Loading...
HomeMy WebLinkAboutagenda.boa.202112021 AGENDA ASPEN BOARD OF ADJUSTMENT December 2, 2021 4:30 PM, Sister Cities Meeting Room 130 S Galena Street, Aspen WEBEX MEETING INFORMATION WEBEX MEETING INSTRUCTIONS TO JOIN ONLINE: Go to www.webex.com and click on "Join a Meeting" Enter Meeting Number: 2559 942 4222 Enter Password: 81611 Click "Join Meeting" -- OR -- JOIN BY PHONE Call: 1-408-418-9388 Enter Meeting Number: 2559 942 4222 Enter Password: 81611 I.SITE VISIT II.ROLL CALL III.COMMENTS IV.MINUTES V.DECLARATION OF CONFLICT OF INTEREST VI.PUBLIC HEARINGS VI.A.325 Park Ave - Dimensional Variance and Associated Reviews Memo.325 Park Ave.20211029.docx Exhibit A - Dimensional Variance Review Criteria.20211129.docx Exhibit B - Stream Margin Review Criteria.20211129.docx Exhibit C - RDS Approval.325 Park.20211129.pdf Exhibit D - Original Application.325 Park.20210616.pdf Exhibit E - Supplemental Application.pdf Exhibit F - Public Notice Affidavit.pdf Resolution No. 02 Series of 2021.325 Park Ave.20211129.docx VII.OTHER BUSINESS 1 2 VIII.BOARD REPORTS IX.ADJOURN Typical Proceeding Format for All Public Hearings 1)Conflicts of Interest (handled at beginning of agenda) 2) Provide proof of legal notice (affidavit of notice for PH) 3) Staff presentation 4) Board questions and clarifications of staff 5) Applicant presentation 6) Board questions and clarifications of applicant 7) Public comments 8)Board questions and clarifications relating to public comments 9) Close public comment portion of bearing 10) Staff rebuttal/clarification of evidence presented by applicant and public comment 11) Applicant rebuttal/clarification End of fact finding. Deliberation by the commission commences. No further interaction between commission and staff, applicant or public 12) Chairperson identified the issues to be discussed among commissioners. 13) Discussion between commissioners* 14) Motion* *Make sure the discussion and motion includes what criteria are met or not met. Revised January 8, 2021 2 Page 1 of 5 MEMORANDUM TO:City of Aspen Board of Adjustment FROM:Garrett Larimer, Senior Planner THRU:Bob Narracci, Zoning Administrator RE:325 Park Ave., Dimensional Variance and Associated Administrative Reviews Resolution No. 02, Series of 2021 MEETING DATE:November 11th, 2021 APPLICANT: Wiezbowski Sharon A & Stephen L Rev. Trust 151 Alice B Toklas Pl. #109 San Francisco, CA 94109 REPRESENTATIVE: Flynn Stewart-Severy F&M Architects, LLC PO Box 6762, Snowmass Village, CO 81615 LOCATION: 325 Park Avenue PID#2737-181-00-211 CURRENT ZONING AND USE: Medium Density Residential (R6), Existing 2-story single family residence Lot Size: 2,692 Square Feet SUMMARY OF REQUEST: The Applicant proposes an addition and remodel of the residence including, a carport, enclosed front entry, and a patio to the south of the existing structure. The application requests a setback variance, Stream Margin, and Residential Design Standard Reviews. STAFF RECOMMENDATION: Staff recommends the BOA approve the requested Setback Variance, Stream Margin, and Residential Design Standard reviews, with conditions. FIGURE 1:PROPERTY LOCATION 3 Page 2 of 5 REQUEST OF THE BOARD OF ADJUSTMENT:The Applicant is requesting the following approval from the Board of Adjustment (BOA): Variance (Chapter 26.314) to grant a Dimensional Variance to the setbacks (The Board of Adjustment is the final review authority). Stream Margin Review (Section 26.435.040.C)to approve landscaping improvements and site work within the Stream Margin Review Area. (The application qualifies for administrative approval,but the request is being consolidated for efficiency). Residential Design Standards (Section 26.410.030) for the proposed addition and remodel to the existing structure. (The Application qualifies for administrative approval,but the request is being consolidated for efficiency and clarity). BACKGROUND AND EXISTING CONDITIONS: The subject site contains an existing single-family residence developed sometime in the 1980s and is often referred to as the Triangle House. The property is 2,692 square feet and is zoned Medium Density Residential (R6). Figure 2: Existing Conditions REQUEST: The Applicant requests approval for a Dimensional Variance to the setbacks and Residential Design Standard Review for a remodel and addition to the site. A small portion of the western part of the lot falls within the Stream Margin Review Area (SMRA). The work within the SMRA is subject to Stream margin Review, all work outside the SRMA is not subject to Stream Margin Review. The application qualifies for administrative approval of the Stream Margin and Residential Design Standard Reviews, but the Variance requires review by the Board of Adjustment. All reviews are combined to be approved simultaneously by the BOA for efficiency. 4 Page 3 of 5 A one-story addition, covered patio, and carport is proposed on the south east corner of the existing house. The proposed addition encroaches into the front yard setback. The front yard setback in the R-6 Zone District is a minimum 10’. The carport roof encroaches into the setback 5’, the structure supporting the carport encroaches 3’6”, and the one-story addition encroaches 3’. Figure 3: Proposed Rendering The following minimum front yard setbacks are requested for the design: -Roof Overhang: 5’ -Structural Column (to support carport roof): 7’ -Front Entry: ~7’-7’5” Figure 4: Proposed Rendering 5 Page 4 of 5 REVIEWS DIMENSIONAL VARIANCE: In order to meet the Review Criteria and qualify for a Dimensional Variance, 3 criteria must be met: 1. The variance is generally consistent with the intent and objectives of the Code. 2. It’s the minimum variance to allow reasonable use of the property. 3. Enforcement of the dimensional requirements in the code would cause the property owner “unnecessary hardship, as distinguished from mere inconvenience…” The BOA must consider if there are special circumstances or site constraints that are unique to this property, or whether granting of a variance provides special privilege not enjoyed by other property owners. STREAM MARGIN: In order to meet the Review Criteria and qualify for a Permitted Use Variance, 11 criteria must be met. Detailed responses to those review criteria can be found in Exhibit B. The Application complies with all applicable review criteria. Given the limited area within the SRMA, the majority of the scope is not subject to Stream Margin Review. RESIDENTIAL DESIGN STANDARDS: The application must comply with all Residential Design Standards that are relevant to the proposed remodel and addition. Since it’s an existing structure and a remodel is proposed, not all standards are applicable, and flexibility is provided in the code when compliance would be unreasonable given the existing condition. The approved RDS Staff checklist, outlining of how the project complies with the Residential Design Standards, can be found in Exhibit C. STAFF COMMENTS The subject site is 2,692 square feet. The minimum lot size for non-historic properties in the R-6 zone district is 6,000 sq. ft., so the lot is significantly undersized. The lot is triangular and irregularly shaped. The setbacks in the R-6 zone district are not intended for a lot of this size and restrict development to a small area. The ratio of developable area, to areas restricted by setbacks, is less than many lots in the R- 6 zone district or surrounding area. The shape of the lot further restricts options for an addition or remodel. Staff agrees there are unique site-specific constraints of this parcel. Staff has also found that the requested setback variance allow reasonable use of the property, while maintaining an appropriate setback from the front property line. There are zone districts in the immediate vicinity that allow 5’ setbacks by right for some types of development, so the requested setback variance is not out of character for the area. The pavement of Park Ave is very close to the edge of the property line, so the applicant has worked closely with Engineering to ensure the requested setback variance minimizes negative outcomes, or potential hazards with the ROW, to the extent practical. Engineering has reviewed the proposed design and requested variance, and is supportive of the setback variance. Staff feels the request meets the review criteria, is reasonable given the site context, is consistent with the objective of the code to maintain reasonable buffer between development and the property line, and would not be out of character for the surrounding area. REFERRAL AGENCIES Staff consulted with the City Parks and Engineering Departments and each agree with Staff’s position - supporting a recommendation of approval with conditions. Conditions of approval included in the draft resolution that address their comments. RECOMMENDATION: Staff has found the application to meet all review criteria and recommends approval with conditions. ALTERNATIVE: 6 Page 5 of 5 If the BOA disagrees with any proposed conditions of approval in the resolution and wishes to amend the proposed Resolution by removing conditions of approval, staff requests the BOA continue the hearing to ensure the Parks and Engineering Department have an opportunity to weigh in on and respond to the proposed changes. PROPOSED MOTION (All motions are proposed in the affirmative): “I move to approve Resolution No. 02, Series 2021, with conditions, approving a Dimensional variance are described in illustrated in the Resolution, to allow for an addition and remodel of the site” ATTACHMENTS: Exhibit A –Variance Review Criteria Exhibit B – Stream Margin Review Criteria Exhibit C – Residential Design Standard Approval Exhibit D –Original Application Exhibit E – Supplemental Application Exhibit F –Public Notice Affidavit 7 Exhibit A Permitted Use Variance – Review Criteria 26.314.40 – Variances B. In order to authorize a variance from the dimensional requirements of Title 26, the appropriate decision-making body shall make a finding that the following three (3) circumstances exist: 1. The grant of variance will be generally consistent with the purposes, goals, objectives and policies of this Title and the Municipal Code; and Staff Response: Dimensional limitations help establish height, mass, and scale of a development that’s appropriate for the neighborhood. For this zone district, a minimum lot size is established, and dimensional limitations are assumed to apply to lots of that size, or greater. This is an undersized lot, and the same setbacks are required as if it was a standard lot. The requested setback still provides a buffer between developable area and the property line but are more appropriate for the lot size. The requested variance is also consistent with similar