HomeMy WebLinkAboutFile Documents.700 S Monarch St.0101-2020-BRES (5)Designed by/for:Viking Construction EST# 10141
700 S Monarch St, #203
Date: 9/2/2020
ARCHITECTURAL GUIDE SPECIFICATION
SECTION 088000 GLAZING
Note to Specifiers:
The specifications below are suggested as desirable inclusions in glass and glazing specifications (section
088000), but are not intended to be complete. An appropriate and qualified Architect or Engineer must verify
suitability of a particular product for use in a particular application as well as review final specifications. Oldcastle
BuildingEnvelope® assumes no responsibility or liability for the information included or not included in these
specifications.
APPROVED GLASS FABRICATOR Oldcastle BuildingEnvelope®
GLAZING PRODUCTS
Glass Standards
1. USA - Annealed float glass shall comply with ASTM C1036, Type I, Class 1 (clear), Class 2
(tinted), Quality-Q3. Canada - Annealed float glass shall comply with CAN/CGSB-12.3-M,
Quality-Glazing.
2. USA - Heat-strengthened float glass shall comply with ASTM C1048, TypeI, Class 1 (clear),
Class 2 (tinted), Quality Q3, Kind HS.
Canada - Heat-strengthened float glass shall comply with CAN/CGSB-12.9-M, Type 2-Heat-
Strengthened Glass, Class A-Float Glass.
3. USA - Tempered float glass shall comply with ASTM C1048, Type I, Class 1 (clear), Class 2
(tinted), Quality Q3, Kind FT. Canada - Tempered float glass shall comply with CAN/CGSB-
12.1M, Type 2-Tempered Glass, Class B-Float Glass.
4. USA - Laminated glass to comply with ASTM C1172. Canada - Laminated glass to comply with
CAN/CGSB-12.1-M, Type 1-Laminated glass, Class B-Float Glass.
5. USA & Canada - Glass shall be annealed, heat-strengthened or tempered as required by
codes, or as required to meet thermal stress and wind loads.
SystemSelect™Glass Product Builder
1 of 2
Performance Datasheet
www.obe.com/systemselect
Contact Oldcastle BuildingEnvelope® at 866-OLDCASTLE (653-2278) for samples or additional information. SystemSelect® calculates center of glass data using the Lawrence
Berkeley National Laboratory (LBNL) Berkeley Lab WINDOW Calc Engine (CalcEngine) with thermal performance per NFRC 100, 200 & 500. Glass data is from following
sources: 1. LBNL International Glazing Database (IGDB) v70.0; 2. Vendor supplied data; 3. LBNL Optics 6; 4. Based on vendor testing, clear acid-etched glass performance
data is estimated using regular clear glass of equivalent thickness. Framing system values and glass spacer values determined per LBNL THERM 7.4. Thermal values are in
both Imperial (IP) and Metric (SI) units.
09/09/2020
Sealed Insulating Glass (IG)
Vision Glass (Vertical)
1. IG units consist of glass lites separated by a dehydrated airspace that is hermetically dual
sealed with a primary seal of polyisobutylene (PIB) or Thermoplastic Spacer (TPS) a and a
secondary seal of silicone or an organic sealant depending on the application.
2. USA - Insulating glass units are certified through the Insulating Glass Certification Council
(IGCC) to ASTM E2190. Canada - Insulating Glass units are certified through the Insulating
Glass Manufacturers Alliance (IGMA) to either the IGMAC certification program to CAN/CGSB-
12.8, or through the IGMA program to ASTM E2190.
IG VISION UNIT PERFORMANCE CHARACTERISTICS
1. Exterior Lite: 3mm (1/8") Vitro Solarban® 70 Low-E #2
2. Cavity: 1/2" (Air Fill)
3. Interior Lite: 3mm (1/8") Pilkington Energy Advantage™ on Clear Low-E #4
4. Performance Characteristics
Thermal Optical
Winter U-factor (Btu/h·ft2·F):0.23 Visible Light Transmittance:59%
Winter U-factor (W/m2·K):1.31 Visible Light Reflectance (outside):14%
Solar Heat Gain Coefficient:0.26 Visible Light Reflectance (inside):16%
Shading Coefficient:0.29 Total Solar Transmittance:22%
Light to Solar Gain:2.30 Total Solar Reflectance (outside):43%
Ultraviolet Transmittance:4%
SystemSelect™Glass Product Builder
2 of 2
Performance Datasheet
www.obe.com/systemselect
Contact Oldcastle BuildingEnvelope® at 866-OLDCASTLE (653-2278) for samples or additional information. SystemSelect® calculates center of glass data using the Lawrence
Berkeley National Laboratory (LBNL) Berkeley Lab WINDOW Calc Engine (CalcEngine) with thermal performance per NFRC 100, 200 & 500. Glass data is from following
sources: 1. LBNL International Glazing Database (IGDB) v70.0; 2. Vendor supplied data; 3. LBNL Optics 6; 4. Based on vendor testing, clear acid-etched glass performance
data is estimated using regular clear glass of equivalent thickness. Framing system values and glass spacer values determined per LBNL THERM 7.4. Thermal values are in
both Imperial (IP) and Metric (SI) units.
09/09/2020