HomeMy WebLinkAboutFile Documents.535 E Hyman Ave.0024.2018 (6).ACBKCOMcheck Software Version 4.0.7.1 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Construction Site: 535 E Hyman Ave Unit 103 Aspen, CO 81611 Owner/Agent: Frank Finocchio Frame 3578 Hayden Ave Suite N1 Culver City, CA 90232 Designer/Contractor: Eric Rubottom BG Buildingworks, Inc. 251 Linden St Suite 200 Fort Collins, CO 80524 970.221.5691 elrubottom@bgbuildingworks.com Project Information Energy Code: Frame Enhanced Interior Lighting Controls Additional Efficiency Package Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Sales Floor (Retail:Sales Area)1230 1.59 1956 1.40 720 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL1 1230 (a) 1.40 0 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL2 0 (a) 1.40 0 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL3 0 (a) 2-Fitting Rooms (Retail:Dressing/Fitting Room)77 0.71 55 3-Office / Storage (Common Space Types:Office - Enclosed)224 1.11 249 4-Storage Closets (Common Space Types:Storage)49 0.63 31 3010Total Allowed Watts = (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b)Allowance is (B x C) or the actual wattage of the fixtures given in Section 2, whichever is less. Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Sales Floor (Retail:Sales Area) Track lighting 1: CL1: T1/T2/T3: Wattage based on current limiting device capacity 0 0 720 720 Track lighting 3: CL2: T4-T10: Wattage based on current limiting device capacity 0 0 1200 1200 Track lighting 2: CL3: T11/T12: Wattage based on current limiting device capacity 0 0 600 600 LED 3: D: Pendant: Other:1 1 150 150 2-Fitting Rooms (Retail:Dressing/Fitting Room) LED 1: A: Fitting Room: LED Other Fixture Unit 16W:1 8 16 128 LED 5: F: Mirror Lighting: Other:1 40 5 Exempt Exemption:Furniture-mounted Supplemental Task Lighting 3-Office / Storage (Common Space Types:Office - Enclosed) LED 2: C: BOH: LED Linear 33W:1 6 30 180 4-Storage Closets (Common Space Types:Storage) Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 61 ofPage E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LED 2 copy 1: C: BOH: LED Linear 33W:1 1 30 30 3008Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.7.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 0.1% better than code Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 62 ofPage Inspection Checklist Requirements: 62.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.7.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C406.4 [FI54]1 Enhanced digital lighting controls efficiency package: Interior lighting has following enhanced lighting controls in accordance with Section C405.2.2: Luminaires capable of continuous dimming and being addressed individually, <= 8 luminaires controlled in combination in a daylight zone, digital control system for fixtures, "Sequence of Operations" documentation, and functional testing per Section C408. Complies Does Not Not Observable Not Applicable C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 65 ofPage Project Title: Data filename: Frame \\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame Lighting.cck 04/06/18Report date: 66 ofPage