Loading...
HomeMy WebLinkAboutFile Documents.120 Red Mountain Rd.0194.2018 (8).ARBK1 ORTAL Heating Solutions Ltd. INSTALLATION & OPERATION MANUAL The ORTAL direct vent (and ORTAL power vent with separate manual) gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LPG). ANSI Z21.88/CSA 2.33-2014- Vented Gas Fireplace Heaters Standard references: CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace Pictured Above: ORTAL’s Clear 110 TS Patent Pending for screen barrier glass bracket: USSN 60/040,074 Version: February 24, 2015 07/25/2018 2 TABLE OF CONTENTS ORTAL HEATING SOLUTIONS FIREPLACE MANUAL 1.Introduction to Ortal and Company Profile 4 2.Fireplace Safety Information and Warnings 5 3.Product Listing 8 a. Certifications and Codes 8, cover b. Product List: Models and Burners 9 Note: Clear 70 Front/RS/LS/TS/SA will now be termed as Clear 75 4. Fireplace Clearances 10 Front/RS/LS/TS/SA a. Standard clearances 10 Note: TS/LS/RS/SC (pages 10 to 13), Front (pages 14 to 17), Tunnel (page 21) b. Mantel detail 12 c. Shelf detail 24 d. Stand Alone mounting detail 27 (through 37) e. Cold Wall Technology 38 f. TV above fireplace install detail 41 Note: This is for all models/series although the drawing mentions Clear Front g. Double glass air intake detail 47 5. h. Wall support sample detail 50 Gas Information . Routing of Gas Line 52 . Gas Pressure and Power Output 53 Note: Burner 30 (Series 40) page 53, Burner 45 (Series 75) page 54, Burner 100 (Series 110-130) page 55, Burner 135 (Series 150-170) page 56, Burner 160 (Series 60 63 63 64 65 6.Install Vent System (see note 1 on page 103) 66 a.Restrictors & Vent Arrangement 66 b.Schematic Drawing 68 07/25/2018 3 c.Restrictor table per burners 69 d. Vent Installation 74 e. Vent Clearances 74 f. Vent Maintenance 74 g. Vent termination 75 7. Fireplace Installation Instructions and Checklist 77 a. Locating Your Gas Fire Place 78 b. Handling the Glass (see note 3 on page 103) 79 c.Fireplace Barrier (see Appendix C & D) 81 d. Interior Design Media 83 e. Interior Reflective Panel 84 f.Burning Period 85 g. Insulation for Cold Climate 86 8.Operating Instructions and Warnings 87 a.Mertik Electronics Control System (see note 2 on page 103) 87 9.General Maintenance Instruction 88 a. General Maintenance 88 b. Ortal Factory Recommended Service 90 c.Service Log 92 10. Warranty Policy 93 11. Manufacturer and Supplier Contact Information 97 12.Sample Product Certification Labels 98 13.List of Appendices 103 Appendix A – Double burner units, special notes Appendix B – ORTAL USA Trouble Shooting Guide Appendix C – Screen Instructions for Front & Tunnel models Appendix D – Screen Instructions for Multi-sided models NOTE: Diagrams and illustrations are not to scale. (Clearance diagrams). All fireplace drawings with dimensions are available on our website under Products>Downloads>Diagram 07/25/2018 4 INTRODUCTION Company Profile Welcome to ORTAL and ORTAL USA. ORTAL, providing heating solutions for over 25 years, is well known for its wide selection of modern gas fireplaces, produced with close attention to detail, finishing, heating efficiency and quality. ORTAL’s products combine traditional and modern design with the technology innovation that ensures a green product with high efficiency ratings. Our advanced technology produces eye catching fires that are safe, beautiful and economical. Our product sophistication allows installation in more locations inside the home. ORTAL offers the largest selection of modern gas fireplaces in North America available in an array of sizes to suit design and architectural needs integrating heat into the aesthetics of life. ORTAL also welcomes clients’ visions for custom-made fireplaces for special requirements, sizes and uses. Our high quality fireplaces are CSA and CE certified. ORTAL fireplaces are available in North American through ORTAL USA approved dealers who each have a strong commitment to offer the best installation and service. Green Statement: ORTAL offers a green, environmentally friendly heating solution for the modern era. With ORTAL’s high efficiency ratings and contemporary designs, you don’t have to sacrifice form for function. The unique design maximizes the fireplace’s radiant heat. Additional efficient components include ORTAL’s use of direct vent technology, electronic ignition (instead of a standing pilot) and low maintenance requirements. We appreciate you choosing ORTAL for your fireplace needs. Thank you, 07/25/2018 5 FIREPLACE SAFETY INFORMATION & WARNINGS DANGER The direct vent system appliance must be installed as an OEM installation in manufactured homes (USA only) or an aftermarket permanently located, or a mobile home, where not prohibited by local codes and must be installed in accordance with Manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada. If the information in these instructions are not followed exactly a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Ortal direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance. OWNER: Keep this manual for future reference. 07/25/2018 6 WARNING: Glass Handling The glass must ONLY be removed by an authorized &/or qualified installer. The authorized technician should ONLY remove the glass with the glass vacuum holders supplied by the manufacturer. Lower the glass to rest in a safe place. This is to prevent damage to the glass edges. Step 1. Prepare a safe place for the glass to rest. Step 2. Remove the glass using the vacuum holder. Step 3. The glass can now be rested safely. WARNING: Fireplace Temperature Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Clothing or other flammable material should not be placed on or near the appliance. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddles, young children and other at risk individuals out of the room and away from hot surfaces. WARNING: Screen Barrier A barrier designed to reduce the risk of burns from hot viewing glass is provided with this appliance and shall be installed. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating. DANGER: IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. 07/25/2018 7 MODELS All the models referenced in this manual are equipped with the same basic equipment including: firebox and leg supports, burner, gas valve, glass panels, operation control, special tools, etc. ALL the warnings and instructions apply to ALL the models. WARNING: Electrical Grounding These Direct Vent appliances must be electrically grounded in accordance with the local codes or, in the absence of local codes, with National Electric code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1. WARNING: Gas Appliance This appliance is only for use with the type of gas indicated on the rating plate. These appliances are not convertible for use with other gases, unless a certified kit is used and the conversion is performed by an authorized qualified technician. Applicable standards are Vented Gas fireplace heaters ANSI Z21.88 / CSA 2.33a and gas-fired appliances for use at high altitudes CAN/CGA 2.17-M91. WARNING: Installation and Service Installation and repairs must be done by an authorized qualified installer service agency or gas supplier. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control apartments, burners and circulating air passageways of the appliance be kept clean. Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the manufacturer. In the case of models supplied with a door fitted in the frame of the heater, ONLY an authorized qualified installer may open this door. The end user must NOT open the door, as this may be unsafe and may result in voiding the manufacturer’s warranty. 07/25/2018 8 PRODUCT LISTING Certifications and Codes The appliance has been certified for use with either natural gas (NG) or propane gas (LP), and NOT for use with solid fuels. These gas fireplace appliances are CSA certified and approved for indoor use and can be specialized with certain requirements for indoor outdoor use (i.e. tunnel models). For indoor installation they must be installed maintaining required clearances. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliance is not approved for closet installation. The appliance must be installed according to ORTAL and ORTAL USA requirements in addition to any local codes that may apply. If none exist then the current CSA installation code must be followed: •USA, ANSI Z223.1/NFPA 54 •Canada, CSA B149 The appliance must be properly connected to an M&G DuraVent chimney venting system. Refer to the specific appliance to determine vent size and pathway requirements. 1.Consult the authority having jurisdiction to determine the need for a permit PRIOR to starting the installation. 2. It is the responsibility of the installer to ensure that this fireplace is installed in compliance with the manufacturer’s instructions and all the applicable codes. 3.Before starting, take careful note of ALL the WARNINGS in this manual. 07/25/2018 9 Product List: Models and Burners Burners and venting for models can be seen in the table below. Adaptors are not required. Burner Models Chimney size 30 (Series 40) • Clear 40/ RS/LS/TS/ Tunnel, •Stand Alone 40 TS • Clear 4070H/RS/LS/TS/Tunnel • Clear 4090H/RS/LS/TS/Tunnel •Small Square, Classic Corner, Modern Corner 4x6 45 (Series 75 & 80) • Clear 60x80/ Tunnel • Clear 75/RS/LS/TS, Stand Alone 75/TS/Hood •Space Creator 75 • Clear 75H TS, Clear 7565/Tunnel • Clear 80/RS/LS/TS, • Clear 8070H/RS/LS/TS • Classic F 75/80 •Island 75 •Clear 100x90 (note: uses 5x8 vent pipe) 4x6 100 (Series 110, 120 & 130) • Clear 110, Clear 110 RS/LS/TS/Tunnel •Stand Alone 110 • Clear 110 H/ Tunnel • Clear 130/RS/LS/TS/Tunnel/Top •Island 130 •Space Creator 120/Mini/Medium 5x8 135 (Series 150 & 170) • Clear 150/H/ RS/LS/TS/Tunnel, •Space Creator 150 •Stand Alone 150 •Clear 170/ RS/LS/TS/ Tunnel 5x8 160 (Series 200) • Clear 200/H/RS/LS/TS/Tunnel, Space Creator 200 • Clear 20070H/RS/LS/TS • Clear 250/RS/LS/TS/Tunnel 5x8 Two Burners • Clear 250/RS/LS/TS/ Tunnel • Clear 350/ RS/LS/TS/ Tunnel • Clear 400/ RS/LS/TS/ Tunnel •4 Glass 2 burners Refer to Appendix A for specific information relating to these Two Burner models. 5x8 07/25/2018 10 FIREPLACE CLEARANCES Minimum Clearances to Combustible Materials Appliance and Vent Clearances The appliance is approved with maintained minimum clearance to combustible materials as shown in the diagrams provided. Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance face so long as it maintains the minimum clearances between the appliance and the non-combustible material. Surrounding material is not allowed to transfer weight to the unit or be connected in any way to the unit. They must not cover any portion of the removable glass panel or the control compartment. The minimum clearances (air space) to combustible materials must be adhered to. It is of the greatest importance that the fireplace and vent system be installed only in accordance with these instructions. “Flat”: walls surrounding finish in the same plane as the fireplace. Definitions: “Offset”: walls surrounding finish in a different plane as the fireplace and there is 90 degree (usually) between the plane of the fireplace and the plane of the wall. Maximum 3” horizontal space between the two planes. Access Panels are typically required for all Ortal fireplaces. They allow for efficient and comfortable access to the fireplace receiver and valves which is required to service the unit(s). Also, access panels can be uniquely placed and designed to not disturb the aesthetic incorporation of the fireplace to its surrounding living space. The size of the Access Panel may vary, but in all cases must allow the fireplace technician to effectively access and service the valve and receiver if required. However, access panels are not the only option for servicing the fireplace operation mechanisms. A technician may also service the fireplace controls by going through the firebox. This procedure requires removing the glass panel(s), taking out the interior design media and lifting the grill, burner and bottom side (explosion valve) of the unit. The technician would then return all these fireplace components when service is complete. 07/25/2018 11 Fireplace dealers/installers are advised to consult with their clients, project architects and/or interior designers regarding the advantages and disadvantages of each service option. Framing and Drywall Fireplace chase may be framed with metal studs or wood studs. If using wood studs they must be covered completely with non-combustible material and have the gaps sealed with a non-combustible fire sealant. We recommend using 5/8” Type X fire rated drywall for the enclosure of the fireplace chase. The framing of the fireplace chase wall must be designed to carry the entire weight of the wall. Plan to include weight of other finish materials placed on the drywall. Heat Release is required for all models with the exception of the Stand Alone. This allows for heat building up within the fireplace chase to be released back into the space which then helps keep the fireplace wall cool. It must be located at the top of the fireplace chase and recommended to be placed a maximum of 6 inches below the fireplace chase ceiling. It can be located on the front, sides or back of the fireplace chase so long as it is being released into an interior space and not outdoors. A minimum air space is required per series: •Minimum 124 sq. in. of free air space for Series 40-130 •Minimum 200 sq. in. of free air space for Series 150-200 This is the minimum required but can always be greater. The heat release can be added as a louver or as a reveal. If using a louver, please make sure that the free airspace allowed in the louvered area is equal or greater than the minimum square inches required per unit. Fireplace Legs All Ortal built-in fireplaces (Clear Front, LS, RS, TS, and Space Creator) come standard with legs that measure 8.3” from the bottom of the fireplace glass opening to the floor. This is the minimum height for the firebox to rest on the floor. The units do come with leg extensions which can raise the height to an approximate 15-16”. A platform may also be built if needed to elevate the firebox higher. The legs cannot be removed. Front Stand Alone models come with legs that are used for transportation purposes only. These are connected with a bolt that can be removed once unit is installed on site. Since these do not have legs, they can only be wall mounted. For multi-sided Stand Alone units, the legs are hidden by a metal skirt. These units can be installed to stay on the floor or wall mounted. Clearance Diagrams on following pages. 07/25/2018 12 07/25/2018 13 07/25/2018 14 07/25/2018 15 07/25/2018 16 07/25/2018 17 07/25/2018 18 07/25/2018 19 07/25/2018 20 07/25/2018 21 07/25/2018 22 07/25/2018 23 07/25/2018 24 07/25/2018 25 07/25/2018 26 07/25/2018 27 Manufacturer’s Recommendation for Wall Mounting Stand Alone Models 1.Concrete Wall a.Position the unit at the desired height and mark the wall. Unit should have a minimum 12” and maximum 30” distance from the bottom of the unit to the floor. b.Mount the Stand Alone hanging bracket using Hilti 3/8” x 3” Kwik bolt 3 expansion anchors with manufacturer’s requirement of 2-1/2” embedment and torque to 20ft-lbs. c. Attach the unit to the mounting bracket. d.See Sketch 1 for detail. 2. Wood Stud Wall a.Position the unit at the desired height and mark the wall. Unit should have a minimum 12” and maximum 30” distance from the bottom of the unit to the floor b.Create an opening in the wall big enough to position the 4x8 blocks between the wood studs at the desired height. c.Repair the opening with hardy backer board. d.Make sure that the bracket has a minimum 4” extra hardy backer board material around it. e.Mount bracket with a 3/8” x 4” lag bolts. Follow bracket manufacturer’s installation requirements and then mount the unit. f.See sketch 2 for detail. Note: All installations are to be completed per local building codes and safety requirements. The above recommendation does not take the place of reviewing and incorporating structural requirements set forth by the building engineer, local codes, etc. 07/25/2018 28 Concrete Wall Mounting Detail Sketch 1 07/25/2018 29 Wood Stud Mounting Detail Sketch 2 07/25/2018 30 Stand Alone – Front facing models 07/25/2018 31 Stand Alone – Three Sided models 07/25/2018 32 Stand Alone 75 07/25/2018 33 Stand Alone 75 bracket 07/25/2018 34 Stand Alone 110 07/25/2018 35 Stand Alone 110 bracket 07/25/2018 36 Stand Alone 150 07/25/2018 37 Stand Alone 150 bracket 07/25/2018