setbacks for zone districts in the immediate area. For example, in the Residential Multi-Family (RMF) zone district, the multi-family residential setback is 5’. The RMF zone district is located directly across the street from this lot. So, the relief from setback requirements is reasonable, consistent with the goals and objectives of the code, and appropriate given the neighborhood context, therefore, staff has found this criterion to be met. 2. The grant of variance is the minimum variance that will make possible the reasonable use of the parcel, building or structure; and Staff Response: Staff has found the requested variance to be appropriate given the unusual lot shape and undersized lot area for this zone district. A reasonable setback is still maintained to provide a buffer between the development and property line. Given the lot shape, size and existing development, staff feels the variance makes possible reasonable use of the property given the site constraints. Staff finds this criterion to be met. 3. Literal interpretation and enforcement of the terms and provisions of this Title would deprive the applicant of rights commonly enjoyed by other parcels in the same zone district and would cause the applicant unnecessary hardship, as distinguished from mere inconvenience. In determining whether an applicant's rights would be deprived, the Board shall consider whether either of the following conditions apply: a. There are special conditions and circumstances which are unique to the parcel, building or structure, which are not applicable to other parcels, structures or buildings in the same zone district, and which do not result from the actions of the applicant; or b. Granting the variance will not confer upon the applicant any special privilege denied by the terms of this Title and the Municipal Code to other parcels, buildings or structures, in the same zone district. Staff Response: The lot is irregularly shaped and undersized which makes it unique when compared to many lots in the same zone district. The ratio of developable area is reduced when setbacks are consistent with the zone district, but the overall size of the lot is substandard. The variance requested provide reasonable relief from the special circumstances that exist for this lot. A reasonable setback, consistent with required 8 Exhibit A Permitted Use Variance – Review Criteria setbacks for other residential properties in the same area and zone district are requested. Staff has determined this criterion has been met. 9 Exhibit B Stream Margin Review Criteria 1 | P a g e Section 26.435.040 C. Stream margin review standards. No development shall be permitted within the stream margin of the Roaring Fork River unless the Community Development Director makes a determination that the proposed development complies with all requirements set forth below: 1. It can be demonstrated that any proposed development which is in the Special Flood Hazard Area will not increase the base flood elevation on the parcel proposed for development. This shall be demonstrated by an engineering study prepared by a professional engineer registered to practice in the State which shows that the base flood elevation will not be raised, including, but not limited to, proposing mitigation techniques on or off-site which compensate for any base flood elevation increase caused by the development; and Staff Response: The application includes a map confirming the property is not within a Special Flood Hazard Area. Staff finds this criterion to be not applicable. 2. The recommendations of the Aspen Area Community Plan: Parks/Recreation/Open Space/Trails Plan and the Roaring Fork River Greenway Plan are implemented in the proposed plan for development, to the greatest extent practicable. Areas of historic public use or access shall be dedicated via a recorded easement for public use. A fisherman's easement granting public fishing access within the high-water boundaries of the river course shall be granted via a recorded "Fisherman's Easement;" and Staff Response: No public use, access, or easements exist on the property. Staff finds this criterion not applicable. 3. There is no vegetation removed or damaged or slope grade changes (cut or fill) made outside of a specifically defined building envelope. A building envelope shall be designated by this review and said envelope shall be designated by this review and said envelope shall be recorded on a plat pursuant to Subsection 26.435.040.F.1; and Staff Response: The existing condition of the area within the Stream Margin Review area is gravel. Although a building envelope is not established on the lot, no development occurs outside the setback in the Stream Margin Review area. Staff finds this criterion to be met. 4. The proposed development does not pollute or interfere with the natural changes of the river, stream or other tributary, including erosion and/or sedimentation during construction. Increased on-site drainage shall be accommodated within the parcel to prevent entry into the river or onto its banks. Pools or hot tubs cannot be drained outside of the designated building envelope; and Staff Response: None of the changes affect the waterways, all improvements will be required to comply with Engineering’s URMP and the development is not expected to result in increased erosion or runoff. Staff finds this criterion to be met. 10 Exhibit B Stream Margin Review Criteria 2 | P a g e 5. Written notice is given to the Colorado Water Conservation Board prior to any alteration or relocation of a water course and a copy of said notice is submitted to the Federal Emergency Management Agency; and Staff Response: No new alteration of the watercourse is proposed. Written notice to the Colorado Water Conservation Board and the Federal Emergency Management Agency is not required. Staff finds this criterion not applicable. 5. A guarantee is provided in the event a water course is altered or relocated, that applies to the developer and his heirs, successors and assigns that ensures that the flood carrying capacity on the parcel is not diminished; and Staff Response: The proposed development will not alter or relocate the existing water course from the current condition. Staff finds this criterion to be not applicable. 7. Copies are provided of all necessary federal and state permits relating to work within the 100-year flood plain; and Staff Response: The subject site is not within the 100-year flood plain. Staff finds this criterion to be not applicable. 8. There is no development other than approved native vegetation planting taking place below the top of slope or within fifteen (15) feet of the top of slope or the high waterline, whichever is most restrictive. This is an effort to protect the existing riparian vegetation and bank stability. New plantings (including trees, shrubs, flowers and grasses) outside of the designated building envelope on the river side shall be native riparian vegetation as approved by the City. A landscape plan will be submitted with all development applications. The top of slope and 100-year flood plain elevationof the Roaring Fork River shall be determined by the Stream Margin Map located in the Community Development Department and filed at the City Engineering Department; and Staff Response: The Top of Slope and corresponding setback do not fall within this property. Staff finds this criterion to be met. 9. All development outside the fifteen (15) foot setback from the top of slope does not exceed a height delineated by a line drawn at a forty-five (45) degree angle from ground level at the top of slope. Height shall be measured and determined by the Community Development Director using the definition for height set forth at Section 26.04.100 and method of calculating height set forth at Section 26.575.020 as shown in Figure "A"; and 11 Exhibit B Stream Margin Review Criteria 3 | P a g e Staff Response: The Top of Slope and corresponding setback do not fall within or near this property. Staff finds this criterion to be met. 10. All exterior lighting is low and downcast with no light(s) directed toward the river or located down the slope and shall be in compliance with Section 26.575.150. A lighting plan will be submitted with all development applications; and Staff Response: All proposed lighting will be required to comply with the City’s Lighting regulations prior to building permit issuance. Staff finds this criterion to be met. 11. There has been accurate identification of wetlands and riparian zones. Staff Response: The property does not exist within a wetland or riparian zone. Staff finds this criterion to be met. 12 Residential Design Standards Administrative Compliance Review Staff Checklist - Single Family and Duplex Standard Complies Alternative Compliance Does Not Comply N/A Sheet #(s)/Notes B.1.Articulation of Building Mass (Non-flexible) B.2.Building Orientation (Flexible) B.3.Build-to Requirement (Flexible) B.4.One Story Element (Flexible) C.1.Garage Access (Non-flexible) C.2.Garage Placement (Non-flexible) C.3.Garage Dimensions (Flexible) Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 2 Approved: (Approved plans/elevations attached) 13 Standard Complies Alternative Compliance Doesn’t Comply N/A Sheet #(s)/Notes C.4.Garage Door Design (Flexible) D.1.Entry Connection (Non-flexible) D.2.Door Height (Flexible) D.3.Entry Porch (Flexible) E.1.Principle Window (Flexible) E.2.Window Placement (Flexible) E.3.Nonorthogonal Window Limit (Flexible) E.4.Lightwell/Stairwell Location (Flexible) E.5.Materials (Flexible) Residential Design Standards Administrative Compliance Review Staff Checklist Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Page 2 of 2 Approved: 14 PRE-APPLICATION CONFERENCE SUMMARY (PRE-21-072) PLANNER: Garrett Larimer, garrett.larimer@cityofaspen.com DATE: June 2nd, 2021 PROJECT LOCATION: 325 Park Avenue REPRESENTATIVE: Flynn Stewart-Severy, F&M Architects – flynn@fandmarchitects.com REQUEST: Stream Margin Review DESCRIPTION: The south west corner of the subject property is within the Stream Margin Review Area adjacent to the Roaring Fork River. The applicant proposes site work, a remodel and an addition to the structure. Only the work within the Stream Margin review area is subject to Stream Margin Review. The applicant can apply for and received Residential Design Standard approval separately or as part of this application. RDS Approval will be required prior to permit submission. The proposed scope of work is subject to Stream Margin review pursuant to Section 26.435.040.C. The application does not qualify for a Stream Margin Exemption since the proposed site work on the south gets closer to the Roaring Fork River than the existing structure. The application will need to include written responses showing compliance with the review criteria contained in Section 26.435.040.C. The City of Aspen Parks and Engineering Departments will be referral agencies reviewing the application and will provide comments on the application if necessary. RELEVANT LAND USE CODE SECTIONS: Section Number Section Title 26.304 Common Development Review Procedures 26.435.040.C Stream Margin Review For your convenience – links to the Land Use Application and Land Use Code are below: Land Use Application Land Use Code REVIEW BY: Staff for complete application and administrative review PUBLIC HEARING: No PLANNING FEES: $1,300 for 4 hours of staff time REFERRAL FEES: Engineering Department: $325/hour Parks Department: $650 flat fee TOTAL DEPOSIT: $2,275 (Additional/fewer hours billed/refunded at $325 per hour) APPLICATION CHECKLIST: (Please submit a digital copy of the application to the planner listed on the preapplication.)  