYCOL SOLUTION FEEDER SYSTEM 1/2" AS-2 AIR SEPARATOR WITH VENT NOTE: THIS DETAIL IS ONLY FOR SNOWMELT TUBING INSTALLATION AND IS NOT INTENDED TO INDICATE SLAB CONSTRUCTION DETAILS. WIRE TIES TO MESH OR REBAR OR PLASTIC STAPLES INTO INSULATION NO SCALE TUBINGCONCRETE SLAB SLAB INSULATION BASE MATERIAL UNDERSLAB INSULATION DETAIL SNOWMELT TUBING WITH EDGE INSULATION NO SCALE IN RECESSED ENCLOSURE DETAIL SNOWMELT MANIFOLD SWIVEL FITTING AT ATTACHMENT TO BUILDING STRUCTURE ATTACH TO BUILDING STRUCTURE DUCT SUPPORT STRAPS < 12" LONG ATTACHED TO STRUCTURE ABOVE DUCT SUPPORT STRAPS < 12" LONG ATTACHED TO STRUCTURE ABOVE DUCT SUPPORT STRAPS < 12" LONG ATTACHED TO STRUCTURE ABOVE CROSS BRACE IN TWO DIRECTIONS CONTROL VALVE C-TYPE BEAM CLAMPS AND LARGE FLANGE CLAMPS SHALL BE EQUIPPED WITH RESTRAINING STRAPS. C-TYPE BEAM CLAMPS AND LARGE FLANGE CLAMPS SHALL BE EQUIPPED WITH RESTRAINING STRAPS. 1" HWS SF-2 SF-1 BL-1 BYPASS VALVE WITH MEMORY STOP DUCT MAIN SPIN-IN FITTING WITH BALANCING DAMPER DUCT MAIN HARD ELBOW (TYPICAL) AND CEILING GRILLE INSTALLATION DETAIL FR-3/ERV-3 SYSTEM RA AND EA BRANCH DUCT NO SCALE CEILING SHEETMETAL PLENUM WITH DUCTLINER SHEET METAL DUCT 26 GAGE OR HEAVIER PAINT INTERIOR FLAT BLACK CEILING DIFFUSER OR REGISTER HARD ELBOW DUCT MAIN SPIN-IN FITTING WITH BALANCING DAMPER FR-3/ERV-3 SYSTEM BRANCH SA DUCT INSTALLATION DETAIL NO SCALE DUCT SUPPORT STRAPS < 12" LONG ATTACHED TO STRUCTURE ABOVE DUCT SUPPORT STRAPS < 12" LONG ATTACHED TO STRUCTURE ABOVE SHEET METAL DUCT 26 GAGE OR HEAVIER RETURN OR EXHAUST CEILING GRILLE 5 STRUT ANCHORED TO JOISTS TUBULAR INFRARED HEATER HANGER PROVIDED WITH HEATER THREAEDED EYE BOLT WITH NUTS ABOVE AND BELOW STRUT STRUT ANCHORED TO JOISTS TUBULAR INFRARED HEATER HANGER PROVIDED WITH HEATER #2 CHAIN (TYP) 45° SNAP HOOKS (TYP) HANGER PROVIDED WITH HEATER #2 CHAIN ATTACHED TO CENTER OF HEATER HANGER (TYP) SNAP HOOKS AT BOTH ENDS (TYP) BOTTOM CHORD OF JOIST TUBULAR INFRARED HEATER DIAGONAL BRACING TYPICAL FOR SUPPORTS AT FOUR END HANGERS STRUT ANCHORED TO JOIST IR-2 AND IR-3 INFRARED SCALE: 1/2" = 1'-0" IR-1 INFRARED HEATER SUPPORT DETAIL SOUTH ELEVATION WEST ELEVATION SCALE: 1/2" = 1'-0" HEATER SUPPORT DETAIL SOUTH ELEVATION 45° EXPANSION JOINT TUBING HEATED OUTDOOR SLAB BASE MATERIAL REINFORCING MESH OR REBAR SNOWMELT TUBING INSTALLATION AND EXPANSION JOINT INTERFACE DETAIL NO SCALE WIRE TIES TO MESH OR REBAR OR PLASTIC STAPLES INTO INSULATION NOTE: THIS DETAIL IS ONLY FOR SNOWMELT TUBING INSTALLATION AND IS NOT INTENDED TO INDICATE SLAB CONSTRUCTION DETAILS. LEGEND FOR CONTROLS DIAGRAMS FOAM INSULATION, R10 RETURN MANIFOLD WITH LOOP BALANCING VALVES, LOOP ISOLATION VALVES, DRAIN AND VENT VALVE SUPPLY MANIFOLD WITH LOOP ISOLATION VALVES, DRAIN AND VENT VALVE SWR TO BUILDING SWS FROM BUILDING IRRIGATION VALVE BOX AND LID PER SPECIFICATIONS. SET IN GROUND WITH RIM 1" ABOVE ADJACENT FINAL GRADE. TUBING PENETRATING SIDE OF BOX SWS AND SWR WITH BALL VALVES AND PIPING TO NORTH MANIFOLDS. M301 MECHANICAL DETAILS DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing PR#025 04/11/20195 08/13/2019 T PT HL FM T DM H FR TEMPERATURE SENSOR PROBE IN THERMAL WELL TEMPERATURE SENSOR PROBE CENTRIFUGAL PUMP DIFFERENTIAL PRESSURE TRANSMITTER 3-WAY BALL VALVE AND ACTUATOR AIR FILTER AIR FLOW MEASUREMENT STATION CENTRIFUGAL FAN DAMPER AND ACTUATOR 2-WAY BALL VALVE AND ACTUATOR HEATING OR COOLING COIL, FR = FURNACE, DX = DX COOLING COIL LEGEND FOR CONTROLS DIAGRAMS VFDVARIABLE FREQUENCY DRIVE AI DDC I/O (AI = ANALOG INPUT, AO = ANALOG OUTPUT, BI = BINARY