HomeMy WebLinkAboutFile Documents.611 S West End St.0055-2020-BCHO (4)
11 Duroux Lane Basalt, CO 81621 p. (970) 927-3600
www.helpers.solutions
Conducted at:
611 South West End Unit 3
Aspen, CO 81611
Conducted for:
Steve Smith
steve@renovateaspen.com
970.319.0121
Prepared by:
Anthony Pistono
Building Inspector
( CERT# AE-19-036-BI-R-01 ) – Expires 8.7.20
( CDPHE #20929 ) Expires 8.12.20
Helpers Disaster Restoration LLC
11 Duroux Lane Basalt, CO 81621
( CDPHE ACF-21564 ) – Expires 10.16.2019
Background:
Helpers Disaster Restoration LLC has performed limited bulk sampling for asbestos on
suspect materials in the areas to disturbed during renovations. Materials were sampled to
confirm or deny asbestos content. Materials are sampled using methods described in Section
IV.C. of the CDPHE Regulation 8.
Date of Inspection: 9.26.19
Date of Report: 9.30.19
Field Procedures and Analysis Methods:
Guidelines used for the inspection were established by the Environmental Protection
Agency (EPA) in the Guidance for Controlling Asbestos Containing Materials in Buildings,
Office of Pesticides and Toxic Substances, DOC #560/5-85-024 and 40 CFR Part 763,
Asbestos Hazard Emergency Response Act (AHERA). Field information was organized as per
the AHERA concept of Homogeneous Area. A Homogeneous Area is defined as a suspect
material of similar age, appearance, function and texture. Each material was grouped together
11/07/2019
11 Duroux Lane Basalt, CO 81621 p. (970) 927-3600
www.helpers.solutions
as a specific Homogeneous Area, sampled and then assessed for condition. Bulk samples
were collected in a statistically random manner, described in the EPA “Pink Book” (560-5-85-
30A). Bulk samples of suspect ACM were analyzed by Polarized Light Microscopy (PLM).
Scope of work:
Suspect materials in the kitchen, hallway, and hallway closets were bulk sampled to confirm or
deny asbestos content. Materials were sampled and inventoried for quantity, condition, and
friability.
Homogeneous Area Types and Sampling Requirements:
Surfacing Material
< 1,000 square feet – minimum 3 samples to be collected
1,000 – 5,000 square feet – minimum of 5 samples to be collected
> 5,000 square feet – minimum of 7 samples
Miscellaneous Material
minimum of 2 samples to be collected
Thermal System Insulation (TSI)
minimum of 3 samples to be collected
Assessment Categories:
1. Damaged or significantly damaged Thermal Systems Insulation (TSI) ACM
2. Damaged friable surfacing ACM
3. Significantly damaged friable Surfacing ACM
4. Damaged or significantly damaged friable Miscellaneous ACM
5. ACM with potential for damage
6. ACM with potential for significant damage
7. Friable ACM with low potential for damage
Other- ACM not classified in the above Assessment Categories
Homogeneous Areas:
WS1 – 3 // wall texture
( surfacing material // work area less than 1000 square feet - minimum of 3 samples )
WE1 – 3 // wall texture
( surfacing material // work area less than 1000 square feet - minimum of 3 samples )
W1 – 2 // drywall with mudded tape seams
( miscellaneous material // minimum 2 samples )
11/07/2019
11 Duroux Lane Basalt, CO 81621 p. (970) 927-3600
www.helpers.solutions
Sample Locations:
WS1 // main hallway behind painting
WS2 // hall to kitchen behind outlet cover
WS3 // hallway behind thermostat
WE1 // pantry vacuum closet at hole – left side of closet
WE2 // pantry vacuum closet at hole – right side of closet
WE3 // hallway ironing board closet – back wall at nail
W1 // ironing board closet at corner of back and left walls
W2 // mechanical closet at left side of door jamb
Conclusions:
Laboratory analysis confirms that sample set WS1 – 3 contains up to 3% Chrysotile asbestos.
This surfacing material at the time of inspection was in good condition and friable. There is
approximately 180 square feet of this material to be removed for renovations. In current
condition this material has a high potential for disturbance.
Laboratory analysis confirms that sample set WE1 – 3 contains up to 4% Chrysotile asbestos.
This surfacing material at the time of inspection was in good condition and friable. There is
approximately 180 square feet of this material to be removed for renovations. In current
condition this material has a high potential for disturbance.