Completed Land Use Application and signed Fee Agreement.  Pre-application Conference Summary (this document). 15  Street address and legal description of the parcel on which development is proposed to occur, consisting of a current (no older than 6 months) certificate from a title insurance company, an ownership and encumbrance report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for the Development Application. The purpose of this requirement is to show that the Applicant has the authority to apply for a Land Use Case.  Applicant’s name, address and telephone number in a letter signed by the applicant that states the name, address and telephone number of the representative authorized to act on behalf of the applicant.  A site improvement survey (no older than a year from submittal) including topography, existing structures, and vegetation showing the current status of the parcel certified by a registered land surveyor by licensed in the State of Colorado. This survey also is required to depict the 100-year flood plain, the high-water mark of the roaring fork river, top of slope, building envelopes, and any ditch easement that cross the property.  A written and visual description of the proposal and response to how the proposed development complies with the review standards relevant to the development application Section 26.435.040.C Stream Margin Review  Site plan and site section depicting the proposed scope of work.  HOA Compliance form (Attached to Application) Once the copy is deemed complete by staff, the following items will then need to be submitted:  Total deposit for review of the application. Disclaimer: The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. The summary does not create a legal or vested right. 16 Project No. 20064 PO Box 6762 15 Kearns Road, Suite D Snowmass Village CO 81615 970.987.2707 DATE: June 8, 2021 TO: City of Aspen Parks and Engineering -130 South Galena St, Aspen, CO 81611 RE: 325 Park Ave, Stream Margin Review Dear COA, DESCRIPTION: The southwest corner of the subject property is within the Stream Margin Review Area adjacent to the Roaring Fork River. We are proposing site work, a remodel, and an addition to the structure. Only the work within the Stream Margin review area is subject to Stream Margin Review. That work will consist of 49.6 SQ FT of existing building floor area already withing the stream margin boundary flood plain line. The addition will add about 1.7 SQ FT of floor area within the stream margin boundary. Additionally, 36 SQ FT of at or below existing grade is proposed to lie within the stream margin boundary. No further landscaping or changes to existing grade will take place within the stream margin boundary. The proposed scope of work is subject to Stream Margin review pursuant to Section 26.435.040.C. RESPONSES: 1. Proposed development does not lie within a Special Flood Hazard Area. See attached FIRMETTE map showing property in Zone X. 2. The proposed development has no river frontage, easements, or public access. See provided Improvement Survey Plat. 3. There is no vegetation removed or damaged or slope grade changes (cut or fill) made outside defined building envelope. Proposed Concrete patio will be maximum 18” below grade which is within the 30” allowed by Sec 26.575.020(e)(5)m. 4. The proposed development will not pollute or interfere with the natural changes of the river, stream, or other tributary, including erosion and/or sedimentation during construction. Site drainage will not change, and appropriate erosion control and construction fencing will be used. See construction management site plan Sheet CMP. 5. No alteration or relocation of water course. 6. No alteration or relocation of water course. 7. No federal or state permits required in Zone X. 17 Project No. 20064 PO Box 6762 15 Kearns Road, Suite D Snowmass Village CO 81615 970.987.2707 8. Existing height and upper level of existing building is not changing. Addition is to main level (ground level) only. Top of slope is further than 15’ away and does not lie within property boundaries. See sheet A1.2 for TOS diagram. 9. All proposed development is outside the fifteen (15) foot setback from the top of slope. See site plan sheet A1.2. 10. All exterior lighting is low and downcast with no light(s) directed toward the river or located down the slope and shall be in compliance with Section 26.575.150. See exterior lighting on site plan A1.1 and attached fixture cut sheet. 11. Proposed development does not lie within wetlands or riparian zones. Best Regards, Flynn Stewart-Severy AIA F&M Architects LLC Principal Architect (c) 970.319.4407 flynn@fandmarchitects.com 18 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex Standard Complies Alternative Compliance N/A Sheet #(s)/Notes B.1.Articulation of Building Mass (Non-flexible) B.2.Building Orientation (Flexible) B.3.Build-to Requirement (Flexible) B.4.One Story Element (Flexible) C.1.Garage Access (Non-flexible) C.2.Garage Placement (Non-flexible) C.3.Garage Dimensions (Flexible) Instructions: Please fill out the checklist below, marking whether the proposed design complies with the applicable standard as written or is requesting Alternative Compliance (only permitted for Flexible standards). Also include the sheet #(s) demonstrating the applicable standard. If a standard does not apply, please mark N/A and include in the Notes section why it does not apply. If Alternative Compliance is requested for a Flexible standard, include in the Notes section how the proposed design meets the intent of the standard(s). Additional sheets/graphics may be attached. Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 2 19 Standard Complies Alternative Compliance N/A Sheet #(s)/Notes C.4.Garage Door Design (Flexible) D.1.Entry Connection (Non-flexible) D.2.Door Height (Flexible) D.3.Entry Porch (Flexible) E.1.Principle Window (Flexible) E.2.Window Placement (Flexible) E.3.Nonorthogonal Window Limit (Flexible) E.4.Lightwell/Stairwell Location (Flexible) E.5.Materials (Flexible) Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Page 2 of 2 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex 20 TRIANGLE HOUSE 325 PARK AVE ASPEN, CO 81611 REMODEL/ADDITION PROJECT #20064 STREAM MARGIN REVIEW & RDS APPLICATION GENERAL CONTRACTOR STEEPLECHASE CONSTRUCTION, INC0124 TOTTERDOWN ROADASPEN, CO 81611 CONTACT: STEVE WALDECK -(C) 970.379.6268 STRUCTURAL ENGINEER ASCENT GROUP6707 WINCHESTER CIRCLE, SUITE 100BOULDER, CO 80301 CONTACT: CHRIS KRAUSS -(O) 303.865.4946 ARCHITECT F&M ARCHITECTS LLCMAIL: PO BOX 6762PHYSICAL: 15 KEARNS ROAD, SUITE. D SNOWMASS VILLAGE, CO 81615http://fandmarchitects.com CONTACT: FLYNN STEWART-SEVERY -(O) 970.987.2707 (C) 970.319.4407PATRICK WESTFELDT -(O) 970.309.5779 June 16, 2021ISSUE DATE 21 G1.1G1.2 COVER SHEET WITH DIRECTORYINFORMATION INDEX OF DRAWINGSGENERAL NOTES: 1. THESE DOCUMENTS, INCLUDING ALL INFORMATION, DESIGNS, DETAILS, SPECIFICATIONS, CONFIGURATIONS AND EVERY OTHER PORTION THEREOF, AND FURTHER PERTAINING TO ALL ORIGINALS AND COPIES GENERATED, TRANSMITTED OR CIRCULATED FOR THE PURPOSE OF BIDDING, PURCHASING, SCHEDULING, CONSTRUCTION OR FOR SUCH OTHER REASON AS MAY BE REQUIRED FOR THE PROJECT DESCRIBED HEREIN, ARE AND SHALL REMAIN THE EXCLUSIVE PROPERTY OF F&M ARCHITECTS LLC. THESE DOCUMENTS MAY NOT BE COPIED, DISTRIBUTED OR OTHERWISE PLACED INTO USE OR SERVICE OF ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF F&M ARCHITECTS LLC OR DULY AUTHORIZED AGENT. ALL DOCUMENTS DISTRIBUTED DURING THE COURSE OF THE PROJECT SHALL BE SURRENDERED TO F&M ARCHITECTS LLC IMMEDIATELY UPON REQUEST. 2. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE DESIGNER RESERVES THE RIGHT TO TAKE EXCEPTIONS TO APPROVED METHODS AND MATERIALS NOT REFLECTED HEREIN. 3. WORK SHALL BE PERFORMED IN A WORKMANLIKE OR CRAFTMANLIKE MANNER TO THE SATISFACTION OF THE OWNER. 4. THE DRAWINGS SHALL NOT BE SCALED TO DETERMINE CONSTRUCTION DIMENSIONS. THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO THE EXECUTION OF THE WORK, AND SHALL BE RESPONSIBLE FOR THE CORRECT AND ACCURATE LAYOUT AND CONSTRUCTION OF THE PROJECT. 5. DIMENSIONS ARE TO FACE OF STUD OR CONCRETE UNLESS OTHERWISE NOTED. 6. REFER TO PROJECT OUTLINE SPECIFICATIONS FOR ROOM FINISHES. 7. COORDINATE ELECTRICAL, PLUMBING, AND MECHANICAL WITH STRUCTURAL FRAMING. 8. FOR DATUM INFORMATION, REFER TO SHEET A0.1. 9. IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES. FLOOR PLANS TAKE PRECEDENCE. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS INCLUDING BUT NOT LIMITED TO: EXAMINATION OF SITE AND DOCUMENTS, ADDENDA, MEANS AND METHODS, CONSTRUCTION SYSTEMS, INSTALLATIONS, BIDDING AND SUBCONTRACTORS. LOCAL JURISDICTIONS OF AUTHORITY, COMPLIANCE WITH THE INTERNATIONAL RESIDENTIAL CODE, AND THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION. CONTRACTOR SHALL ALSO RETAIN ALL TRADITIONAL RESPONSIBILITIES FOR THE PROPER EXECUTION OF THE CONSTRUCTION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO ESTIMATING, PURCHASING, LABOR COORDINATION, COST SCHEDULE, QUALITY, SAFETY, GENERAL MANAGEMENT FOR THE PROJECT AND SUBSEQUENT WARRANTY AND LIABILITY ISSUES. 11. CONSTRUCTION DETAILS ARE PROVIDED FOR DESIGN INFORMATION AND THE MEANS, METHOD AND FUNCTION OF THE DETAILS AND SYSTEMS ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SUB-CONTRACTORS. 12. PROVIDE ALL NECESSARY BLOCKING IN ALL STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO TOILETS, TOILET ACCESSORIES, CEILING AND WALL MOUNTED ELECTRICAL FIXTURES, SHELVES, CLOSEST RODS, CABINETRY, COUNTERTOPS, STAIR HANDRAILS, GRAB BARS, RAILINGS, AND FALSE BEAMS. 13. THE CONTRACTOR SHALL PROVIDE SAFETY GLAZING PER INTERNATIONAL BUILDING/RESIDENTIAL CODE REQUIREMENTS, SECTION R308.4. 