INPUT, BO = BINARY OUTPUT) CURRENT SENSING SWITCHCSS T TEMPERATURE CONTROLLER WALL MOUNTEDCO2CARBON DIOXIDE TRANSMITTER - WALL MOUNTED OCCUPANCY SENSOR C CARBON DIOXIDE SENSOR - DUCT MOUNTED MC MAGNETIC MOTOR CONTACTOR MS MAGNETIC MOTOR STARTER SC SOLID STATE SPEED CONTROL, LINE VOLTAGEHFRRA TO EA MAIN DUCT NO SCALE FURNACE AND CONDENSING UNIT CONTROL DIAGRAM T EA DUCT SMOKE DETECTOR FROM OA MAIN DUCT OA TAI DM CDXEA VENTILATION AIR TO ZONES OA RA NO SCALE ENERGY RECOVERY VENTILATOR CONTROL DIAGRAM DM DM EF SF CONTROL WITH FANS HX NO SCALE INFRARED HEATER CONTROL DIAGRAM IR HEATER T NO SCALE FC-1 AND KH-1 CONTROL DIAGRAM SW SC H WTR SAFROM OA MAIN OA DM T AI SC FC-1 KH-1 EF T AI MC BO PC-2 PC-1 T AI T MOISTURE AND TEMPERATURE SENSOR, EMBEDDED IN SLAB NO SCALE SNOW MELT SYSTEM CONTROL DIAGRAM BL-1 BOILER FACTORY BOILER CONTROLS MC SF-1 FEEDER LOW PRESSURE CONTACTS T BOILER HWS SENSOR B0 FIRE ENABLE T PC-3 NO SCALE HYDRONIC HEATING SYSTEM CONTROL DIAGRAM BL-2 BOILER FACTORY BOILER CONTROLS MC SF-2 FEEDER LOW PRESSURE CONTACTS T BOILER HWS SENSOR SC-1 SNOW MELT CONTROLLER MATAI TAITAI TO ECONOMIZER CONTROL MODULE TO ZONE CONTROLLER TO ZONE CONTROLLER FROM ECONOMIZER CONTROL MODULE AO FAN CONTROL FROM ZONE CONTROLLER TO ECONOMIZER CONTROL MODULE BO BO HEAT STAGES FROM ZONE CONTROLLER BO BO BOCOOL STAGES FROM ECONOMIZER CONTROL MODULE CONDENSING UNIT BO BOCOOL STAGES FROM ZONE CONTROLLER ECONOMIZER CONTROL MODULE SA DMFURNACE ZONE CONTROLLER DM THERMOSTAT, ONE PER ZONE DAMPER, ONE PER ZONE BYPASS DAMPER STATIC PRESSURE CONTROLLER TIME CLOCK HWS CONTROL WITH FANS HWR PC-4 BOILER HWR SENSOR MC AUTOMATIC ALTERNATING PUMP CONTROL STARTER? STARTER? FROM SC-1 TO SC-1 TO SC-1 AO FIRE MODULATION FROM SC-1 FROM SC-1 M401 CONTROLS DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing 08/13/2019 >10'-0" A B C D E H I J 1 2 4 5 6 7 LOBBY 101 WOMEN 102 MEN 103 TRAINING ROOM 104 ELEC. 105 APPARATUS BAY #1 106 APPARATUS BAY #2 107APPARATUS BAY #3 108 APPARATUS BAY #4 109 APPARATUS BAY #5 110 APPARATUS BAY #6 111 DECON 112 READY ROOM 113 MEDICAL STORAGE 114 FITNESS 115 STAIR 302 ELEVATOR 301 STAIR 303 3 STORAGE 116 F 0 G GROUND LEVEL PLUMBING PLAN IR-3 FIRE SPRINKLER MAIN RISER MAIN WATER SERVICE LV-1 LV-1 FD-1 2" WC-1 WC-1 FD-1 2" SK-1 MS-1 SK-2 TD-1 L=20'-0' TD-1 L=20'-0' TD-1 L=20'-0' TD-1 L=20'-0" TD-1 L=13'-4" TD-1 L=13'-4" SO-1 BELOW GRADE (3) 2" V. COMBINE AT 6" AFF. 4" W FROM ABOVE ES-1 FD-2 2" GAS METER. CONNECTED LOAD = 2442 MBH (SEA LEVEL). SERVICE PRESSURE = 2 PSIG SK-4 HB-2 60" AFF HB-1 18" AFF HB-1 18" AFF 6" FIRE AND DOMESTIC WATER MAIN. INSTALL THRUST BLOCKS AS DESCRIBED IN CIVIL DOCUMENTS. RE: CIVIL FOR CONTINUATION SP-1 4" BUILDING SEWER. RE: CIVIL FOR CONTINUATION GGGGGGG 1/2" GAS UP THROUGH FLOOR ABOVE 3/4" (2 PSIG) GAS UP THROUGH FLOOR ABOVE 3/4" LOW PRESSURE GAS UP THROUGH FLOOR 1" HW AND 1-1/4" CW UP THROUGH FLOOR ABOVE 1/2" 2 PSIG GAS ABOVE SLAB TO GENERATOR. PROVIDE BALL VALVE AND PRV. INSTALL VALVES AND GAS LINE ACCESSORIES PROVIDED WITH GENERATOR. 0'8' 4' FD-2 2" 1/4" HW UP THROUGH FLOOR ABOVE FS-1 3" 2" W BELOW FLOOR SP-1 INDIRECT TO FS-1 2-1/2" CV, 3" WCO 3" 2-1/2" CV 4" 3"3" 3"3"3"3" 3" 3" SEWER. RE: CIVIL FOR CONTINUATION 2-WAY COTG 2" CV, 2" WCO G G 2" 3/4" 1-1/2" 1-1/4"1-1/4" 1/2" THROUGH FLOOR ABOVE 1/2" 1-1/4" CW UP THROUGH FLOOR ABOVE 3" W FROM ABOVE, 4" WCO 1-1/2" 2-1/2" 2-1/2" V UP THROUGH FLOOR ABOVE WHA, PDI SIZE A WHA, PDI SIZE B 1-1/4" 3" 3/4" GAS UP THROUGH FLOOR ABOVE IR-1 IR-2 2" 3/4" HWC UP THROUGH FLOOR ABOVE 3/4" 1" 3/4" RDL RDL RDL RDL RDLRDLRDLRDLRDLRDL3" 3" RDL FROM DECK DRAIN ABOVE (TYP OF 6) 3" 3" 3" RDL BELOW FLOOR 3" RDL TO UNDERGROUND STORM SEWER. RE: CIVIL FOR DEPTH AND CONTINUATION. 