Laboratory analysis confirms sample set LT1 – 2 to contain up to 3% Chrysotile asbestos in
the joint compound. There is approximately 360 square feet of this material present in the
hallway. This material at the time of inspection was in good condition and friable. This
material in its current condition has a high potential for disturbance.
Materials confirmed ACM will need to be removed by a general abatement contractor in
accordance with CDPHE Regulation 8, and OSHA Regulations. All materials sampled as part
of a functional wall system will need to be abated per the regulations.
Materials confirmed to be non-asbestos containing can be removed following general
demolition procedures following OSHA standards and safe work practices.
Materials sampled were collected based upon the scope of renovating these materials only.
This is by no means a comprehensive building inspection. If more materials are to be affected
and removed that are suspect ACM or ACBM which were not sampled - work must cease, and
further sampling must occur.
Please let us know if you have any questions or concerns.
11/07/2019
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective April 2, 2018
Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Subcontract Number:NA
Laboratory Report:RES 445842-1
Project # / P.O. # None Given
Project Description:611 South West End Street #3
RES 445842-1
Sincerely,
is the job number assigned to this study. This report is considered highly confidential
and the sole property of the customer.Reservoirs Environmental,Inc.will not discuss any part of this study with
personnel other than those of the client.The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the
U.S.Government.This report shall not be reproduced except in full,without written approval from Reservoirs
Environmental,Inc.Samples will be disposed of after sixty days unless longer storage is requested.If you have any
questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
September 27, 2019
Dear Customer,
Reservoirs Environmental,Inc.is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP),Lab Code 101896-0
for Transmission Electron Microscopy (TEM)and Polarized Light Microscopy (PLM)analysis and the American
Industrial Hygiene Association (AIHA),Lab ID 101533 -Accreditation Certificate #480 for Phase Contrast
Microscopy (PCM)analysis.This laboratory is currently proficient in both Proficiency Testing and PAT programs
respectively.
Reservoirs Environmental,Inc.has analyzed the following samples for asbestos content as per your request.The
analysis has been completed in general accordance with the appropriate methodology as stated in the attached
analysis table. The results have been submitted to your office.
Helpers Disaster Restoration, LLC
11 Duroux Lane
Basalt CO 81621
Anthony Pistono
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 1
1-866-RESI-ENV
www.reilab.com
11/07/2019
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 445842-1
Helpers Disaster Restoration, LLC
None Given
611 South West End Street #3
September 26, 2019
Priority
September 26, 2019
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective April 2, 2018
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
L
A
YE
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
970WS1Off white compoundA 5 3 Chrysotile
1000White/multi-colored paintB 5 ND
1000White compound w/ white/beige paintC 10 ND
8218Gray/tan drywallD 80 ND
970WS2Off white compoundA 5 3 Chrysotile
1000White/multi-colored paintB 5 ND
1000White texture w/ beige paintC 10 ND
8218Gray/tan drywallD 80 ND
970WS3Off white compoundA 2 3 Chrysotile
1000White/multi-colored paintB 8 ND
1000White texture w/ beige paintC 10 ND
8317Off white/tan drywallD 80 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 1 of 3
11/07/2019
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 445842-1
Helpers Disaster Restoration, LLC
None Given
611 South West End Street #3
September 26, 2019
Priority
September 26, 2019
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective April 2, 2018
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
L
A
YE
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000W1White paintA 2 ND
1090Off white tapeB 5 ND
970Off white textureC 8 3 Chrysotile
970Off white joint compoundD 10 3 Chrysotile
8020Off white/tan drywallE 75 ND
970W2Off white joint compoundA 20 3 Chrysotile
2080Off white/tan drywallB 40 ND
1585Off white tape w/ white paintC 40 ND
1000WE1White/off white paintA 5 ND
960Off white textureB 10 4 Chrysotile
8218Off white/tan drywallC 85 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 2 of 3
11/07/2019
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 445842-1
Helpers Disaster Restoration, LLC
None Given
611 South West End Street #3
September 26, 2019
Priority
September 26, 2019
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective April 2, 2018
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
L
A
YE
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000WE2White/off white paintA 5 ND
960Off white textureB 10 4 Chrysotile
8218Off white/tan drywallC 85 ND
960WE3Off white textureA 5 4 Chrysotile
1000White/off white paintB 5 ND
8317Off white/tan drywallC 90 ND
Analyst / Data QAAnalystAnalystAnalystAnalyst
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 3 of 3
11/07/2019
11/07/2019
11/07/2019