14. THE CONTRACTOR SHALL PROVIDE WINDOW FALL PROTECTION PER INTERNATIONAL BUILDING/RESIDENTIAL CODE REQUIREMENTS, SECTION R312.2. 15. ALL WINDOW AND DOOR HEADER HEIGHTS AND HEADER HEIGHTS TO BE VERIFIED ONCE MANUFACTURER(S) IS/ARE SELECTED. 16. LOCATE ALL TRANSITIONS FROM CARPET TO TILE, VINYL, OR WOOD AT INTERIOR DOORS UNDER THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION. 17. CONTRACTOR TO INSTALL SMOKE ALARMS IN ACCORDANCE WITH IRC R314.3 SMOKE ALARMS TO BE INTERCONNECTED IN ACCORDANCE WITH IRC R314.4. WHERE NATURAL GAS, PROPANE, OR OTHER FOSSIL-BURNING FUELS, INCLUDING WOOD, ARE USED IN THE RESIDENCE, OR THE RESIDENCE HAS AN ATTACHED GARAGE, CARBON-MONOXIDE DETECTORS SHALL ALSO BE PROVIDED PER SECTION R315. COMBINATION SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS MAY BE USED IN ACCORDANCE WITH IRC SECTIONS R314 AND R315. 18. PROVIDE FOR A STANDARD 13-R RESIDENTIAL FIRE SUPPRESSION SYSTEM THROUGHOUT THE ENTIRE HOUSE AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. SYSTEM TO BE DESIGN-BUILD BY THE FIRE SUBCONTRACTOR. SHOP DRAWINGS TO BE PROVIDED TO THE ARCHITECT, AND LOCAL JURISDICTION AS REQUIRED, FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OF THE FIRE SUPPRESSION SYSTEM. 19. CONTRACTOR SHALL BE RESPONSIBLE FOR FOLLOWING ALL RULES AND REGULATIONS THAT APPLY TO THIS PROPERTY, INCLUDING BUT NOT LIMITED TO REQUIREMENTS OF THE INTERNATIONAL BUILDING/RESIDENTIAL CODE, OSHA, AND AUTHORITIES HAVING JURISDICTION. PROJECT INFORMATION LEGAL DESCRIPTION: SECTION: 18 TOWNSHIP: 10 RANGE: 84 LAND BEING A PORTION OF MASCOTTE LODE USMS 5867 SIT IN NW4NE4 OF SEC 18-10-84 CONT 2,690 SQ FT M/L DESC BY M/B 0% 0 ACRESOF THE MASCOTTE LODE USMS #5867 PROJECT DESCRIPTION SINGLE FAMILY 2 STORY REMODEL WITH MAIN LEVEL ADDITION ADDRESS: 325 PARK AVE. ASPEN, CO 81611 PARCEL NO: 273718100211 ACCOUNT NO: R009780 OWNER: WIEZBOWSKI SHARON A & STEPHEN L REV TRUST 151 ALICE B TOKLAS PL #109SAN FRANCISCO, CA 94109 AUTHORITIES HAVING JURISDICTION(AHJ): CITY OF ASPEN, COLORADOPITKIN COUNTY, COLORADO STATE OF COLORADO ASBESTOS ABATEMENT VICINITY MAP DATUM REFERENCE 7949.66' ON THE SITE PLAN/SURVEY = 100'-0" ON THE DRAWINGS 325 PARK AVE. ZONING AND BUILDING CODE INFORMATION APPLICABLE CODES: 2015 IRC, 2015 IECC, 2014 NEC ZONING INFORMATION: ZONING R15-A HEIGHT LIMIT 25'-0"FRONT YARD SETBACK 25'-0"SIDE/REAR YARD SETBACK 10'-0"LOT AREA 15,497 SQ FTALLOWABLE FLOOR AREA 4,530 SQ FT BUILDING TYPE AND OCCUPANCY TYPE OF PROJECT: SINGLE FAMILY RESIDENTIAL TYPE OF BUILDING: TWO-STORY PLUS BASEMENTTYPE OF CONSTRUCTION: V-B OCCUPANCY: IRC, SINGLE FAMILY RESIDENTIAL (R-3) FIRE SUPPRESSION: YES FIRE AREA:7,892.5 SQ FTSNOWMELT: YES SNOWMELT AREA: 1,560.5 SQ FT DESIGN CRITERIA PER CITY OF ASPEN GROUND SNOW LOAD:100 PSF WIND SPEED/EXPOSURE CATEGORY 89/B SEISMIC DESIGN CATEGORY CWEATHERINGSEVERE FROST LINE DEPTH 36"TERMITE 0 - SLIGHT DECAY 0 - SLIGHTWINTER DESIGN TEMP.-15 DEG. F SUMMER DESIGN TEMP.82 DEG. FICE SHIELD UNDERLAYMENT REQ. YES FLOOD HAZARDS SEC. 8.20.020(bb)AIR FREEZING INDEX 2000 MEAN ANNUAL TEMPERATURE 40 DEG. F INTELLECTUAL PROPERTY ALL COPYRIGHTABLE WORK PROVIDED SHALL BE CONSIDERED "INTELLECTUAL PROPERTY." F&M ARCHITECTS LLC HOLDS AN INTEREST IN THE INTELLECTUAL PROPERTY THAT IS PROVIDED. REUSE OF ANY PORTION OF SERVICES PROVIDED IS PROHIBITED WITHOUT WRITTEN CONSENT OF F&M ARCHITECTS LLC. SUPPLEMENTAL REPORTS REFER TO SUBSOIL STUDY FOR FOUNDATION DESIGN FOR PROPOSED RESIDENCE AT 325 PARK AVE., ASPEN, COLORADO, AS PREPARED BY HP GEOTECH/KUMAR & ASSOCIATES, JOB NO. 112 036A, DATED MARCH 30, 2012. SUR SURVEY CMP A1.1A1.2 A2.1A2.2A2.3 A2.5A2.6A2.7 A3.1A3.2 A3.3A3.4 B.4 CONSTRUCTION MANAGEMENT PLAN ARCHITECTURAL SITE PLANSTREAM MARGIN REVIEW PLAN EXISTING MAIN LEVEL PLANEXISTING UPPER LEVEL PLANEXISTING ROOF PLAN PROPOSED MAIN LEVEL PLANPROPOSED UPPER LEVEL PLANPROPOSED ROOF PLAN EXISTING EXTERIOR ELEVATIONSEXISTING EXTERIOR ELEVATIONS PROPOSED EXTERIOR ELEVATIONSPROPOSED EXTERIOR ELEVATIONS RENDERINGS TRIANGLE HOUSEINFORMATION JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021G1.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION 22 23 UP KITCHEN 104 W / D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING FOYER 101 WASTE T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-03D-05D-05D-01D-023/4 BATH 106D-04Stor. 109 7"built-inSTAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. Foyer 101'-0 3/4" T.O. GRAVEL 100'-10" 7949'-3 3/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP CS1 2 3 4 5 6 77945 795079 5 0 7 9 4 9 79 4 8 794879477941GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARD7949PARK AVENUE 10'- 0 " RE A R Y A R D 18'X9' DUMPSTER PROPOSED SITE PLAN Scale: 1/4" = 1'-0"3 CONSTRUCTION SAFETY FENCING W/ ENTRANCE GATE AND EMERGENCY ACCESS WC CONSTRUCTION SAFETY FENCING W/ ENTRANCE GATE AND EMERGENCY ACCESS 18'X9' PARKING 18'X9' PARKING STORAGEX SILT FENCE + WADDLE SILT FENCE + WADDLE AREA OF DISTURBANCETRIANGLE HOUSECONSTRUCTION MANGEMENT PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021CMP325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION CONSTRUCTION MANGEMENT NOTES: 1. INSTALL CONSTUCTION SAFETY FENCING JUST INSIDE ALL PROPERTY LINES. 2. PROVIDE SILT FENCE AND WADDLE ON NORTH AND SOUTH PROPERTY LINES. 3. MAINTAIN DUST CONTROL ON TO PARK AVE. 24 UP KITCHEN 104 W / D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING FOYER 101 WASTE T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-03D-05D-05D-01D-023/4 BATH 106D-04Stor. 109 7"built-inSTAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. Foyer 101'-0 3/4" T.O. GRAVEL 100'-10" 7949'-3 3/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP CS1 2 3 4 5 6 77945 795079 5 0 7 9 4 9 79 4 8 794879477941GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARD7949PARK AVENUE 10'- 0 " RE A R Y A R D TREE TABLE TREE ID#TREE TYPE TRUNK DIAMETER DRIP LINE RADIUS 1 DECIDUOUS 7"9' 2 DECIDUOUS 9"9' 3 DECIDUOUS 13"15' 4 DECIDUOUS 7"8' 5 DECIDUOUS 7"6' 6 EVERGREEN 9"9' 7 EVERGREEN 10"8' EXISTING STRUCTURE NEW ENTRY PROPOSED SITE PLAN Scale: 1/4" = 1'-0"1 NEW LIVING EDGE OF STREAM MARGIN LINE EXISTING RETAINING WALL 28.7 SF UPPER LEVEL - EXISTING 20.9 SF MAIN LEVEL - EXISTING 1.7 SF MAIN LEVEL - NEW 38 SF PATIO - NEW EXTERIOR SCONCE(DARK SKY COMPLIANT) EXTERIOR SCONCE(DARK SKY COMPLIANT) 63'-2 1/2"5'-0"OFFSET TO FRONT FACADE16'-2"20'-8 1/4"5'-7 1/2"16'-11 1/2"9'-4 3/4" PROPOSED 2-STORY ADDITION PROPOSED 1-STORY ADDITION EXISTING BUILDING PROPOSED 1-STORY CARPORT FLAT ROOF ABOVE 29'-10 1/2"PRINCIPAL BUILDING DEPTH46'-2 1/4" EXTERIOR SCONCE(DARK SKY COMPLIANT)TRIANGLE HOUSESITE PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A1.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION GENERAL SITE PLAN NOTES: 1. VERIFY ALL DIMENSIONS IN FIELD 2. 100'-0" = 7948.45' ABOVE SEA LEVEL 25 vasSF- Qm1000OaQOo- omm }gymmQOmrri-OmmSao1I m - a `0SMN ImSm °• NaxamO02F- 0 .. 1ONm31R' mmxSrr00: m0 - S- 10:000N((r1Fi-N0 a0E- mF-Rimama-F-00O. NSOFmxm>. F-00 - 10 .1- 0 - aNm0oD0Mcoq0SmQO° 0gI-oF- a¢ SmOm m ° U. SQm -} 1tySOQ ~ OWWaOz }F- F- I2m07C01SsNSIr0HS2QQm0NF- QOQImWF- F- QFF- mQmN} _2QA- OF- IMN¢ SOSx2wmmoo- mmaal1WFa1ONVa0- ax0FU' mW ¢. W1F-1NatI1ppq 1 RfFSSmU.0am0a0OS . .}•' ¢mmomaM , MCosF- °_xmNOQNmSON - QSS - WMt -O00 _SN1 - fr'4N } ONrrIr 'x _¢ mNd ¢v - 1rr0F0-QNNos ¢ 00rrSI_ F- 0rr . F- a- 7QNmma,Q0SOOa1NmayaFF - 7N F- SWN1QF-OrrN \aS1FQ >U'00om0NmaW- O0QF-02mSO02amm1crso- 0mSP.S¢Nxcr.m0anvV0¢ rrS >S00mF-mW ~ mdmNommD0Um'114S11mF -t-F -Nc00mOf.- NNNNOmcoOSF- Vro ° sosms0M< -DoFo4 'NoWs } sJaF' VI00INmN , SF- a2SOaU.6O_ t! < 0- QSWSm0NOrrSmmSNSSr0r10x4MRMC/Ia <°h_ F- ws. - mmmol- wo: OU' 1 ( , J1SWFSO < aaSNSO (0m /F- 1!°rQSCJN- OdSafw0oma ¢cIrs01 /H - mF-. VSSfUF- CD0WRS0IasxNC0aNxMazmmMiJv m01CDmSmm0NSi4(0C0smN >- IC7r4k'"71'11MMrrF- eAellIlJ1 /1dmmf SJamCT- VO4ow0 - oJa3Pc4Foo \a ® F- w6=4 m ® P..aalK3NJA3W32n. .P QNR• _moe. PCTSy0\ 0m FOAoGQO \ o ,y FOeFaQomMmC7mmiIan1 l./\ \ Vi° P • C) Ste ' .iInIIrLIS ^/J /IIIV1Ir - i SI - ( - lj i ' 7X40 0oaG00M0 _ CS \ \ H < N:EbmmOOaOF- \ \MlMCOjQNN F— 0OIiJ \yF /!0NWicyObN®YErooD\14-1dJana \\ bJ 'a`SPcnraFelPao\ ''•. Ja ` r8 mSvm< 1Ox0r 1a ¢OZNNa .aaa \\ 4K4RoL> N .1SerIYa ' rGaC) z 41ifAo-OF— — 6d' v' o ' xt- . 6 FJiPOPoq' vOII a ' S' maYQS0.fvsNQ\ ~ ITI j ° m / oz -- IfQmjp' C7fTlI ISdr/' nN ` r' pOO . 0DbcmCJFr63o-1O5 .ei: QNS °5sI.kzomIpama1b 4mI0.1O ® m1N4SOmI - ~N3 .NF-KZo / TMOO ¢3m¢3s - NNrrNO1 - IIIJJJ °• OM <oSNtornaoNo /00NOCOS - -SmCYISfWriSmNNQNt1NON40 (T /oQ /FNUJotjAmtj0 __y00Ozo°`P =roossaomrF- oMomiov :¢ ooF1Qo0M. \\ ( 7F + F-F -mo7HlrFF- N` SNxsNQ¢ - -hJSIM wtr <MMU'- SNolm3aNm ~ _° -mmNmlomONmFrr" - moI > ¢ cai o_ ° >mI } > F- F- -S -F- F-1Q - S } F- } } lS00 .+ - } } cum - N }1OQNO' OOF- moI1N¢ FS100Om. OC\)m :. rr .11frQ> fOR , m0QmON1I ° msC } INPNNRCn °j3' '1J , 1 N 0 ( m - SmF • 0- 0 - 10300 - NOmO /{Ix ° O >. m } SSoom- R'- SSSWR' xoR' > F- + mA F-} moNF- S ¢ U' gmvvommmSOS ¢ SO `fOFdi'SaFFFmomxxo ° W --IrWO ¢ xWm0NaN - Q¢ O }mSSmOa _ NdSWQmbFI- x°mcauoSmB • vXmmSfr` + G; s= SSs¢ }sSmmNS$rI— "'•N,'QO' SmOImm °7O0-1 ¢U' - aO iJ1.. CZ ~mS°F-0'mmQO ~40N1F-mOm --101S- !(*i,Yt; ..( OOaO °aF " xMOaSF- v000: Q7000' 1 •M>` C..'A; i0;0frOgazbNm _ !XNS60Q100SHS_ NNIF2WOo- Iir> O <>VQQS_CF-O00 ¢ om1mmOSmNt_ NO ,( '; Sv _SC4 4m1W1O' mfrF- ? SWNsQ - ; m > OmN WIPfi•. i:'Q1mIFQn7SQ. am0¢ OONFR' xm3S ' } NOazaz > F (} :`:• F21OOQmF-sF-} amNioOSOmF- vI . mmmI > m =I- fMm mmm0N7SmS ¢m } _N10Qi ; vNm0 -yS ¢ ° _ ~xoommO1 ' ° oSQ> m ° QaQOO' 1F- /11S> }xm INfF2IN 2RNONE1 -FIT -Qin- CDImOSNX: -0fmNmmaa' 0x > mNIAISOO : mm6QMm ;; S0" ANU' F -S -2ffQmfi•1Fvwmo <= mU - aNmaa0: F- "cvso ° ' > rIm me -- -`GFS-1_ U'. -mt- P.- oa =OORR_77 [[rr77COWH- NmQsNWR - is0Rs (V ~ 3Dam ; 30F - m93SF - SmS¢ 11m -3 ¢ m ¢ 1 ¢a0 •- ¢YR •- Q0 ° oSaWW ¢ O '1= 0m -N >gSW ° fx +l1S -coomwmmNm _0 > 1NsrIxmDO -oSmoFamavo¢ mZ:mmWMwFCACd-aCDM0S00rO> F-OF•• INFofORNN - aNI -ONQmmMoto00} 00m¢ OmNFsaF - ?OQ > } I> Ir ~ oQRO-1CA °; 1;° NQS1moWlmQMa' > =`O 0VOmsmF- 0F- < a1mNNVINNMSSmmCroOXNo } OINamfrOm - mmvyg - ao -mSasr1;FF-QSWaN> mpSFSCJNmSom> mNwarxmom m > maMmOQ> } j ~ mX > OR1sOSRsa} I1- NMNSVUx..Q1¢- msumF-31_ 3OmvFOaoaaOzOSNSNO ,oN =F- F- OOO, NmF- U:oo1xm¢mIxNM0UoSQQsmoOU• - Q• y1 !