2" 3" RDL DOWN IN WALL 1/4"1/4" 1-1/2" INSTALL ES-1 MIXING VALVE ON WALL AT 8'-0" AFF 2" 1-1/2" 2" V UP THROUGH FLOOR ABOVE 1-1/2" 2"COMBINATION WASTE AND VENT SYSTEM 2" CV, 4" WCO 1-1/2" W AND V, 1-1/2" WCO 2" CO 4"4" WCO FIRE DEPT. CONN.G3/4" (2 PSIG) 1/2" (2 PSIG) BALL VALVE, PRV, AND TEES (TYPICAL AT ALL PRV LOCATIONS) 3/4" (2 PSIG) 3/4" (2 PSIG) G 3/4" (2 PSIG)1/2" (2 PSIG) 1/2" (2 PSIG) 1-1/4" (2 PSIG) 1/2" (2 PSIG)1/2" (2 PSIG) BALL VALVES AT 8'-0" AFF ON HW AND CW TO HB-2 1-1/4" (2 PSIG) 1/2" (2 PSIG) 1/2" (2 PSIG) (2) 3/4" IRRIGATION SUPPLIES. RE: LANDSCAPE DRAWINGS FOR DEPTH AND CONTINUATION.2" MINIMUM COVER 5 FT. 6' 6" PIPE THROUGH FLOOR EWC-1 WATER FILTER GLASS FILLER HR-1 80" AFF FFFF FFFFFF1/2" THROUGH FLOOR ABOVE 1/2" 1/2" 3/4" F 1/2" THROUGH FLOOR ABOVE HB-2 60" AFF HR-1 80" AFF 1/2" GAS UP THROUGH FLOOR ABOVE TO OUTDOOR GRILLE AND GAS SOLENOID VALVE WITH 3/4" ORIFACE AND 1/2" CONNECTIONS CONTROLLED BY ALERTING SYSTEM 1/2" GAS UP THROUGH FLOOR ABOVE TO RANGE AND GAS SOLENOID VALVE WITH 3/4" ORIFACE AND 1/2" CONNECTIONS CONTROLLED BY ALERTING SYSTEM 3/4" 3/4"1" G G PIPE PRV VENT TO ABOVE MAXIMUM SNOW LEVEL MANHOLES FLUSH WITH FINISHED GRADE 3/4" 3/4" (2 PSIG) GENERATOR 3/4" TYPE L COPPER BETWEEN AND THROUGH JOISTS FLEX CONNECTOR BALL VALVE DRAIN AT BASE OF CA 3/4" RISERAIR COMP FEMALE QUICK CONNECT ON WALL AT 8'-0" AFF CA DROP TO QUICK CONNECT, RE: DETAIL 1 / P301 1/2" TYPE L COPPER THROUGH JOISTS 1/2" TYPE L COPPER THROUGH JOISTS 3/4" TYPE L COPPER THROUGH JOISTS CA CA CA CA CA CA CA CA CA CA CACAREEL WITH 100' CA HOSE AT 80" AFF, REELCRAFT MODEL 81100 OLP OR EQUIVALENT. FEED FROM 1/2" CA DROP WITH BALL VALVE. 6 CA DROP TO QUICK CONNECT, RE: DETAIL 1 / P301 CA DROP TO QUICK CONNECT, RE: DETAIL 1 / P301 TEE TO FEMALE QUICK CONNECTOR TEE TO FEMALE QUICK CONNECTOR GENERAL NOTES APPLICABLE TO ALL PLUMBING PLANS THE MECHANICAL CONTENT OF THIS DRAWING IS DIAGRAMMATIC AND NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO LOCATIONS OF DUCTWORK, EQUIPMENT, PIPING, AND SUPPORTS IN ORDER TO COORDINATE WITH BUILDING CONSTRUCTION AND WORK OF OTHER TRADES. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FLOOR DRAIN, FLOOR SINK, AND TRENCH DRAIN DIMENSIONED LOCATIONS. INSTALL BALL VALVES ON WATER SUPPLY TO ALL HOSE BIBS AND WALL HYDRANTS. REFER TO SCHEDULES AND SPECIFICATIONS FOR EQUIPMENT AND MATERIALS OF CONSTRUCTION. JOINTS IN COMPRESSED AIR (CA) PIPING SYSTEM SHALL BE SOLDERED OR THREADED.6 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing P101 GROUND LEVEL PLUMBING PLAN 17 PR#021 3/11/2019 6 RFI 119 5/01/2019 Per RFI-077 (1) HB-1 to be added in this location as shown on A201. 08/13/2019 A B C D E H I J 1 2 4 5 6 7 WAITING 201 OFFICE 203 OFFICE 204 OFFICE 205 FLEX 206 MECH/ELEC 209 CORRIDOR 210 STOR. 213 OFFICE 212 CONFERENCE 214 LIBRARY / REPORTS 215 CORRIDOR 220 UNIFORM LOCKERS 221 LAUNDRY 222 CORRIDOR 224 SHOWER 225 SHOWER 226 SHOWER 227 BUNK RM 229 BUNK RM 230 BUNK RM 231 BUNK RM 232 STORAGE 228 3 TOILET 208 IT 211 DINING 217 DAYROOM 216 KITCHEN 218 MECH 223 F PANTRY 219 STAIR 303 STAIR 302 ELEVATOR 301 0 G DECK 233 UPPER LEVEL PLUMBING PLAN FR-1FR-2FR-3 WC-2 SH-1 LV-2 WC-2 SH-1 LV-2 WC-2 SH-2 LV-2 WB-1 32" AFF SK-3 WC-3 LV-3 4" W MAIN DOWN TO GROUND LEVEL FS-1 2" FD-2 2" HB-1 18" AFF RANGE FD-1 2" 2-1/2" CV 1-1/2" V CONNECT HW AND W FOR DISHWASHER 2" COMBINATION DRAIN AND VENT 2" V AND 