HomeMy WebLinkAboutFile Documents.535 E Hyman Ave.0024.2018 (6).ACBKCOMcheck Software Version 4.0.7.1
Interior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Construction Site:
535 E Hyman Ave
Unit 103
Aspen, CO 81611
Owner/Agent:
Frank Finocchio
Frame
3578 Hayden Ave
Suite N1
Culver City, CA 90232
Designer/Contractor:
Eric Rubottom
BG Buildingworks, Inc.
251 Linden St
Suite 200
Fort Collins, CO 80524
970.221.5691
elrubottom@bgbuildingworks.com
Project Information
Energy Code:
Frame
Enhanced Interior Lighting Controls
Additional Efficiency Package
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Sales Floor (Retail:Sales Area)1230 1.59 1956
1.40 720 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL1 1230 (a)
1.40 0 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL2 0 (a)
1.40 0 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: CL3 0 (a)
2-Fitting Rooms (Retail:Dressing/Fitting Room)77 0.71 55
3-Office / Storage (Common Space Types:Office - Enclosed)224 1.11 249
4-Storage Closets (Common Space Types:Storage)49 0.63 31
3010Total Allowed Watts =
(a)Area claimed must not exceed the illuminated area permitted for this allowance type.
(b)Allowance is (B x C) or the actual wattage of the fixtures given in Section 2, whichever is less.
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
1-Sales Floor (Retail:Sales Area)
Track lighting 1: CL1: T1/T2/T3: Wattage based on current limiting device capacity 0 0 720 720
Track lighting 3: CL2: T4-T10: Wattage based on current limiting device capacity 0 0 1200 1200
Track lighting 2: CL3: T11/T12: Wattage based on current limiting device capacity 0 0 600 600
LED 3: D: Pendant: Other:1 1 150 150
2-Fitting Rooms (Retail:Dressing/Fitting Room)
LED 1: A: Fitting Room: LED Other Fixture Unit 16W:1 8 16 128
LED 5: F: Mirror Lighting: Other:1 40 5 Exempt
Exemption:Furniture-mounted Supplemental Task Lighting
3-Office / Storage (Common Space Types:Office - Enclosed)
LED 2: C: BOH: LED Linear 33W:1 6 30 180
4-Storage Closets (Common Space Types:Storage)
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
61 ofPage
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
LED 2 copy 1: C: BOH: LED Linear 33W:1 1 30 30
3008Total Proposed Watts =
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.0.7.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES: Design 0.1% better than code
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
62 ofPage
Inspection Checklist
Requirements: 62.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.0.7.1
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
C406
[PR9]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
63 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.1
[EL15]1
Lighting controls installed to uniformly
reduce the lighting load by at least
50%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1
[EL18]1
Occupancy sensors installed in
required spaces.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1,
C405.2.2.
3
[EL23]2
Independent lighting controls installed
per approved lighting plans and all
manual controls readily accessible and
visible to occupants.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.2.
1
[EL22]2
Automatic controls to shut off all
building lighting installed in all
buildings.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.3
[EL16]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
[EL20]1
Primary sidelighted areas are
equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.3,
C405.2.3.
1,
C405.2.3.
3
[EL21]1
Enclosed spaces with daylight area
under skylights and rooftop monitors
are equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.4
[EL4]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.4
[EL8]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.3
[EL6]1
Exit signs do not exceed 5 watts per
face.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
64 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
C405.4.1
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
C406.4
[FI54]1
Enhanced digital lighting controls
efficiency package: Interior lighting
has following enhanced lighting
controls in accordance with Section
C405.2.2: Luminaires capable of
continuous dimming and being
addressed individually, <= 8
luminaires controlled in combination
in a daylight zone, digital control
system for fixtures, "Sequence of
Operations" documentation, and
functional testing per Section C408.
Complies
Does Not
Not Observable
Not Applicable
C408.2.5.
1
[FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
C408.3
[FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
65 ofPage
Project Title:
Data filename:
Frame
\\bgce-rsnas\Data\BGProjects\9203.06 Aspen Core TI Frame- (Landlord Scope)\Engineering\Frame
Lighting.cck
04/06/18Report date:
66 ofPage