-R ~ SO0N0NmmSQQ > orro -oN 'IaQOnmFarmmo ~ !ovioEDaoSiSm1Ooozrr01omxo1mCDmmxSaVgNFISoIamvsIsJVANnmnW6dWONsI • ® NNmd1mw3Nap10QONmLSiSL2SILKK1I1aNmwmW _ Aam0mQo mSpUSF- SITvma0mmxF-m :MCDmsomrrMmIZm ~imtJ1 -1Ao °A 0OsbCSmCDMMm ° mlSOMQQmmmrrSOmI- WmzOQQSm - OHN0moF- 0 ¢mmmF-F-SS0S0 > N1myO . rm; 20OjF - 3mS - x1 - F - N ° mNG ; mQypm7: F- 02rr { FF- 10oIof= -amF3VjI 'I >- x2wQmF- ;xommMNYIhm } QMm ¢ m QmF- .f0Z ¢ R -' IoYmeS ¢ SOU' - QMOmazIIS _xMOO¢ mIm~FINooS- F-mNama0iI- mmQ >S~ : ITNH >I ¢ vmpF ¢ QVm rOoNSmy1NcuM - 1QamcaI F - n;S ~ NOQ 1• CQQniN- xNNVi0IMGmC/Im }FoNOFQa SCJNO3mIrQ °N¢F"w0oDXS NQ - MMM' Q1mSNmMS <h-- NSNmaNOU•m}SF -OaF-0Fpm0scQS MQQaScSi¢O QSSr9M10UStrs¢ 0N .. jF- mN0s = mor°rF -FS- <~ CtjWoNOSmA) } p-MQSWMomNF0om- QNQ — VSaF ° V nf- NOOQF ° °gymmmcv4ODmS0OsSfIl rVCA4192:< m0rVJ SpSamSwwv44mmcrNN7 .ITlNNQ 000 M OQORmcuuzrrm >m1OOQmmcav0W¢ mmQmmmmSc1v •- 00U' >aNN ¢0aWm> NNms1 - mmmmo00Cmmmmm mmm, -, OOFOO3FOC0WWmOzI-- - IONOQQ2° NmommSQCN NmmUU' Orm ¢NmQQOQy2aF-,CaCD -mNmm- _mQQS¢ QQOU"SqSSNNQf7QQ• 1- NooW -10mCJmNN0ONNNN >mSSQ22SelNIxMO1U'crhQF. Qm001QOS }O ° fic0sM _gip° NmQQ¢ OOmQ0OrrmcrmU•mSS -m000Mmm -. ~NQQQFF- }fm*1vvOO Q1F1- _0SmOm011a22avv0mm:E °sNOIFSN OSm0aSSOm ¢ v -vmjaQQsNNNU,NSSSmfmySSmw2mOOQ"MANO1S01r mFQOO111 ,wSS=1-- 0O >4uz0a °mWII< aaWUU• USNNO00M0F -0RU- COOFSamMmm0E-SQmmsQQ 0QmmWONFF -F-M"W - SSOmF- mmaO.T00NN }ps01.0- _NN 4QOmd22xm0F- 00 -Omv' a> ,mmmmsSiiS- ssm003oQ3oQQ vv= FF mmxrmos -omQr >oou0 -QmQ F- WF-Wmm -F- QQmFFSN •- »m0N0 mm } °m0SS1=} FF00xvv0mmFFp ` F2 - 1WxfcrR}iI- NNI- ixUOmymmmvv0SaNmF - QmmN0I000OaQOo- omm }gymmQOmrri-OmmSao1I m - a `0SMN ImSm °• NaxamO02F- 0 .. 1ONm31R' mmxSrr00: m0 - S- 10:000N((r1Fi-N0 a0E- mF-Rimama-F-00O. NSOFmxm>. F-00 - 10 .1- 0 - aNm0oD0Mcoq0SmQO° 0gI-oF- a¢ SmOm m ° U. SQm -} 1tySOQ ~ OWWaOz }F- F- I2m07C01SsNSIr0HS2QQm0NF- QOQImWF- F- QFF- mQmN} _2QA- OF- IMN¢ SOSx2wmmoo- mmaal1WFa1ONVa0- ax0FU' mW ¢. W1F-1NatI1ppq 1 RfFSSmU.0am0a0OS . .}•' ¢mmomaM , MCosF- °_xmNOQNmSON - QSS - WMt -O00 _SN1 - fr'4N } ONrrIr 'x _¢ mNd ¢v - 1rr0F0-QNNos ¢ 00rrSI_ F- 0rr . F- a- 7QNmma,Q0SOOa1NmayaFF - 7N F- SWN1QF-OrrN \aS1FQ >U'00om0NmaW- O0QF-02mSO02amm1crso- 0mSP.S¢Nxcr.m0anvV0¢ rrS >S00mF-mW ~ mdmNommD0Um'114S11mF -t-F -Nc00mOf.- NNNNOmcoOSF- Vro ° sosms0M< -DoFo4 'NoWs } sJaF' VI00INmN , SF- a2SOaU.6O_ t! < 0- QSWSm0NOrrSmmSNSSr0r10x4MRMC/Ia <°h_ F- ws. - mmmol- wo: OU' 1 ( , J1SWFSO < aaSNSO (0m /F- 1!°rQSCJN- OdSafw0oma ¢cIrs01 /H - mF-. VSSfUF- CD0WRS0IasxNC0aNxMazmmMiJv m01CDmSmm0NSi4(0C0smN >- IC7r4k'"71'11MMrrF- eAellIlJ1 /1dmmf SJamCT- VO4ow0 - oJa3Pc4Foo \a ® F- w6=4 m ® P..aalK3NJA3W32n. .P QNR• _moe. PCTSy0\ 0m FOAoGQO \ o ,y FOeFaQomMmC7mmiIan1 l./\ \ Vi° P • C) Ste ' .iInIIrLIS ^/J /IIIV1Ir - i SI - ( - lj i ' 7X40 0oaG00M0 _ CS \ \ H < N:EbmmOOaOF- \ \MlMCOjQNN F— 0OIiJ \yF /!0NWicyObN®YErooD\14-1dJana \\ bJ 'a`SPcnraFelPao\ ''•. Ja ` r8 mSvm< 1Ox0r 1a ¢OZNNa .aaa \\ 4K4RoL> N .1SerIYa ' rGaC) z 41ifAo-OF— — 6d' v' o ' xt- . 6 FJiPOPoq' vOII a ' S' maYQS0.fvsNQ\ ~ ITI j ° m / oz -- IfQmjp' C7fTlI ISdr/' nN ` r' pOO . 0DbcmCJFr63o-1O5 .ei: QNS °5sI.kzomIpama1b 4mI0.1O ® m1N4SOmI - ~N3 .NF-KZo / TMOO ¢3m¢3s - NNrrNO1 - IIIJJJ °• OM <oSNtornaoNo /00NOCOS - -SmCYISfWriSmNNQNt1NON40 (T /oQ /FNUJotjAmtj0 __y00Ozo°`P =roossaomrF- oMomiov :¢ ooF1Qo0M. \\ ( 7F + F-F -mo7HlrFF- N` SNxsNQ¢ - -hJSIM wtr <MMU'- SNolm3aNm ~ _° -mmNmlomONmFrr" - moI > ¢ cai o_ ° >mI } > F- F- -S -F- F-1Q - S } F- } } lS00 .+ - } } cum - N }1OQNO' OOF- moI1N¢ FS100Om. OC\)m :. rr .11frQ> fOR , m0QmON1I ° msC } INPNNRCn °j3' '1J , 1 N 0 ( m - SmF • 0- 0 - 10300 - NOmO /{Ix ° O >. m } SSoom- R'- SSSWR' xoR' > F- + mA F-} moNF- S ¢ U' gmvvommmSOS ¢ SO `fOFdi'SaFFFmomxxo ° W --IrWO ¢ xWm0NaN - Q¢ O }mSSmOa _ NdSWQmbFI- x°mcauoSmB • vXmmSfr` + G; s= SSs¢ }sSmmNS$rI— "'•N,'QO' SmOImm °7O0-1 ¢U' - aO iJ1.. CZ ~mS°F-0'mmQO ~40N1F-mOm --101S- !(*i,Yt; ..( OOaO °aF " xMOaSF- v000: Q7000' 1 •M>` C..'A; i0;0frOgazbNm _ !XNS60Q100SHS_ NNIF2WOo- Iir> O <>VQQS_CF-O00 ¢ om1mmOSmNt_ NO ,( '; Sv _SC4 4m1W1O' mfrF- ? SWNsQ - ; m > OmN WIPfi•. i:'Q1mIFQn7SQ. am0¢ OONFR' xm3S ' } NOazaz > F (} :`:• F21OOQmF-sF-} amNioOSOmF- vI . mmmI > m =I- fMm mmm0N7SmS ¢m } _N10Qi ; vNm0 -yS ¢ ° _ ~xoommO1 ' ° oSQ> m ° QaQOO' 1F- /11S> }xm INfF2IN 2RNONE1 -FIT -Qin- CDImOSNX: -0fmNmmaa' 0x > mNIAISOO : mm6QMm ;; S0" ANU' F -S -2ffQmfi•1Fvwmo <= mU - aNmaa0: F- "cvso ° ' > rIm me -- -`GFS-1_ U'. -mt- P.- oa =OORR_77 [[rr77COWH- NmQsNWR - is0Rs (V ~ 3Dam ; 30F - m93SF - SmS¢ 11m -3 ¢ m ¢ 1 ¢a0 •- ¢YR •- Q0 ° oSaWW ¢ O '1= 0m -N >gSW ° fx +l1S -coomwmmNm _0 > 1NsrIxmDO -oSmoFamavo¢ mZ:mmWMwFCACd-aCDM0S00rO> F-OF•• INFofORNN - aNI -ONQmmMoto00} 00m¢ OmNFsaF - ?OQ > } I> Ir ~ oQRO-1CA °; 1;° NQS1moWlmQMa' > =`O 0VOmsmF- 0F- < a1mNNVINNMSSmmCroOXNo } OINamfrOm - mmvyg - ao -mSasr1;FF-QSWaN> mpSFSCJNmSom> mNwarxmom m > maMmOQ> } j ~ mX > OR1sOSRsa} I1- NMNSVUx..Q1¢- msumF-31_ 3OmvFOaoaaOzOSNSNO ,oN =F- F- OOO, NmF- U:oo1xm¢mIxNM0UoSQQsmoOU• - Q• y1 !-R ~ SO0N0NmmSQQ > orro -oN 'IaQOnmFarmmo ~ !ovioEDaoSiSm1Ooozrr01omxo1mCDmmxSaVgNFISoIamvsIsJVANnmnW6dWONsI • ® NNmd1mw3Nap10QONmLSiSL2SILKK1I1aNmwmW _ Aam0mQo mSpUSF- SITvma0mmxF-m :MCDmsomrrMmIZm ~imtJ1 -1Ao °A 0OsbCSmCDMMm ° mlSOMQQmmmrrSOmI- WmzOQQSm - OHN0moF- 0 ¢mmmF-F-SS0S0 > N1myO . rm; 20OjF - 3mS - x1 - F - N ° mNG ; mQypm7: F- 02rr { FF- 10oIof= -amF3VjI 'I >- x2wQmF- ;xommMNYIhm } QMm ¢ m QmF- .f0Z ¢ R -' IoYmeS ¢ SOU' - QMOmazIIS _xMOO¢ mIm~FINooS- F-mNama0iI- mmQ >S~ : ITNH >I ¢ vmpF ¢ QVm rOoNSmy1NcuM - 1QamcaI F - n;S ~ NOQ 1• CQQniN- xNNVi0IMGmC/Im }FoNOFQa SCJNO3mIrQ °N¢F"w0oDXS NQ - MMM' Q1mSNmMS <h-- NSNmaNOU•m}SF -OaF-0Fpm0scQS MQQaScSi¢O QSSr9M10UStrs¢ 0N .. jF- mN0s = mor°rF -FS- <~ CtjWoNOSmA) } p-MQSWMomNF0om- QNQ — VSaF ° V nf- NOOQF ° °gymmmcv4ODmS0OsSfIl rVCA4192:< m0rVJ SVgNFISoIamvsIsJVANnmnW6dWONsI • ® NNmd1mw3Nap10QONmLSiSL2SILKK1I1aNmwmW _ Aam0mQo mSpUSF- SITvma0mmxF-m :MCDmsomrrMmIZm ~imtJ1 -1Ao °A 0OsbCSmCDMMm ° mlSOMQQmmmrrSOmI- WmzOQQSm - OHN0moF- 0 ¢mmmF-F-SS0S0 > N1myO . rm; 20OjF - 3mS - x1 - F - N ° mNG ; mQypm7: F- 02rr { FF- 10oIof= -amF3VjI 'I >- x2wQmF- ;xommMNYIhm } QMm ¢ m QmF- .f0Z ¢ R -' IoYmeS ¢ SOU' - QMOmazIIS _xMOO¢ mIm~FINooS- F-mNama0iI- mmQ >S~ : ITNH >I ¢ vmpF ¢ QVm rOoNSmy1NcuM - 1QamcaI F - n;S ~ NOQ 1• CQQniN- xNNVi0IMGmC/Im }FoNOFQa SCJNO3mIrQ °N¢F"w0oDXS NQ - MMM' Q1mSNmMS <h-- NSNmaNOU•m}SF -OaF-0Fpm0scQS MQQaScSi¢O QSSr9M10UStrs¢ 0N .. jF- mN0s = mor°rF -FS- <~ CtjWoNOSmA) } p-MQSWMomNF0om- QNQ — VSaF ° V nf- NOOQF ° °gymmmcv4ODmS0OsSfIl rVCA4192:< m0rVJ SC S1234567 E 794 5 79 5 0 7950794979487948 7947 79 4 1 GRAVEL PARKINGGRAVEL PARKINGEDGE OF PAVEMENT5'- 0 " SID E Y A R D 10'-0" FRONT YARD 7949PARK AVENUE10'-0"REAR YARDUPKITCHEN104W/DLIVING102DINING105Carport101OFF STREET PARKINGFOYER101WASTET.O. BRICK100'-0" (7948.45)T.ROAD(7947.69)D-03 D-05 D-05 D-01D-023/4 BATH106D-0 4 Stor.1097"built-in STAIRS107PANELS &METERSWaste/Stor.108T.O. BRICK 99'-5"UPUPDNT.O. BRICK 100'-0" 7948'-5 3/8"T.O. Foyer101'-0 3/4"T.O. GRAVEL100'-10" 7949'-3 3/8"T.O. GRAVEL100'-11 3/4" 7949'-5 1/8"T.O. GRAVEL100'-11 3/4" 7949'-5 1/8"T.O. CONC. 100'-0" 7948'-5 3/8"T.O. GRAVEL100'-11 3/4"UPUPEXISTINGSTRUCTUREGRAVEL - DESIGNATED OFF STREET PARKINGNEW ENTRYTOP OF SLOPE & STREAM MARGIN EXHIBIT Scale: 1/8" = 1'-0"1 NEW LIVINGEDGE OF STREAM MARGIN LINE EXISTING FENCE TO BE REMOVED15' TOP OF SLOPE SETBACK 2 A1.2 2 A1.2 TRIANGLE HOUSESTREAM MARGIN REVIEW PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A1.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION STREAM MARGIN SITE SECTION SCALE: 1/8" = 1'-0"2 T.O. SLAB @ MAIN LEVEL 100'-0" T.O. PLY @ UPPER LEVEL 107'-11 7/8" 7948'-0" 7947'-0" 7946'-0" 7945'-0" 7944'-0" 7943'-0" 7942'-0" 7941'-0" 7940'-0" 7939'-0" 7938'-0" 7937'-0" 7936'-0" 7935'-0" 7934'-0" 7933'-0" 15'-0" SETBACK45.0 °top of slopeproperty lineproperty line100'-0" = 7948.45' T.O. SLAB @ MAIN LEVEL 7948'-5 3/8" 26 TRIANGLE HOUSEEXISTING MAIN LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D -2' - 0" -1' - 6" -1' - 0" - 0 ' - 6 " -6' - 0" -5' - 6" -5' - 0" -4' - 6" -4' - 0" -3' - 6" -3' - 0" -2' - 6" -2' - 0" -1' - 6" -1' - 0" -0' - 6" 0' - 0" EDGE OF ASPHALT SETBACK LINE PROPERTY LINE EXISTING YARD GRAVEL MAILBOX EXISTING FENCE UPGRAVEL - DESIGNATED OFF STREET PARKING STAIRS UP TO ENTRANCE STAIRS DOWN TO ENTRANCE DOWNR E F DIS H 10' - 0"10' - 0"5' - 0"10' - 0" 10' - 0" SEATING AREA KITCHEN BATH UTILITY / HALL W / D PARK AVENUE A0.06 1 A0.04 1 A0.05 1 Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.01Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Level 1 As-Built 5'-0 " 5'-0 " 5'-0 " EXISTING MAIN LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 27 TRIANGLE HOUSEEXISTING UPPER LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D DN BEDROOM CLOSET ANTE ROOM HALL STEPS DOWN TO ENTRANCE OF LEVEL 1 ENTRANCE TO LEVEL 2 SETBACK LINE PROPERTY LINE LEVEL 1 CONTOUR LINE EXISTING FENCE BUILT-IN STORAGE CABINET EDGE OF ASPHALT PARK AVENUE A0.06 1 A0.04 1 A0.05 1 Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.02Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Level 2 As-Built 5'-0 " 5'-0 " 5'-0 " EXISTING UPPER LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 28 TRIANGLE HOUSEEXISTING ROOF LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.3325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D ADJACENT 2-STOREY GARAGE & HOUSE ABOVE GRADE DECK ADJACENT GARAGE Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.03Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Roof Plan As-Built 5'-0 " 5'-0 " 5'-0 " EXISTING ROOF PLAN Scale: 1/4" = 1'-0"2 E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 29 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D UP KITCHEN 104 W / D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING1'-0"O.C.typChinese CabinetFOYER 101 A R T W A L L 7' - 4 3 / 4 " 2' - 1 1 / 2 " BENCH WASTE ART WALL 6'-0"1'-0"12'-9 1/4" 9'-8 1/4" T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-03D-05D-05D-01D-023/4 BATH 106D-04Stor. 109 7" 32° 5 8 ° 5 8 ° 5'-11"built-in90°5'-2 3/4"STAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. Foyer 101'-0 3/4" T.O. GRAVEL 100'-10" 7949'-3 3/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-0 " 5'-0 " 5'-0 " PROPOSED MAIN LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 29'-10 1/2"PRINCIPAL BUILDING DEPTHTRIANGLE HOUSEMAIN LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.5325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION 30 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 Anteroom 203 ANTEROOM 203 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 Bedroom 201 BEDROOM 201 Office 202 Office 202 Office 202 Office 202 Office 202 Office 202 Office 202 Office 202 Office 202 OFFICE 202 Bath 204 Bath 204 Bath 204 Bath 204 Bath 204 Bath 204 Bath 204 Bath 204 Bath 204 BATH 204 Hall 205 Hall 205 Hall 205 Hall 205 Hall 205 Hall 205 Hall 205 Hall 205 Hall 205 HALL 205 T.O. F.F. (Exist.) 107'-11 7/8" BOOKCASE CL. 1'- 7 "8"2'-10 3/4"2'-9"1'-5"6'-8 3/4"Wndw Niche 206 STAIRS 107 T.O. F.F. (Exist.) 