3" WCO3" 1/2" GAS FROM BELOW CW TO HB-1 WITH BALL VALVE BELOW SINK 1/2" GAS FROM BELOW WB-3 32" AFF DRYER WASHER 1/2" HW AND CW FROM BELOW 1/4" HW FROM BELOW 1-1/4" CW AND 1" HW FROM BELOW WB-2 WB-2 WB-3 AT 8" AFF 2" CV, 2" WCO 1-1/2" V 0'8' 4' SK-4 3/4" GAS FROM BELOW BL-2 1-1/4"1" 3/4" MS-1 1" 1" 3" 3" 3" W DOWN 3" VTR 2-1/2" V FROM BELOW UP TO 3" VTR 1/4" CW 1-1/4" CW FROM BELOW 3" 2-1/2" FROM CV FD-1 2" WH-1 WH-2 G BL-1 G 3/4" HWC FROM BELOW CP-1 GAS FROM BELOW 1-1/4" 3/4" DD-1 3" DD-1 3" DD-1 3" DD-1 3" DD-1 3" DD-1 3" WATER HEATER CONCENTRIC VENT FITTING AT 14'-0" AFF (TYP OF 2). INSULATE INDOOR COMBUSTION AIR PIPING. 2-1/2" 2-1/2" 2" V FROM BELOW 2" 3" WCO CO UNDER SINK 2" CV, 3" WCO GAS GRILLE BALL VALVE AND QUICK CONNECT AT 18" AFF 3/4"1/2" G G 3/4" GAS FROM BELOW 3/4" 1/2" GAS AND PRV FOR BL-2 SK-5 PIPE CONDENSATE DRAINS FROM FURNACES AND DX COILS TO FLOOR SINK GLASS FILLER WB-2 ℄ 41" AFF ℄ 41" AFF ℄ 41" AFF 1/2" FILTERED CW FROM BELOW 1/2" FILTERED CW FROM BELOW 1/4" 1-1/2" 2" 1/2"1/2" P102 UPPER LEVEL PLUMBING PLAN DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing CONDENSATE PIPING CHANGED TO WC-3 PER PR-017. Per RFI-072 LV-1 sink to be used in 208. RE: RFI-102. RFI-102 clarifies WB-1 & WB-3 RE: RFI-151. Per RFI-151 the shower enclosure will be deleted and the walls will be T2-4 and the floor will be tile T-1. RE: RFI-153. Per RFI-153 the water heater vents are to penetrate the west wall of the building at 10' AFF (Upper Floor) 08/13/2019 A B C D E H I J 1 2 4 5 6 7 3 F 0 G ROOF PLUMBING PLAN 0'8' 4' 3" VTR 3" VTR P103 ROOF PLUMBING PLAN DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N C 2016 CHAMBERLIN ARCHITECTS05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing 08/13/2019 1XP TWO-WAY CLEANOUT TO GRADE DETAIL FINISHED GRADE THREADED CLEANOUT CAP AND CLEANOUT FITTING PIPE OF APPROPRIATE LENGTH TO EXTEND TO HORIZONTAL PIPING BELOW HORIZONTAL WASTE PIPING REQUIRING CLEANOUT WHERE CLEANOUT IS NOT INSTALLED IN CONCRETE BY OTHERS, PROVIDE SQUARE CONCRETE PAD CLEANOUT TO GRADE (C.O.T.G.) DETAIL cotg-detail.dwgNO SCALE FINISHED GRADE THREADED CLEANOUT CAP AND CLEANOUT FITTING PIPE OF APPROPRIATE LENGTH TO EXTEND TO HORIZONTAL PIPING BELOW HORIZONTAL WASTE PIPING REQUIRING CLEANOUT IF CLEANOUT IS AT UPPER END OF LINE, THIS FITTING IS 1/8 BEND INSTEAD OF TEE WHERE CLEANOUT IS NOT INSTALLED IN CONCRETE BY OTHERS, PROVIDE 16" SQUARE CONCRETE PAD DISHWASHER WASTE CONNECTION DETAIL NO SCALE 1 1/2" P-TRAP AND WASTE PIPING dishwasher.dwg DISHWASHER WASTE HOSE INSERTED 2" INTO OPEN STAND-PIPE COUNTER TOP ABOVE DISHWASHER OPEN WYE 8" MINIMUM DISHWASHER WASTE HOSE CLAMPED TO UNDERSIDE OF COUNTER ABOVE FLOOR CLEANOUT (F.C.O.) DETAIL fco-detail.dwgNO SCALE THREADED CLEANOUT CAP, CLEANOUT FITTING, AND ACCESS COVER AS SPECIFIED. COVER SHALL BE FLUSH WITH FINISHED FLOOR. PIPE OF APPROPRIATE LENGTH TO EXTEND TO WASTE PIPING BELOW FINISHED FLOOR PIPING DETAIL gas-water-htr-2.dwgNO SCALE PIPE RELIEF DISCHARGE TO FLOOR DRAIN T & P RELIEF VALVE DIELECTRIC UNIONS AT WATER HEATER CONNECTIONS UNION WATER HEATER 1" HW 3/4" HWC 1" CW GAS SUPPLY PIPING DUAL GAS WATER HEATER DRAIN VALVE, PIPE TO FLOOR DRAIN SAND AND OIL INTERCEPTOR DETAIL ANCHOR PIPING TO GREASE INTERCEPTOR. SEAL PIPE PENETRATIONS. 3" INLET 2" VENTS FINISHED GRADE NOT TO SCALE CAST IRON MANHOLE COVER AND RING, GASKETED, AIR TIGHT AND SECURED WITH 5 SIDED FASTENERS (TYP. OF 2) CLEANOUT GRADE CONCRETE MANHOLE RINGS 3" OUTLET INTERCEPTOR VENTS UP INSIDE BUILDING THROUGH ROOF. COMBINE AT 6" AFF. 6" >18">24" 4"Ø OPENING CLEANOUT VENT OUTSIDE OF MANHOLES, NOT THROUGH LIQUID LEVEL SUMP PUMP DETAIL NO SCALE ALARM FLOAT SUMP PUMP WITH FLOAT SWITCH SUMP BASIN WASTE AND VENT PIPING ROUTED AS SHOWN ON PLAN GAS-TIGHT LID WITH SEALED PENETRATIONS POWER AND ALARM CABLES ELEVATOR PIT FLOOR FLOOR DRAIN WITH RUBBER TRAP SEAL GAS-TIGHT INLET VENT THROUGH ROOF DETAIL NO SCALE ROOF JACK RECOMMENDED BY ROOFING MATERIAL MANUFACTURER OR SPECIFIED BY ARCHITECT. FLASH AND SEAL PER ARCHITECTURAL SPECIFICATIONS. VENT PIPE, MINIMUM OF 3" PIPE SIZE 12" MINIMUM ROOF INSULATE 5 FT LENGTH OF VENT BELOW ROOF WATER SERVICE PIPING DETAIL water-svc-2.dwgNO SCALE PRESSURE GAUGE, 0-200 PSIG PRESSURE GAUGE, 0-100 PSIG 3/4" PRV SET AT 70 PSIG 1-1/4" PRV SET AT 65 PSIG 3/4" 3/4" 1-1/2 2" 2" RPZ BACKFLOW PREVENTER ASSEMBLY. PIPE RELIEF INDIRECT TO FS-1 PVC PIPE SLEEVE AND MECHANICAL SLEEVE SEAL (TYP) 4" WATER METER PROVIDED BY UTILITY CO WALL CLEANOUT (W.C.O.) DETAIL wco-detail.dwgNO SCALE CLEANOUT TEE WITH CLEANOUT PLUG WALL COVER AND SCREW PER SPECIFICATIONS WALL FLOOR WASTE PIPE TO BELOW FLOOR WASTE OR VENT PIPING IF APPLICABLE FIRE SPRINKLER MAIN RISER DEVICES. RE: SPECIFICATIONS FLOOR CLOSED BYPASS VALVE. REMOVE HANDLE. CP-1 ET-3 ACID NEUTRALIZER (TYP) PIPE COMBUSTION CONDENSATE TO FLOOR DRAIN (TYP) CO 1-1/2"1/2" FPT BLOW-OUT 2" TO FIXTURES WH-1 WH-2 3/4" COPPER TO IRRIGATION RE: LANDSCAPE DRAWINGS FOR CONTINUATION AND BACKFLOW PROTECTION WATER METER PROVIDED BY UTILITY CO 3/4" WATER FILTER SERVING EWC-1, DF-1, GLASS FILLERS, COFFEE, AND ICE 3/4" 3/4" AQUASTAT 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" ALUMINUM 3-1/4" DEEP CHANNEL WITHOUT HOLES, B-LINE MODEL B11AL OR EQUIVALENT INFRARED HEATER, NOT PRESENT IN ALL LOCATIONS OPEN SIDE OF CHANNEL FACING SOUTH CONDUIT AND 200°C RATED WIRING DEEP INSIDE CHANNEL FOR ELECTRICAL DROP 1/2" COPPER COMPRESSED AIR PIPING INSIDE CHANNEL WIRING BOX FOR CORD CONNECTION AT 7'-0" AFF COMPRESSED AIR FEMALE 1/4" INDUSTRIAL INTERCHANGE QUICK CONNECT FITTING, AT 6'-8" AFF ANCHOR CHANNEL TO STRUCTURE ABOVE AND CROSS BRACE IN NORTH-SOUTH AND EAST-WEST DIRECTIONS TO PREVENT CONTACT WITH HEATER DETAIL 1 / P301 CA DROP ELEVATION SCALE: 1/2" = 1'-0" CORD FOR BATTERY CHARGER 6 DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing P301 PLUMBING DETAILS 2/27/2019 CHANGES COMPILED FOR BUILDING DEPARTMENT- 6 5/01/2019RFI 119 08/13/2019 MS-1 SK-1 FD-2 SH-1 WC-1 WC-1 FD-1 LV-1 FD-1 LV-1 LV-2 FD-2WC-3 LV-2 SK-3 SH-1 WC-2 LV-2LV-2 SH-1 WC-2FD-1 MS-1 FD-1 SK-4 WB-1 FD-2 SK-4 SK-2 GROUND FLOOR LEVEL UPPER FLOOR LEVEL TD-1 FS-1TD-1TD-1TD-1TD-1TD-1 SO-14"W TO BUILDING SEWER BEYOND FOUNDATION 3" W BEYOND FOUNDATION WC-2 FD-2 SP-1 SOIL, WASTE, AND VENT FLATOMETRIC NO SCALE 2-1/2" CV 2-1/2" 3"VTR 1-1/2"2" CV 2" CV 2-1/2"2-1/2" 2"2" CV 3"VTR 2-1/2" 2"2" CV 1-1/2" 1-1/2"1-1/2"2-1/2" CV 2-1/2" CV 2" 2" 2"4" 11 2"2"4" 4" 3" 4" 4"2"11 4" 4"2"3" 2"3"3"3"3"2"3"2"3"2" 2"2" 11 2"11 2" 11 2"11 2"11 2"11 4"11 4"11 4"11 4"11 2" 11 4"3"3"3"3"3"3" 3" 3" 3" 3" 4" 3" 4" ELEVATOR PIT UPPER FLOOR LEVEL GROUND FLOOR LEVEL 11 2" SP-1 INDIRECT DISCHARGE TO FS-1 3" WCO 1-1/2" WCO 3" WCO 3" WCO 2-WAY COTG4" WCO WCO 4" WCO WCO 4" WCO 4" CO 3" FCO 3" FCO 1-1/4"1-1/4" 3/4" HB-1 1" WC-1 1/4" LV-1 2" MAIN WATER SERVICE 1/4" LV-1 1" WC-1 1/2" SK-2 1" WC-3 1/2" HB-1 1/2" HB-2 1/2" SK-3 1-1/4" 3/4" ES-1 1/2" SK-1 1/2" MS-1 1/2" HB-2 SK-4 1/2" 1/2" WB-1 3/4" HB-1 1/2" SK-4 1/2" MS-1 1/2" BL-1 1/2" LV-2WC-2SH-1LV-2WC-2SH-1WB-2WB-2LV-2WC-2SH-1WH-2WH-1 1-1/4" 1/4" LV-3 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1" 