107'-11 7/8" 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-0 " 5'-0 " 5'-0 " PROPOSED UPPER LEVEL PLAN Scale: 1/4" = 1'-0"1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 E2E2 E3E3 E4E4 E1E1 S1 S1 N1 N1 S9 S9 N2 N2 TRIANGLE HOUSEUPPER LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.6325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION 31 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'- 0 " REA R Y A R D UP KITCHEN 104 W / D LIVING 102 DINING 105 Carport 101 OFF STREET PARKINGChinese CabinetFOYER 101 BENCH WASTE T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-03D-05D-05D-01D-023/4 BATH 106D-04Stor. 109 7"built-inSTAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. Foyer 101'-0 3/4" T.O. GRAVEL 100'-10" 7949'-3 3/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. GRAVEL 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-0 " 5'-0 " 5'-0 " PROPOSED ROOF PLAN Scale: 1/4" = 1'-0"1REAR YARDFRONT YARD SI D E Y A R D 10'- 0 " RE A R Y A R D S E T B A C K EXISTING NON-CONFORMITY TO REMAIN UNCHANGED (NOT IN THIS SCOPE)10'-0"FRONT YARD SETBACK5'-0"FRONT YARD SETBACK10'-0"FRONT YARD SETBACKUPPER LEVEL, TWO-STORY ROOF #1 MAIN LEVEL, SINGLE-STORY ROOF #1 MAIN LEVEL SINGLE-STORY ROOF #25'-0 " CA R P O R T S E T B A C K 3. One-Story Stepdown. The principal building shall include a one-story component on one (1) side of the building that remains one (1) story from the front façade to the rear wall. The width of the one-story portion shall be a minimum of twenty percent (20%) of the building's (or unit's) overall width. The one-story portion may be fully enclosed and used as living area. Accessible space (whether it is a deck, porch or enclosed area) shall not be allowed over the first story element; however, accessible space over the remaining first story elements on the front façade shall not be precluded. Also reference: 26.410.010.d (d) Remodels. Where work is proposed on any element of an existing building that is addressed by the Residential Design Standards and that is not in compliance with the Standards, the property owner shall make a reasonable effort to bring that element into compliance. The Community Development Director may grant exceptions for remodels that would require significant additional work above and beyond the scope of the remodel in order to ensure that all features are brought into compliance.SIDE YARDE1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 TRIANGLE HOUSEROOF PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A2.7325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION 32 TRIANGLE HOUSEEXISTING EXTERIORELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A3.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.05Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Elevation South-West Existing Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.06Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 East Existing EXISTING EAST ELEVATION SCALE: 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION SCALE: 1/4" = 1'-0"1 T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 100'-0" = 7948.45' 33 TRIANGLE HOUSEEXISTING EXTERIORELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A3.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.04Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Elevation North West Existing EXISTING NORTH ELEVATION SCALE: 1/4" = 1'-0"1 T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 34 SOUTH ELEVATION Scale: 1/4" = 1'-0"2 T.O. WNDW 114'-11 7/8" T.O. CARPORT 110'-5" T.O. GRAVEL @ CARPORT 100'-11 3/4" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. F.F. @ FOYER 101'-0 3/4" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" 100'-0" = 7948.45' T.O. PARAPET 111'-5" EAST ELEVATION Scale: 1/4" = 1'-0"18'-0"S1 S2 S3 S4 S5 S6 S7 S8 S9 B.O. WNDW 110'-5 7/8" Top of Parapet 111'-5" T.O. ROOF @ CARPORT 110'-5" T.O. WNDW 114'-11 5/8" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F,F, @ ENTRY 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. F.F. @ FOYER 101'-0 3/4" T.O. GRAVEL @ CARPORT 100'-11 3/4" 100'-0" = 7948.45'TRIANGLE HOUSEEXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A3.3325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION 35 TRIANGLE HOUSEEXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit2.vwx20064Wednesday, June 16, 2021A3.4325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STREAM & RDS APPLICATION existing grade FIXED SOUTH ELEVATION Scale: 1/4" = 1'-0"1 EXISTING STOVE VENT/EXHAUST TO REMAIN EXISTING MECHANICAL ROOM WALL VENT. ALL EXISTING MECHANICAL EQUIPMENT IS CURRENTLY LOCATED BENEATH EXISTING STAIRS AND WILL REMAIN. T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 36 TRIANGLEHOUSEWednesday, June 16, 2021F & M A R C H I T E C T S 3. One-Story Stepdown. The principal building shall include a one-story component on one (1) side of the building that remains one (1) story from the front façade to the rear wall. The width of the one-story portion shall be a minimum of twenty percent (20%) of the building's (or unit's) overall width. The one-story portion may be fully enclosed and used as living area. Accessible space (whether it is a deck, porch or enclosed area) shall not be allowed over the first story element; however, accessible space over the remaining first story elements on the front façade shall not be precluded. ARIAL PERSPECTIVE ENTRY PERSPECTIVE SOUTH RENDERING EXHIBIT B.437 38 0d[Ojj j $Scgj \Pj !a^O[j#dTWNS[Qj &O^K_cYO[cj j: j *KWO[Kj:c j !b^O[j %7j j 9'j !dcR\_SiKcS\[j c\j !^^XhjP\_j:c_OKZj 5K_QS[j 3K[Nj ?bOj!^^_\eKWjK[Nj#dSXNS[Qj 8O_YScaj \[jLORKWPj\PjA-'B#7A:1-j :+!976j !jj:;'8+'6j 3j9'@j ;9?:<j 3\MKcS\[jj 8K_Vj !eOj !a^O[j $7j j3OQKWj&ObM_S^cS\[j #+*4.106 6$1503-/26 6 ")0,+6  66 6 6 "$6 6 #$$6 6 &##6  6 #$66'  66#6  6$6  6#!6 $6 6#6(6 66 6 "#6$6#%66 &##6  68K_MOWj j ;\j AR\Yj-cj 5Kgj$\[MO_[j ;ROj \f[O_bj ]Pj j8K_Vj!eOj j A.'B#7A:2-j:+!976j !jj:;'8+'6j 4j9(@j;9?:<j K[Nj Scbj \f[O_bj RO_OLgj KdcR\_SiOj )Wg[[j :cOfK` :OeO_gj !-!j \Pj )5j !_MRScOMcaj 33$j :[]fYKbaj @SWXKQOj %7j c\j KMcj\[j RO_jLORKWPj P\_j 3K[Nj ?aOjK[Nj #dSWNS[Qj8O_YScjK^^WSMKcS\[aj Kaa\MSKcONj fScRj cROjKL\eOjKNN_Oab j ![hjN]MdYO[cbjN_KfT[Qaj XK[Nj dbOj K^^_\eKWaj PW]\_j K_OKj bdYYK_UObj OcM j MK[j LOjaRK_ONjP\_j _OeSOfj K[Nj^O_YSccS[Q j :S[MO_OWgj 8_T[cONj:+!976j " j A.(C#7A:1-j <ScWOjDEFGEHIEFGjJjA-'B#7A:1-j:,!976j !jj:;'8+'6j 3j9'@j=9?:>j j"3/%'jj;723":j 83jj :!6j )9!6%.:$7j%!jj 7f[O_j j8K_Vj !eOj 8R\[O   j &KcOj 39 40 41 42 National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOOD HAZARD AREAS Without Base Flood Elevation (BFE) Zone A, V, A99 With BFE or DepthZone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areas of 1% annual chance flood with average depth less than one foot or with drainage areas of less than one square mileZone X Future Conditions 1% Annual Chance Flood HazardZone X Area with Reduced Flood Risk due to Levee. See Notes.Zone X Area with Flood Risk due to LeveeZone D NO SCREEN Area of Minimal Flood Hazard Zone X Area of Undetermined Flood HazardZone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards The flood hazard information is derived directly from the authoritative NFHL web services provided by FEMA. This map was exported on 6/8/2021 at 2:01 PM and does not reflect changes or amendments subsequent to this date and time. The NFHL and effective information may change or become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location. 1:6,000 106°48'55"W 39°11'33"N 106°48'18"W 39°11'6"N Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020 43 44 OWNERSHIP & ENCUMBRANCE REPORT Prepared for: Seller Date:June 8, 2021 Order:0707206-OE Ref: PROPERTY IDENTIFICATION AND OWNERSHIP Legal Description:A portion of the Mascotte Lode M.S. #5867 in the NW1/4 of the NE1/4, Section 18, Township 10 South, Range 84 West of the 6th P.M., City of Aspen, Colorado, more fully described as follows: Beginning at a point on the South end line of said Mascotte Claim from whence Corner No. 1 of the Mascotte bears N 89°46' W 127.9 feet; Thence S 89°46' E 5.00 feet; Thence N 01°36' E 34.50 feet; Thence N 03°05' W 61.71 feet; Thence S 38°00' W 82.86 feet; Thence S 57°31' E 57.34 feet to the point of beginning. Property Address:325 Park Ave, Aspen, CO 81611 County:Pitkin, Colorado Schedule/Parcel #:R009780 Owner s Name(s):The Survivor's Trust, created under the Sharon A. and Stephen L. Wiezbowski Revocable Trust dated December 18, 2009 TITLE ABSTRACT Special Warranty Deed from Sallie Golden to The Survivor's Trust, created under the Sharon A. and Stephen L. Wiezbowski Revocable Trust dated December 18, 2009, recorded September 16, 2020 as Reception No. 668196. Nothing Further of Record Note: This report covers Pitkin County, Colorado Real Estate Records Through May 21, 2021. Disclaimer: This report reflects the results of a search of the c ounty records posted to the above described real estate only, and does not necessarily reflect involuntary liens or other matters which might be disclosed by a search on the individual owner s or other names shown hereinabove. The Title Company of the Rockies makes no warranty regarding the accuracy of the information herein provided, and further, shall not be liable for any loss incurred by reason of the information reported in this report. THE DOCUMENTS INCLUDED WITH THIS REPORT ARE THE BEST COPIES AVAILABLE Eagle, Garfield, Grand, Pitkin and Summit Counties. (Limited Coverage: Jackson, Lake, Park and Routt Counties) Avon/Beaver Creek, Basalt, Breckenridge, Grand Lake and Winter Park. (Closing Services available in Aspen and Glenwood Springs). 