1/4"1/4" 1-1/4"1-1/4"2"1-1/2"1-1/2"1-1/4"1-1/4"3/4"3/4" 3/4"3/4"1-1/4"1-1/4"1"1" COLD WATER FLATOMETRIC NO SCALE GROUND FLOOR LEVELGROUND FLOOR LEVEL UPPER FLOOR LEVELUPPER FLOOR LEVEL 1/2"1/4"1/4" GLASS FILLER AT SK-5WB-1WB-1 1/2" SK-5 1/4" WB-1 1/2"FFF EWC-1 1/2" GLASS FILLER AT SK-2 1/2" 3/4"1/2"FILTER METERED IRRIGATION SUPPLIES 3/4"3/4" 1/2" HB-2 FF3/4" 1/2" 1/2" WB-1 3/4" SK-4MS-1SH-1LV-2SH-1LV-2 1/2" SH-1 1" WH-2 1" WH-1 1/2" SK-31" LV-1LV-1SK-2HB-2 SK-4SK-1ES-1MS-1 1/2" HB-2 1/4" LV-3 LV-2 1/2"3/4"1/2"1/2"1/2"1/2"1/4"1/4" 1/2"1/2"1/2"1/2"1/2"1/2"1/2" CP-1 3/4" 3/4"1"1" 3/4"3/4"3/4"1" HOT WATER FLATOMETRIC NO SCALE GROUND FLOOR LEVELGROUND FLOOR LEVEL UPPER FLOOR LEVELUPPER FLOOR LEVEL HB-2 1/2" 1" 1/2" SK-5 1/2" 3/4" DRAWN BY:CHECKED BY: SHEET NO: PROJECT NO: DATE: CHAMBERLIN ARCHITECTS 437 Main St. Grand Junction, Colorado 81501 T 970.242.6804 725 Saint Joseph St., Suite B1 Rapid City, South Dakota 57701 T 605.355.6804 www.chamberlinarchitects.com E N H A N C I N G E V E R Y D A Y L I V I N G T H R O U G H D E S I G N 05/09/2018 1740 CASTLE CREEK ROAD ASPEN, COLORADO PROJECT STATUS: 100% CD DCR DCR ASPEN AMBULANCE DISTRICT FACILITY NO:ISSUED FOR:DATE: 356 ECHO CANYON COURT, GRAND JUNCTION, CO 81507-9584 PHONE 970-434-9819 / CELL 970-260-1781 / clintral@bresnan.net RALSTON MECHANICAL CONSULTING, LLC Engineering for HVAC, Refrigeration, and Plumbing P401 PLUMBING FLATOMETRICS Per RFI-123 there are only the two HB-2 hose bibs shown on P101. 08/13/2019 Per Pre-Bid Question#58 - The MDPbusses have beenoversized toaccommodate futurephotovoltaic powerinput. The 600 ampmain switch iscorrect.Drawing E001, One Line Diagram: Revise the rating of the feeder to panel ‘LB’ as follows: 1. Change feeder conductor size to 350 MCM copper. 2. Change feeder conduit size to 3”. PR-06 has modified thefeeder to the LB panel.08/13/2019 Per Pre-Bid Question#6 - It is contractorschoice item fortemporary power whereever is more efficient topower parking lot lights,electrical, and new trashenclosure.Per Pre-Bid Question#59 - The PVC sizeis 3/4"Per Pre-Bid Question#60 - The storagebuilding needspower. Circuiting isshown in thedumpster enclosureelectrical plan.Per Pre-Bid Question#61 - An all-in-onemeter/switch isacceptable if it isacceptable to HolyCross. The exact locationon the building will bedetermined prior to thestart of construction.Trash Enclosure layoutupdated per PR-02Per RFI-015 -Electrical disconnectand metering serviceexplained.Per RFI-149 it was confirmedthat the LFL2 light fixture wouldbe deleted and a light would be installed at thetop of the pole to illuminate theflag. The power that was goingto be used for the LFL2 fixture will now be used for theflag pole fixture. Per discussionsduring the OAC meeting, it wasconfirmed that the new light will be the dual light, hardwired option from AmericanBeacon.08/13/2019 508/13/2019 Per RFI-121 Per conversations withthe Owner it was requested that alight switch is to be added withinCorridor 220 near door 303D in order for AAD Staff to be able tocontrol lights from this location aswell, so if they are exiting the stairsat the upper level they are able to exit the stair andimmediately turn on lights if needed.Please confirm this change isacceptable.Per RFI-133 Change the3 type 'LAY3' fixtures totype 'LDL2' in order toprovide better headclearance under the patiocanopy.Per RFI -141 it wasconfirmed that the (3)type F light fixtureswill be deleted and(1) 72" long LAR3light fixture will beadded at thislocation. The LAR3light fixture is to bewall