45 Account Projects Call What are you shopping for? Item # bci2704133 Progress Lighting Single Light 7" Tall LED Outdoor Cylinder Wall Sconce Model:P5674-31/30K (5)|Write a Review $99.00 FREE Delivery by Thursday If ordered in the next 2 hrs 48 mins -Shipping to 81621 Finish: Black - 1328 In Stock Bl k 0 Shipping to:Basalt, CO COVID-19 Update: Service & Delivery Info Chat 46 Overview Product Overview Cylinder is a worldwide best-selling collection of outdoor light fixtures in both the residential and commercial markets. Fixtures are made of heavy-duty aluminum with powder coated finishes to resist rust and chipping in harsh outdoor environments. Cylinders are available in 5" or 6" diameter for wall or ceiling mounting, and come with medium base sockets or integrated LED engines. Features: Durable and lightweight aluminum material Light output is similar to a 75 watt incandescent bulb Rated for wet locations CA Title 24 compliant 5 year warranty on LED module Dimensions: Height: 7-1/4" Width: 5" Extension: 8" Product Weight: 2.2 Specifications: Bulb Type: LED Bulb Base: Integrated LED Number of Bulbs: 1 Watts per Bulb: 17w Voltage: 120v Color Temperature: 3000K Color Rendering Index (CRI): 90 Lumens: 788 Average Hours: 60000 LED Technology: Chat 47 Height 7.25 in. Width 5 in. Wire Length 6 in. Included Components Bulb Included Yes Wall Control Included No Characteristics and Features Base Color Black, Bronze, Grey, White Bulb Base Integrated LED Bulb Type LED Color Temperature 3000K Dimmable Yes Energy Efficient Yes Full Backplate No Genre Contemporary, Transitional, Modern Light Direction Down Lighting Material Aluminum Number of Bulbs 1 Sconce Type Cylinder Shade Color Black, Bronze, Grey, White Shade Material Metal Shade Shape Cylinder Theme Contemporary, Modern, Transitional Electrical and Operational Information Average Hours 60000 Hours Color Rendering Index (CRI)90 Lumens 1211 Chat 48 Power Source Hardwired Voltage 120 Voltage Type Line Voltage Watt Replacement 75 Wattage 17 Watts Per Bulb 17 Warranty and Product Information ADA No Collection Cylinder Country Of Origin China Dark Sky Yes Energy Star No Location Rating Wet Location Series Progress LED Title 24 Yes UL Listed Yes Related Progress Lighting Categories Browse by Brand Design Series Jeffrey Alan Marks Outdoor Wall Sconces Bathroom Lighting Ceiling Fixtures Ceiling Fans Chandeliers Reviews 5 Chat 49 TRIANGLE HOUSE 325 PARK AVE ASPEN, CO 81611 REMODEL/ADDITION PROJECT #20064 ROW EASEMENT, RDS & BOARD OF ADJUSTMENT REVIEW GENERAL CONTRACTOR STEEPLECHASE CONSTRUCTION, INC 0124 TOTTERDOWN ROAD ASPEN, CO 81611 CONTACT: STEVE WALDECK -(C) 970.379.6268 STRUCTURAL ENGINEER ASCENT GROUP 6707 WINCHESTER CIRCLE, SUITE 100 BOULDER, CO 80301 CONTACT: CHRIS KRAUSS -(O) 303.865.4946 ARCHITECT F&M ARCHITECTS LLC MAIL: PO BOX 6762 PHYSICAL: 15 KEARNS ROAD, SUITE. D SNOWMASS VILLAGE, CO 81615 http://fandmarchitects.com CONTACT: FLYNN STEWART-SEVERY -(O) 970.987.2707 (C) 970.319.4407 November 19, 2021ISSUE DATE 50 UP KITCHEN 104 W /D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING FOYER 101 WASTED-05D-05D-01 D-01D-01 D-01 D-01D-01D-013/4 BATH 106D-04D-03Stor. 109 built-inSTAIRS 107 PANELS & METERSWaste/Stor. 108 UP UP DN UP UP 21'-7 3/4" D-05 RECYCLE OFF STREET PARKING5'-0"FRONT (ROOF)5'-5 7/8" REAR 5'-0"FRONT (ROOF)7'-5 1/4"FRONT (STRUCT)7'-0 5/8"FRONT7'-0"FRONT (STRUCT)5'-4"FRONT (HARDSCAPE)CS1 2 3 4 5 6 77945 79507950 7 9 4 9 7 9 4 8 794879477941GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARD7949PARK AVENUE 10'-0"REAR YARD TREE TABLE TREE ID#TREE TYPE TRUNK DIAMETER DRIP LINE RADIUS 1 DECIDUOUS 7"9' 2 DECIDUOUS 9"9' 3 DECIDUOUS 13"15' 4 DECIDUOUS 7"8' 5 DECIDUOUS 7"6' 6 EVERGREEN 9"9' 7 EVERGREEN 10"8' EXISTING STRUCTURE PROPOSED SITE PLAN Scale: 1/4" = 1'-0"1 EDGE OF STREAM MARGIN LINE EXISTING RETAINING WALL 1.7 SF MAIN LEVEL - NEW 38 SF PATIO - NEW EXTERIOR SCONCE(DARK SKY COMPLIANT) EXTERIOR SCONCE(DARK SKY COMPLIANT) 63'-2 1/2"5'-0"OFFSET TO FRONT FACADE16'-2"20'-8 1/4"5'-7 1/2"16'-11 1/2"9'-4 3/4" PROPOSED 2-STORY ADDITION PROPOSED 1-STORY ADDITION PROPOSED 1-STORY CARPORT FLAT ROOF ABOVE 29'-10 1/2"PRINCIPAL BUILDING DEPTH46'-2 1/4" EXTERIOR SCONCE(DARK SKY COMPLIANT) 20.9 SF MAIN LEVEL - EXISTING 28.7 SF UPPER LEVEL - EXISTING NEW LIVING NEW ENTRY EXISTING BUILDING TRIANGLE HOUSESITE PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A1.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. GENERAL SITE PLAN NOTES: 1. VERIFY ALL DIMENSIONS IN FIELD 2. 100'-0" = 7948.45' ABOVE SEA LEVEL 51 TRIANGLE HOUSEEXISTING MAIN LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD -2' - 0" -1' - 6" -1' - 0" - 0 ' - 6 " -6' - 0" -5' - 6" -5' - 0" -4' - 6" -4' - 0" -3' - 6" -3' - 0" -2' - 6" -2' - 0" -1' - 6" -1' - 0" -0' - 6" 0' - 0" EDGE OF ASPHALT SETBACK LINE PROPERTY LINE EXISTING YARD GRAVEL MAILBOX EXISTING FENCE UPGRAVEL - DESIGNATED OFF STREET PARKING STAIRS UP TO ENTRANCE STAIRS DOWN TO ENTRANCE DOWNR E F DIS H 10' - 0"10' - 0"5' - 0"10' - 0" 10' - 0" SEATING AREA KITCHEN BATH UTILITY / HALL W / D PARK AVENUE A0.06 1 A0.04 1 A0.05 1 Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.01Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Level 1 As-Built 5'-2 1/2" 5'-0" 5'-0" EXISTING MAIN LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 52 TRIANGLE HOUSEEXISTING UPPER LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD DN BEDROOM CLOSET ANTE ROOM HALL STEPS DOWN TO ENTRANCE OF LEVEL 1 ENTRANCE TO LEVEL 2 SETBACK LINE PROPERTY LINE LEVEL 1 CONTOUR LINE EXISTING FENCE BUILT-IN STORAGE CABINET EDGE OF ASPHALT PARK AVENUE A0.06 1 A0.04 1 A0.05 1 Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.02Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Level 2 As-Built 5'-2 1/2" 5'-0" 5'-0" EXISTING UPPER LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 53 TRIANGLE HOUSEEXISTING ROOF LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.3325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD ADJACENT 2-STOREY GARAGE & HOUSE ABOVE GRADE DECK ADJACENT GARAGE Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.03Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Roof Plan As-Built 5'-2 1/2" 5'-0" 5'-0" EXISTING ROOF PLAN Scale: 1/4" = 1'-0"2 E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 54 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD SLAB ON GRADE (EXISTING) SLAB ON GRADE (PROPOSED) SLAB ON GRADE (PROPOSED) GRAVEL SLAB ON GRADE (PROPOSED) 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-2 1/2" 5'-0" 5'-0" PROPOSED FOUNDATION PLAN Scale: 1/4" = 1'-0"1 E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 1 A4.1 2 A3.3 1 A3.4 3 A4.1 3 A3.3 4 A4.1 2 A4.1 TRIANGLE HOUSEFOUNDATION PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.4325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. 55 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD UP KITCHEN 104 W /D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING FOYER 101 A R T WA L L WASTE ART WALL 1'-0" 9'-8 1/4" T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-05D-05D-01 D-01D-01 D-01 D-01D-01D-013/4 BATH 106D-04D-03Stor. 109 32° 5 8° 5 8° 5'-11"built-in90°8'-1 1/4"STAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-10" 7949'-3 3/8"T.O. GRAVEL (E) 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP 2 '- 7 1 / 2 " 4 '- 7 " 2 '- 6 1 / 4 "6'-5"5'-2 1/4"2'-0 1/4"2'-11"4'-2 1/2"2'-8 3/4"18'-4"6'-4" CLOSET 21'-7 3/4" D-05 DESK RECYCLE OFF STREET PARKING13'-2 1/2" T.O. Foyer 101'-0 3/4" T.O. GRAVEL (E) 100'-11 3/4" 7949'-5 1/8" 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-2 1/2" 5'-0" 5'-0" PROPOSED MAIN LEVEL PLAN Scale: 1/4" = 1'-0"1 E1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 29'-10 1/2"PRINCIPAL BUILDING DEPTH1 A4.1 2 A3.3 1 A3.4 3 A4.1 3 A3.3 4 A4.1 2 A4.1 HARDSCAPE TRIANGLE HOUSEMAIN LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.5325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. 56 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD Anteroom 203 ANTEROOM 203 Bedroom 201 BEDROOM 201 Office 202 OFFICE 202 Bath 204 BATH 204 Hall 205 HALL 205 T.O. F.F. (Exist.) 107'-11 7/8" BOOKCASE CL. 1'-7"8"2'-10 3/4"2'-9"1'-5"6'-8 3/4"Wndw Niche 206 STAIRS 107 T.O. F.F. (Exist.) 107'-11 7/8" 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-2 1/2" 5'-0" 5'-0" PROPOSED UPPER LEVEL PLAN Scale: 1/4" = 1'-0"1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 E2E2 E3E3 E4E4 E1E1 S1 S1 N1 N1 S9 S9 N2 N2 1 A4.1 2 A3.3 1 A3.4 3 A4.1 3 A3.3 4 A4.1 2 A4.1 open to below TRIANGLE HOUSEUPPER LEVEL PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.6325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. 57 GRAVEL PARKING GRAVEL PARKING EDGE OF PAVEMENT 5'-0"SIDE YARD10'-0"FRONT YARDPARK AVENUE 10'-0"REAR YARD UP KITCHEN 104 W /D LIVING 102 DINING 105 Carport 101 OFF STREET PARKING FOYER 101 WASTE T.O. BRICK 100'-0" (7948.45) T.ROAD (7947.69)D-05D-05D-01 D-01D-01 D-01 D-01D-01D-013/4 BATH 106D-04D-03Stor. 109 built-inSTAIRS 107 PANELS & METERSWaste/Stor. 108 T.O. BRICK 99'-5" UP UP DN T.O. BRICK 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-10" 7949'-3 3/8"T.O. GRAVEL (E) 100'-11 3/4" 7949'-5 1/8" T.O. CONC. 100'-0" 7948'-5 3/8" T.O. GRAVEL 100'-11 3/4" UP UP CLOSET 21'-7 3/4" D-05 RECYCLE OFF STREET PARKINGT.O. Foyer 101'-0 3/4" T.O. GRAVEL (E) 100'-11 3/4" 7949'-5 1/8" 48'-8 1/4" 2'-10"20'-5 3/4"25'-4 1/2"23'-10 1/2"5'-7 3/4"29'-6 1/4"2'-0"3'-7 3/4"23'-10 1/2"2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 5'-2 1/2" 5'-0" 5'-0" PROPOSED ROOF PLAN Scale: 1/4" = 1'-0"1REAR YARDF R O N T YA R D SID E Y A R D 10'-0" REAR YARD SETBACK EXISTING NON-CONFORMITY TO REMAIN UNCHANGED (NOT IN THIS SCOPE)10'-0"FRONT YARD SETBACK5'-0"FRONT YARD SETBACK10'-0"FRONT YARD SETBACKUPPER LEVEL, TWO-STORY ROOF #1 MAIN LEVEL, SINGLE-STORY ROOF #1 MAIN LEVEL SINGLE-STORY ROOF #2 5'-0" CARPORT SETBACK 3. One-Story Stepdown. The principal building shall include a one-story component on one (1) side of the building that remains one (1) story from the front façade to the rear wall. The width of the one-story portion shall be a minimum of twenty percent (20%) of the building's (or unit's) overall width. The one-story portion may be fully enclosed and used as living area. Accessible space (whether it is a deck, porch or enclosed area) shall not be allowed over the first story element; however, accessible space over the remaining first story elements on the front façade shall not be precluded. Also reference: 26.410.010.d (d) Remodels. Where work is proposed on any element of an existing building that is addressed by the Residential Design Standards and that is not in compliance with the Standards, the property owner shall make a reasonable effort to bring that element into compliance. The Community Development Director may grant exceptions for remodels that would require significant additional work above and beyond the scope of the remodel in order to ensure that all features are brought into compliance.SIDE YARDE1E1 E2E2 E3E3 E4E4 S1 S1 S2 S2 S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 N1 N1 S9 S9 N2 N2 1 A4.1 2 A3.3 1 A3.4 3 A4.1 3 A3.3 4 A4.1 2 A4.1 UPPER LEVEL, TWO-STORY ROOF #2 open to below TRIANGLE HOUSEROOF PLAN JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A2.7325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. 58 TRIANGLE HOUSEEXISTING EXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A3.