mounted at 7'-0"AFF to the "PortraitWall" per interiorelevation 5 on sheetA405.08/13/2019 Per Pre-bid Question #57 - The Emergencyservice disconnect onthe outside of thebuilding at column 5between lines I and J.Per ASI-004 the power layout forthe north wall has been revised.Please refer to ASI-004.Per RFI-048 the elevator call-out line can be runthrough V.O.I.P. It must have equipment that cancommand the line when required.Per RFI-049, access control is deleted from 105,209, 223. All keypads will be deleted, power transferare verified, door release buttons are verified, REXare verified and door contacts are verified. Pleaserefer to RFI-049.RE: RFI-086. Emergencyphone added to wall.3'-10" AFF.Per RFI-109 Deacon 112 - change outlet on thenorth wall to a quad outlet andchange elevation to 24" AFF.Medical Storage 114 - Relocate theoutlet on the south awall to the northwall and change to a quad outlet.Ready Room 113 - Add a quadoutlet on the north wall of the room.Wire new quad outlet on the northwall in the ready room to panel 'LA'Circuit #13.Training Room 104 - Change themulti-media outlet from the northwall to the south wall.Per RFI-111 - Theemergency switch isto be mounted on theEast wall of the lobbyjust to the south ofwindow BO2.Additionally a volumeswitch is to beinstalled at this samelocation to controlsound level of theceiling mountspeaker for the lobby.RE: RFI-152. Per RFI-152,additional overhead doorcontrol stations will be added inthis location as well as directlynorth of door 101BRE" RFI-164. Per RFI-164 a new camera to beadded to the southwest corner of the canopy facingthe northeast corner. New light fixture to be installedon the north wall.08/13/2019 RE: RFI-090. PerRFI-090 a doorrelease for door 101to be added here.RE: RFI-091. PerRFI-091 (2) receptacleswill be added to the Stair303 upper landing.Per RFI-109 The following changes areacceptable.Storage 213 - Change from a jamb lightswitch to an OCC sensor for light operation. Office 212 - Outlets to be mounted at 70" AFFto be consistent with the other offices. Stair 302 - Move the outlet from the toplanding to the intermediate landingWaiting 201 - Make the card reader to thestorefront mullion from the north wall.Waiting 201 - Relocate the door releasebutton to the wall north of door 201 on thewest side of the door. Flex 206 - Rough-in Flex room for both bunkroom and Office configuration.Storage 228 - Change from a jamb lightswitch to an OCC sensor for light operation.Per RFI -113 In our experience, 75’ isas far as one should be from a WAP. For full coverage on both floors, werecommend transmitters be added at Corridor 207at column intersection 2.5 & G.5 andin Corridor 224 at column intersection2.75 & A.75.Per RFI -114 It is assumed that the Wolfinline blower provided for the hood willinclude a speed control. The speedcontrol shall not be mounted on the hood.The speed control shall be mounted nearthe fan above the ceiling for use by theTest and Balance Contractor to set thefan air flow according to the drawings.The fan speed shall not be useradjustable. The timer switch shall allow the user to select a duration ofoperation for the fan EF-3 and for fan coilFC-1Per RFI -132 It wasconfirmed that the owneragrees with adding thecable tray to the IT roomper the layout attached.FCI will proceed with theaddition of the cable trayper the attached sketch.08/13/2019 08/13/2019 RE: RFI-094. Per RFI-094the alerting systemdoorbell will be deleted.RE: RFI-092. Per RFI-092the video messenger willbe moved to grid B and anew