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.05Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Elevation South-West Existing Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.06Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 East Existing EXISTING EAST ELEVATION SCALE: 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION SCALE: 1/4" = 1'-0"1 T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 100'-0" = 7948.45' 59 TRIANGLE HOUSEEXISTING EXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A3.2325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. Level 1.5 Natural Grade 0' - 0" Level 2 As-Built 5' - 10" Level 3 Upper Floor 14' - 10 1/2" Level 4 Roof Top 24' - 6 1/2" Level 1 -2' - 0" Level 1 Addition -1' - 6" Level 3 Ceiling 23' - 10 1/2" Top of Parapet 8' - 6"Don McDonald, Architect AIA Ltd.2121 North Main AvenueSan Antonio, Texas 78212(210) 735-9722Author Issue Date A0.04Triangle House325 Park Street, Aspen Colorado 81611 1/4" = 1'-0"1 Elevation North West Existing EXISTING NORTH ELEVATION SCALE: 1/4" = 1'-0"1 T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 60 SOUTH ELEVATION Scale: 1/4" = 1'-0"2 T.O. WNDW 114'-11 7/8" T.O. CARPORT 110'-5" T.O. GRAVEL @ CARPORT 100'-11 3/4" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. F.F. @ FOYER 101'-0 3/4" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" 100'-0" = 7948.45' T.O. PARAPET 111'-7"TRIANGLE HOUSEEXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A3.3325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. EAST ELEVATION 2 SCALE: 1/4" = 1'-0"3 8'-0"B.O. WNDW 110'-5 7/8" T.O. WNDW 114'-11 5/8" S1 S2 S3 S4 S5 S6 S7 S8 S9 Top of Parapet 111'-7" T.O. ROOF @ CARPORT 110'-5" T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F,F, @ ENTRY 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" T.O. F.F. @ FOYER 101'-0 3/4" T.O. GRAVEL @ CARPORT 100'-11 3/4" 100'-0" = 7948.45' 2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" 61 TRIANGLE HOUSEEXTERIOR ELEVATIONS JOB NO:PRINTED:Triangle_Annes-Working Permit.vwx20064Friday, November 19, 2021A3.4325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. existing grade FIXED WEST ELEVATION Scale: 1/4" = 1'-0"1 EXISTING STOVE VENT/EXHAUST TO REMAIN EXISTING MECHANICAL ROOM WALL VENT. ALL EXISTING MECHANICAL EQUIPMENT IS CURRENTLY LOCATED BENEATH EXISTING STAIRS AND WILL REMAIN. T.O. ROOF 117'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ MAIN LEVEL LIVING 100'-0" T.O. F.F. @ MAIN LEVEL 99'-5" 100'-0" = 7948.45' 62 SECTION 1 SCALE: 1/4" = 1'-0"1 7'-2 1/8"B.O. NEW BEAMNEW BEAM RE:STRUCT. W8X31 100'-0" = 7948.45' 2'-0"3'-7 3/4"23'-10 1/2"6'-11 1/4"T.O. F.F. MAIN LEVEL 100'-0" T.O. PARAPET 111'-5" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F. @ ENTRY 101'-0 3/4" E1 E2 E4E3 T.O. ROOF 117'-2 1/4" B.O. FTG. REF. STRC. B.O. HDR. 109'-2 1/4"8'-1 1/2"TRIANGLE HOUSEBUILDING SECTIONS JOB NO:PRINTED:Triangle_Annes-Variance Permit.vwx20064Friday, November 19, 2021A4.1325 Park AveAspen CO, 81611SHEET NO.COPYRIGHT 2021 F&M Architects, LLC PO Box 676215 Kearns Rd. Snowmass Village,CO 81615 info@fandmarchitects.com 970.987.2707DATEISSUE SHEET NAME. 6/10/21STREAM MARGIN 6/16/21STRCT. COORD. N1N2 SECTION 2 SCALE: 1/4" = 1'-0"2 EXISTING BUILDING T.O. F.F. @ ADDTION 100'-0" T.O. LOWER ROOF 110'-5" 100'-0" = 7948.45' 5'-2 1/2" T.O. F.F. @ UPPER LEVEL 107'-11 7/8" B.O. FTG. RE. STRCT. B.O. HDR. 108'-1 1/2"8'-1 1/2"E1E2E3 SECTION 4 SCALE: 1/4" = 1'-0"4 2'-0"3'-7 3/4" T.O. F.F @ MAIN LEVEL (EXIST) 99'-5" T.O. F.F @ MAIN LEVEL ADDITION 101'-0 3/4" T.O. F.F @ UPPER LEVEL 107'-11 7/8" T.O. F.F @ UPPER LEVEL 117'-2 1/4" B.O. FTG. REF. STRCT. B.O. HDR. 106'-6 1/4" B.O. HDR. 115'-0 3/8"5'-1 1/4"2'-4"SECTION 3 SCALE: 1/4" = 1'-0"3 T.O. F.F. @ UPPER LEVEL 107'-11 7/8" T.O. F.F @ MAIN LEVEL ADDITION 100'-0" T.O. F.F. @ FOYER 101'-0 3/4" T.O. GRAVEL @ CARPORT 100'-11 3/4" T.O. F.F. @ MAIN LEVEL (EXIST) 99'-5" CARPORT T.O. ROOF @ CARPORT 110'-5"8'-5 1/4"T.O. ROOF @ CARPORT 117'-2 3/8" T.O. PARAPET 111'-5" S1 S2 S3 S4 S5 S6 S7 S8 S9 100'-0" = 7948.45' 2'-10"5'-8 3/4"2'-7"7'-6 1/2"4'-7 1/2"10'-2 1/4"6'-10"8'-4 3/8" B.O. FTG. REF. STRCT. FOYER LIVING(BYND)6'-11 7/8"63 TRIANGLEHOUSEFriday, November 19, 2021F&M ARCHITECTS3. One-Story Stepdown. The principal building shall include a one-story component on one (1) side of the building that remains one (1) story from the front façade to the rear wall. The width of the one-story portion shall be a minimum of twenty percent (20%) of the building's (or unit's) overall width. The one-story portion may be fully enclosed and used as living area. Accessible space (whether it is a deck, porch or enclosed area) shall not be allowed over the first story element; however, accessible space over the remaining first story elements on the front façade shall not be precluded. ARIAL PERSPECTIVE ENTRY PERSPECTIVE SOUTH RENDERING EXHIBIT B.464 65 66 67 68 69 70 71 72 73 74 75 Board of Adjustment Resolution No. XX, Series 2021 Page 1 of 3 RESOLUTION NO. 02 (SERIES OF 2021) A RESOLUTION OF THE CITY OF ASPEN BOARD OF ADJUSTMENT APPROVING A PERMITTED USEVARIANCE FOR THE PROPERTY LEGALLY DESCRIBED AS A PORTION OF THE MASCOTTE LODE M.S. #5867 IN THE NW1/4 OF THE NE1/4, SECTION 18, TOWNSHIP 10 SOUTH, RANGE 84 WEST OF THE 6TH P.M., CITY OF ASPEN, COLORADO, MORE FULLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTH END LINE OF SAID MASCOTTE CLAIM FROM WHENCE CORNER NO.1 OF THE MASCOTTE BEARSN89° 46'W127.9FEET; THENCE S 89°46' E 5.00 FEET;THENCEN 01°36' E 34.50FEET; THENCE N 03°05' W 61.71 FEET; THENCE S 38°00' W 82.86 FEET; THENCE S 57°31' E 57.34 FEET TO THE POINT OF BEGINNING, PITKIN COUNTY, COLORADO, COMMONLY KNOWN AS 325 PARK AVENUE. Parcel ID No: 2737-181-00-211 WHEREAS,the Community Development Department received an application from Wiezbowski Sharon A. & Stephen L. Revocable Trust (Applicant), represented by Flynn Stewart-Severy of F&M Architects LLC (Representative), for a DimensionalVariance, Administrative Residential Design Standard (RDS) Approval, and an Administrative Stream Margin Review Exemption: pursuant to Land Use Code Chapters 26.314, 26.410, and 26.435 WHEREAS, all code citation references are to the City of Aspen Land Use Code in effect on the day the application was deemed complete – July 14 th, 2021, as applicable to this Project; and, WHEREAS,the Community Development Department referred the Application to the City of Aspen Parks and Engineering Departments, and received recommendations of approval with conditions; and, WHEREAS, the Board of Adjustment open and continued a request for a Setback Variance, at a duly noticed public hearing on November 11th, 2021. The Board of Adjustment reviewed and considered the development proposal under the applicable provisions of the Municipal Code identified herein, as a continued public hearing on December 2nd, 2021; and, WHEREAS,all required public noticing was provided as evidenced by an affidavit of public notice submitted to the record; and, WHEREAS,the Board of Adjustment finds the request to meet the Review Criteria (Section 26.314.040) for a Dimensional Variance, and have combined administrative approval for Stream Margin (Section 26.435.040), and Residential Design Standard (Section 26.410.030) reviews; and, WHEREAS,during a duly noticed public hearing on December 2nd, 2021, the Board of Adjustment approved Resolution 02,Series of 2021, by a___to ___(_-_)vote, approving aSetbackVariances, Stream Margin, and Residential Design Standards reviews for the development as shown in Exhibit A, and as identified herein. NOW, THEREFORE BE IT RESOLVED BY THE BOARD OF ADJUSTMENT OF THE CITY OF ASPEN, COLORADO THAT: Section 1: BOA Dimensional Variance Approval Pursuant to the procedures and standards set forth in Title 26 of the Aspen Municipal Code, the Board of Adjustment hereby grantsa 5’Front Yard Setback Variancefor the carport roof overhang, up to a 3’ Setback Variance for the Front Entry, and a 3’ Variance for the supporting column of the carport (Section 26.314.040) to allow for a remodel and addition to the subject site, as depicted in Exhibit A. The resulting setbacks for these features as measured from the front lot line: 76 Board of Adjustment Resolution No. XX, Series 2021 Page 2 of 3 Carport: 5’ Front entry: 7’ Carport column: 7’ Section 2: Residential Design Standard Approval The Application qualifies for Administrative approval for compliance with the residential design Standards pursuant to Section 26.410.030. The approved administrative checklist is attached to this Resolution as Exhibit B. The RDS approval is combined to be approved as part of the Resolution with the other land use approvals for efficiency and clarity. Section 3: Stream Margin Exemption Approval A portion of the lot is within the Stream Margin Review Area as established by Section 26.435.040.C. All development with the Stream Margin Review area is subject to the Stream Margin Review. The proposed remodel and addition as depicted in Exhibit A, qualify for an Administrative Stream Margin Exemption, but is combined to be approved as part of this Resolution for efficiency and clarity. Section 3: Engineering Department All activity on 325 Park Ave. must comply with Title 21 of the City of Aspen Municipal Code, and all adopted regulations of the City of Aspen Engineering Department. Section 4: Parks Department All activity on 325 Park Ave. must comply with all adopted regulations of the City of Aspen Parks Department. The following conditions shall be met prior to issuance of a building permit: A. Tree Protection Plan: A tree protection plan and any required tree removal permits must be approved prior to building permit issuance. B. No activity or storage of material is allowed within the Tree Protection Fencing. Section 5: All material representations and commitments made by the Applicant pursuant to the development proposal approvals as herein awarded, whether in public hearing or documentation presented before the Community Development Department and the Board of Adjustment Commission, are hereby incorporated in such plan development approvals and the same shall be complied with as if fully set forth herein, unless amended by other specific conditions or an authorized authority. Section 6: This Resolution shall not affect any existing litigation and shall not operate as an abatement of any action or proceeding now pending under or by virtue of the ordinances repealed or amended as herein provided, and the same shall be conducted and concluded under such prior ordinances. Section 5: Pursuant to Land Use Code Section 26.314.070, the subject variance shall expire 12 months from the date of the approval unless development has commenced as illustrated by the submission of a building permit or an extension is granted. The subject variance is not a Site-Specific Development Plan (SSDP), is not vested, and will not receive a Development Order. Section 6: If any section, subsection, sentence, clause, phrase, or portion of this Resolution is for any reason held invalid or unconstitutional in a court of competent jurisdiction, such portion shall be deemed a separate, distinct and independent provision and shall not affect the validity of the remaining portions thereof. 77 Board of Adjustment Resolution No. XX, Series 2021 Page 3 of 3 FINALLY,approved this 2nd day of December, 2021. Approved as to form: Approved as to content: ________________________________________________________ Katharine Johnson,Andrew Sandler, Chair Assistant City Attorney Attest: _______________________________ Mike Sears, Deputy Clerk Exhibit A: Approved Plans Exhibit B: RDS Checklist 78