monitor will be addedto grid ERE: RFI-103. PerRFI-103 the alertingsystem to change tobunk room style.Per RFI-115 There are no fire/smoke dampers orsmoke dampers to close so the fire alarm systemdoes not control these. The furnaces are to be shut down in the event thatsmoke is detected in the return air ducts. Thisshut-down can be either hard wired interlock withthe smoke detectors or the fire alarm system canperform the shut-down. The fire alarm system willbe monitoring the smoke detectors. The furnacesmay also be shut down on all the other detectorsthat the fire alarm submittal Sequence ofOperations lists. The fire alarm system isdesign-build so the fire alarm contractor should do whatever is required by code.Per RFI-111 The speakers in commonareas on the upper level are to be onseparate zones to control audible leelsThe volume controls for this speaker areto be accommodated by the amplifier atthe head end equipment if enough outputports are present in the amplifier provided. If there are not enough output ports onthis amplifier volume controls are to berack mounted near the alerting systemhead end within IT 211.Per RFI-111 The volume controlswitch is to be deleted at theoutdoor location. Volume control forthe outdoor speaker is to beprogrammed at the Alerting Systemhead end equipment located withinIT 211. The speaker in this locationis to be ceiling mounted within theT&G canopy. The TAM controllerfor this speaker is to be mounted inCorridor 220 above the ceiling.Per RFI-111 The VMSS monitorin corridor 220 is to be a 32"monitor. Monitors in theapparatus bay are to bemounted at 10'AFF to Center ofmonitor. The turnout Timerslocated within the ApparatusBay are to be installed directlybelow the VMSS monitors.Per RFI-111 The Dorm Remotethat is to be provided in FlexRoom 206 can control volumeoutput for this space. PerRFI-103 a separate volumecontrol switch was to beprovided. Because volume forthe alerting system can be adjusted fromthe dorm remote, the additionalswitch is not required at FlexRoom 206.Per RFI-111 receptacle is shown to belocated in the main electrical room on the 1stfloor which is not consistent with low voltageor alerting system drawings. Perconversation with low voltage systems on site4/11/19, it was confirmed that head endequipment for the alerting system will require3 dedicated circuits. Circuits are to be fedfrom EM panel. 2EA circuits are to beprovided for UPS devices for the AlertingSystem. UPS's for this system will be rackmounted within IT Room 211. The otherreceptacle which is also to be fed from an EMcircuit is for the transformer for the ApplianceController. The Appliance Controller andtransformer will be located within IT 211.08/13/2019 08/13/2019 08/13/2019 1. Drawing E403, Fire Alarm Riser: Move the heat detector in the elevator equipment room to the elevator pit (the location of the elevator controller). PR-07 added the following:1. Distribution panel ‘MDP’: Change the circuit breaker sizes shown for CU-1, CU-2 & CU-3 to 50 amps 2 pole. 2. Panel ‘LA’: Change the circuit breaker size shown for EF-1 from 15 amp 3 pole to 20 amp 2 pole. Per PR-09Per PR-0908/13/2019 08/13/2019 Per PR-07: Add GFCI Tripping to Circuit #251. Change the circuit breaker sizes shown for CU-1, CU-2 & CU-3 to 50 amps 2 pole. 2. Change the circuit breaker size shown for EF-1 from 15 amp 3 pole to 20 amp 2 pole. 3. Change the combination starter listed for EF-1 to a combination disconnect – the motor being suppled has embedded thermal overcurrent protection. Per PR-0908/13/2019